SETup:PFERror
Last updated: December 3, 2008
GPIB Command Conventions
SETup:PFERror:CONFidence:LEVel[:SELected]
|
Function
|
GSM TA
|
This command sets/queries the active (that is the selected) format's confidence level (in %) with which to end the measurement early. This level applies to the RMS Phase Error, the Peak Phase Error, and the Frequency Error.
For more information on using confidence levels refer to
Confidence Levels
.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
Setting |
Range: 80.00 to 99.99
Resolution: 0.01
|
|
Query
|
Range: 80.00 to 99.99
Resolution: 0.01
|
|
*RST Setting |
99.00 |
|
Requirements
|
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:CONFIDENCE:LEVel 90"
! Sets the confidence level to 90%.
|
SETup:PFERror:CONFidence:LEVel:GSM
|
Function
|
GSM TA
|
This command sets/queries the GSM format's confidence level (in %) with which to end the measurement early, whether or not the GSM format is active. This level applies to the RMS Phase Error, the Peak Phase Error, and the Frequency Error.
For more information on using confidence levels refer to
Confidence Levels
.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
Setting |
Range: 80.00 to 99.99
Resolution: 0.01
|
|
Query
|
Range: 80.00 to 99.99
Resolution: 0.01
|
|
*RST Setting |
99.00 |
|
Requirements
|
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:CONFIDENCE:LEVEL:GSM 90"
! Sets the confidence level to 90%.
|
SETup:PFERror:CONFidence[:SLEVel][:SELected]
|
Function
|
GSM TA
|
This command sets/queries the active (that is the selected) format's confidence level with which to end the measurement early and turns the confidence state on. This level applies to the RMS Phase Error, the Peak Phase Error, and the Frequency Error.
This command also turns the multi-measurement state on.
For more information on using confidence levels refer to
Confidence Levels
.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
Setting |
Range: 80.00 to 99.99
Resolution: 0.01
|
|
Query
|
Range: 80.00 to 99.99
Resolution: 0.01
|
|
*RST Setting |
99.00 |
|
Requirements
|
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:CONFIDENCE 95"
! Sets the confidence level to 95% and the state to on.
|
SETup:PFERror:CONFidence[:SLEVel]:GSM
|
Function
|
GSM TA
|
This command sets/queries the GSM format's confidence level with which to end the measurement early and turns the confidence state on. It does this in the GSM format whether or not that format is active. This level applies to the RMS Phase Error, the Peak Phase Error, and the Frequency Error.
This command also turns the multi-measurement state on.
For more information on using confidence levels refer to
Confidence Levels
.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
Setting |
Range: 80.00 to 99.99
Resolution: 0.01
|
|
Query
|
Range: 80.00 to 99.99
Resolution: 0.01
|
|
*RST Setting |
99.00 |
|
Requirements
|
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:CONFIDENCE:GSM 90"
! Sets the confidence level to 90% and the state to on.
|
SETup:PFERror:CONFidence:STATe[:SELected]
|
Function
|
GSM TA
|
This command sets/queries whether the active (that is the selected) format's confidence level feature for the phase and frequency error measurement is on or off.
This command also turns the multi-measurement state on.
For more information on using confidence levels refer to
Confidence Levels
.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
Setting |
Range: 0 | OFF | 1 | ON
|
|
Query
|
Range: 0 | 1
|
|
*RST Setting |
0 | OFF |
|
Requirements
|
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:CONFIDENCE:STATE 1"
! Sets the confidence state on.
|
SETup:PFERror:CONFidence:STATe:GSM
|
Function
|
GSM TA
|
This command sets/queries whether the GSM format's confidence level feature for the phase and frequency error measurement is on or off, whether or not that format is active.
This command also turns the multi-measurement state on.
For more information on using confidence levels refer to
Confidence Levels
.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
Setting |
Range: 0 | OFF | 1 | ON
|
|
Query
|
Range: 0 | 1
|
|
*RST Setting |
0 | OFF |
|
Requirements
|
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:CONFIDENCE:STATE:GSM OFF"
! Sets the confidence state off.
|
SETup:PFERror:CONTinuous
|
Function
|
GSM TA
|
This command sets/queries the trigger state for phase and frequency error measurements.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
Setting |
Range:
-
Single trigger mode = 0 | OFF
-
Continuous trigger mode = 1 | ON
|
|
Query
|
Range: 0 | 1
|
|
*RST Setting |
0 | OFF
|
|
Requirements |
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:CONTINUOUS OFF"
! Specifies single trigger mode for phase/frequency measurements.
|
SETup:PFERror:COUNt[:SNUMber]
|
Function
|
GSM TA
|
This command sets/queries the number of phase and frequency error measurements the test set will make and turns the multi-measurement count state on.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
Setting |
Range: 1 to 999
Resolution: 1
|
|
Query
|
Range: 1 to 999
Resolution: 1
|
|
*RST Setting |
0 | OFF |
|
Requirements |
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:COUNT:SNUMBER 100"
! Sets the value to 100 and the state to on.
|
SETup:PFERror:COUNt:NUMBer
|
Function
|
GSM TA
|
This command sets/queries the number of phase and frequency error measurements the Test Set will make when the multi-measurement count state is on.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
Setting |
Range: 1 to 999
Resolution: 1
|
|
Query
|
Range: 1 to 999
Resolution: 1
|
|
*RST Setting |
10
|
|
Requirements |
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:COUNT:NUMBER 55"
! Sets the multi-measurement count value to 55.
|
SETup:PFERror:COUNt:STATe
|
Function
|
GSM TA
|
This command sets/queries the phase and frequency error multi-measurement count state.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
Setting |
Range: 0 | OFF | 1 | ON
|
|
Query
|
0 | 1
|
|
*RST Setting |
0 | OFF
|
|
Requirements |
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:COUNT:STATE ON"
! Turns on multi-measurement mode for the phase/frequency measurement.
|
SETup:PFERror:FERRor[:LIMit]:GSM
|
Function
|
GSM TA
|
This command sets/queries the frequency error limit (in ppm) in the GSM format whether or not that format is active.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
Setting |
Range: 0.01 to 0.1
Resolution: 0.01
|
|
Query
|
Range: 0.01 to 0.1
Resolution: 0.01
|
|
*RST Setting |
0.1
|
|
Requirements
|
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:FERROR:GSM 0.05"
! Sets the frequency error limit to 0.05 ppm.
|
SETup:PFERror:FERRor[:LIMit][:SELected]
|
Function
|
GSM TA
|
This command sets/queries the frequency error limit (in ppm) in the active (that is currently selected) format.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
Setting |
Range: 0.01 to 0.1
Resolution: 0.01
|
|
Query
|
Range: 0.01 to 0.1
Resolution: 0.01
|
|
*RST Setting |
0.1
|
|
Requirements
|
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:FERROR 0.1"
! Sets the frequency error limit to 0.1 ppm.
|
SETup:PFERror:PEAK[:LIMit]:GSM
|
Function
|
GSM TA
|
This command sets/queries the peak phase error limit (in degrees) in the GSM format whether or not that format is active.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
Setting |
Range: 0.00 to 20.00
Resolution: 0.01
|
|
Query
|
Range: 0.00 to 20.00
Resolution: 0.01
|
|
*RST Setting |
20.00
|
|
Requirements
|
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:PEAK:GSM 15"
! Sets the peak phase error to 15 degrees.
|
SETup:PFERror:PEAK[:LIMit][:SELected]
|
Function
|
GSM TA
|
This command sets/queries the peak phase error limit (in degrees) in the active (that is currently selected) format.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
Setting |
Range: 0.00 to 20.00
Resolution: 0.01
|
|
Query
|
Range: 0.00 to 20.00
Resolution: 0.01
|
|
*RST Setting |
20.00
|
|
Requirements
|
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:PEAK 18"
! Sets the peak phase error to 18 degrees.
|
SETup:PFERror:RMS[:LIMit]:GSM
|
Function
|
GSM TA
|
This command sets/queries the RMS phase error limit (in degrees) in the GSM format whether or not that format is active.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
Setting |
Range: 0.00 to 5.00
Resolution: 0.01
|
|
Query
|
Range: 0.00 to 5.00
Resolution: 0.01
|
|
*RST Setting |
5.00
|
|
Requirements
|
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:RMS:GSM 3"
! Sets the RMS phase error to 3 degrees.
|
SETup:PFERror:RMS[:LIMit][:SELected]
|
Function
|
GSM TA
|
This command sets/queries the RMS phase error limit (in degrees) in the active (that is currently selected) format.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
Setting |
Range: 0.00 to 5.00
Resolution: 0.01
|
|
Query
|
Range: 0.00 to 5.00
Resolution: 0.01
|
|
*RST Setting |
5.00
|
|
Requirements
|
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:RMS 3.5"
! Sets the RMS phase error to 3.5 degrees.
|
SETup:PFERror:SYNC
|
Function
|
GSM TA
|
This command sets/queries the burst synchronization mode for phase and frequency error measurements in the active (that is the selected) format. See
Burst Synchronization of Measurements
.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
Setting |
MIDamble | AMPLitude | NONE
|
|
Query
|
MID | AMPL | NONE
|
|
*RST Setting |
MID |
|
Requirements |
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:SYNC MIDAMBLE"
! Selects burst synchronization to midamble for power versus time measurements.
|
SETup:PFERror:TBDemod
|
Function
|
GSM TA
|
This command sets/queries the Tail Bit Demodulation parameter. This parameter determines how the measurement performs demodulation of the tail bits.
-
OPTimal
The guard bits are adjusted to values that minimize the phase error on the tail bits.
-
SIMPle
The guard bits are demodulated as they are received. The values are not adjusted.
-
ETSI
The tail bits are forced to be ETSI compliant. That is, all the tail bits are set to zero, rather than using the demodulated values.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
Setting |
OPTimal|SIMPle|ETSI |
|
Query
|
OPT|SIMP|ETSI
|
|
*RST Setting |
OPT |
|
Requirements
|
GSM/GPRS/
EGPRS TA
|
Revision: A.06.20 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: D.03 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:TBDemod OPTimal"
! Sets the Tail Bit Demodulation parameter to OPTimal.
|
SETup:PFERror:TIMeout[:STIMe]
|
Function
|
GSM TA
|
This command sets/queries the phase and frequency error measurement timeout value in seconds and sets the timeout state to on in the active (that is the selected) format. The units (S|MS) are optional, if no units are specified then unit default to S (seconds).
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
Setting |
Range: 0.1 to 999 seconds
Resolution: 0.1 seconds
|
|
Query
|
Range: 0.1 to 999 seconds
Resolution: 0.1 seconds
|
|
*RST Setting |
10 seconds
|
|
Requirements |
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:TIMEOUT:STIME 3"
! Sets the timeout state to on and the timeout value to 3 seconds.
|
SETup:PFERror:TIMeout:TIME
|
Function
|
GSM TA
|
This command sets/queries the timeout value in seconds that will be used for phase and frequency error measurements when the timeout state is ON in the active (that is the selected) format. The units (S|MS) are optional, if no units are specified then unit default to S (seconds).
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
Setting |
Range: 0.1 to 999 seconds
Resolution: 0.1 seconds
|
|
Query
|
Range: 0.1 to 999 seconds
Resolution: 0.1 seconds
|
|
*RST Setting |
10 seconds |
|
Requirements |
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:TIMEOUT:TIME 4"
! Sets the timeout value to 4 seconds.
|
SETup:PFERror:TIMeout:STATe
|
Function
|
GSM TA
|
This command selects/queries the timeout state for a phase and frequency error measurement in the active (that is the selected) format.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
Setting |
0 | OFF | 1 | ON
|
|
Query
|
0 | 1
|
|
*RST Setting |
0 | OFF |
|
Requirements |
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:TIMEOUT:STATE ON"
! Sets the timeout state to on for a Phase/Frequency measurement.
|
SETup:PFERror:TRIGger:DELay
|
Function
|
GSM TA
|
This command sets/queries the trigger delay time in seconds for a phase and frequency error measurement in the active (that is the selected) format. The units (S|MS|US|NS) are optional, if no units are specified then units default to S (seconds).
See
Phase and Frequency Error Measurement Description
.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
Setting |
Range: -2.31 ms to +2.31 ms
Resolution: 5 significant digits or 100 ns, whichever is greater
|
|
Query
|
Range: -2.31 ms to +2.31 ms
Resolution: 5 significant digits or 100 ns, whichever is greater
|
|
*RST Setting |
0 seconds
|
|
Requirements |
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:TRIGGER:DELAY 1.2MS"
! Sets trigger delay time to 1.2 milliseconds
|
SETup:PFERror:TRIGer:SOURce
|
Function
|
GSM TA
|
This command sets/queries the trigger source for phase and frequency error measurements in the active (that is the selected) format. See
Phase and Frequency Error Measurement Description
.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
Setting |
AUTO | PROTocol | RISE | IMMediate
See
Triggering of Measurements
.
|
|
Query
|
AUTO | PROT | RISE | IMM
|
|
*RST Setting |
AUTO
|
|
Requirements |
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:TRIGGER:SOURCE AUTO"
! Sets trigger source to automatic.
|
SETup:PFERror:TRIGger:QUALifier[:SELected]
|
Function
|
GSM TA
|
This command selects/queries the trigger qualifier for phase and frequency error measurements. See
Trigger Qualification Description
.
|
|
GPRS TA
|
|
EGPRS TA
|
|
GSM/GPRS LA |
|
EGPRS LA
|
|
Setting |
Range: 0 | OFF | 1 | ON
|
|
Query
|
Range: 0 | 1
|
|
*RST Setting |
The *RST value of this command depends on the format that is currently active. For example, if the GSM format is currently active, the *RST value for this command is the same value as the equivalent command containing the :GSM format identifier.
|
|
Requirements |
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:TRIGGER:QUALIFIER OFF"
! Sets trigger qualifier state to off.
|
SETup:PFERror:TRIGger:QUALifier:GSM
|
Function
|
GSM TA
|
This command selects/queries the trigger qualifier for phase and frequency error measurements in the GSM format whether or not that format is active. See
Trigger Qualification Description
.
|
|
GSM/GPRS LA
|
|
EGPRS LA
|
|
GPRS TA |
This command is not applicable to GPRS. |
|
EGPRS TA |
This command is not applicable to EGPRS. |
|
Setting |
Range: 0 | OFF | 1 | ON
|
|
Query
|
Range: 0 | 1
|
|
*RST Setting |
1 | ON
|
|
Requirements
|
GSM/GPRS/
EGPRS TA
|
Revision: A.01 and above
|
|
GSM/GPRS/
EGPRS LA
|
Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:PFERROR:TRIGGER:QUALIFIER:GSM OFF"
! Sets trigger qualifier state to off.
|
|
|