Agilent Technologies Home Page 8960 Series 10 Wireless Communications Test Set
- +
Home | Product Web Site | Contact Us
+
- -
+ -
8960 cdma2000 Online User's Guide
E1962B, E6702B
Search this guide for     
search tips



Feedback
Did the information on this web page help answer your question or solve a problem?

Yes
No
Did not apply

Please provide additional comments about this page.
(Optional, 255 character max)


Email address (optional):

Privacy Notice: We will not sell or give away your email address to any third party.

 



Maximum/Minimum Power Measurement Troubleshooting

Last updated: October 28, 2004

   
IMPORTANT
The maximum/minimum power measurement does not run concurrently with any other measurements. If any measurements are running, they are closed when Maximum/Minimum power measurement is initiated, and a message is displayed indicating that a measurement has been closed. Activating another measurement inactivates the maximum/minimum power measurement.

   

The Maximum/Minimum power measurement uses single triggering. Press the START SINGLE key to trigger each measurement. See Triggering of Measurements for details on trigger settings.

Troubleshooting Techniques

Check to see if an integrity indicator other than 0 (normal) was returned with a measurement result (see Integrity Indicator ).

  • If Over Range (5) is returned; the input power has exceeded +37 dBm or is greater than +9 dB above the expected power level of the receiver.
  • If Under Range (6) is returned; the input power is below -61 dBm or is less than -9 dB below the expected power level of the receiver.
  • If the signal has both over range and under range conditions, only the over range (5) will be indicated.
    Under Range/Over Range Integrity Indicators

Other Considerations




Top of pagetop of page     

+ +