How Do I Set Up a Call and Make a Connection?
Last updated: January 15, 2009
Establishing a Connection
Set Cell Parameters
-
Press the
CALL SETUP
key.
-
Press the left
More
key to move to the
Call Control 2 of 5
menu.
-
Test Application: Press
Cell Parameters
(
F2
).
Lab Application: Press
Cell Info
(
F2
), then
Cell Parameters
(
F2
).
-
Set
BCCH Update Page
to
Auto
, if desired, so that the UE will be notified of any changes to the BCCH information transmitted by the test set after the call is established.
-
Set
ATT (IMSI Attach) Flag State
to
Set
, if required for your UE to register with the test set.
-
Set
Repeat Paging
to
On
, if desired, to help ensure your UE will respond to the test set's page.
-
Set any other cell parameters as needed.
-
Select
Close Menu
(
F6
).
Some cell parameters can only be set when
Operating Mode
(
F1
) is set to
Cell Off
.
Set Uplink Parameters
-
Press the
CALL SETUP
key.
-
Press the left
More
key to move to the
Call Control 2 of 5
menu.
-
Select
Uplink Parameters
(
F4
).
Set Call Parameters
-
Press the
CALL SETUP
key.
-
Set
Operating Mode
(
F1
) to
Cell Off
.
-
Select
Channel (UARFCN) Parms
(
F12
) and set the downlink and uplink channels to frequencies supported by your UE. Select
Return
(
F12
).
-
If required by your UE for successful call establishment:
-
Press the right
More
key to move to the
Call Parms 2 of 3
menu.
-
Set
RLC Reestablish
(
F9
) to
Off
.
-
Set
SRB Config
(
F12
) to
2.2k DCCH
.
-
Use the right
More
key to move between the three
Call Parms
menus and set other call parameters as needed.
-
Set
Operating Mode
(
F1
) to
Active Cell
.
Establish the Call
-
Connect the UE to the front panel
RF IN/OUT
port and power it on.
-
After a few seconds the UE should register with the test set. The test set then displays
UE Information
such as
IMSI
and
IMEI
on the
Call Setup
screen and the
MM Status
should change from
None
to
IMSI Attached
.
-
You can then establish the call in one of two ways:
-
Test set originated call -
-
Select
Paging Service
(
F9
) and set as needed.
-
If
Paging Service
is set to
RB Test Mode
, select
Channel Type
(
F8
) and set as needed.
-
Select
Originate Call
(
F3
).
-
For the lab application only, if
Paging Service
is set to
AMR Voice
, and
Calling Party Number Inclusion
is set to
Include
, the
Calling Party Number
is displayed on the UE's screen (see
How Do I Perform Calling Party Number Verification?
).
-
Answer the call if necessary, and verify that
Connected
is displayed in the
Active Cell
window.
-
UE initiated call -
-
Dial a number into the UE and press send.
-
Verify that
Connected
is displayed in the
Active Cell
window.
-
For the lab application only, the
Called Party Number
is displayed under
UE Information
.
Establishing an HSDPA Connection
This section is only applicable to the lab application or feature-licensed test application.
Before establishing an HSDPA connection, you may need to first set some of the parameters described in
Set Cell Parameters
,
Set Uplink Parameters
and
Set Call Parameters
.
Set HSDPA Parameters
-
Press the
CALL SETUP
key.
-
Select
HSDPA Parameters
(
HSPA Parameters
(
F10
),
F10
).
-
Select
HSDPA RB Test Mode Setup
(
F8
).
-
Set
FRC Type
to an H-Set supported by your UE or configure the user defined RB test mode channel as desired.
-
Set
CN Domain
as needed. Note, before you can establish a connection in the PS domain, the UE must have attached to the test set. To enable this, the
PS Domain Information
parameter must have been set to
Present
when the UE registered with the test set. Note that
PS Domain Information
is set to
Absent
by default in the Test Application (it is set to
Present
by default in the Lab Application).
-
Set
Uplink 64k DTCH for HSDPA Loopback State
as needed for your UE.
-
Set other
HSDPA RB Test Mode Setup
parameters as needed, then select
Close Menu
(
F6
).
-
Set
MAC-hs Parameters
(
F10
),
HSDPA Uplink Parameters
(
F11
) and
H-RNTI Parameters
(
F11
on
HSDPA Parms 2 of 2
) as needed, then select
Return
(
F12
).
Establish the HSDPA Connection
-
Connect the UE to the front panel
RF IN/OUT
port and power it on.
-
After a few seconds the UE should register with the test set. If
PS Domain Information
is set to
Absent
, the UE registers in the CS domain and
MM Status
changes from
None
to
IMSI Attached
. If
PS Domain Information
is set to
Present
, the UE should register in the CS domain and then also will register in the PS domain if it supports PS services (which causes
GMM State
to change from
None
to
Attached
).
Ensure that the
CN Domain
parameter is set to
CS Domain
if the UE did not attach to the GMM (see
Set HSDPA Parameters
).
-
Set
Paging Service
(
F9
) to
RB Test Mode
.
-
Set
Channel Type
(
F8
) to
12.2k RMC + HSDPA
.
-
Select
Originate Call
(
F3
).
-
Verify that
Connected
is displayed in the
Active Cell
window.
Establishing an HSPA Connection
This section is only applicable to the lab application or feature-licensed test application.
Before establishing an HSPA connection, you may need to first set some of the parameters described in
Set Cell Parameters
,
Set Uplink Parameters
and
Set Call Parameters
.
Set HSDPA Parameters
-
Press the
CALL SETUP
key.
-
Select
HSDPA Parameters
(
HSPA Parameters
(
F10
),
F10
).
-
Select
HSDPA RB Test Mode Setup
(
F8
).
-
Set
FRC Type
to an H-Set supported by your UE or configure the user defined RB test mode channel as desired.
-
Note that the
CN Domain
setting does not apply to HSPA connections (HSPA connections are always established in the PS Domain). However, before you can establish a connection in the PS domain, the UE must have attached to the test set. To enable this, the
PS Domain Information
parameter must have been set to
Present
when the UE registered with the test set. Note that
PS Domain Information
is set to
Absent
by default in the Test Application (it is set to
Present
by default in the Lab Application).
-
Set other
HSDPA RB Test Mode Setup
parameters as needed, then select
Close Menu
(
F6
).
-
Set
MAC-hs Parameters
(
F10
),
HSDPA Uplink Parameters
(
F11
) and
H-RNTI Parameters
(
F11
on
HSDPA Parms 2 of 2
) as needed, then select
Return
(
F12
).
Set HSUPA Parameters
-
Press the
CALL SETUP
key.
-
Select
HSUPA Parameters
(
HSPA Parameters
(
F10
),
F9
).
-
Select
HSUPA RB Test Mode Setup
(
F8
).
-
Set
RB Test Mode E-DPDCH Max Channel Codes
as needed (to achieve 2 Mbps in the uplink this must be set to
2SF2
).
-
Set
E-DCH RLC SDU Size
as needed (to achieve 2 Mbps in the uplink this must be set to at least
11744
).
-
Set other
HSUPA RB Test Mode Setup
parameters as needed, then select
Close Menu
(
F6
).
-
Set
Common HSUPA Parameters
(
F9
),
Serving Grant
parameters (
F11
) and
E-RNTI Parameters
(
F11
on
HSUPA Parms 2 of 2
) as needed, then select
Return
(
F12
).
Establish the HSPA Connection
-
Connect the UE to the front panel
RF IN/OUT
port and power it on.
-
After a few seconds the UE should register with the test set. If
PS Domain Information
is set to
Present
, the UE should register in the CS domain (
MM Status
) and then also will register in the PS domain if it supports PS services (which causes
GMM State
to change from
None
to
Attached
).
-
Set
Paging Service
(
F9
) to
RB Test Mode
.
-
Set
Channel Type
(
F8
) to
12.2k RMC + HSPA
.
-
Select
Originate Call
(
F3
).
-
Verify that
Connected
is displayed in the
Active Cell
window and observe the HSUPA and HSDPA counters.
|
|