E-TFCI Recording Information
Last updated: January 15, 2009
This section is only applicable to the lab application or feature-licensed test application.
The
Recorded E-TFCI Information
screen displays the
E-TFCI Recording State
,
Recorded E-TFCI Values
and
Number of E-TFCI Results Recorded
. These results are set to their default values if you select
Measurement Reset
, when the
Operating Mode
changes, when a new HSPA connection is established in
Active Cell Operating Mode
, or when
Channel Type
changes to/from
12.2k RMC + HSPA
while in
FDD Test Operating Mode
. The results are also set to their default values if you select
Clear UE Info
when the test set is not recording.
-
E-TFCI Recording State
This result indicates whether the test set is currently recording a sequence of E-TFCI values from the UE. Possible states include
Recording
and
Idle.
GPIB command:
CALL:STATus:ETFCi:RECord[:STATe]?
-
Recorded E-TFCI Values
This result returns the sequence of E-TFCI values recorded when the
Start Recording E-TFCI Values
action was initiated.
GPIB command:
CALL:STATus:ETFCi:RECord:ALL?
-
Number of E-TFCI Results Recorded
The number of E-TFCI results recorded is displayed at the bottom of the
Recorded E-TFCI Values
window (as shown circled above). When recording is active, this result is updated every 0.5 s. When recording is idle, this result indicates the number of E-TFCIs in the
Recorded E-TFCI Values
result.
GPIB command:
CALL:STATus:ETFCi:RECord:COUNt?
|