Programming a Digital Average Power Measurement
Last updated: October 28, 2004
This section provides an example of how to make a digital average power measurement via GPIB.
The following program example assumes that the mobile station's antenna output is connected to the RF IN/OUT connector, and the mobile station has found service.
For information on configuring the test set for a call, see
Step 4: Make a connection
.
The basic procedure to measure digital average power is as follows:
-
Make a call.
-
Configure the digital average power setup parameters using the
SETup:DAPower
subsystem.
-
Start the digital average power measurement using the
INITiate
subsystem.
-
Use the
FETCh:DAPower
command to obtain the measurement results.
Programming Example
10 RE-SAVE "c:\roadhog\programs\avg_pwr.txt"
20 !This program measures average power
30 !Refer to "Maximum RF Output Power" in TIA/EIA-98-D for standards and specifications
40 CLEAR SCREEN
50 A=714
60 !
70 !***Specify call parameters***
80 Systype$="DIGITAL2000" !Cell System Type
90 Band$="USCellular" !Cell band
100 Channel=384 !RF channel
110 Sid=1 !System Identification
120 Nid=1 !Network Identification
130 Radio_config$="F3R3" !Radio Configuration
140 Service_opt$="SO2" !Service Option
150 !
160 !***Specify test parameters***
170 Loss_frequency$="836 MHZ,881 MHZ" !Reverse channel, forward channel frequencies for
amplitude offset (path loss)
180 Expected_loss$="-1,-1" !Path loss at reverse channel, forward channel frequencies
190 Ior=-104 !Cell Power
200 Pilot=-7 !Pilot channel power level
210 Traffic=-7.4 !Traffic channel power level
220 !
230 ON TIMEOUT 7,20 CALL Timeout ! Calls "Timeout" routine
240 OUTPUT A;"SETUP:DAPOWER:TIMEOUT:STIME 10 S" !***Sets average power measurement timeout to 10 seconds***
250 OUTPUT A;"SYST:COMM:GPIB:DEB:STAT ON"!***Turn debug state on***
260 !
270 !***Set up path loss***
280 OUTPUT A;"SYSTEM:CORRECTION:SFREQUENCY ";Loss_frequency$ !Enters frequencies in Amplitude Offset table
290 OUTPUT A;"SYSTEM:CORRECTION:SGAIN ";Expected_loss$ !Enters loss values in Amplitude
Offset table
300 !
310 !***Set up call parameters***
320 OUTPUT A;"CALL:OPER:MODE CALL" !***Sets Operating Mode to Active Cell***
330 OUTPUT A;"CALL:SYSTEM ";Systype$ !Sets System Type
340 OUTPUT A;"CALL:BAND ";Band$ !Sets Cell band for selected System Type
350 OUTPUT A;"CALL:CHAN ";Channel !Sets Channel for selected System Type and Cell Band
360 OUTPUT A;"CALL:POW -50" ! Sets and turns on Cell Power for selected System Type
370 OUTPUT A;"CALL:SID ";Sid ! Sets System Identification
380 OUTPUT A;"CALL:NID ";Nid ! Sets Network Identification
390 OUTPUT A;"CALL:RCON ";Radio_config$ !Sets Radio configuration
400 OUTPUT A;"CALL:SOPTION ";Service_opt$ !Sets service option for the selected System Type
and Radio Configuration
410 OUTPUT A;"CALL:PROT:DIG2000 PREV6" ! Sets Protocol Revision for the selected System Type
420 OUTPUT A;"CALL:PAG:DRAT FULL" !Sets F-Paging data rate to full rate
430 OUTPUT A;"CALL:PIL -7" !Sets pilot to default
440 OUTPUT A;"CALL:SYNC -16" !Sets sync to default
450 OUTPUT A;"CALL:PAG -12" !Sets paging to default
460 OUTPUT A;"CALL:FCH -15.6"!Sets traffic to default
470 !
480 PRINT "Turn on mobile station...press continue when it has found service and registered"
490 PAUSE
500 CLEAR SCREEN
510 OUTPUT A;"CALL:REGISTER:TIMER:STATE OFF" !Turns timer-based registration off
520 WAIT 2 !Waits 2 seconds for timer-based registrations in progress to clear out
530 !
540 !***Page the mobile station***
550 DISP "Paging mobile station..."
560 OUTPUT A;"CALL:ORIG" !Pages the mobile station
570 OUTPUT A;"CALL:CONNECTED:STATE?" !Queries for connected/idle state...hangs until state
change detector is disarmed
580 ENTER A;Call_connected
590 IF NOT Call_connected THEN
600 DISP "Call attempt failed"
610 STOP
620 ELSE
630 DISP "Call connected"
640 END IF
650 !
660 !***Set up measurement parameters***
670 OUTPUT A;"SETUP:DAPOWER:CONTINUOUS OFF" !Sets trigger arm state to single
680 OUTPUT A;"CALL:POW ";Ior !Sets Cell Power for the selected System Type
690 OUTPUT A;"CALL:CLPCONTROL:REVERSE:MODE UP" !Starts transmission of All Up (0) power
control bits
700 OUTPUT A;"CALL:PIL ";Pilot !Sets pilot channel level
710 OUTPUT A;"CALL:FCH ";Traffic !Sets traffic channel level
720 !
730 !***Obtain measurement results***
740 WAIT 1 !Settling time
750 OUTPUT A;"INITIATE:DAPOWER" !Initiates an Average Power measurement
810 OUTPUT A;"FETCh:DAPOWER?"
820 ENTER A;Integrity,Avg_power_dbm
830 Avg_power_dbw=Avg_power_dbm-30
840 !
850 !***Display measurements if the mobile station did not drop the call***
860 OUTPUT A;"CALL:STATUS?"
870 ENTER A;Call_status$
880 IF Call_status$="CONN" THEN
890 PRINT "Integrity indicator = ";Integrity
900 PRINT "Maximum power = ";Avg_power_dbm;"dBm";", ";Avg_power_dbw;"dBW"
910 ELSE
920 PRINT "Mobile station dropped call, invalid results"
930 END IF
940 !
950 !***Return to default call processing states***
960 OUTPUT A;"CALL:CLPCONTROL:REVERSE:MODE ACTIVE" ! Returns to active power control bits
970 OUTPUT A;"CALL:POW:DIG2000 -50" ! Returns cell power to -50 dBm/1.23 MHz
980 !
990 DISP "Test complete"
1000 OUTPUT A;"CALL:END"
1010 END
1020 Timeout: SUB Timeout
1030 PRINT "Program timed out"
1040 CLEAR 7
1050 CLEAR 714
1060 SUBEND
Returned Values
This program returns an integrity indicator followed by a digital average power measurement result (if results are available).
|