SYSTem:FATal

SYSTem:FATal

Last updated: November 19, 2005

Diagram Conventions

SYSTem:FATal:ERRor:RESTart

Function

This command sets/queries the state of the Restart on Fatal Error parameter. See Restart on Fatal Error for more information.

Error messages that are created when a fatal error occurs are entered in the error/event queue that can be queried with the command SYSTem:ERRor? .

This is a nonvolatile setting, that is the instrument does not require a power supply to retain the setting its memory.

Requirements

Test Application Revision: A.05 and above
Lab Application Revision: A.01 and above

Setting

Range: ON|1|OFF|0

Query

Range: 1|0

*RST Setting

0 (off)

Programming Example

 
OUTPUT 714;"SYSTem:FATal:ERRor:RESTart ON"
!Commands the instrument to restart if a fatal error occurs.