SETup:BERRor
Last updated: December 3, 2008
GPIB Command Conventions
SETup:BERRor[:TYPE]
|
Function
|
GSM TA
|
Sets the measurement type for BER measurements including Type A (residual), Type B (non-residual) and Type D (residual (D) )
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
GPRS TA
|
This command is not applicable to GPRS.
|
|
EGPRS TA |
This command is not applicable to EGPRS.
|
|
Setting |
GSM TA |
Range:
TYPEIA | TYPEII |TYPEIB | RESTYPEIA | RESTYPEII | RESTYPEIB
|
|
GSM/GPRS LA |
Range:
TYPEIA | TYPEII |TYPEIB | DATA |RESTYPEIA | RESTYPEII |
RESTYPEIB | RESDATA |RESTYPEIAD | RESTYPEIBD | RESTYPEIID |RESDATAD
|
|
Query
|
GSM TA |
Range:
TYPEIA | TYPEII |TYPEIB | RESTYPEIA | RESTYPEII | RESTYPEIB
|
|
GSM/GPRS LA |
Range:
TYPEIA | TYPEII |TYPEIB | DATA |RESTYPEIA | RESTYPEII |
RESTYPEIB | RESDATA |RESTYPEIAD | RESTYPEIBD | RESTYPEIID |RESDATAD
|
|
*RST Setting |
RESTYPEII
|
|
Requirements
|
GSM/GPRS/
EGPRS TA |
Revision: A.01 and above
|
|
GSM/GPRS/ EGPRS LA |
Revision: C.01 and above
Revision D.01 adds DATA and RESDATA to support CSD BER testing.
Revision F.00.27 adds RESTYPEIAD, RESTYPEIBD, RESTYPEIID and RESDATAD.
|
|
Programming Example
OUTPUT 714;"SETUP:BERROR:TYPE TYPEIA"
! Sets type of BER measurement.
|
SETup:BERRor:CLSDelay[:STIMe]
|
Function
|
GSM TA
|
Selects/queries the closed loop signalling delay time in seconds for Bit Error measurements and sets the delay state to ON. The units (S|MS) are optional, if no units are specified than units default to S.
The delay time defines how long the test set should wait before starting a BERR measurement. The downlink signalling operation must be completed and the test set must send a close loop command to the MS before the measurement can begin. The delay time allows time for the loop to close.
When a close loop message is set to the MS the closed loop signalling delay time will hold off the BERR measurement from starting for the specified time period.
|
|
GSM/GPRS TA
|
|
EGPRS LA
|
|
GPRS TA
|
This command is not applicable to GPRS.
|
|
EGPRS TA |
This command is not applicable to EGPRS.
|
|
Setting |
Range: 0 to 5 seconds
Resolution: 100 ms
|
|
Query
|
Range: 0 to 5 seconds
Resolution: 100 ms
|
|
*RST Setting |
500 ms |
|
Requirements
|
GSM/GPRS/
EGPRS TA |
Revision: A.01 and above
|
|
GSM/GPRS/ EGPRS LA |
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:BERROR:CLSDELAY:STIME 400 MS"
! Set state to on and delay time
|
SETup:BERRor:CLSDelay:TIME
|
Function
|
GSM TA
|
Selects/queries the closed loop signalling delay time in seconds for Bit Error measurements. The units (S|MS) are optional, if no units are specified than units default to S.
The delay time defines how long the test set should wait before starting a BERR measurement. The downlink signalling operation must be completed and the test set must send a close loop command to the MS before the measurement can begin. The delay time allows time for the loop to close.
When a close loop message is set to the MS the closed loop signalling delay time will hold off the BERR measurement from starting for the specified time period.
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
GPRS TA |
This command is not applicable to GPRS.
|
|
EGPRS TA |
This command is not applicable to EGPRS.
|
|
Setting |
Range: 0 to 5 seconds
Resolution: 100 ms
|
|
Query
|
Range: 0 to 5 seconds
Resolution: 100 ms
|
|
*RST Setting |
500 ms |
|
Requirements
|
GSM/GPRS/
EGPRS TA |
Revision: A.01 and above
|
|
GSM/GPRS/ EGPRS LA |
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:BERROR:CLSDELAY:TIME 600MS"
! Set delay time
|
SETup:BERRor:CLSDelay:STATe
|
Function
|
GSM TA
|
Selects/queries the closed loop signalling delay state for Bit Error measurements. If the state is off the test set will not wait to start a BERR measurement after a downlink signalling operation has completed.
The delay time defines how long the test set should wait before starting and BERR measurement after a downlink signalling operation has completed and after the test set has sent a close loop command to the MS.
When a close loop message is set to the MS the closed loop signalling delay time will hold off the BERR measurement from starting for the specified time period.
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
GPRS TA |
This command is not applicable to GPRS.
|
|
EGPRS TA |
This command is not applicable to EGPRS.
|
|
Setting |
Range: 1 | ON
|
0 | OFF |
|
Query
|
Range: 1 | 0
|
|
*RST Setting |
1 | ON |
|
Requirements
|
GSM/GPRS/
EGPRS TA |
Revision: A.01 and above
|
|
GSM/GPRS/ EGPRS LA |
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:BERROR:CLSDELAY:STATE ON"
|
SETup:BERRor:CONTinuous
|
Function
|
GSM TA
|
Sets/queries the trigger state to single trigger mode or continuous trigger mode for BER measurement.
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
GPRS TA
|
This command is not applicable to GPRS.
|
|
EGPRS TA |
This command is not applicable to EGPRS.
|
|
Setting |
Range: 0 | OFF | 1 | ON
|
|
Query
|
Range: 0 | 1
|
|
*RST Setting |
0 | OFF
|
|
Requirements
|
GSM/GPRS/
EGPRS TA |
Revision: A.01 and above
|
|
GSM/GPRS/ EGPRS LA |
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETup:BERROR:CONTINUOUS OFF"
! Sets BER measurement to single trigger mode.
|
SETup:BERRor:COUNt
|
Function
|
GSM TA
|
Sets/queries the number of BER measurements the test set will make when the count state is on
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
GPRS TA
|
This command is not applicable to GPRS.
|
|
EGPRS TA |
This command is not applicable to EGPRS.
|
|
Setting |
Range: 1 to 999,000
Resolution: 1
|
|
Query
|
Range: 1 to 999,000
Resolution: 1
|
|
*RST Setting |
10,000
|
|
Requirements
|
GSM/GPRS/
EGPRS TA |
Revision: A.01 and above
|
|
GSM/GPRS/ EGPRS LA |
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:BERROR:COUNT 880"
! Set BER multi-measurement count to 880.
|
SETup:BERRor:LDControl:AUTO
|
Function
|
GSM TA
|
Sets/queries loopback delay control mode. If loopback delay control mode is automatic (Auto), the test set determines the loopback delay value that will allow correlation between uplink information bits with downlink information bits.
If loopback delay control mode is manual (not Auto), the test set will use the loopback delay value entered in the Loopback Delay field. Refer to. see
SETup:BERRor:MANual:DELay
Refer also to the
Bit Error Measurement
for a description of loopback delay and its use in the BER measurement.
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
GPRS TA
|
This command is not applicable to GPRS.
|
|
EGPRS TA |
This command is not applicable to EGPRS.
|
|
Setting |
Range: 0 | OFF | 1 | ON
|
|
Query
|
0 | 1
|
|
*RST Setting |
1 (automatic)
|
|
Related Topics
|
SETup:BERRor:MANual:DELay
|
|
Requirements
|
GSM/GPRS/
EGPRS TA |
Revision: A.01 and above
|
|
GSM/GPRS/ EGPRS LA |
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:BERROR:LDCONTROL:AUTO OFF"
! sets BER delay to manual the user must select the manual frame delay number.
|
SETup:BERRor:MANual:DELay
|
Function
|
GSM TA
|
Sets/queries the number of frames the test set uses to correlate uplink information bits with downlink information bits when loopback delay control mode is manual (AUTO OFF). To set the loopback delay mode to manual, refer to
SETup:BERRor:LDControl:AUTO
.
This value is displayed in the Loopback Delay field when Auto is not displayed. (If you want to display this value and Auto is currently displayed, press the front-panel key labeled
OFF
).
Refer to
Bit Error Measurement
for a description of loopback delay and how it is used in this measurement.
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
GPRS TA
|
This command is not applicable to GPRS.
|
|
EGPRS TA |
This command is not applicable to EGPRS.
|
|
Setting |
Range: 1 to 15
Resolution : 1
|
|
Query
|
Range: 1 to 15
Resolution : 1
|
|
*RST Setting |
5
|
|
Requirements
|
GSM/GPRS/
EGPRS TA |
Revision: A.01 and above
|
|
GSM/GPRS/ EGPRS LA |
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:BERROR:MANUAL:DELAY 4"
! Set delay of 4 speech frames.
|
SETup:BERRor:SLControl[:STATe]
|
Function
|
GSM TA
|
Selects/queries the Signalling loopback control state for an BER measurement.
When signalling loopback control is set to on, the test set will automatically send the loopback for Type A (residual) or Type B (non-residual) loopback to the MS, based on the measurement type selected, and then set loopback to off when the measurement is complete.
The loopback type is controlled manually using
Mobile Loopback
(
F12
) on
Call Parms
menu
1 of 4
. See
CALL:TCHannel:LOOPback
for a programming example and details about the command.
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
GPRS TA
|
This command is not applicable to GPRS.
|
|
EGPRS TA |
This command is not applicable to EGPRS.
|
|
Setting |
Range: 1 | ON | 0 | OFF
|
|
Query
|
Range: 1 | 0
|
|
*RST Setting |
1 | ON |
|
Requirements
|
GSM/GPRS/
EGPRS TA |
Revision: A.01 and above
|
|
GSM/GPRS/ EGPRS LA |
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:BERROR:SLCONTROL ON"
! Test set will send loopback type automatically
|
SETup:BERRor:TIMeout[:STIMe]
|
Function
|
GSM TA
|
Sets/queries the timeout value in seconds for the trigger state during BER measurements and turns the timeout state on. The units (S|MS) are optional, if no units are specified than units default to S.
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
GPRS TA
|
This command is not applicable to GPRS.
|
|
EGPRS TA |
This command is not applicable to EGPRS.
|
|
Setting |
Range: 0.1 to 999
Resolution: 0.1
|
|
Query
|
Range: 0.1 to 999Resolution: 0.1
|
|
*RST Setting |
10 seconds
|
|
Requirements
|
GSM/GPRS/
EGPRS TA |
Revision: A.01 and above
|
|
GSM/GPRS/ EGPRS LA |
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:BERR:TIMEOUT:STIME 8"
! Sets BER measurement timeout to 8 seconds and the state to on.
|
SETup:BERRor:TIMeout:TIME
|
Function
|
GSM TA
|
Sets/queries the timeout value in seconds for the trigger state during BER measurements. The units (S|MS) are optional, if no units are specified than units default to S (seconds).
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
GPRS TA
|
This command is not applicable to GPRS.
|
|
EGPRS TA |
This command is not applicable to EGPRS.
|
|
Setting |
Range: 0.1 to 999
Resolution: 0.1
|
|
Query
|
Range: 0.1 to 999Resolution: 0.1
|
|
*RST Setting |
10 seconds
|
|
Requirements
|
GSM/GPRS/
EGPRS TA |
Revision: A.01 and above
|
|
GSM/GPRS/ EGPRS LA |
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:BERR:TIMEOUT:TIME 8"
! Sets BER measurement timeout to 8 seconds.
|
SETup:BERRor:TIMeout:STATe
|
Function
|
GSM TA
|
Sets/queries the timeout state for BER measurements.
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
GPRS TA
|
This command is not applicable to GPRS.
|
|
EGPRS TA |
This command is not applicable to EGPRS.
|
|
Setting |
Range: 0 | OFF | 1 | ON
|
|
Query
|
Range: 0 | 1
|
|
*RST Setting |
0 | OFF
|
|
Requirements
|
GSM/GPRS/
EGPRS TA |
Revision: A.01 and above
|
|
GSM/GPRS/ EGPRS LA |
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:BERR0R:TIMEOUT:STATE ON"
! Sets the timeout state to on.
|
|