Test Adherence to Standards

Test Adherence to Standards

Last updated: October 16, 2009

Standards Table

Unless otherwise indicated, the capabilities shown in the tables apply to both the E1966A and the E6706A applications.

Support of C.S0033 Tests

C.S0033-A Test

Supported by Test Set?

Comments

3. Receiver Tests

3.1 Frequency Coverage Requirements

Yes

Supports Band Classes 0, 1, 3, 4, 5, 6, 10 and 14.

See Cell Band .

3.2.1 Demodulation of Forward Traffic Channel in AWGN

Yes

See Testing 3.2.1 Demodulation of Forward Traffic Channel in AWGN .

3.2.2 Demodulation of Forward Traffic Channel in Multipath Fading Channel

Yes. ( Lab Application Only )

Requires external fader and AWGN generator. For example, the E5515C Fading Solution, see Digital Bus Information for reference information. ( Lab Application Only )

See also Testing 3.2.2 Demodulation of Forward Traffic Channel in Multipath Fading Channel (Lab Application Only) .

3.2.3 Decision of Power Control Bit for Channels Belonging to Different Power Control Sets During Soft Handoff

No

Requires soft handoff capability.

3.2.4 Decision of Power Control Bit for Channels Belonging to the Same Power Control Set

No

Requires soft handoff capability.

3.2.5 Demodulation of Reverse Power Control Channel During Soft Handoff

No

Requires soft handoff capability.

3.2.6 Demodulation of ARQ Channel

Yes

See Testing 3.2.6 Demodulation of ARQ Channel

3.2.7 Demodulation of Broadcast Channel

No

3.3.1 Receiver Sensitivity and Dynamic Range Yes

See Testing 3.3.1 Receiver Sensitivity and Dynamic Range .

3.3.2 Single Tone Desensitization

Partially

Requires external CW signal generator.

3.3.3 Intermodulation Spurious Response Attenuation

Partially

Requires two external CW signal generators.

3.3.4 Adjacent Channel Selectivity

Partially

Requires external HRPD (1xEV-DO) and CDMA sources.

3.3.5 Receiver Blocking Characteristics

Partially Requires external CW signal generator.

3.4.1 Conducted Spurious Emissions

No

Requires full spectrum analyzer

3.4.2 Radiated Spurious Emissions

No

Requires full spectrum analyzer

4. Transmitter Tests

4.1.1 Frequency Coverage

Yes

Supports Band Classes 0, 1, 3, 4, 5, 6, 10 and 14.

See Cell Band .

4.1.2 Frequency Accuracy

Yes See Testing 4.2.2 Waveform Quality and Frequency Accuracy .

4.2.1 Time Reference

Partially

Supports static time reference only.

See Testing 4.2.2 Waveform Quality and Frequency Accuracy .

4.2.2 Waveform Quality and Frequency Accuracy

Yes

See Testing 4.2.2 Waveform Quality and Frequency Accuracy .

4.3.1 Range of Open Loop Output Power

Partially

Supports 100% forward packet activity only (see Fixed Settings ).

See Testing 4.3.1 Range of Open Loop Output Power .

If you want to view the access probe sequence graphically, use Measuring Graphical Access Probe Power ( Lab Application Only ).

4.3.2 Time Response of Open Loop Power Control

Yes

See Testing 4.3.2 Time Response of Open Loop Power Control

4.3.3 Range of Closed Loop Power Control

Partially

Supports tests 1 and 3-11, Minimum Standard (a) only, by remote program only.

4.3.4 Maximum RF Output Power

Yes

See Testing 4.3.4 Maximum RF Output Power

4.3.5 Minimum Controlled Output Power

Yes

See Testing 4.3.5 Minimum Controlled Output Power

4.3.6 Standby Output Power

Partially

Supports idle standby output power fully.

Supports measurement of standby power between access probe bursts by remote program only.

4.3.7 RRI Channel Output Power

Yes

See Testing 4.3.7 RRI Channel Output Power
4.3.8.1 DRC Channel Output Power

Yes

See Testing 4.3.8 Code Domain Power
4.3.8.2 ACK Channel Output Power

Yes

See Testing 4.3.8 Code Domain Power
4.3.8.3 Data Channel Output Power Partially

Supports tests 1-5, 8-10.

See Testing 4.3.8 Code Domain Power

4.3.8.4 DSC Channel Output Power

Yes

This test is only used for subtype 2 physical layer testing. See Testing 4.3.8 Code Domain Power

4.4.1 Conducted Spurious Emissions

Yes

Supports adjacent and alternate channels only.

Testing 4.4.1 Conducted Spurious Emissions

4.4.2 Radiated Spurious Emissions

Partially

Requires external spectrum analyzer.

4.4.3 Occupied Bandwidth

Partially

Requires external spectrum analyzer.

5 MAC Layer Minimum Standards

5.2 Data Rate Control Performance

Yes

Supports tests 1-5.

See Testing 5.2 Data Rate Control Performance

Related Topics


E1966A 1xEV-DO Terminal Test Application Revision Information

C.S0029 Test Application Specification Description (TAP/ETAP/MCTAP)

Concurrent Measurements