FETCh:CTXSpurious
Last updated: June 7, 2007
GPIB Command Conventions
FETCh:CTXSpurious[:ALL]?
|
Function
|
Queries the TX spurious emissions measurement results.
This measurement returns results in the following order: integrity, TX spurious emissions pass/fail result, lower adjacent channel (-0.885 or -1.25 MHz) average TX spurious emissions, upper adjacent channel (+0.885 or +1.25 MHz) average TX spurious emissions, lower alternate channel (-1.98 MHz) average TX spurious emissions, upper alternate channel (+1.98 MHz) average TX spurious emissions.
|
|
Query
|
Integrity
TX spurious emissions pass/fail result
Lower adjacent channel spurious emissions
Upper adjacent channel spurious emissions
Lower alternate channel spurious emissions
Upper alternate channel spurious emissions
|
|
Programming Example
OUTPUT 714;"FETCH:CTXSPURIOUS?"
|
FETCh:CTXSpurious:ICOunt?
|
Function
|
Queries the intermediate count of measurements completed in a multi-measurement.
The multi-measurement state, by default, is off. To set up multi-measurements, see
SETup:CTXSpurious:COUNt[:SNUMber]
.
|
|
Query
|
Range: 0 to 999
|
|
Programming Example
OUTPUT 714;"FETCH:CTXSPURIOUS:ICOUNT?"
|
FETCh:CTXSpurious:MASK[:FAIL]?
|
Function
|
Queries the pass/fail indicator. Pass/fail results are based on fixed limit lines on display. Limit lines are determined by currently selected frequency band.
|
|
Query
|
Range: 0 (Pass)|1(Fail), 9.91 E+37
|
|
Programming Example
OUTPUT 714;"FETCH:CTXSPURIOUS:MASK:FAIL?"
|
|