ABORt
Last updated: December 3, 2008
GPIB Command Conventions
ABORt[:ALL]
|
Function
|
GSM TA
|
Stops any and all measurements that are active. See
Measurement States
If the trigger arm is set to single, see
Trigger Arm (Single or Continuous) Description
the measurements will go to the idle state.
If the trigger arm is set to continuous the measurements will re-arm and initiate again.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA |
|
EGPRS LA
|
|
Requirements |
GSM/GPRS/
EGPRS TA |
Revision: A.01 and above
|
|
GSM/GPRS/ EGPRS LA |
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"ABORT:ALL"
! Aborts all active measurements in progress.
|
ABORt:<meas-mnemonic>
|
Function
|
GSM TA
|
Stops the selected measurement if it is active. See
Measurement States
If the trigger arm is set to single, see
Trigger Arm (Single or Continuous) Description
the measurements will go to the idle state.
If the trigger arm is set to continuous the measurements will re-arm and initiate again.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
meas-
mnemonic |
GSM TA |
Range:
AAUDio | BERRor | DAUDio | DPOWer | FBERror|FSTability | IQTuning | MTAudio | ORFSpectrum | PCALibration | PFERror | PVTime | SMONitor | TXPower
|
GPRS TA
|
Range:
BLERror | DPOWer |FSTability| GBERror | IQTuning | MTAudio | ORFSpectrum | PCALibration | PFERror | PVTime | SMONitor | TXPower
|
GSM/GPRS LA
|
Range:
AAUDio | BERRor | BLERror | DAUDio | DPOWer | FBERror|FSTability | GBERror | IQTuning | MTAudio | ORFSpectrum | PCALibration | PFERror | PVTime | SMONitor | TXPower|IFERror|BFI
|
|
EGPRS TA
|
Range:
AAUDio | BERRor | BLERror | DAUDio | DPOWer | EDPower|EMACcuracy | ETXPower | FBERror |FSTability| GBERror | IQTuning | MTAudio | ORFSpectrum | PCALibration | PFERror | PVTime | SBERror |SMONitor | TXPower
|
|
EGPRS LA
|
Range:
AAUDio | BERRor | BFINdication | BFI |BLERror | DAUDio | DPOWer | EDPower|EMACcuracy | ETXPower | FBERror | FFERate|FSTability| GBERror | IQTuning | MTAudio | ORFSpectrum | PCALibration | PFERror | PVTime | SBERror |SMONitor | TXPower|IFERror|BFI
|
|
Requirements |
GSM/GPRS/
EGPRS TA |
Revision: A.01 and above
Revision A.03 adds SBERror
Revision A.04 adds EDPower and FSTability
Revision A.06 adds PCALibration
|
|
GSM/GPRS/ EGPRS LA |
Revision: C.01 and above
Revision C.03 adds BFINdication, BFI, FFERate, and SBERror
Revision D.01 adds EDPower, FSTability and IFER.
Revision D.03 adds PCALibration
|
|
Programming Example
OUTPUT 714;"ABORT:PVTIME"
! Aborts a PvT measurement.
|
|