CALL:WAVeform

CALL:WAVeform

Last updated: June 7, 2007

GPIB Command Conventions

CALL[:CELL[1]]:WAVeform:TYPE:CW

Function

Sets/queries the type of test signals to be output to the currently selected front-panel RF connector while in CW operating mode. See CW Operating Mode for details.

The test signals include:

  • CW generates an unmodulated continuous sine waveform signal.
  • AM generates an amplitude modulated signal with 56% depth and 20 kHz modulation rate.
  • DSB generates a dual side-band suppressed carrier signal with 20 kHz spacing between the two carriers.

When in CW operating mode, switching test signals requires a few seconds. A few seconds of delay is also encountered when changing operating modes if the current test signal is not CW.

Requirements

Test Application Revision: B.06.00 or above

Setting

Range: CW|AM|DSB

Query

Range: CW|AM|DSB

*RST Setting

CW

Programming Example

 
OUTPUT 714;"CALL:WAVeform:TYPE:CW AM" !Sets the test singal to AM.