34.121 Preset Call Configurations

Last updated: January 15, 2009

This section is only applicable to the lab application or feature-licensed test application.

The 34.121 Preset Call Configurations make it much simpler to configure the test set for 3GPP TS 34.121 HSPA tests from the front panel (the 34.121 Preset Call Configurations are only available from the front panel; there are no GPIB commands to configure these presets).

   
NOTE
To move between the preset configurations or between sub-tests while on a call, you must use the Transport Channel Reconfiguration to change the parameters that differ between the different preset configurations and sub-tests.

   

Operating Mode must be set to Cell Off before selecting one of the 34.121 preset call configurations.

HSDPA 34.121 Preset Call Configurations

The presets configure the test set as per 3GPP TS 34.121 v7.5.0. All presets configure the test set for 3GPP TS 34.121 v7.5.0 Table C.10.1.4 sub-test 3.

HSDPA 34.121 Preset Call Configurations

5.2A, 5.2AA, 5.9A, 5.10A with QPSK 5.2C, 5.7A, 5.13.1A, 5.13.1AA, 5.13.2A with QPSK 6.3A with 16QAM 5.2A, 5.2AA, 5.9A, 5.10A with 16QAM 5.2C, 5.7A, 5.13.1A, 5.13.1AA, 5.13.2A with 16QAM

Call Parameters:

Channel Type

12.2k RMC + HSDPA

12.2k RMC + HSDPA

12.2k RMC + HSDPA

12.2k RMC + HSDPA

12.2k RMC + HSDPA

UL CL Power Ctrl Algorithm

Algorithm 2

Algorithm 2

Algorithm 2

Algorithm 2

Algorithm 2

HSDPA Parameters:

RB Test HS-DSCH Configuration Type

FRC

FRC

FRC

FRC

FRC

FRC Type

H-Set 1 QPSK

H-Set 1 QPSK

H-Set 1 16QAM

H-Set 1 16QAM

H-Set 1 16QAM

Number of Transmissions

4

4

1

4

4

RV Sequence

0,2,5,6,0,0,0,0 0,2,5,6,0,0,0,0

6,0,0,0,0,0,0,0

6,2,1,5,0,0,0,0

6,2,1,5,0,0,0,0

DeltaACK

8

8

8

8

8

DeltaNACK

8 8 8 8 8

DeltaCQI

8

7

8

8

7

Ack-Nack Repetition Factor

3

1

3

3

1

CQI Feedback Cycle (k)

4 ms

4 ms

4 ms

4 ms

4 ms

CQI Repetition Factor

2

1

2

2

1

Cell Parameters:

Default DPCH Offset (DOFF)

3 x 512 chips

3 x 512 chips

3 x 512 chips

3 x 512 chips

3 x 512 chips

Generator Info:

HSDPA Cell 1 Connected CPICH Level

-10 dB

-10 dB

-10 dB

-10 dB

-10 dB

HSDPA Cell 1 Connected DPCH Level

-9 dB -9 dB -9 dB -9 dB -9 dB

HSDPA Cell 1 Connected PICH Level

-15 dB

-15 dB

-15 dB

-15 dB

-15 dB

HSDPA Cell 1 Connected P-CCPCH/SCH Level

-12 dB

-12 dB

-12 dB

-12 dB

-12 dB

HSDPA Cell 1 Connected HS-PDSCHs Level (Sum)

-3 dB

-3 dB

-3 dB

-3 dB

-3 dB

HSDPA Cell 1 Connected HS-SCCH 1 Level

-8 dB

-8 dB

-8 dB

-8 dB

-8 dB

HSDPA Cell 1 Connected HS-SCCH 2 Level State Off Off Off Off Off
HSDPA Cell 1 Connected HS-SCCH 3 Level State Off Off Off Off Off
HSDPA Cell 1 Connected HS-SCCH 4 Level State Off Off Off Off Off

Uplink Parameters:

Uplink DPCH Bc/Bd Control

Manual

Manual

Manual

Manual

Manual

Manual Uplink DPCH Bc

15 15 15 15 15

Manual Uplink DPCH Bd

8

8

8

8

8

RB Test Mode Setup:

Maximum Uplink Transmit Power Level

+21 dBm

+21 dBm

+21 dBm

+21 dBm

+21 dBm

UE Loopback Type

Type 1

Type 1

Type 1

Type 1

Type 1

HSPA 34.121 Preset Call Configurations

The presets configure the test set as per 3GPP TS 34.121 v7.5.0. All presets configure the test set for 3GPP TS 34.121 v7.5.0 Table C.11.1.3 sub-test 1.

HSPA 34.121 Preset Call Configurations

5.2B, 5.9B, 5.10B, 5.13.2B with QPSK 5.2D with QPSK

Call Parameters:

Channel Type

12.2k RMC + HSPA

12.2k RMC + HSDPA

UL CL Power Ctrl Algorithm

Algorithm 2

Algorithm 2

HSDPA Parameters:

RB Test HS-DSCH Configuration Type

FRC

FRC

FRC Type

H-Set 1 QPSK

H-Set 1 QPSK

Number of Transmissions

4

4

RV Sequence

0,2,5,6,0,0,0,0 0,2,5,6,0,0,0,0

DeltaACK

8

8

DeltaNACK

8 8

DeltaCQI

8

8

Ack-Nack Repetition Factor

3

3

CQI Feedback Cycle (k)

4 ms

4 ms

CQI Repetition Factor

2

2

Generator Info:

HSPA Cell 1 Connected CPICH Level

-10 dB

-10 dB

HSPA Cell 1 Connected P-CCPCH/SCH Level

-12 dB

-12 dB

HSPA Cell 1 Connected PICH Level

-15 dB

-15 dB

HSPA Cell 1 Connected DPCH Level

-10 dB -10 dB
HSPA Cell 1 Connected E-AGCH Level -20 dB -20 dB
HSPA Cell 1 Connected E-HICH Level -20 dB -20 dB
HSPA Cell 1 Connected E-RGCH Level Off Off

HSPA Cell 1 Connected HS-PDSCHs Level (Sum)

-3 dB

-3 dB

HSPA Cell 1 Connected HS-SCCH 1 Level

-8 dB

-8 dB

HSPA Cell 1 Connected HS-SCCH 2 Level State Off Off
HSPA Cell 1 Connected HS-SCCH 3 Level State Off Off
HSPA Cell 1 Connected HS-SCCH 4 Level State Off Off

Uplink Parameters:

Uplink DPCH Bc/Bd Control

Manual

Manual

Manual Uplink DPCH Bc

11 11

Manual Uplink DPCH Bd

15 15

RB Test Mode Setup:

Maximum Uplink Transmit Power Level

+21 dBm

+21 dBm

UE Loopback Type

Type 1

Type 1

HSUPA Parameters:

RB Test Mode E-RGCH Information State Off Off
E-DCH RLC SDU Size 2936 2936
E-DPCCH/DPCCH Power Offset (DeltaE-DPCCH) 6 6
Reference E-TFCI Power Offsets Definition 34121-01: v7.4.0 Table 5.2B.2 Definition 34121-01: v7.4.0 Table 5.2B.2
AG Mode Single Single
RB Setup AG 26: (119/15)^2 26: (119/15)^2
Absolute Grant Pattern - Value 1 N/A 20: (119/15)^2
Absolute Grant Pattern - Value 2 N/A 1: ZERO_GRANT
E-TFCI Rec Count 15 15



Top of pagetop of page     

+ +