SETup:DEHich

For more information on the GPIB Command conventions, see GPIB Command conventions

For the measurement, see Detection of E-DCH HARQ ACK Indicator Channel

SETup:DEHich:CONTinuous

Function

Sets/queries the trigger arm state for the Detection of E-DCH HARQ ACK Indicator Channel measurement. The trigger arm state determines whether the measurement will be made once then stop (0|OFF (single)), or automatically re-arm upon completion of one measurement and repeat the process (1|ON (continuous)).

Setting

Range: 1|ON|0|OFF

Query

Range: 1|0

*RST Setting

0 (OFF)

Requirements

Test Application Revision: A.08.00 and above

Programming Example

"SETup:DEHich:CONTinuous OFF"

SETup:DEHich:COUNt

Function

Sets/queries the Number_of_Events_to_test.

Setting

Range: 1000 to 99000

Resolution: 1

Query

Same as setting

*RST Setting

1000

Requirements

Test Application Revision: A.08.00 and above

Programming Example

"SETup:DEHich:COUNt 1000"

SETup:DEHich:TIMeout[:STIMe]

Function

The command delivers two functions: (1) sets the Detection of E-DCH HARQ ACK Indicator Channel measurement's timeout value, and (2) sets the Detection of E-DCH HARQ ACK Indicator Channel measurement's timeout state to 1 (on).

The query form returns the Detection of E-DCH HARQ ACK Indicator Channel measurement's timeout value.

Setting

Range: 0.1 to 999.9 seconds

Unit: S | MS | US | NS

Query

Same as setting

*RST Setting

10 s, On

Requirements

Test Application Revision: A.08.00 and above

Programming Example

"SETup:DEHich:TIMeout:STIMe 20s"

SETup:DEHich:TIMeout:STATe

Function

Sets/Queries the Detection of E-DCH HARQ ACK Indicator Channel measurement's timeout state.

Setting

Range: 1|ON|0|OFF

Query

Range: 1|0

*RST Setting

 0(OFF)

Requirements

Test Application Revision: A.08.00 and above

Programming Example

"SETup:DEHich:TIMeout:STATe ON"

SETup:DEHich:TIMeout:TIME

Function

Sets/queries the Detection of E-DCH HARQ ACK Indicator Channel measurement's timeout.

Setting

Range: 0.1 to 999.9 seconds

Resolution: 0.1 second

Unit: S | MS | US | NS

Query

Range: 0.1 to 999.9

*RST Setting

10 s

Requirements

Test Application Revision: A.08.00 and above

Programming Example

"SETup:DEHich:TIMeout:TIME 5S"