CALL:AICHannel
Last updated: March 16, 2009
GPIB Command Conventions
CALL:AICHannel[:SLEVel]
|
Function
|
Sets/queries the acquisition indicator channel's initial power offset. This command sets the power offset level and turns on the power offset.
This setting cannot be changed while in active cell operating mode. Attempting to change this setting while in this mode results in the following error message: "Command Rejected. Change Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this value.
|
|
Setting
|
Range: -20.00 dB to 0 dB
Resolution: 0.01
|
|
Query
|
Range: -20.00 dB to 0 dB
Resolution: 0.01
|
|
*RST Setting
|
-9.9 dB |
|
Requirements
|
Test Application Revision: A.02 and above.
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:AICHannel -13DB" !Sets the acquisition indicator channel's power offset to -13 dB.
|
CALL:AICHannel:CCODe
|
Function
|
THIS COMMAND IS OBSOLETE. Please use
CALL:AICHannel:CCODe:CODE
.
Sets/queries the acquisition indicator channel's channelization code.
|
|
Setting
|
Range: CODE3|CODE6|CODE7|CODE8|CODE9|CODE10|CODE11
|
|
Query
|
Range: CODE3|CODE6|CODE7|CODE8|CODE9|CODE10|CODE11
|
|
*RST Setting
|
CODE10 |
|
Requirements
|
Test Application Revision: A.02 and above.
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:AICHannel:CCODe CODE6"
|
CALL:AICHannel:CCODe:CODE
|
Function
|
Sets/queries the acquisition indicator channel's channelization code. Codes 0 and 1 are reserved for the CPICH and SCH/PCCPCH respectively.
This setting cannot be changed while in active cell operating mode. Attempting to change this setting while in this mode results in the following error message: "Command Rejected While in Active Cell Mode." Use the cell off operating mode when changing this value.
|
|
Setting
|
Range: 2 to 255
Resolution: 1
|
|
Query
|
Range: 2 to 255
Resolution: 1
|
|
*RST Setting
|
10 |
|
Requirements
|
Lab Application Revision: F.00 and above
Test Application Revision: A.14 and above
|
|
Programming Example
OUTPUT 714;"CALL:AICHannel:CCODe:CODE 10"
|
CALL:AICHannel:LEVel
|
Function
|
Sets/queries the acquisition indicator channel's initial power offset.
This setting cannot be changed while in active cell operating mode. Attempting to change this setting while in this mode results in the following error message: "Command Rejected. Change Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this value.
|
|
Setting
|
Range: -20.00 dB to 0 dB
Resolution: 0.01
|
|
Query
|
Range: -20.00 dB to 0 dB
Resolution: 0.01
|
|
*RST Setting
|
-9.9 dB |
|
Requirements
|
Test Application Revision: A.02 and above.
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:AICHannel:LEVel -5"
|
CALL:AICHannel:STATe
|
Function
|
Sets/queries the acquisition indicator channel's state.
This setting cannot be changed while in active cell operating mode. Attempting to change this setting while in this mode results in the following error message: "Command Rejected. Change Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this value.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test Application Revision: A.02 and above.
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:AICHannel:STATe ON"
|
CALL:AICHannel:TRANsmission:TIMing
|
Function
|
Sets/queries
AICH Transmission Timing
.
This setting cannot be changed while in active cell operating mode. Attempting to change this setting while in this mode results in the following error message: "Command Rejected. Change Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this value.
|
|
Setting
|
Range: 0|1
|
|
Query
|
Range: 0|1
|
|
*RST Setting
|
0 |
|
Requirements
|
Lab Application Revision: E.00.34 and above
|
|
Programming Example
OUTPUT 714;"CALL:AICHannel:TRANsmission:TIMing 0"
|
|