Setting External Trigger

Last updated: October 28, 2004

External trigger type selects the trigger that is routed to the rear panel TRIG OUT port (see Rear Panel Connectors ). The triggers are based off of the internal clocks/references of the test set and are the same signals that are used to trigger the measurements and call processing functionality.

External Trigger Type
Trigger Description
20 ms Frame clock
26.67 ms Sync channel frame (short code sequence rollover)
80 ms Paging channel slot
2 s Even second clock
FDEPendent

Function Dependent. The frequency and timing of trigger depends upon the set of measurements (such as Handoff Waveform Quality, Waveform Quality + Code Domain, Code Channel Time/Phase Error, Time Response of Open Loop Power Control and Tx Dynamic Power. See Triggering of Measurements .) and trigger generating operations that are currently being performed by the test set (for example, the trigger is produced coincident with the transmission of the first power control bit in a closed loop power control transient. See Starting the Reverse CLPC Transient .).

External trigger type can be changed at any time.

In addition to the user selected external trigger type, there is also a fixed external trigger that is always present at the BASEBAND I/O port, which triggers each time a power control bit is generated.