Agilent Technologies Home Page 8960 Series 10 Wireless Communications Test Set
- +
Home | Product Web Site | Contact Us
+
- -
+ -
8960 W-CDMA/HSPA Online User's Guide
E1963A, E6703E
Search this guide for     
search tips



Feedback
Did the information on this web page help answer your question or solve a problem?

Yes
No
Did not apply

Please provide additional comments about this page.
(Optional, 255 character max)


Email address (optional):

Privacy Notice: We will not sell or give away your email address to any third party.

 



CALL:BCCHannel

Last updated: May 26, 2009

GPIB Command Conventions

CALL[:CELL]:BCCHannel:CELLlist

Function

Sets/queries the Cell Info List setting.

This parameter can only be set when call status is Idle . Changing this setting results in the execution of the Broadcast Channel (BCCH) Update Procedure (SIB Contents) if BCCH Update Page is set to Auto .

Setting

Range: PRESent|ABSent

Query

Range: PRES|ABS

*RST Setting

PRES
Requirements

Test Application Revision: A.03 and above.

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:CELLlist PRESent"
! Selects BCCH Cell Info List to preset on the BCCH.

CALL[:CELL]:BCCHannel:FBINdicator:STATe

Function

Sets/queries the Frequency Band Indicator State setting.

This setting cannot be changed in active cell operating mode.

Setting

Range: 1|ON|0|OFF

Query

1|0

*RST Setting

1 (on)
Requirements

Test Application Revision: A.08 and above.

Lab Application Revision: C.03 and above.

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:FBINdicator:STATe OFF"
! Turns Frequency Band Indicator State off.

CALL[:CELL]:BCCHannel:FMOCcasion:CLCoeff

Function

Sets/queries the BCCH SIB11 FACH measurement occasion cycle length coefficient.

This setting is used to calculate the measurement occasion cycle length.

Setting

Range: 1 to 12

Resolution: 1

Query

Range: same as setting

*RST Setting

3

Requirements

Lab Application Revision: F.00.19 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:FMOCcasion:CLCoeff 3"
! Sets the BCCH SIB11 FACH measurement occasion cycle length coefficient to 3.

CALL[:CELL]:BCCHannel:FMOCcasion:CLCoeff:CONTrol

Function

Sets/queries the BCCH SIB11 FACH measurement occasion cycle length coefficient control setting.

This setting determines whether the "FACH measurement occasion cycle length coefficient" parameter should be present in "FACH measurement occasion info".

Setting

Range: PRESent|ABSent

Query

Range: PRES|ABS

*RST Setting

PRESent
Requirements Lab Application Revision: F.00.19 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:FMOCcasion:CLCoeff:CONTrol PRESent"! 

CALL[:CELL]:BCCHannel:FMOCcasion:CONTrol

Function

Sets/queries the BCCH SIB11 FACH measurement occasion info Present setting.

This setting determines whether the SIB11 includes the IE of "FACH measurement occasion info".

Setting

Range: PRESent|ABSent

Query

Range: PRES|ABS

*RST Setting

ABSent
Requirements Lab Application Revision: F.00.19 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:FMOCcasion:CONTrol ABSent"

CALL[:CELL]:BCCHannel:FMOCcasion:FDDIndicator

Function

Sets/queries the BCCH SIB 11 Inter-frequency FDD measurement indicator:

  • When set to 1, the UE performs measurements and evaluate cell reselection criteria on inter-frequency FDD cells listed in SIB11 in CELL_FACH state.
  • When set to 0, the UE should neither perform measurements nor evaluate cell re-selection criteria on inter-frequency FDD cells in CELL_FACH state.

Setting

Range: 1|0

Query

1|0

*RST Setting

1

Requirements

Lab Application Revision: F.00.19 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:FMOCcasion:FDDIndicator 1"

CALL[:CELL]:BCCHannel:FMOCcasion:RATIndicator:CONTrol

Function

Sets/queries the BCCH SIB 11 Inter-RAT measurement indicators control setting.

This setting determines whether "Inter-RAT measurement indicators" and the associated "RAT type" should be present in "FACH measurement occasion info". Currently, the "Inter-RAT measurement indicators" is fixed at 1 and the "RAT type" is fixed to GSM. If this setting is set to Present, the UE performs measurements and evaluates cell reselection criteria on GSM cells that are listed in SIB11 in CELL_FACH state.

Setting

Range: PRESent|ABSent

Query

Range: PRES|ABS

*RST Setting

PRESent
Requirements Lab Application Revision: F.00.19 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:FMOCcasion:RATIndicator:CONTrol PRESent"
! Sets the BCCH SIB 11 Inter-RAT measurement indicators control setting to Present.

CALL[:CELL]:BCCHannel:GSMSystem:BAND

Function

Sets/queries the band for each of the 8 GSM neighbor cells (see GSM Cells ).

This parameter can only be set when call status is Idle . Changing this setting results in the execution of the Broadcast Channel (BCCH) Update Procedure (SIB Contents) if BCCH Update Page is set to Auto .

Setting

Range: DCS1800|PCS1900,DCS1800|PCS1900,DCS1800|PCS1900,
DCS1800|PCS1900,DCS1800|PCS1900,DCS1800|PCS1900,
DCS1800|PCS1900,DCS1800|PCS1900

The command must be issued with a comma-separated list of 8 values. Each value in the list defines the band for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell list transmitted by the test set is controlled by the CALL[:CELL]:BCCHannel:GSMSystem:STATe setting.

Query

Range: same as setting

*RST Setting

DCS1800,DCS1800,DCS1800,DCS1800,DCS1800,DCS1800,DCS1800,DCS1800,

Requirements

Test Application Revision: A.05 and above.

Lab Application Revision: B.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:GSMSystem:BAND PCS1900,PCS1900,PCS1900,PCS1900,PCS1900,
PCS1900,PCS1900,PCS1900"
! Sets the band for each of the 8 GSM neighbor cells to PCS1900.

CALL[:CELL]:BCCHannel:GSMSystem:BCC

Function

Sets/queries the BCC for each of the 8 GSM neighbor cells (see GSM Cells ).

This parameter can only be set when call status is Idle . Changing this setting results in the execution of the Broadcast Channel (BCCH) Update Procedure (SIB Contents) if BCCH Update Page is set to Auto .

Setting

Range: 0 to 7

Resolution: 1

The command must be issued with a comma-separated list of 8 values. Each value in the list defines the BCC for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell list transmitted by the test set is controlled by the CALL[:CELL]:BCCHannel:GSMSystem:STATe setting.

Query

Range: same as setting

*RST Setting

5,0,1,2,3,4,6,7

Requirements

Test Application Revision: A.05 and above.

Lab Application Revision: B.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:GSMSystem:BCC 4,1,3,6,0,7,2,5"
! Sets the BCC for the first GSM neighbor cell to 4,
! sets the BCC for the second GSm neighbor cell to 1, etc.

CALL[:CELL]:BCCHannel:GSMSystem:BCHannel

Function

Sets/queries the BCH ARFCN for each of the 8 GSM neighbor cells (see GSM Cells ).

This parameter can only be set when call status is Idle . Changing this setting results in the execution of the Broadcast Channel (BCCH) Update Procedure (SIB Contents) if BCCH Update Page is set to Auto .

Setting

Range: 0 to 1023

Resolution: 1

The command must be issued with a comma-separated list of 8 values. Each value in the list defines the BCH ARFCN for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell list transmitted by the test set is controlled by the CALL[:CELL]:BCCHannel:GSMSystem:STATe setting.

Query

Range: same as setting

*RST Setting

20,30,40,50,60,70,80,90

Requirements

Test Application Revision: A.05 and above.

Lab Application Revision: B.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:GSMSystem:BCHannel 22,32,42,52,62,72,82,92"
! Sets the BCH ARFCN for the first GSM neighbor cell to 22,
! sets the BCC for the second GSm neighbor cell to 32, etc.

CALL[:CELL]:BCCHannel:GSMSystem:NCC

Function

Sets/queries the NCC for each of the 8 GSM neighbor cells (see GSM Cells ).

This parameter can only be set when call status is Idle . Changing this setting results in the execution of the Broadcast Channel (BCCH) Update Procedure (SIB Contents) if BCCH Update Page is set to Auto .

Setting

Range: 0 to 7

Resolution: 1

The command must be issued with a comma-separated list of 8 values. Each value in the list defines the NCC for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell list transmitted by the test set is controlled by the CALL[:CELL]:BCCHannel:GSMSystem:STATe setting.

Query

Range: same as setting

*RST Setting

1, 0, 2, 3, 4, 5, 6, 7

Requirements

Test Application Revision: A.05 and above.

Lab Application Revision: B.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:GSMSystem:NCC 7,1,6,3,0,4,5,2"
! Sets the NCC for the first GSM neighbor cell to 7,
! sets the NCC for the second GSm neighbor cell to 1, etc.

CALL[:CELL]:BCCHannel:GSMSystem:CRESelection:RLMinimum

Function

Sets/queries GSM <num> Cell Cell Reselection Min Rx Level for each of the 8 GSM neighbor cells.

This parameter can only be set when call status is Idle . Changing this setting results in the execution of the Broadcast Channel (BCCH) Update Procedure (SIB Contents) if BCCH Update Page is set to Auto .

Setting

Range: -115 to -25 dBm

Resolution: 1 dB

The command must be issued with a comma-separated list of 8 values. Each value in the list defines the Cell Reselection Min Rx Level for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell list transmitted by the test set is controlled by the CALL[:CELL]:BCCHannel:GSMSystem:STATe setting.

Query

Range: same as setting

*RST Setting

-104,-104,-104,-104,-104,-104,-104,-104 (dBm)

Requirements

Lab Application Revision: D.00.04 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:GSMSystem:CRESelection:RLMinimum 
-100,-100,-100,-100,-100,-100,-100,-100"
! Sets Cell Reselection Min Rx Level for the first GSM neighbor cell to -100 dBm,
! sets Cell Reselection Min Rx Level for the second GSM neighbor cell to -100 dBm, etc.

CALL[:CELL]:BCCHannel:GSMSystem:STATe

Function

Sets/queries whether each of the 8 GSM neighbor cells is included in the cell info list transmitted by the test set (see GSM Cells ).

This parameter can only be set when call status is Idle . Changing this setting results in the execution of the Broadcast Channel (BCCH) Update Procedure (SIB Contents) if BCCH Update Page is set to Auto .

Setting

Range: 1|ON|0|OFF

The command must be issued with a comma-separated list of 8 valid settings.

Query

Range: 1|0

*RST Setting

1,0,0,0,0,0,0,0

Requirements

Test Application Revision: A.05 and above.

Lab Application Revision: B.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:GSMSystem:STATe 1,1,1,1,1,1,1,1"
! Includes all 8 GSM neighbor cells in the cell info list.

CALL[:CELL]:BCCHannel:INTERFREQ:DOWNlink:CHANnel

Function

THIS COMMAND IS OBSOLETE. Please use the CALL[:CELL]:BCCHannel:ITRFrequency:DOWNlink:CHANnel command.

Sets/queries the downlink channel number (DL UARFCN) of the Inter-frequency cell info list which is included in the System Information Block (SIB) 11 on the BCCH. The Inter-frequency cell info list contains only one cell.

This setting is available only when the BCCH SIB 11 Cell Info List is set to "Present" (see CALL[:CELL]:BCCHannel:CELLlist ).

If this setting is changed while the Operating Mode is "Active Cell.", the test set will perform the BCCH Update procedure.

Setting

Range:

  • 412 - 687
  • 4320 - 4495
  • 4600 - 4825
  • 9000 - 9425
  • 9625 - 9975
  • 10,525 - 10,875

Query

Range: Same as settings

*RST Setting

10730

Requirements

Test Application Revision: A.03 and above.

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:INTERFREQ:DOWNlink:CHANnel 10735"
! Sets the BCCH Inter-frequency Cell DL UARFCN to 10735.

CALL[:CELL]:BCCHannel:INTERFREQ:SCODe

Function

THIS COMMAND IS OBSOLETE. Please use the CALL[:CELL]:BCCHannel:ITRFrequency:SCODe command.

Sets/queries the primary scrambling code of the Inter-frequency cell info list which is included in the System Information Block (SIB) 11 on the BCCH. The Inter-frequency cell info list contains only one cell.

This setting is available only when the BCCH SIB 11 Cell Info List is set to "Present" (see CALL[:CELL]:BCCHannel:CELLlist ).

If this setting is changed while the Operating Mode is "Active Cell.", the test set will perform the BCCH Update procedure.

Setting

Range: 0 to 511

Resolution: 1

Query

Range: same as settings

*RST Setting

63

Requirements

Test Application Revision: A.03 and above.

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:INTERFREQ:SCODe 63"
! Sets the BCCH Inter-frequency Cell Scrambling Code to 63.

CALL[:CELL]:BCCHannel:INTRAFREQ:CELL2:SCODe

Function

THIS COMMAND IS OBSOLETE. Please use the CALL[:CELL]:BCCHannel:ITAFrequency:SCODe command.

Sets/queries the primary scrambling code of the 2nd cell in the Intra-frequency cell info list which is included in the System Information Block (SIB) 11 on the BCCH. This setting is available only when the BCCH SIB 11 Cell Info List is set to "Present" (see CALL[:CELL]:BCCHannel:CELLlist ).

The Intra-frequency cell info list contains three cells. As required by the W-CDMA specifications, Cell 1 in this list is always the serving cell so the cell information is automatically set to match the test set's cell.

If this setting is changed while the Operating Mode is "Active Cell.", the test set will perform the BCCH Update procedure.

Setting

Range: 0 to511

Resolution: 1

Query

Range: same as settings

*RST Setting

127

Requirements

Test Application Revision: A.03 and above.

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:INTRAFREQ:CELL2:SCODe 130"
! Sets the BCCH Intra-frequency Cell 2 Scrambling Code to 130.

CALL[:CELL]:BCCHannel:INTRAFREQ:CELL3:SCODe

Function

THIS COMMAND IS OBSOLETE. Please use the CALL[:CELL]:BCCHannel:ITAFrequency:SCODe command.

Sets/queries the primary scrambling code of the 3rd cell in the Intra-frequency cell info list which is included in the System Information Block (SIB) 11 on the BCCH. This setting is available only when the BCCH SIB 11 Cell Info List is set to "Present" (see CALL[:CELL]:BCCHannel:CELLlist ).

The Intra-frequency cell info list contains three cells. As required by the W-CDMA specifications, Cell 1 in this list is always the serving cell so the cell information is automatically set to match the test set's cell.

If this setting is changed while the Operating Mode is "Active Cell.", the test set will perform the BCCH Update procedure.

Setting

Range: 0 - 511

Resolution: 1

Query

Range: same as settings

*RST Setting

511

Requirements

Test Application Revision: A.03 and above.

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:INTRAFREQ:CELL3:SCODe 500"
! Sets the BCCH Intra-frequency Cell 3 Scrambling Code to 500.

CALL[:CELL]:BCCHannel:ITAFrequency:CRESelection:OFFSet[1]

Function

Sets/queries Intra-freq <num> Cell Cell Reselection Offset1 for each of the 8 intra-frequency neighbor cells.

This parameter can only be set when call status is Idle . Changing this setting results in the execution of the Broadcast Channel (BCCH) Update Procedure (SIB Contents) if BCCH Update Page is set to Auto .

Setting

Range: -50 to 50 dB

Resolution: 1 dB

The command must be issued with a comma-separated list of 8 values. Each value in the list defines the Cell Reselection Offset1 for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell list transmitted by the test set is controlled by the CALL[:CELL]:BCCHannel:ITAFrequency:STATe setting.

Query

Range: same as setting

*RST Setting

0,0,0,0,0,0,0,0 (dB)

Requirements

Lab Application Revision: D.00.04 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:ITAFrequency:CRESelection:OFFSet -20,-20,-20,-20,-20,-20,-20,-20"
! Sets Cell Reselection Offset1 for the first intra-frequency neighbor cell to -20 dB,
! sets Cell Reselection Offset1 for the second intra-frequency neighbor cell to -20 dB, etc.

CALL[:CELL]:BCCHannel:ITAFrequency:CRESelection:OFFSet2

Function

Sets/queries Intra-freq <num> Cell Cell Reselection Offset2 for each of the 8 intra-frequency neighbor cells.

This parameter can only be set when call status is Idle . Changing this setting results in the execution of the Broadcast Channel (BCCH) Update Procedure (SIB Contents) if BCCH Update Page is set to Auto .

Setting

Range: -50 to 50 dB

Resolution: 1 dB

The command must be issued with a comma-separated list of 8 values. Each value in the list defines the Cell Reselection Offset2 for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell list transmitted by the test set is controlled by the CALL[:CELL]:BCCHannel:ITAFrequency:STATe setting.

Query

Range: same as setting

*RST Setting

0,0,0,0,0,0,0,0 (dB)

Requirements

Lab Application Revision: D.00.04 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:ITAFrequency:CRESelection:OFFSet2 -20,-20,-20,-20,-20,-20,-20,-20"
! Sets Cell Reselection Offset2 for the first intra-frequency neighbor cell to -20 dB,
! sets Cell Reselection Offset2 for the second intra-frequency neighbor cell to -20 dB, etc.

CALL[:CELL]:BCCHannel:ITAFrequency:SCODe

Function

Sets/queries the primary scrambling code for each of the 8 intra frequency neighbor cells (see Intra-frequency Cells ).

This parameter can only be set when call status is Idle . Changing this setting results in the execution of the Broadcast Channel (BCCH) Update Procedure (SIB Contents) if BCCH Update Page is set to Auto .

Setting

Range: 0 to 511

Resolution: 1

The command must be issued with a comma-separated list of 8 values. Each value in the list defines the primary scrambling code for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell info list transmitted by the test set is controlled by the CALL[:CELL]:BCCHannel:ITAFrequency:STATe setting.

Query

Range: same as setting

*RST Setting

0,127,191,255,319,383,447,511

Requirements

Test Application Revision: A.05 and above.

Lab Application Revision: B.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:ITAFrequency:SCODe 0,127,192,255,320,384,448,511"
! Sets the scrambling code for the first intra frequency neighbor
! cell to 0, sets the scrambling code for the second intra
! frequency neighbor cell to 127, etc.

CALL[:CELL]:BCCHannel:ITAFrequency:STATe

Function

Sets/queries whether each of the 8 intra frequency neighbor cells is included in the cell info list transmitted by the test set (see Intra-frequency Cells ).

Changing this setting results in the execution of the Broadcast Channel (BCCH) Update Procedure (SIB Contents) if BCCH Update Page is set to Auto .

Setting

Range: 1|ON|0|OFF

The command must be issued with a comma-separated list of 8 valid settings.

Query

Range: 1|0

*RST Setting

1,1,0,0,0,0,0,0

Requirements

Test Application Revision: A.05 and above.

Lab Application Revision: B.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:ITAFrequency:STATe 1,1,1,1,1,1,1,1"
! Includes all 8 intra frequency neighbor cells in the
! cell info list.

CALL[:CELL]:BCCHannel:ITRFrequency:CRESelection:OFFSet[1]

Function

Sets/queries Inter-freq <num> Cell Cell Reselection Offset1 for each of the 8 intra-frequency neighbor cells.

This parameter can only be set when call status is Idle . Changing this setting results in the execution of the Broadcast Channel (BCCH) Update Procedure (SIB Contents) if BCCH Update Page is set to Auto .

Setting

Range: -50 to 50 dB

Resolution: 1 dB

The command must be issued with a comma-separated list of 8 values. Each value in the list defines the Cell Reselection Offset1 for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell list transmitted by the test set is controlled by the CALL[:CELL]:BCCHannel:ITRFrequency:STATe setting.

Query

Range: same as setting

*RST Setting

0,0,0,0,0,0,0,0 (dB)

Requirements

Lab Application Revision: D.00.04 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:ITRFrequency:CRESelection:OFFSet -20,-20,-20,-20,-20,-20,-20,-20"
! Sets Cell Reselection Offset1 for the first inter-frequency neighbor cell to -20 dB,
! sets Cell Reselection Offset1 for the second inter-frequency neighbor cell to -20 dB, etc.

CALL[:CELL]:BCCHannel:ITRFrequency:CRESelection:OFFSet2

Function

Sets/queries Inter-freq <num> Cell Cell Reselection Offset2 for each of the 8 intra-frequency neighbor cells.

This parameter can only be set when call status is Idle . Changing this setting results in the execution of the Broadcast Channel (BCCH) Update Procedure (SIB Contents) if BCCH Update Page is set to Auto .

Setting

Range: -50 to 50 dB

Resolution: 1 dB

The command must be issued with a comma-separated list of 8 values. Each value in the list defines the Cell Reselection Offset2 for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell list transmitted by the test set is controlled by the CALL[:CELL]:BCCHannel:ITRFrequency:STATe setting.

Query

Range: same as setting

*RST Setting

0,0,0,0,0,0,0,0 (dB)

Requirements

Lab Application Revision: D.00.04 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:ITRFrequency:CRESelection:OFFSet2 -20,-20,-20,-20,-20,-20,-20,-20"
! Sets Cell Reselection Offset2 for the first inter-frequency neighbor cell to -20 dB,
! sets Cell Reselection Offset2 for the second inter-frequency neighbor cell to -20 dB, etc.

CALL[:CELL]:BCCHannel:ITRFrequency:DOWNlink:CHANnel

Function

Sets/queries the UARFCN for each of the 8 inter frequency neighbor cells (see Inter-frequency Cells ).

This parameter can only be set when call status is Idle . Changing this setting results in the execution of the Broadcast Channel (BCCH) Update Procedure (SIB Contents) if BCCH Update Page is set to Auto .

Setting

Range:

  • 412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687
  • 1007, 1012, 1032, 1037, 1062, 1087
  • 1162 - 1513, resolution = 1
  • 1537 - 1738, resolution = 1
  • 1887, 1912, 1937, 1962, 1987, 2012, 2037, 2062, 2087
  • 2237 - 2563, resolution = 1
  • 2587, 2612, 2637, 2662, 2687, 2712, 2737, 2762, 2787, 2812, 2837, 2862, 2887, 2912
  • 2937 - 3088, resolution = 1
  • 3112 to 3388, resolution = 1
  • 3412, 3437, 3462, 3487, 3512, 3537, 3562, 3587, 3612, 3637, 3662, 3687
  • 3837 - 3903, resolution = 1
  • 3927, 3932, 3957, 3962, 3987, 3992
  • 4017 - 4043, resolution = 1
  • 4067, 4092
  • 4117 - 4143, resolution = 1
  • 4167, 4192
  • 4357 - 4458, resolution = 1
  • 9237 - 9387, resolution = 1
  • 9662 - 9938, resolution = 1
  • 10562 - 10838, resolution = 1

The command must be issued with a comma-separated list of 8 values. Each value in the list defines the UARFCN for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell info list transmitted by the test set is controlled by the CALL[:CELL]:BCCHannel:ITRFrequency:STATe setting.

Query

Range: same as setting

*RST Setting

10730,10730,10730,10730,10730,10730,10730,10730

Requirements

Test Application Revision: A.05 and above.

Lab Application Revision: B.01 and above

Test Application Revision: A.05.28 and above, added 1037 - 1062.

Lab Application Revision: B.01 and above

Lab Application Revision: B.01.29 and above, added 1037 - 1062.

Test Application Revision A.09 and Lab Application Revision C.04 and D.00, changed channel ranges to match 3GPP TS 25.101 v7.2.0 (previously, channels supported were: 412-687, 1037-1062, 4320-4495, 4600-4825, 9000-9425, 9625-9975, and 10,525-10,875, resolution = 1).

Test Application Revision A.11 and Lab Application Revisions D.02 and E.00, added 3112 to 3388, 3412, 3437, 3462, 3487, 3512, 3537, 3562, 3587, 3612, 3637, 3662, 3687

Test Application Revision A.14 and Lab Application Revision F.00, added 3837 - 3903, 3927, 3932, 3957, 3962, 3987, 3992, 4017 - 4043, 4067, 4092, 4117 - 4143, 4167, 4192

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:ITRFrequency:DOWNlink:CHANnel 10730,10730,10730,10730,
10730,10730,10730,10730"
! Sets the UARFCN for each of the 8 inter frequency neighbor
! cells to 10730.

CALL[:CELL]:BCCHannel:ITRFrequency:SCODe

Function

Sets/queries the primary scrambling code for each of the 8 inter frequency neighbor cells (see Inter-frequency Cells ).

This parameter can only be set when call status is Idle . Changing this setting results in the execution of the Broadcast Channel (BCCH) Update Procedure (SIB Contents) if BCCH Update Page is set to Auto .

Setting

Range: 0 to 511

Resolution: 1

The command must be issued with a comma-separated list of 8 values. Each value in the list defines the primary scrambling code for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell info list transmitted by the test set is controlled by the CALL[:CELL]:BCCHannel:ITRFrequency:STATe setting.

Query

Range: same as setting

*RST Setting

0,127,191,255,319,383,447,511

Requirements

Test Application Revision: A.05 and above.

Lab Application Revision: B.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:ITRFrequency:SCODe 0,127,192,255,320,384,448,511"
! Sets the scrambling code for the first inter frequency neighbor
! cell to 0, sets the scrambling code for the second inter
! frequency neighbor cell to 127, etc.

CALL[:CELL]:BCCHannel:ITRFrequency:STATe

Function

Sets/queries whether each of the 8 inter frequency neighbor cells is included in the cell info list transmitted by the test set (see Inter-frequency Cells ).

This parameter can only be set when call status is Idle . Changing this setting results in the execution of the Broadcast Channel (BCCH) Update Procedure (SIB Contents) if BCCH Update Page is set to Auto .

Setting

Range: 1|ON|0|OFF

The command must be issued with a comma-separated list of 8 valid settings.

Query

Range: 1|0

*RST Setting

1,0,0,0,0,0,0,0

Requirements

Test Application Revision: A.05 and above.

Lab Application Revision: B.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:ITRFrequency:STATe 1,1,1,1,1,1,1,1"
! Includes all 8 inter frequency neighbor cells in the
! cell info list.

CALL[:CELL]:BCCHannel:N300

Function

Sets/queries the N300 RRC Conn Req Max Retransmits .

This setting can only be changed when call status is Idle . If BCCH Update Page is set to Auto and you change this setting while your UE is camped to the test set, the test set performs a Broadcast Channel (BCCH) Update Procedure (SIB Contents) . If BCCH Update Page is set to Inhibit (the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see BCCH Update Page for more details).

Setting

Range: 0 to 7

Resolution: 1

Query

Same as setting

*RST Setting

0

Requirements

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:N300 0"
! Sets the N300 Constant to 0.

CALL[:CELL]:BCCHannel:N312[:IDLE]

Function

Sets/queries the N312 Link Establishment In-Sync Count (Idle) .

This setting can only be changed when call status is Idle . If BCCH Update Page is set to Auto and you change this setting while your UE is camped to the test set, the test set performs a Broadcast Channel (BCCH) Update Procedure (SIB Contents) . If BCCH Update Page is set to Inhibit (the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see BCCH Update Page for more details).

Setting

Range: 1, 2, 4, 10, 20, 50, 100, 200, 400, 600, 800, 1000

Query

Same as setting

*RST Setting

50

Requirements

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:N312 50"
! Sets the N312 Constant to 50.

CALL[:CELL]:BCCHannel:N313

Function

Sets/queries the T313 Out-Of-Sync Reception Timer .

This setting can only be changed when call status is Idle . If BCCH Update Page is set to Auto and you change this setting while your UE is camped to the test set, the test set performs a Broadcast Channel (BCCH) Update Procedure (SIB Contents) . If BCCH Update Page is set to Inhibit (the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see BCCH Update Page for more details).

Setting

Range: S1|S2|S4|S10|S20|S50|S100|S200

Query

Same as setting

*RST Setting

S2

Requirements

Test Application Revision: A.06 and above

Lab Application Revision: C.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:N313 S200"
! Sets the N313 UE Out-Of-Sync Counter to S200

CALL[:CELL]:BCCHannel:N315

Function

Sets/queries the N315 Successive In-Sync Reception Counter .

This setting can only be changed when call status is Idle . If BCCH Update Page is set to Auto and you change this setting while your UE is camped to the test set, the test set performs a Broadcast Channel (BCCH) Update Procedure (SIB Contents) . If BCCH Update Page is set to Inhibit (the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see BCCH Update Page for more details).

Setting

Range: S1|S2|S4|S10|S20|S50|S100|S200|S400|S600|S800|S1000

Query

Same as setting

*RST Setting

S50

Requirements

Test Application Revision: A.06 and above

Lab Application Revision: C.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:N315 S1"
! Sets N315 UE In-Sync Counter to S1.

CALL[:CELL]:BCCHannel:SERSearch[:SVALue]

Function

The setting form of this command performs two functions: (1) sets the Sintersearch value (see CALL[:CELL]:BCCHannel:SERSearch:VALue ) and (2) sets the Sintersearch state to on (see CALL[:CELL]:BCCHannel:SERSearch:STATe ).

The query form of this command returns the Sintersearch value.

This setting can only be changed when call status is Idle . If BCCH Update Page is set to Auto and you change this setting while your UE is camped to the test set, the test set performs a Broadcast Channel (BCCH) Update Procedure (SIB Contents) . If BCCH Update Page is set to Inhibit (the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see BCCH Update Page for more details).

Setting

Range: -32 dB to 20 dB

Resolution: 2 dB

Sintersearch can be set to any even number value between -32 dB and +20 dB, but any negative value will be interpreted by the UE as 0 dB.

Query

Same as setting

*RST Setting

Value = 0 dB

State = On

Requirements

Lab Application Revision: C.02 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:SERSearch 4"
! Sets Sintersearch state to on and sets Sintersearch value to 4 dB.

CALL[:CELL]:BCCHannel:SERSearch:STATe

Function

Sets/queries the Sintersearch state. The Sintersearch state can also be set using the CALL[:CELL]:BCCHannel:SERSearch[:SVALue] command.

This parameter can only be set when call status is Idle . Changing this setting results in the execution of the Broadcast Channel (BCCH) Update Procedure (SIB Contents) if BCCH Update Page is set to Auto .

Setting

Range: 1|ON|0|OFF

Query

1|0

*RST Setting

1 (on)

Requirements

Lab Application Revision: C.02 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:SERSearch:STATe OFF"
! Turns Sintersearch state off.

CALL[:CELL]:BCCHannel:SERSearch:VALue

Function

Sets/queries the Sintersearch value. The Sintersearch value can also be set using the CALL[:CELL]:BCCHannel:SERSearch[:SVALue] command.

This parameter can only be set when call status is Idle . Changing this setting results in the execution of the Broadcast Channel (BCCH) Update Procedure (SIB Contents) if BCCH Update Page is set to Auto .

Setting

Range: -32 dB to 20 dB

Resolution: 2 dB

Sintersearch can be set to any even number value between -32 dB and +20 dB, but any negative value will be interpreted by the UE as 0 dB.

Query

Same as setting

*RST Setting

0 dB

Requirements

Lab Application Revision: C.02 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:SERSearch:VALue 4 DB"
! Sets the Sintersearch value to 4 dB.

CALL[:CELL]:BCCHannel:SIB5:BIS

Function

Sets/queries Transmit SIB5bis .

This setting can only be changed when call status is Idle . If BCCH Update Page is set to Auto and you change this setting while your UE is camped to the test set, the test set performs a Broadcast Channel (BCCH) Update Procedure (SIB Contents) . If BCCH Update Page is set to Inhibit (the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see BCCH Update Page for more details).

Setting

Range:

  • ALL - All Bands
  • BAND10 - Band X
  • BAND4 - Band IV
  • BAND9 - Band IX
  • BAND49 - Bands IV & IX
  • NONE - No Bands
  • SBANds - Standard Bands

Query

Same as setting

*RST Setting

SBAN

Requirements

Test Application Revision: A.01.01 and above

Lab Application Revision: D.00.04 and above

Test Application Revision A.11, Lab Application Revisions D.02 and E.00, added BAND10 and SBANds, changed default from BAND49 to SBANds.

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:SIB5:BIS SBANds"
! Sets Transmit SIB5bis to Standard Bands.

CALL[:CELL]:BCCHannel:SIB15:GPSystem:TIME:OFFset:TTOWeek

Function

Sets/queries the GPS Transmission TOW Offset.

This defines a static offset in seconds that is applied to the transmissionTOW IE whenever it is updated in the SIB15.x messages.The purpose of this parameter is to allow you to introduce deliberate errors into the accuracy of GPS time signaled by this IE.

Setting

Range: -30 to +30

Resolution: 1

Query

Same as setting

*RST Setting

0

Requirements

Lab Application Revision: E.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:SIB15:GPSystem:TIME:OFFset:TTOWeek 0"
! Sets the GPS Transmission TOW Offset to 0.

CALL[:CELL]:BCCHannel:SIB15:GPSystem:TIME:OFFSet:TOWeek:MSECond

Function

Sets/queries the GPS TOW 1ms Offset.

This defines a static offset in seconds that is applied to gps-tow-1msec IE whenever it is updated in the SIB15.X messages. The purpose of this parameter is to allow you to introduce deliberate errors into the accuracy of GPS time signaled by this IE.

Setting

Range: -5.0 to +5.0 seconds

Resolution: 0.1 seconds

Query

Same as setting

*RST Setting

0 seconds

Requirements

Lab Application Revision: E.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:SIB15:GPSystem:TIME:OFFSet:TOWeek:MSECond 0"
! Sets the GPS TOW 1ms Offset to 0 seconds.

CALL[:CELL]:BCCHannel:SIB15:GPSystem:TIME:OFFSet:UTRan

Function

Sets/queries the UTRAN GPS TimingOfCell Offset.

This defines a static offset in micro-seconds that will be applied to the utran-GPSTimingOfCell IE (rounded to nearest chip). The purpose of this parameter is to allow you to introduce deliberate errors into the accuracy of GPS time signaled by this IE.

Setting

Range: -100 to +100 microseconds

Resoultion 1 microseconds

Query

Same as setting

*RST Setting

0 microseconds

Requirements

Lab Application Revision: E.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:SIB15:GPSystem:TIME:OFFSet:UTRan 0"
! Sets the UTRAN GPS TimingOfCell Offset to 0 microseconds.

CALL[:CELL]:BCCHannel:SIB15:GPSystem:TIME:REFerence:UPDate[:STATe]

Function

Sets/queries the GPS Reference Time Update State.

This controls whether the test set updates the utran-GPSReferenceTime IE in SIB15 when the GPS Time Sync State is On. If this parameter is On, then the test set will assume that the encoded SIB15 you supply contains the optional utran-GPSReferenceTime IE.

This setting can only be changed while Section the SIB15.x Transmission State is Off. If you attempt to change this parameter while the SIB15.x Transmission State is On the application will reject the setting with the error "+XXX FDD Call processing error; This setting cannot be changed while SIB15.x messages are being transmitted."

Setting

Range: 1|ON|0|OFF

Query

1|0

*RST Setting

0 (off)

Requirements

Lab Application Revision: E.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:SIB15:GPSystem:TIME:REFerence:UPDate OFF"
! Sets the GPS Reference Time Update State to Off.

CALL[:CELL]:BCCHannel:SIB15:GPSystem:TIME:REFerence:SFN

Function

Sets/queries the GPS Reference Time SFN.

This defines the SFN that is assumed when the test set updates the utran-GPSTimingOfCell parameters in the utran-GPSReferenceTime IE in SIB15. The test set does not set the SFN field in the utran-GPSReferenceTime IE but instead assumes that you have already configured that field in the encoded SIB15 to match this setting.

This setting can only be changed while SIB15.x Transmission State is Off. If you attempt to change this parameter while SIB15.x Transmission State is On, the application will reject the setting with the error "+XXX FDD Call processing error; This setting cannot be changed while SIB15.x messages are being transmitted."

Setting

Range: 0 to 4095

Resolution: 1

Query

Same as setting

*RST Setting

0

Requirements

Lab Application Revision: E.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:SIB15:GPSystem:TIME:REFerence:SFN 0"
! Sets the GPS Reference Time SFN to 0.

CALL[:CELL]:BCCHannel:SIB15:MESSage:S15

Function

Sets/queries the SIB15 Message. This defines the encoded SIB15 message that the test set sends out.

Setting <length of encoded message in bits> to zero deletes the stored message.

The Reference Time Offset parameter contains the bit offset of where the ue-positioning-GPS-ReferenceTime IE starts.

This setting can only be changed while SIB15.x Transmission State is Off. If you attempt to change this parameter while SIB15.x Transmission State is On the application will reject the setting with the error "+XXX FDD call processing error; This setting cannot be changed while SIB15.x messages are being transmitted."

If the length of the message in bits rounded up to the next round number of 4 bits does not equal the number of bits in the message itself then the setting will be rejected with the error "+XXX FDD call processing error; The length of the message and the length field do not match."

If the length of the message is greater than 800 bits then the setting will be rejected with the error "+XXX FDD call processing error; Message size exceeds maximum length for this message type."

Setting

Range: <length of encoded message in bits>, <Reference Time Offset in bits>, <"ascii string of hex digits defining">

Query

Same as setting

*RST Setting

0, 0, ""

Requirements

Lab Application Revision: E.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:SIB15:MESSage:S15 0, 0, """
! Sets the SIB15 message.

CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point1

Function

Sets/queries the SIB15.1 Message. This defines the encoded SIB15.1 message that the test set will send out.

Setting <length of encoded message in bits> to zero deletes the stored message.

This setting can only be changed while SIB15.x Transmission State is Off. If you attempt to change this parameter while SIB15.x Transmission State is On the application will reject the setting with the error "+XXX FDD call processing error; This setting cannot be changed while SIB15.x messages are being transmitted."

If the length of the message in bits rounded up to the next round number of 4 bits does not equal the number of bits in the message itself then the setting will be rejected with the error "+XXX FDD call processing error; The length of the message and the length field do not match."

If the length of the message is greater than 1200 bits then the setting will be rejected with the error "+XXX FDD call processing error; Message size exceeds maximum length for this message type."

Setting

Range: <length of encoded message in bits>, <"ascii string of hex digits defining SIB">

Query

Same as setting

*RST Setting

0, ""

Requirements

Lab Application Revision: E.01 and above

Programming Example

 
OUTPUT 714;"CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point2:MESSage1 0, """
! Sets the SIB15.1 Message to 0, "".

CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point2:MESSage1

Function

Sets/queries the First SIB15.2 Message.

This defines the first encoded SIB15.2 message that the test set will send out.

This setting can only be changed while SIB15.x Transmission State is Off. If you attempt to change this parameter while SIB15.x Transmission State is On the application will reject the setting with the error "+XXX FDD call processing error; This setting cannot be changed while SIB15.x messages are being transmitted."

If the length of the message in bits rounded up to the next round number of 4 bits does not equal the number of bits in the message itself then the setting will be rejected with the error "+XXX FDD call processing error; The length of the message and the length field do not match."

If the length of the message is greater than 800 bits then the setting will be rejected with the error "+XXX FDD call processing error; Message size exceeds maximum length for this message type."

Setting

Range: <length of encoded message in bits>, <"ascii string of hex digits defining SIB">

Query

Same as setting

*RST Setting

0, ""

Requirements

Lab Application Revision: E.01 and above

Programming Example

 
OUTPUT 714;"CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point2:MESSage1 0, """
! Sets the First SIB15.2 Message to 0, "".

CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point2:MESSage2

Function

Sets/queries the Second SIB15.2 Message.

This setting can only be changed while SIB15.x Transmission State is Off. If you attempt to change this parameter while SIB15.x Transmission State is On the application will reject the setting with the error "+XXX FDD call processing error; This setting cannot be changed while SIB15.x messages are being transmitted."

If the length of the message in bits rounded up to the next round number of 4 bits does not equal the number of bits in the message itself then the setting will be rejected with the error "+XXX FDD call processing error; The length of the message and the length field do not match."

If the length of the message is greater than 800 bits then the setting will be rejected with the error "+XXX FDD call processing error; Message size exceeds maximum length for this message type."

Setting

Range: <length of encoded message in bits>, <"ascii string of hex digits defining SIB">

Query

Same as setting

*RST Setting

0, ""

Requirements

Lab Application Revision: E.01 and above

Programming Example

 
OUTPUT 714;"CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point2:MESSage2 0, """
! Sets the Second SIB15.2 Message to 0, "".

CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point3:MESSage1

Function

Sets/queries the First SIB15.3 Message.

This setting can only be changed while SIB15.x Transmission State is Off. If you attempt to change this parameter while SIB15.x Transmission State is On the application will reject the setting with the error "+XXX FDD call processing error; This setting cannot be changed while SIB15.x messages are being transmitted."

If the length of the message in bits rounded up to the next round number of 4 bits does not equal the number of bits in the message itself then the setting will be rejected with the error "+XXX FDD call processing error; The length of the message and the length field do not match."

If the length of the message is greater than 3552 bits then the setting will be rejected with the error "+XXX FDD call processing error; Message size exceeds maximum length for this message type."

Setting

Range: <length of encoded message in bits>, <"ascii string of hex digits defining SIB">

Query

Same as setting

*RST Setting

0, ""

Requirements

Lab Application Revision: E.01 and above

Programming Example

 
OUTPUT 714;"CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point3:MESSage1 0, """
! Sets the First SIB15.3 Message to 0, "".

CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point3:MESSage2

Function

Sets/queries the Second SIB15.3 Message.

This setting can only be changed while SIB15.x Transmission State is Off. If you attempt to change this parameter while SIB15.x Transmission State is On the application will reject the setting with the error "+XXX FDD call processing error; This setting cannot be changed while SIB15.x messages are being transmitted."

If the length of the message in bits rounded up to the next round number of 4 bits does not equal the number of bits in the message itself then the setting will be rejected with the error "+XXX FDD call processing error; The length of the message and the length field do not match."

If the length of the message is greater than 3552 bits then the setting will be rejected with the error "+XXX FDD call processing error; Message size exceeds maximum length for this message type."

Setting

Range: <length of encoded message in bits>, <"ascii string of hex digits defining SIB">

Query

Same as setting

*RST Setting

0, ""

Requirements

Lab Application Revision: E.01 and above

Programming Example

 
OUTPUT 714;"CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point3:MESSage2 0, """
! Sets the Second SIB15.3 Message to 0, "".

CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point4

Function

Sets/queries the SIB15.4 Message.

This setting can only be changed while SIB15.x Transmission State is Off. If you attempt to change this parameter while SIB15.x Transmission State is On the application will reject the setting with the error "+XXX FDD call processing error; This setting cannot be changed while SIB15.x messages are being transmitted."

If the length of the message in bits rounded up to the next round number of 4 bits does not equal the number of bits in the message itself then the setting will be rejected with the error "+XXX FDD call processing error; The length of the message and the length field do not match."

If the length of the message is greater than 3552 bits then the setting will be rejected with the error "+XXX FDD call processing error; Message size exceeds maximum length for this message type."

Setting

Range: <length of encoded message in bits>, <"ascii string of hex digits defining SIB">

Query

Same as setting

*RST Setting

0, ""

Requirements

Lab Application Revision: E.01 and above

Programming Example

 
OUTPUT 714;"CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point4 0, """
! Sets the SIB15.4 Message to 0, "".

CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point5

Function

Sets/queries the SIB15.5 Message.

This setting can only be changed while SIB15.x Transmission State is Off. If you attempt to change this parameter while SIB15.x Transmission State is On the application will reject the setting with the error "+XXX FDD call processing error; This setting cannot be changed while SIB15.x messages are being transmitted."

If the length of the message in bits rounded up to the next round number of 4 bits does not equal the number of bits in the message itself then the setting will be rejected with the error "+XXX FDD call processing error; The length of the message and the length field do not match."

If the length of the message is greater than 3552 bits then the setting will be rejected with the error "+XXX FDD call processing error; Message size exceeds maximum length for this message type."

Setting

Range: <length of encoded message in bits>, <"ascii string of hex digits defining SIB">

Query

Same as setting

*RST Setting

0, ""

Requirements

Lab Application Revision: E.01 and above

Programming Example

 
OUTPUT 714;"CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point4 0, """
! Sets the SIB15.5 Message to 0, "".

CALL[:CELL]:BCCHannel:SIB15:TRANsmit[:STATe]

Function

Sets/queries the SIB15.x Transmission State.

This setting controls whether the user supplied SIB15.x messages will be transmitted by the application. Changing this setting (either to On or Off) will not affect any user supplied messages that have been stored by the application.If this setting is "On" and GPS Time Sync State is "On" then the application will update the GPS time parameters in the transmitted SIB15.X messages.This setting has no effect in any Cell Operating Mode other than Active Cell.

Setting

Range: 1|ON|0|OFF

Query

1|0

*RST Setting

0 (off)

Requirements

Lab Application Revision: E.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:SIB15:TRANsmit 0"
! Sets the SIB15.x Transmission State to Off.

CALL[:CELL]:BCCHannel:SRASearch[:SVALue]

Function

The setting form of this command performs two functions: (1) sets the Sintrasearch value (see CALL[:CELL]:BCCHannel:SRASearch:VALue ) and (2) sets the Sintrasearch state to on (see CALL[:CELL]:BCCHannel:SRASearch:STATe ).

The query form of this command returns the Sintrasearch value.

This setting can only be changed when call status is Idle . If BCCH Update Page is set to Auto and you change this setting while your UE is camped to the test set, the test set performs a Broadcast Channel (BCCH) Update Procedure (SIB Contents) . If BCCH Update Page is set to Inhibit (the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see BCCH Update Page for more details).

Setting

Range: -32 dB to 20 dB

Resolution: 2 dB

Sintrasearch can be set to any even number value between -32 dB and +20 dB, but any negative value will be interpreted by the UE as 0 dB.

Query

Same as setting

*RST Setting

Value = 0 dB

State = On

Requirements

Lab Application Revision: C.02 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:SRASearch 4"
! Sets Sintrasearch state to on and sets Sintrasearch value to 4 dB.

CALL[:CELL]:BCCHannel:SRASearch:STATe

Function

Sets/queries the Sintrasearch state. The Sintrasearch state can also be set using the CALL[:CELL]:BCCHannel:SRASearch[:SVALue] command.

This parameter can only be set when call status is Idle . Changing this setting results in the execution of the Broadcast Channel (BCCH) Update Procedure (SIB Contents) if BCCH Update Page is set to Auto .

Setting

Range: 1|ON|0|OFF

Query

1|0

*RST Setting

1 (on)

Requirements

Lab Application Revision: C.02 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:SRASearch:STATe OFF"
! Turns Sintrasearch state off.

CALL[:CELL]:BCCHannel:SRASearch:VALue

Function

Sets/queries the Sintrasearch value. The Sintrasearch value can also be set using the CALL[:CELL]:BCCHannel:SRASearch[:SVALue] command.

This parameter can only be set when call status is Idle . Changing this setting results in the execution of the Broadcast Channel (BCCH) Update Procedure (SIB Contents) if BCCH Update Page is set to Auto .

Setting

Range: -32 dB to 20 dB

Resolution: 2 dB

Sintrasearch can be set to any even number value between -32 dB and +20 dB, but any negative value will be interpreted by the UE as 0 dB.

Query

Same as setting

*RST Setting

0 dB

Requirements

Lab Application Revision: C.02 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:SRASearch:VALue 4 DB"
! Sets the Sintrasearch value to 4 dB.

CALL[:CELL]:BCCHannel:T300

Function

Sets/queries the T300 RRC Conn Req Retransmit Timer .

This setting can only be changed when call status is Idle . If BCCH Update Page is set to Auto and you change this setting while your UE is camped to the test set, the test set performs a Broadcast Channel (BCCH) Update Procedure (SIB Contents) . If BCCH Update Page is set to Inhibit (the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see BCCH Update Page for more details).

Setting

Range: MS100 | MS200 | MS400 | MS600 | MS800 | MS1000 | MS1200 | MS1400 | MS1600 | MS1800 | MS2000 | MS3000 | MS4000 | MS6000 | MS8000

Query

Same as setting

*RST Setting

MS400

Requirements

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:T300 MS400"
! Sets the T300 Timer to 400 ms.

CALL[:CELL]:BCCHannel:T308

Function

Sets/queries the T308 RRC Conn Release Comp Retransmit Timer .

Setting

Range: MS40 | MS80 | MS160 | MS320

Query

Same as setting

*RST Setting

MS40

Requirements

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:T308 MS40"
! Sets the T308 Timer to 40 ms.

CALL[:CELL]:BCCHannel:T309

Function

Sets/queries the T309 CCO From UTRAN to 2G Connect Timer .

This setting can only be changed when call status is Idle . If BCCH Update Page is set to Auto and you change this setting while your UE is camped to the test set, the test set performs a Broadcast Channel (BCCH) Update Procedure (SIB Contents) . If BCCH Update Page is set to Inhibit (the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see BCCH Update Page for more details).

Setting

Range: 0 to 8 seconds

Resolution: 1 second

Query

Same as setting

*RST Setting

8 seconds

Requirements

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:T309 8"
! Sets the T309 Timer to 8 seconds.

CALL[:CELL]:BCCHannel:T312[:IDLE]

Function

Sets/queries the T312 Link Establishment Timer (Idle) .

This setting can only be changed when call status is Idle . If BCCH Update Page is set to Auto and you change this setting while your UE is camped to the test set, the test set performs a Broadcast Channel (BCCH) Update Procedure (SIB Contents) . If BCCH Update Page is set to Inhibit (the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see BCCH Update Page for more details).

Setting

Range: 1 to 15

Resolution: 1

Query

Same as setting

*RST Setting

5

Requirements

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:T312 5"
! Sets the T308 Timer to 40 ms.

CALL[:CELL]:BCCHannel:T313

Function

Sets/queries the T313 Out-Of-Sync Reception Timer .

This setting can only be changed when call status is Idle . If BCCH Update Page is set to Auto and you change this setting while your UE is camped to the test set, the test set performs a Broadcast Channel (BCCH) Update Procedure (SIB Contents) . If BCCH Update Page is set to Inhibit (the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see BCCH Update Page for more details).

Setting

Range: 0 to 15 seconds

Resolution: 1 second

Query

Same as setting

*RST Setting

3 seconds

Requirements

Test Application Revision: A.06 and above

Lab Application Revision: C.01 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:T313 15"
! Sets the T313 UE Link Reestablishment Timer to 15 seconds.

CALL[:CELL]:BCCHannel:T3212

Function

Sets/queries the T312 Link Establishment Timer (Idle) .

This parameter can only be set when call status is Idle . Changing this setting results in the execution of the Broadcast Channel (BCCH) Update Procedure (SIB Contents) if BCCH Update Page is set to Auto .

Setting

Range: 0 to 255

Resolution: 1

Query

Same as setting

*RST Setting

0

Requirements

Lab Application Revision: C.03 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:T3212 10"
! Sets T3212 Periodic Location Update Timer to 10 decihours (1 hour).

CALL[:CELL]:BCCHannel:T3312[:VALue]

Function

Sets/queries the T3312 Periodic RA Update Timer .

To set the units for this timer, see CALL[:CELL]:BCCHannel:T3312:UNITs .

Setting

Range: 0 to 31

Resolution: 1

Query

Same as setting

*RST Setting

10

Requirements

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:T3312 10"
! Sets T3312 Timer to 10.

CALL[:CELL]:BCCHannel:T3312:UNITs

Function

Sets/queries the T3312 Periodic RA Update Units .

To set the value for this timer, see CALL[:CELL]:BCCHannel:T3312[:VALue] .

Setting

Range: SEC2 | MINutes | DHOurs | DEACtivated

Query

Range: SEC2 | MIN | DHO | DEAC

*RST Setting

DEAC

Requirements

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:T3312:UNITs DEAC"
! Sets T3312 timer's units to DEACtivated.

CALL[:CELL]:BCCHannel:UPDAtepage

Function

Sets/queries the BCCH Update Page state (see BCCH Update Page and Broadcast Channel (BCCH) Update Procedure (SIB Contents) ).

Setting

Range: AUTO|INHibit

Query

Range: AUTO|INH

*RST Setting

INH

Requirements

Test Application Revision: A.04 and above

Lab Application Revision: A.02 and above

Programming Example

 
OUTPUT 714;"CALL:BCCHannel:UPDAtepage AUTO"
! Instructs the test set to send a Paging Type 1 message
! to the UE when a BCCH Update has occurred.


Top of pagetop of page     

+ +