AFGenerator

Last updated: July 25, 2008

GPIB Command Conventions

AFGenerator:COUPling

Function

Sets the output of the audio generator to be ac or dc coupled to the front-panel AUDIO OUT port.

Requirements

Test Application Revision: A.01.20 and above
Lab Application Revision: A.01 and above
Setting

Range: AC or DC

Query

Range: AC|DC

*RST setting DC

Programming Example

 
OUTPUT 714;"AFGENERATOR:COUPling AC" !Sets the audio generator coupling to AC.

AFGenerator:FREQuency

Function

Sets/queries the frequency of the audio generator. The units (HZ|KHZ|MHZ|GHZ) are optional. If no units are specified, then units default to HZ.

Requirements

Test Application Revision: A.01.20 and above
Lab Application Revision: A.01 and above
Setting

Range: 1 Hz to 20 kHz

Resolution: 0.1 HZ

Query

Range: 1 Hz to 20 kHz

Resolution: 0.1 Hz

*RST setting 1 kHz

Programming Example

 
OUTPUT 714;"AFGENERATOR:FREQUENCY 1000" !Sets the audio generator frequency to 1000 Hz.

AFGenerator:PULSe[:STATe]

Function

Sets/queries the audio generator pulse state.

The pulse state must be on when the test set's audio generator is used for audio stimulation during a decoded audio measurement.

When the state is on, the audio signal from the test set is pulsed at a 10 Hz rate with a 50% duty cycle.

Requirements

Test Application Revision: A.01.20 and above
Lab Application Revision: A.01 and above
Setting Range: 0 | OFF | 1 |ON

Query

Range: 0|1

*RST setting 0 (off)

Programming Example

 
OUTPUT 714;"AFGENERATOR:PULSE ON" !Sets the audio generator pulse to ON.

AFGenerator:VOLTage[:SAMPlitude]

Function

Sets /queries the amplitude of the audio generator in volts and turns the state to on. The units (V|mV) are optional. If no units are specified, then units default to V.

Requirements

Test Application Revision: A.01.20 and above
Lab Application Revision: A.01 and above
Setting

Range: 0 to 9 V pk.

Resolution:

  • 0.5 mV pk. <= 1 V pk. output
  • 5 mV pk. > 1 V pk. output

Query

Range: 0 to 9 V pk.

Resolution:

  • 0.5 mV pk. <= 1 V pk. output
  • 5 mV pk. > 1 V pk. output

*RST setting 0 V

Programming Example

 
OUTPUT 714;"AFGENERATOR:VOLTAGE 2.1" !Sets the state to on and the output
                                     !voltage to 2.1 volts.

AFGenerator:VOLTage:AMPlitude

Function

Sets/queries the amplitude for the audio generator when the audio generator state is on. The units (V|mV) are optional. If no units are specified, then units default to V.

Requirements

Test Application Revision: A.01.20 and above
Lab Application Revision: A.01 and above
Setting

Range: 0 to 9 V pk.

Resolution:

  • 0.5 mV pk. <= 1 V pk. output
  • 5 mV pk. > 1 V pk. output

Query

Range: 0 to 9 V pk.

Resolution:

  • 0.5 mV pk. <= 1 V pk. output
  • 5 mV pk. > 1 V pk. output

*RST setting 0 V

Programming Example

 
OUTPUT 714;"AFGENERATOR:VOLTAGE:AMPLITUDE 1.414" !Sets the audio generator output
                                                 !voltage to 1.414 volts peak.

AFGenerator:VOLTage:STATe

Function

Sets/queries the audio generator state

Requirements

Test Application Revision: A.01.20 and above
Lab Application Revision: A.01 and above
Setting 0 | OFF | 1 |ON

Query

0|1

*RST setting 0 (off)

Programming Example

 
OUTPUT 714;"AFGENERATOR:VOLTAGE:STATE ON" !Set the audio generator state to ON.