TDSO Frame Error Rate (FER) Setup Issues
TDSO FER results may take up to 20.48 seconds to display
A call must be setup using one of the following service options:
-
SO32 (+F-SCH) or
-
SO32 (+ SCH)
If "No F-SCH" is displayed in the bottom right portion of the display, the supplemental channel is not connected.
The TDSO FER test returns the confidence level based on the average FER result obtained over the fixed frame count length. If the confidence level is less than 95% for the specified FER confidence requirement, the test has not passed minimum standards.
If the test set misses an FER results message from the mobile station, a GPIB query of that measurement will include the integrity indicator Call Processing Operation Failed.
|