This command sets/queries the active (that is the selected) format's confidence level (in %) with which to end the measurement early. This level applies to the RMS Phase Error, the Peak Phase Error, and the Frequency Error. For more information on using confidence levels refer to Confidence Levels . |
||
Setting | ||
*RST Setting | 99.00 | |
OUTPUT 714;"SETUP:PFERROR:CONFIDENCE:LEVel 90" ! Sets the confidence level to 90%. |
This command sets/queries the GSM format's confidence level (in %) with which to end the measurement early, whether or not the GSM format is active. This level applies to the RMS Phase Error, the Peak Phase Error, and the Frequency Error. For more information on using confidence levels refer to Confidence Levels . |
||
Setting | ||
*RST Setting | 99.00 | |
OUTPUT 714;"SETUP:PFERROR:CONFIDENCE:LEVEL:GSM 90" ! Sets the confidence level to 90%. |
This command sets/queries the active (that is the selected) format's confidence level with which to end the measurement early and turns the confidence state on. This level applies to the RMS Phase Error, the Peak Phase Error, and the Frequency Error. This command also turns the multi-measurement state on. For more information on using confidence levels refer to Confidence Levels . |
||
Setting | ||
*RST Setting | 99.00 | |
OUTPUT 714;"SETUP:PFERROR:CONFIDENCE 95" ! Sets the confidence level to 95% and the state to on. |
This command sets/queries the GSM format's confidence level with which to end the measurement early and turns the confidence state on. It does this in the GSM format whether or not that format is active. This level applies to the RMS Phase Error, the Peak Phase Error, and the Frequency Error. This command also turns the multi-measurement state on. For more information on using confidence levels refer to Confidence Levels . |
||
Setting | ||
*RST Setting | 99.00 | |
OUTPUT 714;"SETUP:PFERROR:CONFIDENCE:GSM 90" ! Sets the confidence level to 90% and the state to on. |
This command sets/queries whether the active (that is the selected) format's confidence level feature for the phase and frequency error measurement is on or off. This command also turns the multi-measurement state on. For more information on using confidence levels refer to Confidence Levels . |
||
Setting | ||
*RST Setting | 0 | OFF | |
OUTPUT 714;"SETUP:PFERROR:CONFIDENCE:STATE 1" ! Sets the confidence state on. |
This command sets/queries whether the GSM format's confidence level feature for the phase and frequency error measurement is on or off, whether or not that format is active. This command also turns the multi-measurement state on. For more information on using confidence levels refer to Confidence Levels . |
||
Setting | ||
*RST Setting | 0 | OFF | |
OUTPUT 714;"SETUP:PFERROR:CONFIDENCE:STATE:GSM OFF" ! Sets the confidence state off. |
This command sets/queries the burst synchronization mode for phase and frequency error measurements in the active (that is the selected) format. See Burst Synchronization of Measurements . |
||
Setting | ||
*RST Setting | MID | |
Requirements | ||
OUTPUT 714;"SETUP:PFERROR:SYNC MIDAMBLE" ! Selects burst synchronization to midamble for power versus time measurements. |
This command sets/queries the trigger source for phase and frequency error measurements in the active (that is the selected) format. See Phase and Frequency Error Measurement Description . |
||
Setting | ||
*RST Setting | ||
Requirements | ||
OUTPUT 714;"SETUP:PFERROR:TRIGGER:SOURCE AUTO" ! Sets trigger source to automatic. |
This command selects/queries the trigger qualifier for phase and frequency error measurements. See Trigger Qualification Description . |
||
GSM/GPRS LA | ||
Setting | ||
*RST Setting |
The *RST value of this command depends on the format that is currently active. For example, if the GSM format is currently active, the *RST value for this command is the same value as the equivalent command containing the :GSM format identifier. |
|
Requirements | ||
OUTPUT 714;"SETUP:PFERROR:TRIGGER:QUALIFIER OFF" ! Sets trigger qualifier state to off. |
This command selects/queries the trigger qualifier for phase and frequency error measurements in the GSM format whether or not that format is active. See Trigger Qualification Description . |
||
GPRS TA | This command is not applicable to GPRS. | |
EGPRS TA | This command is not applicable to EGPRS. | |
Setting | ||
*RST Setting | ||
OUTPUT 714;"SETUP:PFERROR:TRIGGER:QUALIFIER:GSM OFF" ! Sets trigger qualifier state to off. |