How Do I Configure the Test Set for My Test System?
Last updated: September 2, 2009
This section is
not
applicable to GPRS.
A. Configure instrument information and setup.
-
Press the
SYSTEM CONFIG
key.
-
Press the
Instrument Setup
(
F1
) key.
-
Change an Instrument Setup Value and then press the
Close Menu
(
F6
) key.
Always verify that the test set is responding to a new LAN IP Address by pinging the test set. If the test set does not respond to the ping, cycle power. This will ensure that the test set will respond to the new LAN IP Address.
B. Set amplitude offsets.
-
Press the
System Config
button on the right side of the screen.
-
Press the
RF IN/OUT Amptd Offset
(
F5
) key on the Configuration Summary screen shown in part A.
-
On the RF IN/OUT Amplitude Offset screen, press the
RF IN/OUT Amptd Offset Setup
(
F2
) key.
-
Enter the test frequencies and their associated amplitude offsets. Twenty test frequencies and amplitude offsets can be set.
-
Press the
Close Menu
(
F6
) key.
-
Press the
Return
(
F6
) key to return to the Configuration Summary screen.
C. Check the message log.
-
Press the
System Config
button on the right side of the screen.
-
Press the
Message Log
(
F7
) key and view the message log.
-
You can clear the message log by pressing
Clear Message Log
(
F10
)
-
Press the
Return
(
F12
) key.