How Do I Perform Multi-Unit Synchronization?
Last updated: June 18, 2007
This section is only applicable to the lab application and to a test application with the required feature license.
Multiple Sync Clients can synchronize to the same Sync Server at the same time. The following procedure provides an example of how to make a synchronization between two test sets. It assumes that the test set running the E6702B cdma2000 lab application acts as a Sync Client and another one running the E6706A 1xEV-DO lab application acts as a Sync Server.
Prior to the following procedure, make sure you have finished the synchronization connection between the two test sets (see
Synchronization Connection Setup
).
General Procedure
Step 1: Configure the Sync Server
Step 2: Configure the Sync Client
Step 3: Perform the synchronization between two test sets
Step 1: Configure the Sync Server
-
Press the
SYSTEM CONFIG
key.
-
Press the
Instrument Setup
(F1) key and set up the LAN IP Address if it is empty.
-
Press the
CALL SETUP
key.
-
Verify that the
Operating Mode
(
F1
) is set to
Active Cell
and
System Type
(
F2
) is set to
IS-2000
for this example.
-
Verify the External Trigger is set to 2 s.
Go to
Call Control 2 of 5 (Lab Application) or
Call Control 2 of 3
(Test Application),
press the
Generator Info
(
F3
), and then press the
External Trigger
(
F4
). For details, see
How Do I Change Generator Information?
.
-
Press the
More
key until
Call Control 2 of 5
(Lab Application) or
Call Control 2 of 3
(Test Application) is displayed.
-
Press
Cell Info
(
F2
) key.
-
Press
CDMA System Time/Sync Info
(
F5
) key.
-
Press
CDMA System Time Parms
(
F1
) key.
-
Set CDMA system time parameters by using the knob and DATA ENTRY keys.
Step 2: Configure the Sync Client
-
Press the
CALL SETUP
key.
-
Verify that the
Operating Mode
(
F1
) is set to
Active Cell
or and
System Type
is set to
IS-2000
(
F2
) for this example.
-
Make sure that test set is idle state.
-
Press the
More
key until
Call Control 2 of 5
(Lab Application) or
Call Control 2 of 3
(Test Application) is displayed.
-
Press
Cell Info
(
F2
) key.
-
Press
CDMA System Time/Sync Info
(
F5
) key.
-
Press
Clear Sync Indications
(
F4
) to clear the last synchronization event information.
-
Press
Ext 8960 IP Add
r (
F2
) key and input the number with DATA ENTRY keys to set the external Sync Server's IP address.
Step 3: Perform the synchronization between two test sets
-
Press
Sync To External Server
(
F3
) on the test set that acts as Sync Client to initiates the synchronization.
-
A typical synchronization result on the Sync Client and the Sync Server is shown below.
-
After finishing the synchronization:
-
If desired, press
Return
key (
F6
) on the left side of display to close the
CDMA System Time and Synchronization Information
window.
|