3. Receiver Tests
|
|
3.1 Frequency Coverage Requirements
|
Yes
|
Supports Band Classes 0, 1, 3, 4, 5, 6, 10 and 14.
See
Cell Band
.
|
|
3.2.1 Demodulation of Forward Traffic Channel in AWGN
|
Yes
|
See
Testing 3.2.1 Demodulation of Forward Traffic Channel in AWGN
.
|
|
3.2.2 Demodulation of Forward Traffic Channel in Multipath Fading Channel
|
Yes. (
Lab Application Only
)
|
Requires external fader and AWGN generator. For example, the E5515C Fading Solution, see
Digital Bus Information
for reference information. (
Lab Application Only
)
See also
Testing 3.2.2 Demodulation of Forward Traffic Channel in Multipath Fading Channel (Lab Application Only)
.
|
|
3.2.3 Decision of Power Control Bit for Channels Belonging to Different Power Control Sets During Soft Handoff
|
No
|
Requires soft handoff capability. |
|
3.2.4 Decision of Power Control Bit for Channels Belonging to the Same Power Control Set
|
No
|
Requires soft handoff capability. |
|
3.2.5 Demodulation of Reverse Power Control Channel During Soft Handoff
|
No
|
Requires soft handoff capability. |
|
3.2.6 Demodulation of ARQ Channel
|
No
|
|
|
3.2.7 Demodulation of Broadcast Channel
|
No
|
|
|
3.3.1 Receiver Sensitivity and Dynamic Range
|
Yes |
See
Testing 3.3.1 Receiver Sensitivity and Dynamic Range
.
|
|
3.3.2 Single Tone Desensitization
|
Partially |
Requires external CW signal generator.
|
|
3.3.3 Intermodulation Spurious Response Attenuation
|
Partially
|
Requires two external CW signal generators.
|
|
3.3.4 Adjacent Channel Selectivity
|
Partially
|
Requires external HRPD (1xEV-DO) and CDMA sources.
|
|
3.3.5 Receiver Blocking Characteristics
|
Partially |
Requires external CW signal generator. |
|
3.4.1 Conducted Spurious Emissions
|
No
|
Requires full spectrum analyzer
|
|
3.4.2 Radiated Spurious Emissions
|
No
|
Requires full spectrum analyzer
|
|
|
|
4. Transmitter Tests |
|
4.1.1 Frequency Coverage
|
Yes
|
Supports Band Classes 0, 1, 3, 4, 5, 6, 10 and 14.
See
Cell Band
.
|
|
4.1.2 Frequency Accuracy
|
Yes |
See
Testing 4.2.2 Waveform Quality and Frequency Accuracy
. |
|
4.2.1 Time Reference
|
Partially |
Supports static time reference only.
See
Testing 4.2.2 Waveform Quality and Frequency Accuracy
.
|
|
4.2.2 Waveform Quality and Frequency Accuracy
|
Yes
|
See
Testing 4.2.2 Waveform Quality and Frequency Accuracy
. |
|
4.3.1 Range of Open Loop Output Power
|
Partially |
Supports 100% forward packet activity only (see
Fixed Settings
).
See
Testing 4.3.1 Range of Open Loop Output Power
.
If you want to view the access probe sequence graphically, use
Measuring Graphical Access Probe Power
(
Lab Application Only
).
|
|
4.3.2 Time Response of Open Loop Power Control
|
Yes
|
See
Testing 4.3.2 Time Response of Open Loop Power Control
|
|
4.3.3 Range of Closed Loop Power Control
|
Partially
|
Supports tests 1 and 3-11, Minimum Standard (a) only, by remote program only. |
|
4.3.4 Maximum RF Output Power
|
Yes
|
See
Testing 4.3.4 Maximum RF Output Power
|
|
4.3.5 Minimum Controlled Output Power
|
Yes
|
See
Testing 4.3.5 Minimum Controlled Output Power
|
|
4.3.6 Standby Output Power
|
Partially
|
Supports idle standby output power fully.
Supports measurement of standby power between access probe bursts by remote program only.
|
|
4.3.7 RRI Channel Output Power
|
Yes
|
See
Testing 4.3.7 RRI Channel Output Power
|
|
4.3.8.1 DRC Channel Output Power
|
Yes
|
See
Testing 4.3.8 Code Domain Power
|
|
4.3.8.2 ACK Channel Output Power
|
Yes
|
See
Testing 4.3.8 Code Domain Power
|
|
4.3.8.3 Data Channel Output Power
|
Partially |
Supports tests 1-5, 8-10.
See
Testing 4.3.8 Code Domain Power
|
|
4.3.8.4 DSC Channel Output Power
|
Yes |
This test is only used for subtype 2 physical layer testing. See
Testing 4.3.8 Code Domain Power
|
|
4.4.1 Conducted Spurious Emissions
|
Yes
|
Supports adjacent and alternate channels only.
Testing 4.4.1 Conducted Spurious Emissions
|
|
4.4.2 Radiated Spurious Emissions
|
Partially
|
Requires external spectrum analyzer.
|
|
4.4.3 Occupied Bandwidth
|
Partially
|
Requires external spectrum analyzer.
|