10 ! 4.3.4 Maximum RF Output Power
20 ! This programming example assumes the access terminal
30 ! is connected to the test set and in a 153.6 kbps
40 ! RTAP data connection.
50 !
60 Testset=714
70 !
80 DISP "Measuring Maximum Power"
90 !
100 !***Set up test parameters***
110 !
120 Ior=-60
130 ! Set cell power for test
140 Ol_adjust=84
150 ! Set Open Loop Adjust for Band Class 4
160 !
170 OUTPUT Testset;"CALL:APAR:POWER:OLADJUST ";Ol_adjust
180 ! Set Open Loop Adjust
190 OUTPUT Testset;"CALL:APAR:PROBE:IADJUST 15"
200 ! Set Probe Initial Adjust
210 OUTPUT Testset;"CALL:APAR:PROBE:STEP:COUNT 15"
220 ! Set Probe Num Steps
230 !OUTPUT Testset;"CALL:APAR:PROBE:SEQUENCE 15"
240 ! Set Probe Sequence Max - this parameter setting is required
250 ! by C.S0033 but does not affect test results. It is a legacy
260 ! parameter setting from IS-98. Changing this parameter drops
270 ! the connection, as required by C.S0024. It is recommended not
280 ! to send this command.
290 OUTPUT Testset;"CALL:APAR:PROBE:POWER:STEP 7.5"
300 ! Set Probe Step
310 !
320 !***Set up measurement parameters***
330 !
340 OUTPUT Testset;"SETUP:DAPOWER:CONTINUOUS OFF"
350 ! Set measurement to single trigger
360 OUTPUT Testset;"SETUP:DAPOWER:TIMEOUT 1"
370 ! Set DIGITAL Power timeout to 1 sec
380 !
390 !***Set test conditions***
400 !
410 OUTPUT Testset;"CALL:POW ";Ior
420 ! Set Cell Power for Test
430 OUTPUT Testset;"CALL:CLPCONTROL:REVERSE:MODE UP"
440 ! Start transmission of All Up (0) power control bits
450 WAIT 1
460 ! Settling time to allow mobile power to slew up to maximum power
470 !
480 !***Obtain measurement results***
490 !
500 OUTPUT Testset;"INITIATE:DAPOWER"
510 ! Initiate digital average power measurement
520 !
530 OUTPUT Testset;"FETCh:DAPOWER?"
540 ! Fetch the digital average power measurement results
550 ENTER Testset;Integrity,Avg_power_dbm
560 !
570 Avg_power_dbw=Avg_power_dbm-30
580 ! Convert dBm to dBW
590 !
600 !***Print Max Power Test Results***
610 !
620 CLEAR SCREEN
630 PRINT "Max Power Test Results:"
640 PRINT
650 PRINT "Integrity Indicator = ",Integrity
660 PRINT "Maximum Power (dBm) = ",Avg_power_dbm
670 PRINT "Maximum Power (dBW) = ",Avg_power_dbw
680 PRINT
690 PRINT "Maximum Output Power Test Complete"
700 !
710 !***Post test clean up***
720 !
730 OUTPUT Testset;"CALL:CLPCONTROL:REVERSE:MODE ACTIVE"
740 ! Return to active power control bits
750 OUTPUT Testset;"CALL:POW -55"
760 ! Set cell power back to initial level
770 ! Do this before reconfiguring other parms so signaling
780 OUTPUT Testset;"CALL:APAR:PROBE:IADJUST 0"
790 ! Set Access parameters for test
800 OUTPUT Testset;"CALL:APAR:PROBE:STEP:COUNT 5"
810 ! Set Access parameters for test
820 !OUTPUT Testset;"CALL:APAR:PROBE:SEQUENCE 1"
830 ! Set Access parameters for test (not necessary if commented
840 ! out command before test)
850 OUTPUT Testset;"CALL:APAR:PROBE:POWER:STEP 1"
860 ! Set Access paramters for test
870 OUTPUT Testset;"INIT:DAP:OFF"
880 ! Turn digital ave power off
890 DISP ""
900 !
910 END