Configure DTM Parameters
Enable/Disable Dual Transfer Mode
This procedure details how to enable/disable Dual Transfer Mode. The test set's default setting for this parameter is on. See
DTM Enable
for more information.
-
Press
Call Setup
.
-
Press
Operating Mode
(
F1
) and select
Cell Off
from the Operating Mode menu.
-
Press
Cell Info
(
F6
).
-
Press
Cell Operation
(
F1
). The Cell Operation menu is displayed in the center of the screen.
-
Use the knob to scroll down the menu options and find the
Dual Transfer Mode
parameter.
-
Press
Close Menu
(F6).
-
Press
Return
(F6).
-
Press
Operating Mode
(
F1
) and select an option that supports Dual Transfer Mode from the Operating Mode menu. See
Operating Considerations
to find which Operating Modes support Dual Transfer Mode.
Enable/Disable Enhanced Dual Transfer Mode
This procedure details how to enable/disable Enhanced Dual Transfer Mode. The test set's default setting for this parameter is
OFF
. See
Enhanced DTM Enable
for more information.
-
Press
Call Setup
.
-
Press
Operating Mode
(
F1
) and select
Cell Off
from the Operating Mode menu.
-
Press
Cell Info
(
F6
).
-
Press
Cell Operation
(
F1
). The Cell Operation menu is displayed in the center of the screen.
-
Use the knob to scroll down the menu options and find the
Dual Transfer Mode (Enhanced)
parameter.
-
Press
Close Menu
(F6).
-
Press
Return
(F6).
-
Press
Operating Mode
(
F1
) and select an option that supports Dual Transfer Mode from the Operating Mode menu. See
Operating Considerations
to find which Operating Modes support Dual Transfer Mode.
Configure DTM Measured Burst
This procedure details how to configure DTM Measured Burst. See
DTM Measured Burst
for more information.
-
Press
Call Setup
.
-
Press
PDTCH Parameters
(
F9
).
-
Press
More
on the bottom right side of the screen until menu
2 of 3
of
PDTCH Parms
is displayed.
-
Press Measured Burst (
F8
). Use the knob or the number key pad to highlight and change
DTM Measured Burst
.
Configure DTM Manual Unassigned USF
This procedure details how to configure DTM Manual Unassigned USF. See
DTM Manual Unassigned USF
for more information.
-
Press
Call Setup
.
-
-
Press
More
on the bottom left side of the screen until menu
2 of 3
of
Control
is displayed.
-
Press
Protocol Control
(
F4
).
-
Press
RLC/MAC
(
F2
).
-
Press
MAC Control
(
F2
). Use the knob or the number key pad to highlight and change the
Assigned USF Allocation
to a value less than
100%
. Change
Unassigned USF Mode
to
Manual USF
.
-
Use the knob or the number key pad to highlight and change
DTM Manual Unassigned USF.
Configure DTM Multislot Configuration
This procedure details how to configure immediate and deferred DTM Multislot Configuration. See
DTM Multislot Configuration
for more information.
Immediate DTM Multislot Configuration
-
Press
Call Setup
.
-
Press
PDTCH Parameters
(
F9
).
-
Press
More
on the bottom right side of the screen until menu
3 of 3
of
PDTCH Parms
is displayed.
-
Press DTM Parameters (
F7
). Use the knob or the number key pad to highlight and change
DTM Multislot Configuration
.
Deferred DTM Multislot Configuration
-
Press
Call Setup
.
-
Press
Handover Parameters
(
F10
).
-
Press
DTM Handover Setup
(
F9
).
-
Use the knob or the number key pad to highlight and change DTM Multislot Configuration.
Configure DTM Traffic Band
This procedure details how to configure immediate and deferred DTM Traffic Band. See
DTM Traffic Band
for more information.
Immediate DTM Traffic Band
-
Press
Call Setup
.
-
Press
PDTCH Parameters
(
F9
).
-
Press
More
on the bottom right side of the screen until menu
3 of 3
of
PDTCH Parms
is displayed.
-
Press DTM Parameters (
F7
). Use the knob or the number key pad to highlight and change
Traffic Band
.
Deferred DTM Traffic Band
-
Press
Call Setup
.
-
Press
Handover Parameters
(
F10
).
-
Press
DTM Handover Setup
(
F9
).
-
Use the knob or the number key pad to highlight and change Traffic Band.
Configure DTM Traffic Channel
This procedure details how to configure the immediate and deferred DTM Traffic Channel. See
DTM Traffic Channel
for more information.
Immediate DTM Traffic Channel
-
Press
Call Setup
.
-
Press
PDTCH Parameters
(
F9
).
-
Press
More
on the bottom right side of the screen until menu
3 of 3
of
PDTCH Parms
is displayed.
-
Press DTM Parameters (
F7
). Use the knob or the number key pad to highlight and change
Traffic Channel
.
Deferred DTM Traffic Channel
-
Press
Call Setup
.
-
Press
Handover Parameters
(
F10
).
-
Press
DTM Handover Setup
(
F9
).
-
Use the knob or the number key pad to highlight and change Traffic Channel.
Configure DTM Frequency Hopping
This procedure details how to configure immediate and deferred DTM Frequency Hopping. See
DTM Frequency Hopping
for more information.
Immediate DTM Frequency Hopping
-
Press
Call Setup
.
-
Press
PDTCH Parameters
(
F9
).
-
Press
More
on the bottom right side of the screen until menu
3 of 3
of
PDTCH Parms
is displayed.
-
Press DTM Parameters (
F7
). Use the knob or the number key pad to highlight and change
Frequency Hopping
.
Deferred DTM Frequency Hopping
-
Press
Call Setup
.
-
Press
Handover Parameters
(
F10
).
-
Press
DTM Handover Setup
(
F9
).
-
Use the knob or the number key pad to highlight and change Frequency Hopping.
Configure DTM Coding Scheme
This procedure details how to configure immediate and deferred DTM Coding Schemes. See
DTM Coding Schemes
for more information.
Immediate DTM Coding Scheme
-
Press
Call Setup
.
-
Press
PDTCH Parameters
(
F9
).
-
Press Coding Scheme (
F11
). Use the knob or the number key pad to highlight and change
DTM Coding Scheme
.
Deferred DTM Coding Scheme
-
Press
Call Setup
.
-
Press
Handover Parameters
(
F10
).
-
Press
DTM Handover Setup
(
F9
).
-
Use the knob or the number key pad to highlight and change Coding Scheme.
Configure DTM MS Tx Levels
This procedure details how to configure immediate and deferred DTM MS Tx Level for the individual bursts of the DTM connection. See
DTM MS Tx Levels
for more information.
Immediate DTM MS Tx Levels
-
Press
Call Setup
.
-
Press
PDTCH Parameters
(
F9
).
-
Press
More
on the bottom right side of the screen until menu
3 of 3
of
PDTCH Parms
is displayed.
-
Press DTM Parameters (
F7
). Use the knob or the number key pad to highlight and change
MS TX Level
for the individual bursts.
Deferred DTM MS Tx Levels
-
Press
Call Setup
.
-
Press
Handover Parameters
(
F10
).
-
Press
DTM Handover Setup
(
F9
).
-
Use the knob or the number key pad to highlight and change MS Tx Level for the individual bursts.
Configure DTM Power Reduction Reference
This procedure details how to configure immediate and deferred DTM Power Reduction Reference. See
DTM Power Reduction Reference
for more information.
Immediate DTM Power Reduction Reference
-
Press
Call Setup
.
-
Press
PDTCH Parameters
(
F9
).
-
Press Downlink Traffic Power(
F7
). Use the knob or the number key pad to highlight and change
DTM P0 (Power Reduction Reference)
.
Deferred DTM Power Reduction Reference
-
Press
Call Setup
.
-
Press
Handover Parameters
(
F10
).
-
Press
DTM Handover Setup
(
F9
).
-
Use the knob or the number key pad to highlight and change P0 (Power Reduction Reference).
Configure DTM Uplink State Flag
This procedure details how to configure immediate and deferred DTM Uplink State Flag. See
DTM Uplink State Flag
for more information.
Immediate DTM Uplink State Flag
-
Press
Call Setup
.
-
-
Press
More
on the bottom left side of the screen until menu
2 of 3
of
Control
is displayed.
-
Press
Protocol Control
(
F4
).
-
Press
RLC/MAC
(
F2
).
-
Press
MAC Control
(
F2
). Use the knob or the number key pad to highlight and change
DTM Uplink State Flag (USF)
.
Deferred DTM Uplink State Flag
-
Press
Call Setup
.
-
Press
Handover Parameters
(
F10
).
-
Press
DTM Handover Setup
(
F9
).
-
Use the knob or the number key pad to highlight and change Uplink State Flag.
Configure DTM CS Timeslot Position
The following procedures detail how to choose both immediate and deferred DTM CS Timeslot the test set will use. See
DTM CS Timeslot Position
for more information.
NOTE: You can only configure DTM CS Timeslot parameter when Multislot Config parameter setting is supported by DTM. For the list of multislot configurations that DTM supports, see
DTM Multislot Configuration
.
Immediate DTM CS Timeslot
-
Press
Call Setup
.
-
Press
PDTCH Parameters
(
F9
).
-
Press
More
on the bottom right side of the screen until menu
3 of 3
of
PDTCH Parms
is displayed.
-
Press DTM Parameters (
F7
). Use the knob or the number key pad to highlight and change DTM CS Timeslot.
Deferred DTM CS Timeslot
-
Press
Call Setup
.
-
Press
Handover Parameters
(
F10
).
-
Press
DTM Handover Setup
(
F9
).
-
Use the knob or the number key pad to highlight and change DTM CS Timeslot.
Configure DTM CS Half Rate Sub Channel
The following procedures detail how to choose both immediate and deferred DTM CS Timeslot the test set will use. See
DTM CS Half Rate Sub Channel
for more information.
Immediate DTM CS Half Rate Sub Channel
-
Press
Call Setup
.
-
Press
PDTCH Parameters
(
F9
).
-
Press
More
on the bottom right side of the screen until menu
3 of 3
of
PDTCH Parms
is displayed.
-
Press DTM Parameters (
F7
). Use the knob or the number key pad to highlight and change DTM CS Half Rate Sub Channel.
Deferred DTM Half Rate Sub Channel
-
Press
Call Setup
.
-
Press
Handover Parameters
(
F10
).
-
Press
DTM Handover Setup
(
F9
).
-
Use the knob or the number key pad to highlight and change DTM CS Half Rate Sub Channel.
Configure DTM CS MS TX Level
This procedure details how to configure DTM CS MS TX Level.
Immediate DTM CS MS TX Level
-
Press
Call Setup
.
-
Press
PDTCH Parameters
(
F9
).
-
Press
More
on the bottom right side of the screen until menu
3 of 3
of
PDTCH Parms
is displayed.
-
Press DTM Parameters (
F7
). Use the knob or the number key pad to highlight and change
DTM CS MS TX Level
.
Deferred DTM CS MS TX Level
-
Press
Call Setup
.
-
Press
Handover Parameters
(
F10
).
-
Press
DTM Handover Setup
(
F9
).
-
Use the knob or the number key pad to highlight and change DTM CS MS TX Level.
Configure Specific Features that Dual Transfer Mode Adds/Changes
The test set's display is slightly altered while the Dual Transfer Mode feature is enabled. The following procedures assumes that DTM is enabled and the Operating Mode is set to Active Cell (serving cell GPRS or EGPRS).
Choose the Connection Type
Dual Transfer Mode allows a circuit switched voice connection to be established in any connection type, thus the connection type only effects the data connection.
-
Press
CALL SETUP.
-
Press
Data Conn Type
(
F2
) and choose the type of data connection.
Establish a Mobile Terminated Data Connection
-
Press
CALL SETUP.
-
Press
Data Conn Type
(
F2
) on screen
1 of 2
of the
Control
menu.
-
Press
Start Data Connection
(
F4
).
Configure the Paging IMSI
-
Press
CALL SETUP
.
-
Press
Paging IMSI
(F5) on screen
1 of 3
of the
Control
menu.
Configure and Execute a Handover
The Handover Parameters are accessed from the Call Parms menu.
-
Press
CALL SETUP
.
-
Press
Handover Parameters
(
F10
).
-
Press
GSM Handover Setup
(
F7
) or
EGPRS Handover Setup
(
F8
).
-
Set the parameters in the Handover Setup menu.
-
Press
Handover Execute
(F5).