DRC Value Fixed Mode Attribute
Last updated: June 16, 2006
The
DRC Value Fixed Mode Attribute
controls whether the DRCValueFixedMode Attribute is included in the
FTAP Parameter Assignment Message
or
FETAP Parameter Assignment Message
sent to the AT. The
FTAP Parameter Assignment Message
is sent when the test set is configured to TAP (see
Test Application Protocol
). The
FETAP Parameter Assignment Message
is sent when the test set is configured to ETAP (see
Enhanced Test Application Protocol
).
DRC Value Fixed Mode Attribute
can be set to:
-
On (DRC Value Fixed Mode enabled)
In this mode, the DRCValueFixedMode attribute is sent in the
FTAP Parameter Assignment Message
or
FETAP Parameter Assignment Message
. The test set dictates the DRC value of the Forward Traffic Channel by sending the DRCValue in the DRCValueFixedMode attribute. The AT is required to use the indicated DRC value. This means that the AT must set its transmitted DRC to the value specified by the DRCValueFixedMode attribute.
The DRCValue in the DRCValueFixedMode attribute is set according to the
FTAP Rate
if sent in the
FTAP Parameter Assignment Message
or set according to the
F-Traffic Format
if sent in the
FETAP Parameter Assignment Message
.
-
Off (DRC Value Fixed Mode not enabled)
In this mode, the DRCValueFixedMode attribute is not sent in the
FTAP Parameter Assignment Message
or
FETAP Parameter Assignment Message
. This means that the AT requests the DRC value based on the current link conditions as in real system operation.
Unlike the subtype 0 physical layer, the subtype 2 physical layer supports multiple transmission formats in response to a DRC value requested by the AT. The
F-Traffic Config
determines which transmission format is used for each requested DRC value. To determine which physical layer subtype is configured, see
Release A Physical Layer Subtype
.
The
DRC Value Fixed Mode Attribute
is displayed on the
Call Setup
screen in the
Application Configuration
window when the
Session Application Type
is set to
Test Application
in the Active Cell operating mode.
Operating Considerations
-
DRC Value Fixed Mode Attribute
can be changed at any time. However, in some cases, changing this setting may result in an error message posted (see
Short Packet Enabled Threshold
for details).
-
When the
DRC Value Fixed Mode Attribute
is on, the DRC value sent by the AT will match the DRC value that the test set directs the AT to send in all properly operating ATs. However, if the AT does not send the DRC value indicated by the test set, the test set will follow the DRC value sent by the AT. When this happens, there is no error or indication.
|