Input Signal Requirements
Last updated: May 24, 2006
All measurements meet or exceed specifications when the following requirements are met:
-
The frequency of the signal being measured must be in the range of 412 MHz to 483 MHz, 800 MHz to 960 MHz, or 1.7 GHz to 2.0 GHz, and within 100 kHz of the expected frequency.
-
The signal level into the test set's RF IN/OUT connector must be within 9 dB of the expected input power (see
Expected Power
), and must be:
Input Signal Power Level Requirements
|
Measurement |
Input Signal Power Level Requirement |
|
Access Probe Power |
between -45 dBm and +37 dBm (-45 is the minimum level required to trigger the access probe power measurement). |
|
Channel Power |
between -61 dBm and +37 dBm (with reliable but unspecified performance down to -69 dBm). |
|
Digital Average Power |
between -30 dBm and +37 dBm. |
|
Packet Error Rate |
between -25 dBm and +37 dBm. |
|
TX Dynamic Power |
between -61 dBm and +37 dBm (with reliable but unspecified performance down to -69 dBm). |
|
TX Spurious Emissions |
between 0 dBm and +30 dBm. |
|
TROLPC |
between -25 dBm and +37 dBm. |
|
Waveform Quality + Code Domain |
between -25 dBm and +37 dBm. |
|