Settable Fields in Overhead Messages
Last updated: November 14, 2006
This section is only applicable to the lab application.
The test set communicates with a mobile station under test through messages formatted according to IS-95 or IS-2000 standards.
The overhead messages listed below have message fields which are directly or indirectly settable by the user. Overhead message fields not listed below are either specified by the standard or have been fixed to a suitable default value by the test set.
The General Page Message is included with Overhead Messages if it does not contain Page Records. If the General Page Message contains Page Records it is included with the Mobile Station Directed messages.
IS-95 Sync Channel Messages (P_REV < = 4)
Sync Channel Message Settable Fields
|
Field
|
Default Value (decimal) |
Test Set Field Name
|
Test Set Field Location
|
|
P_REV |
4 (95-B) |
Protocol Rev |
Protocol Rev softkey (Call Parms 1 of 3: F10) |
|
MIN_P_REV |
4 (95-B) |
Protocol Rev |
Protocol Rev softkey (Call Parms 1 of 3: F10) |
|
SID |
331 |
System ID
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
NID |
1 |
Network ID
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
PILOT_PN |
12 |
Cell 1 (or 2) PN Offset
|
Call Setup Screen, Call Control 2 of 3: Generator Information, Code Channel Parameters
|
|
PRAT
|
9600 (Full) |
Paging Data Rate
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
CDMA_FREQ
|
Current Band Channel |
Channel |
Channel softkey (Call Parms 1 of 3: F9)
|
IS-95 Paging Channel Overhead Messages (P_REV < = 4)
System Parameters Message Settable Fields
|
Field
|
Default Value (decimal) |
Test Set Field Name
|
Test Set Field Location
|
|
PILOT_PN |
12 |
Cell 1 (or 2) PN Offset
|
Call Setup Screen, Call Control 2 of 3: Generator Information, Code Channel Parameters
|
|
SID |
331 |
System ID
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
NID |
1 |
Network ID
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
BASE_ID |
39 |
Base ID
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
MAX_SLOT_CYCLE_INDEX |
1 |
Max Slot Cycle Index |
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
REG_PRD |
29 |
Registration Period
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Registration Parameters
|
|
T_ADD
|
28 |
T_Add
|
Call Setup Screen, Call Control 2 of 3: Soft Handoff Info, Soft Handoff Parameters
|
|
T_DROP |
32 |
T_Drop
|
Call Setup Screen, Call Control 2 of 3: Soft Handoff Info, Soft Handoff Parameters
|
|
T_COMP |
5 |
T_Comp
|
Call Setup Screen, Call Control 2 of 3: Soft Handoff Info, Soft Handoff Parameters
|
|
T_TDROP |
3 |
T_TDrop
|
Call Setup Screen, Call Control 2 of 3: Soft Handoff Info, Soft Handoff Parameters
|
Extended System Parameters Message Settable Fields
|
Field
|
Default Value (decimal) |
Test Set Field Name
|
Test Set Field Location
|
|
PILOT_PN |
12 |
Cell 1 (or 2) PN Offset
|
Call Setup Screen, Call Control 2 of 3: Generator Information, Code Channel Parameters
|
|
MCC |
310 |
Cell MCC |
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
IMSI_11_12
|
0 |
Cell MNC
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
P_REV |
4 (95-B) |
Protocol Rev |
Protocol Rev softkey (Call Parms 1 of 3: F10)
|
|
MIN_P_REV |
4 (95-B) |
Protocol Rev
|
Protocol Rev softkey (Call Parms 1 of 3: F10)
|
Access Parameters Message Settable Fields
|
Field
|
Default Value (decimal) |
Test Set Field Name
|
Test Set Field Location
|
|
PILOT_PN |
12 |
Cell 1 (or 2) PN Offset
|
Call Setup Screen, Call Control 2 of 3: Generator Information, Code Channel Parameters
|
|
NOM_PWR |
0 |
Nominal Power |
Call Setup Screen, Call Control 2 of 3: Cell Information, Access Parameters
|
|
INIT_PWR |
0 |
Initial Power |
Call Setup Screen, Call Control 2 of 3: Cell Information, Access Parameters
|
|
PWR_STEP |
3 |
Power Step |
Call Setup Screen, Call Control 2 of 3: Cell Information, Access Parameters
|
|
NUM_STEP |
3 |
Number of Steps |
Call Setup Screen, Call Control 2 of 3: Cell Information, Access Parameters
|
|
PAM_SZ
|
10 |
Preamble Size |
Call Setup Screen, Call Control 2 of 3: Cell Information, Access Parameters
|
|
MAX_REQ_SEQ |
1 |
Maximum Request Sequence |
Call Setup Screen, Call Control 2 of 3: Cell Information, Access Parameters
|
|
MAX_RSP_SEQ |
1 |
Maximum Response Sequence |
Call Setup Screen, Call Control 2 of 3: Cell Information, Access Parameters
|
|
NOM_PWR_EXT |
0 |
Nominal Power Extended |
Call Setup Screen, Call Control 2 of 3: Cell Information, Access Parameters
|
CDMA Channel List Message Settable Fields
|
Field
|
Default Value (decimal) |
Test Set Field Name
|
Test Set Field Location
|
|
PILOT_PN |
12 |
Cell 1 (or 2) PN Offset
|
Call Setup Screen, Call Control 2 of 3: Generator Information, Code Channel Parameters
|
|
CDMA_FREQ
|
Current Band Channel |
Channel |
Channel softkey (Call Parms 1 of 3: F9)
|
Neighbor List Message Settable Fields
|
Field
|
Default Value (decimal) |
Test Set Field Name
|
Test Set Field Location
|
|
PILOT_PN |
12 |
Cell 1 (or 2) PN Offset
|
Call Setup Screen, Call Control 2 of 3: Generator Information, Code Channel Parameters
|
Extended Neighbor List Message
|
Field
|
Default Value (decimal) |
Test Set Field Name
|
Test Set Field Location
|
|
PILOT_PN |
12 |
Cell 1 (or 2) PN Offset
|
Call Setup Screen, Call Control 2 of 3: Generator Information, Code Channel Parameters
|
IS-2000 Sync Channel Messages (P_REV > = 6)
Sync Channel Message Settable Fields
|
Field
|
Default Value (decimal) |
Test Set Field Name
|
Test Set Field Location
|
|
P_REV |
6 (IS-2000-0) |
Protocol Rev |
Protocol Rev softkey (Call Parms 1 of 3: F10) |
|
MIN_P_REV |
6 (IS-2000-0) |
Protocol Rev |
Protocol Rev softkey (Call Parms 1 of 3: F10) |
|
SID |
331 |
System ID
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
NID |
1 |
Network ID
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
PILOT_PN |
12 |
Cell 1 (or 2) PN Offset
|
Call Setup Screen, Call Control 2 of 3: Generator Information, Code Channel Parameters
|
|
PRAT
|
0 (full-rate)
|
Paging Data Rate
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
CDMA_FREQ
|
Current Band Channel |
Channel |
Channel softkey (Call Parms 1 of 3: F9)
|
|
EXT_CDMA_FREQ
|
Current Band Channel |
Channel |
Channel softkey (Call Parms 1 of 3: F9)
|
|
If P_REV > = 7 (IS-2000-A), include the following fields:
|
|
SR1_BCCH_NON_TD_INCL
|
1 |
Control Channel Configuration |
Call Setup Screen, Call Control 2 of 3: Cell Info, Control Channel Parameters
|
|
SR1_BRAT_NON_TD
|
1 |
F-BCCH Data Rate |
Call Setup Screen, Call Control 2 of 3: Cell Info, Control Channel Parameters
|
|
SR1_CRAT_NON_TD
|
1 (fixed by the test set) |
F-BCCH Data Rate |
Call Setup Screen, Call Control 2 of 3: Cell Info, Control Channel Parameters
|
|
SR1_BCCH_CODE_CHAN_NON_TD
|
1 (fixed by the test set) |
F-BCCH Data Rate |
Call Setup Screen, Call Control 2 of 3: Cell Info, Control Channel Parameters
|
IS-2000 Paging Channel Overhead Messages (P_REV > = 6)
The test set transmits these overhead messages on the paging channel (F-PCH) or primary broadcast control channel (F-BCCH) depending upon the current control channels.
System Parameters Message Settable Fields
|
Field
|
Default Value (decimal) |
Test Set Field Name
|
Test Set Field Location
|
|
PILOT_PN |
12 |
Cell 1 (or 2) PN Offset
|
Call Setup Screen, Call Control 2 of 3: Generator Information, Code Channel Parameters
|
|
SID |
331 |
System ID
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
NID |
1 |
Network ID
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
BASE_ID |
39 |
Base ID
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
MAX_SLOT_CYCLE_INDEX |
0 |
Max Slot Cycle Index |
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
POWER_UP_REG |
1 (On) |
Power Up Registration State |
Call Setup Screen, Call Control 2 of 3: Cell Information, Registration Parameters
|
|
REG_PRD |
0 (Off), Timer 29 |
Registration Period
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Registration Parameters
|
|
T_ADD
|
28 |
T_Add
|
Call Setup Screen, Call Control 2 of 3: Soft Handoff Info, Soft Handoff Parameters
|
|
T_DROP |
32 |
T_Drop
|
Call Setup Screen, Call Control 2 of 3: Soft Handoff Info, Soft Handoff Parameters
|
|
T_COMP |
5 |
T_Comp
|
Call Setup Screen, Call Control 2 of 3: Soft Handoff Info, Soft Handoff Parameters
|
|
T_TDROP |
3 |
T_TDrop
|
Call Setup Screen, Call Control 2 of 3: Soft Handoff Info, Soft Handoff Parameters
|
Extended System Parameters Message Settable Fields
|
Field
|
Default Value (decimal) |
Test Set Field Name
|
Test Set Field Location
|
|
PILOT_PN |
12 |
Cell 1 (or 2) PN Offset
|
Call Setup Screen, Call Control 2 of 3: Generator Information, Code Channel Parameters
|
|
MCC |
310
(or fixed to '1111111111' if Escape Mode = On) |
Cell MCC |
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
IMSI_11_12
|
0
(or fixed to '1111111' if Escape Me = On) |
Cell MNC
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
P_REV |
6 (IS-2000-0) |
Protocol Rev |
Protocol Rev softkey (Call Parms 1 of 3: F10) |
|
MIN_P_REV |
6 (IS-2000-0) |
Protocol Rev |
Protocol Rev softkey (Call Parms 1 of 3: F10) |
|
SOFT_SLOPE
|
0
|
Soft_Slope
|
Call Setup Screen, Call Control 2 of 3: Soft Handoff Info, Soft Handoff Parameters
|
|
ADD_INTERCEPT
|
0
|
Add_Intercept
|
Call Setup Screen, Call Control 2 of 3: Soft Handoff Info, Soft Handoff Parameters
|
|
DROP_INTERCEPT
|
0 |
Drop_Intercept |
Call Setup Screen, Call Control 2 of 3: Soft Handoff Info, Soft Handoff Parameters
|
|
QPCH_SUPPORTED
|
0 |
F-QPCH State |
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
QPCH_RATE
(indicator rate)
|
1 (QPCH indicator rate = 9600 bps) |
F-QPCH Data Rate
(F-QPCH data rate has one-on-one mapping to the indicator rate, that is, Full = 4800 bps QPCH data rate = 9600 bps QPCH indicator rate; Half = 2400 bps QPCH data rate = 4800 bps QPCH indicator rate)
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
QPCH_POWER_LEVEL_PAGE
|
010 (-3 dB) |
F-QPCH Relative to Pilot Level |
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
RLGAIN_TRAFFIC_PILOT
|
0 |
RL Traffic to Pilot Gain
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
Access Parameters Message Settable Fields
|
Field
|
Default Value (decimal) |
Test Set Field Name
|
Test Set Field Location
|
|
PILOT_PN |
12 |
Cell 1 (or 2) PN Offset
|
Call Setup Screen, Call Control 2 of 3: Generator Information, Code Channel Parameters
|
|
NOM_PWR |
0 |
Nominal Power |
Call Setup Screen, Call Control 2 of 3: Cell Information, Access Parameters
|
|
INIT_PWR |
0 |
Initial Power |
Call Setup Screen, Call Control 2 of 3: Cell Information, Access Parameters
|
|
PWR_STEP |
3 |
Power Step |
Call Setup Screen, Call Control 2 of 3: Cell Information, Access Parameters
|
|
NUM_STEP |
3 |
Number of Steps |
Call Setup Screen, Call Control 2 of 3: Cell Information, Access Parameters
|
|
PAM_SZ
|
10 |
Preamble Size |
Call Setup Screen, Call Control 2 of 3: Cell Information, Access Parameters
|
|
MAX_REQ_SEQ |
1 |
Maximum Request Sequence |
Call Setup Screen, Call Control 2 of 3: Cell Information, Access Parameters
|
|
MAX_RSP_SEQ |
1 |
Maximum Response Sequence |
Call Setup Screen, Call Control 2 of 3: Cell Information, Access Parameters
|
|
NOM_PWR_EXT |
0 |
Nominal Power Extended |
Call Setup Screen, Call Control 2 of 3: Cell Information, Access Parameters
|
CDMA Channel List Message Settable Fields
|
Field
|
Default Value (decimal) |
Test Set Field Name
|
Test Set Field Location
|
|
PILOT_PN |
12 |
Cell 1 (or 2) PN Offset
|
Call Setup Screen, Call Control 2 of 3: Generator Information, Code Channel Parameters
|
|
CDMA_FREQ
|
Current Band Channel |
Channel |
Channel softkey (Call Parms 1 of 3: F9)
|
Neighbor List Message Settable Fields
|
Field
|
Default Value (decimal) |
Test Set Field Name
|
Test Set Field Location
|
|
PILOT_PN |
12 |
Cell 1 (or 2) PN Offset
|
Call Setup Screen, Call Control 2 of 3: Generator Information, Code Channel Parameters.
|
Extended Neighbor List Message
|
Field
|
Default Value (decimal) |
Test Set Field Name
|
Test Set Field Location
|
|
PILOT_PN |
12 |
Cell 1 (or 2) PN Offset
|
Call Setup Screen, Call Control 2 of 3: Generator Information, Code Channel Parameters
|
IS-2000 Primary Broadcast Control Channel Overhead Messages (P_REV > = 7)
The test set supports the following overhead messages carried on the primary broadcast control channel (F-BCCH) when the protocol revision (P_REV) is no less than 7. The test set does not support the remaining F-BCCH overhead messages.
ANSI-41 System Parameters Message Settable Fields
|
Field
|
Default Value (decimal) |
Test Set Field Name
|
Test Set Field Location
|
|
PILOT_PN |
12 |
Cell 1 (or 2) PN Offset
|
Call Setup Screen, Call Control 2 of 3: Generator Information, Code Channel Parameters
|
|
SID |
331 |
System ID
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
NID |
1 |
Network ID
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
BASE_ID |
39 |
Base ID
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
POWER_UP_REG |
1 (On) |
Power Up Registration State |
Call Setup Screen, Call Control 2 of 3: Cell Information, Registration Parameters
|
|
REG_PRD |
1 (On), Timer 29 (=12.16 s) |
Timer Based Registration State,
Registration Period
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Registration Parameters
|
MC-RR Parameters Message Settable Messages
|
Field
|
Default Value (decimal) |
Test Set Field Name
|
Test Set Field Location
|
|
PILOT_PN |
12 |
Cell 1 (or 2) PN Offset
|
Call Setup Screen, Call Control 2 of 3: Generator Information, Code Channel Parameters
|
|
BASE_ID |
39 |
Base ID
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
P_REV |
7 (IS-2000-A) |
Protocol Rev |
Protocol Rev softkey (Call Parms 1 of 3: F10) |
|
MIN_P_REV |
6 (IS-2000-A) |
Protocol Rev |
Protocol Rev softkey (Call Parms 1 of 3: F10) |
|
T_ADD
|
28 |
T_Add
|
Call Setup Screen, Call Control 2 of 3: Soft Handoff Info, Soft Handoff Parameters
|
|
T_DROP |
32 |
T_Drop
|
Call Setup Screen, Call Control 2 of 3: Soft Handoff Info, Soft Handoff Parameters
|
|
T_COMP |
5 |
T_Comp
|
Call Setup Screen, Call Control 2 of 3: Soft Handoff Info, Soft Handoff Parameters
|
|
T_TDROP |
3 |
T_TDrop
|
Call Setup Screen, Call Control 2 of 3: Soft Handoff Info, Soft Handoff Parameters
|
|
SOFT_SLOPE
|
0
|
Soft_Slope
|
Call Setup Screen, Call Control 2 of 3: Soft Handoff Info, Soft Handoff Parameters
|
|
ADD_INTERCEPT
|
0
|
Add_Intercept
|
Call Setup Screen, Call Control 2 of 3: Soft Handoff Info, Soft Handoff Parameters
|
|
DROP_INTERCEPT
|
0 |
Drop_Intercept |
Call Setup Screen, Call Control 2 of 3: Soft Handoff Info, Soft Handoff Parameters
|
|
MCC |
310
(or fixed to '1111111111' if Escape Mode = On) |
Cell MCC |
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
IMSI_11_12
|
0
(or fixed to '1111111' if Escape Mode = On) |
Cell MNC
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
MAX_SLOT_CYCLE_INDEX |
0 |
Max Slot Cycle Index |
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
PWR_REP_THRESH |
0 |
Bad Frame Threshold (Frames) |
See
MS Reported FER Parameters
.
|
|
PWR_REP_FRAME |
7 (= 56 frames) |
Frame Interval of Report (Frames) |
|
PWR_THRESH_ENABLE |
0 |
Threshold Report Enable |
|
PWR_PERIOD_ENABLE |
0 |
Period Report Enable |
|
PWR_REP_DELAY |
14 (= 56 frames) |
Frame Delay of Report (Frames) |
|
FCCCH_RATE |
0 (=9.6 kbps, 20 ms frame) |
F-CCCH Data Rate |
Call Setup Screen, Call Control 2 of 3: Cell Info, Control Channel Parameters
|
|
FCCCH_CODE_RATE
|
1 (= 1/2 code rate) |
F-CCCH Data Rate |
Call Setup Screen, Call Control 2 of 3: Cell Info, Control Channel Parameters
|
|
QPCH_SUPPORTED
|
0 |
F-QPCH State |
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
QPCH_RATE
(indicator rate)
|
1 (QPCH indicator rate = 9600) |
F-QPCH Data Rate
(F-QPCH data rate has one-on-one mapping to the indicator rate, that is, Full = 4800 bps QPCH data rate = 9600 bps QPCH indicator rate; Half = 2400 bps QPCH data rate = 4800 bps QPCH indicator rate)
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
QPCH_POWER_LEVEL_PAGE
|
010 (-3 dB) |
F-QPCH Relative to Pilot Level |
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
|
RLGAIN_TRAFFIC_PILOT
|
0 |
RL Traffic to Pilot Gain
|
Call Setup Screen, Call Control 2 of 3: Cell Information, Cell Parameters
|
Enhanced Access Parameters Message Settable Fields
|
Field
|
Default Value (decimal) |
Test Set Field Name
|
Test Set Field Location
|
|
PILOT_PN |
12 |
Cell 1 (or 2) PN Offset
|
Call Setup Screen, Call Control 2 of 3: Generator Information, Code Channel Parameters
|
|
MAX_REQ_SEQ |
1 |
Maximum Request Sequence |
Call Setup Screen, Call Control 2 of 3: Cell Information, Enhanced Access Parms
|
|
MAX_RSP_SEQ |
1 |
Maximum Response Sequence |
Call Setup Screen, Call Control 2 of 3: Cell Information, Enhanced Access Paramus
|
|
RLGAIN_COMMON_PILOT |
0 |
RL Gain Common To Pilot |
Call Setup Screen, Call Control 2 of 3: Cell Information, Enhanced Access Paramus
|
|
IC_THRESH |
7 |
Interference Correction Threshold |
Call Setup Screen, Call Control 2 of 3: Cell Information, Enhanced Access Paramus
|
|
IC_MAX |
7 |
Interference Correction Maximum |
Call Setup Screen, Call Control 2 of 3: Cell Information, Enhanced Access Paramus
|
|
EACH_NOM_PWR |
0 |
EACH Nominal Power |
Call Setup Screen, Call Control 2 of 3: Cell Information, Enhanced Access Paramus
|
|
EACH_INIT_PWR |
0 |
EACH Initial Power |
Call Setup Screen, Call Control 2 of 3: Cell Information, Enhanced Access Paramus
|
|
EACH_PWR_STEP |
3 |
EACH Power Step |
Call Setup Screen, Call Control 2 of 3: Cell Information, Enhanced Access Paramus
|
|
EACH_NUM_STEP |
3 |
EACH Number of Steps |
Call Setup Screen, Call Control 2 of 3: Cell Information, Enhanced Access Paramus
|
|
EACH_BA_RATES_SUPPORTED
|
0xC0 (=9.6 kbps, 20 ms frame) |
EACH Data Rate Supported |
Call Setup Screen, Call Control 2 of 3: Cell Information, Enhanced Access Paramus
|
|
NOM_PWR_EXT |
0 |
Nominal Power Extended |
Call Setup Screen, Call Control 2 of 3: Cell Information, Enhanced Access Paramus
|
Extended CDMA Channel List Message
|
Field
|
Default Value (decimal) |
Test Set Field Name
|
Test Set Field Location
|
|
PILOT_PN |
12 |
Cell 1 (or 2) PN Offset
|
Call Setup Screen, Call Control 2 of 3: Generator Information, Code Channel Parameters
|
|
CDMA_FREQ
|
Current Band Channel |
Channel |
Channel softkey (Call Parms 1 of 3: F9)
|
Universal Neighbor List Message Settable Fields
|
Field
|
Default Value (decimal) |
Test Set Field Name
|
Test Set Field Location
|
|
PILOT_PN |
12 |
Cell 1 (or 2) PN Offset
|
Call Setup Screen, Call Control 2 of 3: Generator Information, Code Channel Parameters.
|
|
|