MEID / Enhanced PLCM
Last updated: July 24, 2008
Mobile Equipment Identifier (MEID) is a newly designed way to uniquely identify the mobile stations (MS) due to ESN exhaustion. In the Active Cell operating mode and IS-2000 system, the test set supports to test an MEID-equipped MS. The MEID related information either reported or retrieved during MS registration can be observed from the
Mobile Reported Information
screen. Also, you can establish a call between the test set and an MEID-equipped MS using the Public Long Code Mask (PLCM) determined by the specified
PLCM Type
.
MEID Support
The
MEID Support
setting is used to enable (
On
) or disable (
Off
) the test set to support of MEID and Enhanced PLCM tests for an MEID-equipped MS.
-
When the
MEID Support
is set to
On
,
-
and an MEID-equipped MS is detected during registration (
MEID Supported
indicates Yes), the test set sends the
Status Request Message
to retrieve the MEID value from the MS no matter what the
Status Request Query
setting is. Upon receiving the
Status Response Message
with MEID value, the test set displays the MEID result on the Mobile Reported Information screen (see
MEID
). You can also retrieve the MEID value from the MS by pressing the
F3
(
Query MEID
) or using
CALL:MS:REPorted:MEIDentifier:QUERy
command.
-
the test set can establish a call with an MEID-equipped MS using the Public Long Code Mask (PLCM) determined by the specified PLCM type. See
PLCM Type
for details.
-
the test set can not establish a call with an ESN-equipped MS.
-
When the
MEID Support
is set to
Off
,
-
the test set does not send the
Status Request Message
to an MEID-equipped MS to retrieve its MEID value. Also, you can not retrieve the MEID value from the MS by pressing the
F3
(
Query MEID
). The MEID-equipped MS only registers to the test set using pseudo-ESN which is derived from its MEID value. The pseudo-ESN reported from the MS is displayed on the Mobile Reported Information screen (see
ESN
).
-
the test set can establish a call with an MEID-equipped MS using the Public Long Code Mask (PLCM) derived from the pseudo-ESN value.
-
You can not change the
MEID Support
setting when a call is established.
GPIB Command:
CALL[:CELL]:MEIDentifier:SUPPort[:ENABle]
PLCM Type
The
PLCM Type
determines how an MEID-equipped MS generates its public long code mask (PLCM).
-
It is available only when the
MEID Support
is set to
On
.
-
It is sent to the MS via the PLCM_TYPE field in the
MEID Extended Channel Assignment Message
during a call establishment or in the
MEID Universal Handoff Direction Message
during an implicit handoff caused by the change of this setting.
Public Long Code Mask Type
|
PLCM Type |
Description |
PLCM_TYPE (binary) |
|
ESN Based
|
PLCM derived from ESN
|
0000
|
|
BS Assigned
|
PLCM specified by the base station
|
0001
|
|
MEID Based
|
PLCM derived from MEID
|
0100
|
-
The test set can establish a call with an MEID-equipped MS using the Public Long Code Mask (PLCM) generated based on the specified
PLCM Type
. If
ESN Based
or
BS Assigned
is selected, a call can be established regardless of MEID value. If
MEID Base
d is selected, a call can be established only when the MEID value is successfully reported or retrieved (
MEID
).
-
While a call other than
SO32+SCH
or
SO32+F-SCH
is established, changing the
PLCM Type
setting results in an implicit handoff (see also
Performing a Hard Handoff
). However, if the
PLCM Typ
e is changed from
ESN Based
or
BS Assigned
to
MEID Based
and the
MEID
value is empty due to a MEID query failure during registration, the call will be dropped. If the MEID results are empty due to cleared by pressing the
F5
(
Clear MS & Capability Info
) on
Call Control 2 of 3
or using
CALL:MS:REPorted:CLEar
command, the previously stored MEID value will be used and the handoff may succeed.
-
You can not change the
PLCM Type
while an
SO32+SCH
or
SO32+F-SCH
call is established.
-
If any of the measurements (Frame Error Rate, Waveform Quality + Code Domain, Handoff Waveform Quality and Code Channel Time/Phase Error) are running, changing the
PLCM Type
causes these measurements aborted and restarted.
GPIB Command:
CALL[:CELL]:PLCMask:TYPE
|