HSUPA PS Data Setup
Last updated: March 16, 2009
This section is only applicable to the lab application.
-
PS Data E-RGCH Information State
This setting determines whether the E-RGCH Information IE is signaled to the UE during the setup of a PDP context. If this IE is signaled, the UE will listen for up/down/hold commands on the E-RGCH. If it is not signaled, then the UE will not listen to an E-RGCH (and thus will determine its serving grant solely based upon the E-AGCH).
Note, this setting only affects whether the UE will listen to an E-RGCH. It does not affect whether an E-RGCH is transmitted by the test set. To transmit an E-RGCH from the test set, you must set
HSPA Cell 1 Connected E-RGCH Level
to on (it is on by default).
GPIB command:
CALL:HSUPa:SERVice:PSData:ERGChannel:INFormation[:STATe]
This setting can only be changed when the connection status is Idle.
-
PS Data E-DPDCH Max Channel Codes
This setting is used to control the value for E-DPDCH Max Channelisation Codes that is signaled to the UE during the setup of a PDP context that uses a 10 ms TTI on the E-DCH.
GPIB command:
CALL:HSUPa:SERVice:PSData:EDPDchannel:CCODes:MAX
This setting can only be changed when the connection status is Idle.
|