CALL[:CELL]:BCCHannel[:SLEVel]<[:SELected]|:DIGital2000>
|
Function
|
The setting form of this command performs two functions: (1) sets the forward broadcast control channel (F-BCCH) level, and (2) turns the F-BCCH on/off state to ON. The query form returns the F-BCCH level. See
Configuring Forward Channel Power Levels and Walsh Codes
.
The optional [:SELected] keyword in this command specifies that the F-BCCH level and state being set/queried applies to the current system type (
CALL:STATus:CELL:SYSTem[:TYPE]?
).
|
|
Setting
|
Range: 0 to -20 dB
Resolution: 0.0001 dB |
|
Query
|
Range: same as setting
|
|
*RST Setting
|
-15.2 dB |
|
Requirements
|
Test Application Revision: B.08 and above, with the required feature license
Lab Application Revision: B.02 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel -10"
!Sets F-BCCH state to on and its level to -10 dB.
|
CALL[:CELL]:BCCHannel:DRATe
|
Function
|
Sets/queries the coding rate, frame size and data rate of the forward broadcast control channel (F-BCCH). See
F-BCCH Data Rate
.
|
|
Setting
|
Range: H40Bps4800|H40Bps9600|H40Bps19200
H40Bps4800 - Half (1/2) code rate, 40 ms frame size, 4800 bps data rate
H40Bps9600 - Half (1/2) code rate, 40 ms frame size, 9600 bps data rate
H40Bps19200 - Half (1/2) code rate, 40 ms frame size, 19200 bps data rate
|
|
Query
|
Range: H40B4800|H40B9600|H40B19200
|
|
*RST Setting
|
H40Bps9600
|
|
Requirements
|
Test Application Revision: B.08 and above, with the required feature license
Lab Application Revision: B.02 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:DRATe H40Bps4800"
!Sets the F-BCCH data rate to 4.8 kbps
!with 1/2 code rate and 40 ms frame size.
|
CALL[:CELL]:BCCHannel:LEVel<[:SELected]|:DIGital2000>
|
Function
|
Sets/queries the F-BCCH level. See
Current Level and Desired Level
The optional [:SELected] keyword in this command specifies that the F-BCCH level and state being set/queried applies to the current system type (
CALL:STATus:CELL:SYSTem[:TYPE]?
).
|
|
Setting
|
Range: 0 to -20 dB
Resolution: 0.0001 dB |
|
Query
|
Range: same as setting
|
|
*RST Setting
|
-15.2 dB |
|
Requirements
|
Test Application Revision: B.08 and above, with the required feature license
Lab Application Revision: B.02 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:LEVel -10"
!Sets F-BCCH level to -10 dB
|
CALL[:CELL]:BCCHannel:STATe<[:SELected]|:DIGital2000>
|
Function
|
Sets/queries the forward F-BCCH channel on/off state. See
Current Level and Desired Level
.
The optional [:SELected] keyword in this command specifies that the F-BCCH level and state being set/queried applies to the current system type (
CALL:STATus:CELL:SYSTem[:TYPE]?
).
|
|
Setting
|
Range: 1|ON|0|OFF |
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test Application Revision: B.08 and above, with the required feature license
Lab Application Revision: B.02 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:STATe OFF"
!Sets the F-BCCH channel state to off.
|
|