Agilent N4010A WLAN Test Suite

MeasurementFrequencyError11a Class

IEEE 802.11a Frequency Error measurement

For a list of all members of this type, see MeasurementFrequencyError11a Members.

System.Object
   Agilent.N4010.WLanTest.Measurements.MeasurementBaseFrontEnd
      Agilent.N4010.WLanTest.Measurements.MeasurementBaseSingleResultFrontEnd
         Agilent.N4010.WLanTest.Measurements.MeasurementFrequencyError11a

[Visual Basic]
Public Class MeasurementFrequencyError11a
    Inherits MeasurementBaseSingleResultFrontEnd
[C#]
public class MeasurementFrequencyError11a : MeasurementBaseSingleResultFrontEnd

Thread Safety

Public static (Shared in Visual Basic) members of this type are safe for multithreaded operations. Instance members are not guaranteed to be thread-safe.

Remarks

PICS Item: OF4.4.

This test requires a complete 802.11a signal.

Center frequency tolerance <= 20ppm

Requirements

Namespace: Agilent.N4010.WLanTest.Measurements

Assembly: Agilent.N4010.WLanTest (in Agilent.N4010.WLanTest.dll)

See Also