Last updated: December 20, 2006
This measurement is only available in
IS-2000 Test Operating Mode
.
RF Gen Freq Ctrl
(
F12
on
Call Parms 1 of 4
) to
Manual
.
Rcvr Power Control
(
F8
on
Call Parms 3 of 4
) to
Manual
(it is not necessary to set the
Manual Power
setting; it is not used by the measurement).
Meas Frequency
(
F10
on
call Parms 3 of 4
) and press the front panel
OFF
(
MANUAL
) key (the particular frequency displayed is not used by the measurement).
Fast Device Tune
measurement.
Fast Device Tune Setup
(
F1
) and set the measurement parameters as needed. Select
Close Menu
(
F6
).
Fast Device Tune MS TX/RX Parms
(
F2
), and configure the parameters as needed. Select
Close Menu
(
F6
) and
Return
(
F6
).
Graph Control
(
F3
). Set the axis control parameters as needed. Select
Return
(
F6
).
Marker
(
F2
) to turn on the marker on the graphical display.A typical result is shown below: