Terminologies on the Test Set Adherence to Standard
Last updated: October 28, 2004
This table lists the parameters required to be set in most standard tests. It is to help you quickly find the menus/softkeys on the test set's front panel to configure the parameters as specified in the standard.
Example Settings
The following table is an example settings as specified in the standard. It also shows how to set on the test set to achieve the specified values. The Ioc, Traffic Ec/Ior, and Pilot Ec/Ior are all directly settable on the test set. For Ior/Ioc, which is the ratio of cell power to AWGN, you need to adjust Cell 1 Power (for Channel 1) and Cell 2 Power (for Channel 2) to achieve the correct levels relative to AWGN.
Test Parameters for Candidate Set Pilot Detection
|
Parameters in Standard |
Units |
Test 1 |
Equivalent Settings on the Test Set
|
|
Ior/Ioc |
dB |
-3.1 |
Set Cell Power to - 58.1 dBm/1.23 MHz (Ioc + Ior/Ioc)
|
|
Pilot Ec/Ior |
dB |
-7 |
Set Cell F-Pilot Level to -7 dB |
|
Traffic Ec/Ior |
dB |
-7 |
Set Cell F-FCH/Traffic Level to -7 dB
|
|
Ioc |
dBm/1.23 MHz |
-55 |
Set AWGN Power to -55 dBm/1.23 MHz.
|
|