CALL:BCCHannel
Last updated: May 26, 2009
GPIB Command Conventions
CALL[:CELL]:BCCHannel:CELLlist
|
Function
|
Sets/queries the
Cell Info List
setting.
This parameter can only be set when call status is
Idle
. Changing this setting results in the execution of the
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
if
BCCH Update Page
is set to
Auto
.
|
|
Setting
|
Range: PRESent|ABSent
|
|
Query
|
Range: PRES|ABS
|
|
*RST Setting
|
PRES |
|
Requirements |
Test Application Revision: A.03 and above.
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:CELLlist PRESent"
! Selects BCCH Cell Info List to preset on the BCCH.
|
CALL[:CELL]:BCCHannel:FBINdicator:STATe
|
Function
|
Sets/queries the
Frequency Band Indicator State
setting.
This setting cannot be changed in active cell operating mode.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
1|0 |
|
*RST Setting
|
1 (on) |
|
Requirements |
Test Application Revision: A.08 and above.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:FBINdicator:STATe OFF"
! Turns Frequency Band Indicator State off.
|
CALL[:CELL]:BCCHannel:FMOCcasion:CLCoeff
|
Function
|
Sets/queries the BCCH SIB11 FACH measurement occasion cycle length coefficient.
This setting is used to calculate the measurement occasion cycle length.
|
|
Setting
|
Range: 1 to 12
Resolution: 1
|
|
Query
|
Range: same as setting
|
|
*RST Setting
|
3 |
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:FMOCcasion:CLCoeff 3"
! Sets the BCCH SIB11 FACH measurement occasion cycle length coefficient to 3.
|
CALL[:CELL]:BCCHannel:FMOCcasion:CLCoeff:CONTrol
|
Function
|
Sets/queries the BCCH SIB11 FACH measurement occasion cycle length coefficient control setting.
This setting determines whether the "FACH measurement occasion cycle length coefficient" parameter should be present in "FACH measurement occasion info".
|
|
Setting
|
Range: PRESent|ABSent
|
|
Query
|
Range: PRES|ABS
|
|
*RST Setting
|
PRESent |
|
Requirements |
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:FMOCcasion:CLCoeff:CONTrol PRESent"!
|
CALL[:CELL]:BCCHannel:FMOCcasion:CONTrol
|
Function
|
Sets/queries the BCCH SIB11 FACH measurement occasion info Present setting.
This setting determines whether the SIB11 includes the IE of "FACH measurement occasion info".
|
|
Setting
|
Range: PRESent|ABSent
|
|
Query
|
Range: PRES|ABS
|
|
*RST Setting
|
ABSent |
|
Requirements |
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:FMOCcasion:CONTrol ABSent"
|
CALL[:CELL]:BCCHannel:FMOCcasion:FDDIndicator
|
Function
|
Sets/queries the BCCH SIB 11 Inter-frequency FDD measurement indicator:
-
When set to 1, the UE performs measurements and evaluate cell reselection criteria on inter-frequency FDD cells listed in SIB11 in CELL_FACH state.
-
When set to 0, the UE should neither perform measurements nor evaluate cell re-selection criteria on inter-frequency FDD cells in CELL_FACH state.
|
|
Setting
|
Range: 1|0
|
|
Query
|
1|0 |
|
*RST Setting
|
1 |
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:FMOCcasion:FDDIndicator 1"
|
CALL[:CELL]:BCCHannel:FMOCcasion:RATIndicator:CONTrol
|
Function
|
Sets/queries the BCCH SIB 11 Inter-RAT measurement indicators control setting.
This setting determines whether "Inter-RAT measurement indicators" and the associated "RAT type" should be present in "FACH measurement occasion info". Currently, the "Inter-RAT measurement indicators" is fixed at 1 and the "RAT type" is fixed to GSM. If this setting is set to Present, the UE performs measurements and evaluates cell reselection criteria on GSM cells that are listed in SIB11 in CELL_FACH state.
|
|
Setting
|
Range: PRESent|ABSent
|
|
Query
|
Range: PRES|ABS
|
|
*RST Setting
|
PRESent |
|
Requirements |
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:FMOCcasion:RATIndicator:CONTrol PRESent"
! Sets the BCCH SIB 11 Inter-RAT measurement indicators control setting to Present.
|
CALL[:CELL]:BCCHannel:GSMSystem:BAND
|
Function
|
Sets/queries the band for each of the 8 GSM neighbor cells (see
GSM Cells
).
This parameter can only be set when call status is
Idle
. Changing this setting results in the execution of the
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
if
BCCH Update Page
is set to
Auto
.
|
|
Setting
|
Range: DCS1800|PCS1900,DCS1800|PCS1900,DCS1800|PCS1900,
DCS1800|PCS1900,DCS1800|PCS1900,DCS1800|PCS1900,
DCS1800|PCS1900,DCS1800|PCS1900
The command
must
be issued with a comma-separated list of
8
values. Each value in the list defines the band for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell list transmitted by the test set is controlled by the
CALL[:CELL]:BCCHannel:GSMSystem:STATe
setting.
|
|
Query
|
Range: same as setting
|
|
*RST Setting
|
DCS1800,DCS1800,DCS1800,DCS1800,DCS1800,DCS1800,DCS1800,DCS1800, |
|
Requirements
|
Test Application Revision: A.05 and above.
Lab Application Revision: B.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:GSMSystem:BAND PCS1900,PCS1900,PCS1900,PCS1900,PCS1900,
PCS1900,PCS1900,PCS1900"
! Sets the band for each of the 8 GSM neighbor cells to PCS1900.
|
CALL[:CELL]:BCCHannel:GSMSystem:BCC
|
Function
|
Sets/queries the BCC for each of the 8 GSM neighbor cells (see
GSM Cells
).
This parameter can only be set when call status is
Idle
. Changing this setting results in the execution of the
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
if
BCCH Update Page
is set to
Auto
.
|
|
Setting
|
Range: 0 to 7
Resolution: 1
The command
must
be issued with a comma-separated list of
8
values. Each value in the list defines the BCC for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell list transmitted by the test set is controlled by the
CALL[:CELL]:BCCHannel:GSMSystem:STATe
setting.
|
|
Query
|
Range: same as setting
|
|
*RST Setting
|
5,0,1,2,3,4,6,7 |
|
Requirements
|
Test Application Revision: A.05 and above.
Lab Application Revision: B.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:GSMSystem:BCC 4,1,3,6,0,7,2,5"
! Sets the BCC for the first GSM neighbor cell to 4,
! sets the BCC for the second GSm neighbor cell to 1, etc.
|
CALL[:CELL]:BCCHannel:GSMSystem:BCHannel
|
Function
|
Sets/queries the BCH ARFCN for each of the 8 GSM neighbor cells (see
GSM Cells
).
This parameter can only be set when call status is
Idle
. Changing this setting results in the execution of the
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
if
BCCH Update Page
is set to
Auto
.
|
|
Setting
|
Range: 0 to 1023
Resolution: 1
The command
must
be issued with a comma-separated list of
8
values. Each value in the list defines the BCH ARFCN for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell list transmitted by the test set is controlled by the
CALL[:CELL]:BCCHannel:GSMSystem:STATe
setting.
|
|
Query
|
Range: same as setting
|
|
*RST Setting
|
20,30,40,50,60,70,80,90 |
|
Requirements
|
Test Application Revision: A.05 and above.
Lab Application Revision: B.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:GSMSystem:BCHannel 22,32,42,52,62,72,82,92"
! Sets the BCH ARFCN for the first GSM neighbor cell to 22,
! sets the BCC for the second GSm neighbor cell to 32, etc.
|
CALL[:CELL]:BCCHannel:GSMSystem:NCC
|
Function
|
Sets/queries the NCC for each of the 8 GSM neighbor cells (see
GSM Cells
).
This parameter can only be set when call status is
Idle
. Changing this setting results in the execution of the
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
if
BCCH Update Page
is set to
Auto
.
|
|
Setting
|
Range: 0 to 7
Resolution: 1
The command
must
be issued with a comma-separated list of
8
values. Each value in the list defines the NCC for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell list transmitted by the test set is controlled by the
CALL[:CELL]:BCCHannel:GSMSystem:STATe
setting.
|
|
Query
|
Range: same as setting
|
|
*RST Setting
|
1, 0, 2, 3, 4, 5, 6, 7 |
|
Requirements
|
Test Application Revision: A.05 and above.
Lab Application Revision: B.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:GSMSystem:NCC 7,1,6,3,0,4,5,2"
! Sets the NCC for the first GSM neighbor cell to 7,
! sets the NCC for the second GSm neighbor cell to 1, etc.
|
CALL[:CELL]:BCCHannel:GSMSystem:CRESelection:RLMinimum
|
Function
|
Sets/queries
GSM <num> Cell Cell Reselection Min Rx Level
for each of the 8 GSM neighbor cells.
This parameter can only be set when call status is
Idle
. Changing this setting results in the execution of the
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
if
BCCH Update Page
is set to
Auto
.
|
|
Setting
|
Range: -115 to -25 dBm
Resolution: 1 dB
The command
must
be issued with a comma-separated list of
8
values. Each value in the list defines the
Cell Reselection Min Rx Level
for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell list transmitted by the test set is controlled by the
CALL[:CELL]:BCCHannel:GSMSystem:STATe
setting.
|
|
Query
|
Range: same as setting
|
|
*RST Setting
|
-104,-104,-104,-104,-104,-104,-104,-104 (dBm) |
|
Requirements
|
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:GSMSystem:CRESelection:RLMinimum
-100,-100,-100,-100,-100,-100,-100,-100"
! Sets Cell Reselection Min Rx Level for the first GSM neighbor cell to -100 dBm,
! sets Cell Reselection Min Rx Level for the second GSM neighbor cell to -100 dBm, etc.
|
CALL[:CELL]:BCCHannel:GSMSystem:STATe
|
Function
|
Sets/queries whether each of the 8 GSM neighbor cells is included in the cell info list transmitted by the test set (see
GSM Cells
).
This parameter can only be set when call status is
Idle
. Changing this setting results in the execution of the
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
if
BCCH Update Page
is set to
Auto
.
|
|
Setting
|
Range: 1|ON|0|OFF
The command must be issued with a comma-separated list of 8 valid settings.
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1,0,0,0,0,0,0,0 |
|
Requirements
|
Test Application Revision: A.05 and above.
Lab Application Revision: B.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:GSMSystem:STATe 1,1,1,1,1,1,1,1"
! Includes all 8 GSM neighbor cells in the cell info list.
|
CALL[:CELL]:BCCHannel:INTERFREQ:DOWNlink:CHANnel
|
Function
|
THIS COMMAND IS OBSOLETE. Please use the
CALL[:CELL]:BCCHannel:ITRFrequency:DOWNlink:CHANnel
command.
Sets/queries the downlink channel number (DL UARFCN) of the Inter-frequency cell info list which is included in the System Information Block (SIB) 11 on the BCCH. The Inter-frequency cell info list contains only one cell.
This setting is available only when the BCCH SIB 11 Cell Info List is set to "Present" (see
CALL[:CELL]:BCCHannel:CELLlist
).
If this setting is changed while the Operating Mode is "Active Cell.", the test set will perform the BCCH Update procedure.
|
|
Setting
|
Range:
-
412 - 687
-
4320 - 4495
-
4600 - 4825
-
9000 - 9425
-
9625 - 9975
-
10,525 - 10,875
|
|
Query
|
Range: Same as settings
|
|
*RST Setting
|
10730
|
|
Requirements |
Test Application Revision: A.03 and above.
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:INTERFREQ:DOWNlink:CHANnel 10735"
! Sets the BCCH Inter-frequency Cell DL UARFCN to 10735.
|
CALL[:CELL]:BCCHannel:INTERFREQ:SCODe
|
Function
|
THIS COMMAND IS OBSOLETE. Please use the
CALL[:CELL]:BCCHannel:ITRFrequency:SCODe
command.
Sets/queries the primary scrambling code of the Inter-frequency cell info list which is included in the System Information Block (SIB) 11 on the BCCH. The Inter-frequency cell info list contains only one cell.
This setting is available only when the BCCH SIB 11 Cell Info List is set to "Present" (see
CALL[:CELL]:BCCHannel:CELLlist
).
If this setting is changed while the Operating Mode is "Active Cell.", the test set will perform the BCCH Update procedure.
|
|
Setting
|
Range: 0 to 511
Resolution: 1
|
|
Query
|
Range: same as settings
|
|
*RST Setting
|
63
|
|
Requirements
|
Test Application Revision: A.03 and above.
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:INTERFREQ:SCODe 63"
! Sets the BCCH Inter-frequency Cell Scrambling Code to 63.
|
CALL[:CELL]:BCCHannel:INTRAFREQ:CELL2:SCODe
|
Function
|
THIS COMMAND IS OBSOLETE. Please use the
CALL[:CELL]:BCCHannel:ITAFrequency:SCODe
command.
Sets/queries the primary scrambling code of the 2nd cell in the Intra-frequency cell info list which is included in the System Information Block (SIB) 11 on the BCCH. This setting is available only when the BCCH SIB 11 Cell Info List is set to "Present" (see
CALL[:CELL]:BCCHannel:CELLlist
).
The Intra-frequency cell info list contains three cells. As required by the W-CDMA specifications, Cell 1 in this list is always the serving cell so the cell information is automatically set to match the test set's cell.
If this setting is changed while the Operating Mode is "Active Cell.", the test set will perform the BCCH Update procedure.
|
|
Setting
|
Range: 0 to511
Resolution: 1
|
|
Query
|
Range: same as settings
|
|
*RST Setting
|
127
|
|
Requirements
|
Test Application Revision: A.03 and above.
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:INTRAFREQ:CELL2:SCODe 130"
! Sets the BCCH Intra-frequency Cell 2 Scrambling Code to 130.
|
CALL[:CELL]:BCCHannel:INTRAFREQ:CELL3:SCODe
|
Function
|
THIS COMMAND IS OBSOLETE. Please use the
CALL[:CELL]:BCCHannel:ITAFrequency:SCODe
command.
Sets/queries the primary scrambling code of the 3rd cell in the Intra-frequency cell info list which is included in the System Information Block (SIB) 11 on the BCCH. This setting is available only when the BCCH SIB 11 Cell Info List is set to "Present" (see
CALL[:CELL]:BCCHannel:CELLlist
).
The Intra-frequency cell info list contains three cells. As required by the W-CDMA specifications, Cell 1 in this list is always the serving cell so the cell information is automatically set to match the test set's cell.
If this setting is changed while the Operating Mode is "Active Cell.", the test set will perform the BCCH Update procedure.
|
|
Setting
|
Range: 0 - 511
Resolution: 1
|
|
Query
|
Range: same as settings
|
|
*RST Setting
|
511
|
|
Requirements
|
Test Application Revision: A.03 and above.
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:INTRAFREQ:CELL3:SCODe 500"
! Sets the BCCH Intra-frequency Cell 3 Scrambling Code to 500.
|
CALL[:CELL]:BCCHannel:ITAFrequency:CRESelection:OFFSet[1]
|
Function
|
Sets/queries
Intra-freq <num> Cell Cell Reselection Offset1
for each of the 8 intra-frequency neighbor cells.
This parameter can only be set when call status is
Idle
. Changing this setting results in the execution of the
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
if
BCCH Update Page
is set to
Auto
.
|
|
Setting
|
Range: -50 to 50 dB
Resolution: 1 dB
The command
must
be issued with a comma-separated list of
8
values. Each value in the list defines the
Cell Reselection Offset1
for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell list transmitted by the test set is controlled by the
CALL[:CELL]:BCCHannel:ITAFrequency:STATe
setting.
|
|
Query
|
Range: same as setting
|
|
*RST Setting
|
0,0,0,0,0,0,0,0 (dB) |
|
Requirements
|
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:ITAFrequency:CRESelection:OFFSet -20,-20,-20,-20,-20,-20,-20,-20"
! Sets Cell Reselection Offset1 for the first intra-frequency neighbor cell to -20 dB,
! sets Cell Reselection Offset1 for the second intra-frequency neighbor cell to -20 dB, etc.
|
CALL[:CELL]:BCCHannel:ITAFrequency:CRESelection:OFFSet2
|
Function
|
Sets/queries
Intra-freq <num> Cell Cell Reselection Offset2
for each of the 8 intra-frequency neighbor cells.
This parameter can only be set when call status is
Idle
. Changing this setting results in the execution of the
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
if
BCCH Update Page
is set to
Auto
.
|
|
Setting
|
Range: -50 to 50 dB
Resolution: 1 dB
The command
must
be issued with a comma-separated list of
8
values. Each value in the list defines the
Cell Reselection Offset2
for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell list transmitted by the test set is controlled by the
CALL[:CELL]:BCCHannel:ITAFrequency:STATe
setting.
|
|
Query
|
Range: same as setting
|
|
*RST Setting
|
0,0,0,0,0,0,0,0 (dB) |
|
Requirements
|
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:ITAFrequency:CRESelection:OFFSet2 -20,-20,-20,-20,-20,-20,-20,-20"
! Sets Cell Reselection Offset2 for the first intra-frequency neighbor cell to -20 dB,
! sets Cell Reselection Offset2 for the second intra-frequency neighbor cell to -20 dB, etc.
|
CALL[:CELL]:BCCHannel:ITAFrequency:SCODe
|
Function
|
Sets/queries the primary scrambling code for each of the 8 intra frequency neighbor cells (see
Intra-frequency Cells
).
This parameter can only be set when call status is
Idle
. Changing this setting results in the execution of the
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
if
BCCH Update Page
is set to
Auto
.
|
|
Setting
|
Range: 0 to 511
Resolution: 1
The command
must
be issued with a comma-separated list of
8
values. Each value in the list defines the primary scrambling code for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell info list transmitted by the test set is controlled by the
CALL[:CELL]:BCCHannel:ITAFrequency:STATe
setting.
|
|
Query
|
Range: same as setting
|
|
*RST Setting
|
0,127,191,255,319,383,447,511 |
|
Requirements
|
Test Application Revision: A.05 and above.
Lab Application Revision: B.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:ITAFrequency:SCODe 0,127,192,255,320,384,448,511"
! Sets the scrambling code for the first intra frequency neighbor
! cell to 0, sets the scrambling code for the second intra
! frequency neighbor cell to 127, etc.
|
CALL[:CELL]:BCCHannel:ITAFrequency:STATe
|
Function
|
Sets/queries whether each of the 8 intra frequency neighbor cells is included in the cell info list transmitted by the test set (see
Intra-frequency Cells
).
Changing this setting results in the execution of the
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
if
BCCH Update Page
is set to
Auto
.
|
|
Setting
|
Range: 1|ON|0|OFF
The command must be issued with a comma-separated list of 8 valid settings.
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1,1,0,0,0,0,0,0 |
|
Requirements
|
Test Application Revision: A.05 and above.
Lab Application Revision: B.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:ITAFrequency:STATe 1,1,1,1,1,1,1,1"
! Includes all 8 intra frequency neighbor cells in the
! cell info list.
|
CALL[:CELL]:BCCHannel:ITRFrequency:CRESelection:OFFSet[1]
|
Function
|
Sets/queries
Inter-freq <num> Cell Cell Reselection Offset1
for each of the 8 intra-frequency neighbor cells.
This parameter can only be set when call status is
Idle
. Changing this setting results in the execution of the
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
if
BCCH Update Page
is set to
Auto
.
|
|
Setting
|
Range: -50 to 50 dB
Resolution: 1 dB
The command
must
be issued with a comma-separated list of
8
values. Each value in the list defines the
Cell Reselection Offset1
for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell list transmitted by the test set is controlled by the
CALL[:CELL]:BCCHannel:ITRFrequency:STATe
setting.
|
|
Query
|
Range: same as setting
|
|
*RST Setting
|
0,0,0,0,0,0,0,0 (dB) |
|
Requirements
|
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:ITRFrequency:CRESelection:OFFSet -20,-20,-20,-20,-20,-20,-20,-20"
! Sets Cell Reselection Offset1 for the first inter-frequency neighbor cell to -20 dB,
! sets Cell Reselection Offset1 for the second inter-frequency neighbor cell to -20 dB, etc.
|
CALL[:CELL]:BCCHannel:ITRFrequency:CRESelection:OFFSet2
|
Function
|
Sets/queries
Inter-freq <num> Cell Cell Reselection Offset2
for each of the 8 intra-frequency neighbor cells.
This parameter can only be set when call status is
Idle
. Changing this setting results in the execution of the
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
if
BCCH Update Page
is set to
Auto
.
|
|
Setting
|
Range: -50 to 50 dB
Resolution: 1 dB
The command
must
be issued with a comma-separated list of
8
values. Each value in the list defines the
Cell Reselection Offset2
for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell list transmitted by the test set is controlled by the
CALL[:CELL]:BCCHannel:ITRFrequency:STATe
setting.
|
|
Query
|
Range: same as setting
|
|
*RST Setting
|
0,0,0,0,0,0,0,0 (dB) |
|
Requirements
|
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:ITRFrequency:CRESelection:OFFSet2 -20,-20,-20,-20,-20,-20,-20,-20"
! Sets Cell Reselection Offset2 for the first inter-frequency neighbor cell to -20 dB,
! sets Cell Reselection Offset2 for the second inter-frequency neighbor cell to -20 dB, etc.
|
CALL[:CELL]:BCCHannel:ITRFrequency:DOWNlink:CHANnel
|
Function
|
Sets/queries the UARFCN for each of the 8 inter frequency neighbor cells (see
Inter-frequency Cells
).
This parameter can only be set when call status is
Idle
. Changing this setting results in the execution of the
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
if
BCCH Update Page
is set to
Auto
.
|
|
Setting
|
Range:
-
412, 437, 462, 487, 512, 537, 562, 587, 612, 637, 662, 687
-
1007, 1012, 1032, 1037, 1062, 1087
-
1162 - 1513, resolution = 1
-
1537 - 1738, resolution = 1
-
1887, 1912, 1937, 1962, 1987, 2012, 2037, 2062, 2087
-
2237 - 2563, resolution = 1
-
2587, 2612, 2637, 2662, 2687, 2712, 2737, 2762, 2787, 2812, 2837, 2862, 2887, 2912
-
2937 - 3088, resolution = 1
-
3112 to 3388, resolution = 1
-
3412, 3437, 3462, 3487, 3512, 3537, 3562, 3587, 3612, 3637, 3662, 3687
-
3837 - 3903, resolution = 1
-
3927, 3932, 3957, 3962, 3987, 3992
-
4017 - 4043, resolution = 1
-
4067, 4092
-
4117 - 4143, resolution = 1
-
4167, 4192
-
4357 - 4458, resolution = 1
-
9237 - 9387, resolution = 1
-
9662 - 9938, resolution = 1
-
10562 - 10838, resolution = 1
The command
must
be issued with a comma-separated list of
8
values. Each value in the list defines the UARFCN for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell info list transmitted by the test set is controlled by the
CALL[:CELL]:BCCHannel:ITRFrequency:STATe
setting.
|
|
Query
|
Range: same as setting
|
|
*RST Setting
|
10730,10730,10730,10730,10730,10730,10730,10730 |
|
Requirements
|
Test Application Revision: A.05 and above.
Lab Application Revision: B.01 and above
Test Application Revision: A.05.28 and above, added 1037 - 1062.
Lab Application Revision: B.01 and above
Lab Application Revision: B.01.29 and above, added 1037 - 1062.
Test Application Revision A.09 and Lab Application Revision C.04 and D.00, changed channel ranges to match 3GPP TS 25.101 v7.2.0 (previously, channels supported were: 412-687, 1037-1062, 4320-4495, 4600-4825, 9000-9425, 9625-9975, and 10,525-10,875, resolution = 1).
Test Application Revision A.11 and Lab Application Revisions D.02 and E.00, added 3112 to 3388, 3412, 3437, 3462, 3487, 3512, 3537, 3562, 3587, 3612, 3637, 3662, 3687
Test Application Revision A.14 and Lab Application Revision F.00, added 3837 - 3903, 3927, 3932, 3957, 3962, 3987, 3992, 4017 - 4043, 4067, 4092, 4117 - 4143, 4167, 4192
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:ITRFrequency:DOWNlink:CHANnel 10730,10730,10730,10730,
10730,10730,10730,10730"
! Sets the UARFCN for each of the 8 inter frequency neighbor
! cells to 10730.
|
CALL[:CELL]:BCCHannel:ITRFrequency:SCODe
|
Function
|
Sets/queries the primary scrambling code for each of the 8 inter frequency neighbor cells (see
Inter-frequency Cells
).
This parameter can only be set when call status is
Idle
. Changing this setting results in the execution of the
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
if
BCCH Update Page
is set to
Auto
.
|
|
Setting
|
Range: 0 to 511
Resolution: 1
The command
must
be issued with a comma-separated list of
8
values. Each value in the list defines the primary scrambling code for the corresponding neighbor cell (cell 1 through cell 8). Whether each cell is actually present in the cell info list transmitted by the test set is controlled by the
CALL[:CELL]:BCCHannel:ITRFrequency:STATe
setting.
|
|
Query
|
Range: same as setting
|
|
*RST Setting
|
0,127,191,255,319,383,447,511 |
|
Requirements
|
Test Application Revision: A.05 and above.
Lab Application Revision: B.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:ITRFrequency:SCODe 0,127,192,255,320,384,448,511"
! Sets the scrambling code for the first inter frequency neighbor
! cell to 0, sets the scrambling code for the second inter
! frequency neighbor cell to 127, etc.
|
CALL[:CELL]:BCCHannel:ITRFrequency:STATe
|
Function
|
Sets/queries whether each of the 8 inter frequency neighbor cells is included in the cell info list transmitted by the test set (see
Inter-frequency Cells
).
This parameter can only be set when call status is
Idle
. Changing this setting results in the execution of the
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
if
BCCH Update Page
is set to
Auto
.
|
|
Setting
|
Range: 1|ON|0|OFF
The command must be issued with a comma-separated list of 8 valid settings.
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1,0,0,0,0,0,0,0 |
|
Requirements
|
Test Application Revision: A.05 and above.
Lab Application Revision: B.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:ITRFrequency:STATe 1,1,1,1,1,1,1,1"
! Includes all 8 inter frequency neighbor cells in the
! cell info list.
|
CALL[:CELL]:BCCHannel:N300
|
Function
|
Sets/queries the
N300 RRC Conn Req Max Retransmits
.
This setting can only be changed when call status is
Idle
. If
BCCH Update Page
is set to
Auto
and you change this setting while your UE is camped to the test set, the test set performs a
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
. If
BCCH Update Page
is set to
Inhibit
(the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see
BCCH Update Page
for more details).
|
|
Setting
|
Range: 0 to 7
Resolution: 1
|
|
Query
|
Same as setting |
|
*RST Setting
|
0 |
|
Requirements
|
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:N300 0"
! Sets the N300 Constant to 0.
|
CALL[:CELL]:BCCHannel:N312[:IDLE]
|
Function
|
Sets/queries the
N312 Link Establishment In-Sync Count (Idle)
.
This setting can only be changed when call status is
Idle
. If
BCCH Update Page
is set to
Auto
and you change this setting while your UE is camped to the test set, the test set performs a
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
. If
BCCH Update Page
is set to
Inhibit
(the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see
BCCH Update Page
for more details).
|
|
Setting
|
Range: 1, 2, 4, 10, 20, 50, 100, 200, 400, 600, 800, 1000
|
|
Query
|
Same as setting |
|
*RST Setting
|
50 |
|
Requirements
|
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:N312 50"
! Sets the N312 Constant to 50.
|
CALL[:CELL]:BCCHannel:N313
|
Function
|
Sets/queries the
T313 Out-Of-Sync Reception Timer
.
This setting can only be changed when call status is
Idle
. If
BCCH Update Page
is set to
Auto
and you change this setting while your UE is camped to the test set, the test set performs a
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
. If
BCCH Update Page
is set to
Inhibit
(the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see
BCCH Update Page
for more details).
|
|
Setting
|
Range: S1|S2|S4|S10|S20|S50|S100|S200
|
|
Query
|
Same as setting |
|
*RST Setting
|
S2 |
|
Requirements
|
Test Application Revision: A.06 and above
Lab Application Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:N313 S200"
! Sets the N313 UE Out-Of-Sync Counter to S200
|
CALL[:CELL]:BCCHannel:N315
|
Function
|
Sets/queries the
N315 Successive In-Sync Reception Counter
.
This setting can only be changed when call status is
Idle
. If
BCCH Update Page
is set to
Auto
and you change this setting while your UE is camped to the test set, the test set performs a
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
. If
BCCH Update Page
is set to
Inhibit
(the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see
BCCH Update Page
for more details).
|
|
Setting
|
Range: S1|S2|S4|S10|S20|S50|S100|S200|S400|S600|S800|S1000
|
|
Query
|
Same as setting |
|
*RST Setting
|
S50 |
|
Requirements
|
Test Application Revision: A.06 and above
Lab Application Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:N315 S1"
! Sets N315 UE In-Sync Counter to S1.
|
CALL[:CELL]:BCCHannel:SERSearch[:SVALue]
|
Function
|
The setting form of this command performs two functions: (1) sets the
Sintersearch
value (see
CALL[:CELL]:BCCHannel:SERSearch:VALue
) and (2) sets the
Sintersearch
state to on (see
CALL[:CELL]:BCCHannel:SERSearch:STATe
).
The query form of this command returns the
Sintersearch
value.
This setting can only be changed when call status is
Idle
. If
BCCH Update Page
is set to
Auto
and you change this setting while your UE is camped to the test set, the test set performs a
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
. If
BCCH Update Page
is set to
Inhibit
(the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see
BCCH Update Page
for more details).
|
|
Setting
|
Range: -32 dB to 20 dB
Resolution: 2 dB
Sintersearch can be set to any even number value between -32 dB and +20 dB, but any negative value will be interpreted by the UE as 0 dB.
|
|
Query
|
Same as setting |
|
*RST Setting
|
Value = 0 dB
State = On
|
|
Requirements
|
Lab Application Revision: C.02 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:SERSearch 4"
! Sets Sintersearch state to on and sets Sintersearch value to 4 dB.
|
CALL[:CELL]:BCCHannel:SERSearch:STATe
CALL[:CELL]:BCCHannel:SERSearch:VALue
|
Function
|
Sets/queries the
Sintersearch
value. The
Sintersearch
value can also be set using the
CALL[:CELL]:BCCHannel:SERSearch[:SVALue]
command.
This parameter can only be set when call status is
Idle
. Changing this setting results in the execution of the
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
if
BCCH Update Page
is set to
Auto
.
|
|
Setting
|
Range: -32 dB to 20 dB
Resolution: 2 dB
Sintersearch can be set to any even number value between -32 dB and +20 dB, but any negative value will be interpreted by the UE as 0 dB.
|
|
Query
|
Same as setting |
|
*RST Setting
|
0 dB |
|
Requirements
|
Lab Application Revision: C.02 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:SERSearch:VALue 4 DB"
! Sets the Sintersearch value to 4 dB.
|
CALL[:CELL]:BCCHannel:SIB5:BIS
|
Function
|
Sets/queries
Transmit SIB5bis
.
This setting can only be changed when call status is
Idle
. If
BCCH Update Page
is set to
Auto
and you change this setting while your UE is camped to the test set, the test set performs a
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
. If
BCCH Update Page
is set to
Inhibit
(the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see
BCCH Update Page
for more details).
|
|
Setting
|
Range:
-
ALL - All Bands
-
BAND10 - Band X
-
BAND4 - Band IV
-
BAND9 - Band IX
-
BAND49 - Bands IV & IX
-
NONE - No Bands
-
SBANds - Standard Bands
|
|
Query
|
Same as setting |
|
*RST Setting
|
SBAN |
|
Requirements
|
Test Application Revision: A.01.01 and above
Lab Application Revision: D.00.04 and above
Test Application Revision A.11, Lab Application Revisions D.02 and E.00, added BAND10 and SBANds, changed default from BAND49 to SBANds.
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:SIB5:BIS SBANds"
! Sets Transmit SIB5bis to Standard Bands.
|
CALL[:CELL]:BCCHannel:SIB15:GPSystem:TIME:OFFset:TTOWeek
|
Function
|
Sets/queries the GPS Transmission TOW Offset.
This defines a static offset in seconds that is applied to the transmissionTOW IE whenever it is updated in the SIB15.x messages.The purpose of this parameter is to allow you to introduce deliberate errors into the accuracy of GPS time signaled by this IE.
|
|
Setting
|
Range: -30 to +30
Resolution: 1
|
|
Query
|
Same as setting |
|
*RST Setting
|
0 |
|
Requirements
|
Lab Application Revision: E.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:SIB15:GPSystem:TIME:OFFset:TTOWeek 0"
! Sets the GPS Transmission TOW Offset to 0.
|
CALL[:CELL]:BCCHannel:SIB15:GPSystem:TIME:OFFSet:TOWeek:MSECond
|
Function
|
Sets/queries the GPS TOW 1ms Offset.
This defines a static offset in seconds that is applied to gps-tow-1msec IE whenever it is updated in the SIB15.X messages. The purpose of this parameter is to allow you to introduce deliberate errors into the accuracy of GPS time signaled by this IE.
|
|
Setting
|
Range: -5.0 to +5.0 seconds
Resolution: 0.1 seconds
|
|
Query
|
Same as setting |
|
*RST Setting
|
0 seconds |
|
Requirements
|
Lab Application Revision: E.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:SIB15:GPSystem:TIME:OFFSet:TOWeek:MSECond 0"
! Sets the GPS TOW 1ms Offset to 0 seconds.
|
CALL[:CELL]:BCCHannel:SIB15:GPSystem:TIME:OFFSet:UTRan
|
Function
|
Sets/queries the UTRAN GPS TimingOfCell Offset.
This defines a static offset in micro-seconds that will be applied to the utran-GPSTimingOfCell IE (rounded to nearest chip). The purpose of this parameter is to allow you to introduce deliberate errors into the accuracy of GPS time signaled by this IE.
|
|
Setting
|
Range: -100 to +100 microseconds
Resoultion 1 microseconds
|
|
Query
|
Same as setting |
|
*RST Setting
|
0 microseconds |
|
Requirements
|
Lab Application Revision: E.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:SIB15:GPSystem:TIME:OFFSet:UTRan 0"
! Sets the UTRAN GPS TimingOfCell Offset to 0 microseconds.
|
CALL[:CELL]:BCCHannel:SIB15:GPSystem:TIME:REFerence:UPDate[:STATe]
|
Function
|
Sets/queries the GPS Reference Time Update State.
This controls whether the test set updates the utran-GPSReferenceTime IE in SIB15 when the GPS Time Sync State is On. If this parameter is On, then the test set will assume that the encoded SIB15 you supply contains the optional utran-GPSReferenceTime IE.
This setting can only be changed while Section the SIB15.x Transmission State is Off. If you attempt to change this parameter while the SIB15.x Transmission State is On the application will reject the setting with the error "+XXX FDD Call processing error; This setting cannot be changed while SIB15.x messages are being transmitted."
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
1|0 |
|
*RST Setting
|
0 (off) |
|
Requirements
|
Lab Application Revision: E.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:SIB15:GPSystem:TIME:REFerence:UPDate OFF"
! Sets the GPS Reference Time Update State to Off.
|
CALL[:CELL]:BCCHannel:SIB15:GPSystem:TIME:REFerence:SFN
|
Function
|
Sets/queries the GPS Reference Time SFN.
This defines the SFN that is assumed when the test set updates the utran-GPSTimingOfCell parameters in the utran-GPSReferenceTime IE in SIB15. The test set does not set the SFN field in the utran-GPSReferenceTime IE but instead assumes that you have already configured that field in the encoded SIB15 to match this setting.
This setting can only be changed while SIB15.x Transmission State is Off. If you attempt to change this parameter while SIB15.x Transmission State is On, the application will reject the setting with the error "+XXX FDD Call processing error; This setting cannot be changed while SIB15.x messages are being transmitted."
|
|
Setting
|
Range: 0 to 4095
Resolution: 1
|
|
Query
|
Same as setting |
|
*RST Setting
|
0 |
|
Requirements
|
Lab Application Revision: E.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:SIB15:GPSystem:TIME:REFerence:SFN 0"
! Sets the GPS Reference Time SFN to 0.
|
CALL[:CELL]:BCCHannel:SIB15:MESSage:S15
|
Function
|
Sets/queries the SIB15 Message. This defines the encoded SIB15 message that the test set sends out.
Setting <length of encoded message in bits> to zero deletes the stored message.
The Reference Time Offset parameter contains the bit offset of where the ue-positioning-GPS-ReferenceTime IE starts.
This setting can only be changed while SIB15.x Transmission State is Off. If you attempt to change this parameter while SIB15.x Transmission State is On the application will reject the setting with the error "+XXX FDD call processing error; This setting cannot be changed while SIB15.x messages are being transmitted."
If the length of the message in bits rounded up to the next round number of 4 bits does not equal the number of bits in the message itself then the setting will be rejected with the error "+XXX FDD call processing error; The length of the message and the length field do not match."
If the length of the message is greater than 800 bits then the setting will be rejected with the error "+XXX FDD call processing error; Message size exceeds maximum length for this message type."
|
|
Setting
|
Range: <length of encoded message in bits>, <Reference Time Offset in bits>, <"ascii string of hex digits defining">
|
|
Query
|
Same as setting |
|
*RST Setting
|
0, 0, "" |
|
Requirements
|
Lab Application Revision: E.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:SIB15:MESSage:S15 0, 0, """
! Sets the SIB15 message.
|
CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point1
|
Function
|
Sets/queries the SIB15.1 Message. This defines the encoded SIB15.1 message that the test set will send out.
Setting <length of encoded message in bits> to zero deletes the stored message.
This setting can only be changed while SIB15.x Transmission State is Off. If you attempt to change this parameter while SIB15.x Transmission State is On the application will reject the setting with the error "+XXX FDD call processing error; This setting cannot be changed while SIB15.x messages are being transmitted."
If the length of the message in bits rounded up to the next round number of 4 bits does not equal the number of bits in the message itself then the setting will be rejected with the error "+XXX FDD call processing error; The length of the message and the length field do not match."
If the length of the message is greater than 1200 bits then the setting will be rejected with the error "+XXX FDD call processing error; Message size exceeds maximum length for this message type."
|
|
Setting
|
Range: <length of encoded message in bits>, <"ascii string of hex digits defining SIB">
|
|
Query
|
Same as setting |
|
*RST Setting
|
0, "" |
|
Requirements
|
Lab Application Revision: E.01 and above
|
|
Programming Example
OUTPUT 714;"CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point2:MESSage1 0, """
! Sets the SIB15.1 Message to 0, "".
|
CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point2:MESSage1
|
Function
|
Sets/queries the First SIB15.2 Message.
This defines the first encoded SIB15.2 message that the test set will send out.
This setting can only be changed while SIB15.x Transmission State is Off. If you attempt to change this parameter while SIB15.x Transmission State is On the application will reject the setting with the error "+XXX FDD call processing error; This setting cannot be changed while SIB15.x messages are being transmitted."
If the length of the message in bits rounded up to the next round number of 4 bits does not equal the number of bits in the message itself then the setting will be rejected with the error "+XXX FDD call processing error; The length of the message and the length field do not match."
If the length of the message is greater than 800 bits then the setting will be rejected with the error "+XXX FDD call processing error; Message size exceeds maximum length for this message type."
|
|
Setting
|
Range: <length of encoded message in bits>, <"ascii string of hex digits defining SIB">
|
|
Query
|
Same as setting |
|
*RST Setting
|
0, "" |
|
Requirements
|
Lab Application Revision: E.01 and above
|
|
Programming Example
OUTPUT 714;"CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point2:MESSage1 0, """
! Sets the First SIB15.2 Message to 0, "".
|
CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point2:MESSage2
|
Function
|
Sets/queries the Second SIB15.2 Message.
This setting can only be changed while SIB15.x Transmission State is Off. If you attempt to change this parameter while SIB15.x Transmission State is On the application will reject the setting with the error "+XXX FDD call processing error; This setting cannot be changed while SIB15.x messages are being transmitted."
If the length of the message in bits rounded up to the next round number of 4 bits does not equal the number of bits in the message itself then the setting will be rejected with the error "+XXX FDD call processing error; The length of the message and the length field do not match."
If the length of the message is greater than 800 bits then the setting will be rejected with the error "+XXX FDD call processing error; Message size exceeds maximum length for this message type."
|
|
Setting
|
Range: <length of encoded message in bits>, <"ascii string of hex digits defining SIB">
|
|
Query
|
Same as setting |
|
*RST Setting
|
0, "" |
|
Requirements
|
Lab Application Revision: E.01 and above
|
|
Programming Example
OUTPUT 714;"CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point2:MESSage2 0, """
! Sets the Second SIB15.2 Message to 0, "".
|
CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point3:MESSage1
|
Function
|
Sets/queries the First SIB15.3 Message.
This setting can only be changed while SIB15.x Transmission State is Off. If you attempt to change this parameter while SIB15.x Transmission State is On the application will reject the setting with the error "+XXX FDD call processing error; This setting cannot be changed while SIB15.x messages are being transmitted."
If the length of the message in bits rounded up to the next round number of 4 bits does not equal the number of bits in the message itself then the setting will be rejected with the error "+XXX FDD call processing error; The length of the message and the length field do not match."
If the length of the message is greater than 3552 bits then the setting will be rejected with the error "+XXX FDD call processing error; Message size exceeds maximum length for this message type."
|
|
Setting
|
Range: <length of encoded message in bits>, <"ascii string of hex digits defining SIB">
|
|
Query
|
Same as setting |
|
*RST Setting
|
0, "" |
|
Requirements
|
Lab Application Revision: E.01 and above
|
|
Programming Example
OUTPUT 714;"CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point3:MESSage1 0, """
! Sets the First SIB15.3 Message to 0, "".
|
CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point3:MESSage2
|
Function
|
Sets/queries the Second SIB15.3 Message.
This setting can only be changed while SIB15.x Transmission State is Off. If you attempt to change this parameter while SIB15.x Transmission State is On the application will reject the setting with the error "+XXX FDD call processing error; This setting cannot be changed while SIB15.x messages are being transmitted."
If the length of the message in bits rounded up to the next round number of 4 bits does not equal the number of bits in the message itself then the setting will be rejected with the error "+XXX FDD call processing error; The length of the message and the length field do not match."
If the length of the message is greater than 3552 bits then the setting will be rejected with the error "+XXX FDD call processing error; Message size exceeds maximum length for this message type."
|
|
Setting
|
Range: <length of encoded message in bits>, <"ascii string of hex digits defining SIB">
|
|
Query
|
Same as setting |
|
*RST Setting
|
0, "" |
|
Requirements
|
Lab Application Revision: E.01 and above
|
|
Programming Example
OUTPUT 714;"CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point3:MESSage2 0, """
! Sets the Second SIB15.3 Message to 0, "".
|
CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point4
|
Function
|
Sets/queries the SIB15.4 Message.
This setting can only be changed while SIB15.x Transmission State is Off. If you attempt to change this parameter while SIB15.x Transmission State is On the application will reject the setting with the error "+XXX FDD call processing error; This setting cannot be changed while SIB15.x messages are being transmitted."
If the length of the message in bits rounded up to the next round number of 4 bits does not equal the number of bits in the message itself then the setting will be rejected with the error "+XXX FDD call processing error; The length of the message and the length field do not match."
If the length of the message is greater than 3552 bits then the setting will be rejected with the error "+XXX FDD call processing error; Message size exceeds maximum length for this message type."
|
|
Setting
|
Range: <length of encoded message in bits>, <"ascii string of hex digits defining SIB">
|
|
Query
|
Same as setting |
|
*RST Setting
|
0, "" |
|
Requirements
|
Lab Application Revision: E.01 and above
|
|
Programming Example
OUTPUT 714;"CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point4 0, """
! Sets the SIB15.4 Message to 0, "".
|
CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point5
|
Function
|
Sets/queries the SIB15.5 Message.
This setting can only be changed while SIB15.x Transmission State is Off. If you attempt to change this parameter while SIB15.x Transmission State is On the application will reject the setting with the error "+XXX FDD call processing error; This setting cannot be changed while SIB15.x messages are being transmitted."
If the length of the message in bits rounded up to the next round number of 4 bits does not equal the number of bits in the message itself then the setting will be rejected with the error "+XXX FDD call processing error; The length of the message and the length field do not match."
If the length of the message is greater than 3552 bits then the setting will be rejected with the error "+XXX FDD call processing error; Message size exceeds maximum length for this message type."
|
|
Setting
|
Range: <length of encoded message in bits>, <"ascii string of hex digits defining SIB">
|
|
Query
|
Same as setting |
|
*RST Setting
|
0, "" |
|
Requirements
|
Lab Application Revision: E.01 and above
|
|
Programming Example
OUTPUT 714;"CALL[:CELL]:BCCHannel:SIB15:MESSage:S15Point4 0, """
! Sets the SIB15.5 Message to 0, "".
|
CALL[:CELL]:BCCHannel:SIB15:TRANsmit[:STATe]
|
Function
|
Sets/queries the SIB15.x Transmission State.
This setting controls whether the user supplied SIB15.x messages will be transmitted by the application. Changing this setting (either to On or Off) will not affect any user supplied messages that have been stored by the application.If this setting is "On" and GPS Time Sync State is "On" then the application will update the GPS time parameters in the transmitted SIB15.X messages.This setting has no effect in any Cell Operating Mode other than Active Cell.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
1|0 |
|
*RST Setting
|
0 (off) |
|
Requirements
|
Lab Application Revision: E.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:SIB15:TRANsmit 0"
! Sets the SIB15.x Transmission State to Off.
|
CALL[:CELL]:BCCHannel:SRASearch[:SVALue]
|
Function
|
The setting form of this command performs two functions: (1) sets the
Sintrasearch
value (see
CALL[:CELL]:BCCHannel:SRASearch:VALue
) and (2) sets the
Sintrasearch
state to on (see
CALL[:CELL]:BCCHannel:SRASearch:STATe
).
The query form of this command returns the
Sintrasearch
value.
This setting can only be changed when call status is
Idle
. If
BCCH Update Page
is set to
Auto
and you change this setting while your UE is camped to the test set, the test set performs a
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
. If
BCCH Update Page
is set to
Inhibit
(the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see
BCCH Update Page
for more details).
|
|
Setting
|
Range: -32 dB to 20 dB
Resolution: 2 dB
Sintrasearch can be set to any even number value between -32 dB and +20 dB, but any negative value will be interpreted by the UE as 0 dB.
|
|
Query
|
Same as setting |
|
*RST Setting
|
Value = 0 dB
State = On
|
|
Requirements
|
Lab Application Revision: C.02 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:SRASearch 4"
! Sets Sintrasearch state to on and sets Sintrasearch value to 4 dB.
|
CALL[:CELL]:BCCHannel:SRASearch:STATe
CALL[:CELL]:BCCHannel:SRASearch:VALue
|
Function
|
Sets/queries the
Sintrasearch
value. The
Sintrasearch
value can also be set using the
CALL[:CELL]:BCCHannel:SRASearch[:SVALue]
command.
This parameter can only be set when call status is
Idle
. Changing this setting results in the execution of the
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
if
BCCH Update Page
is set to
Auto
.
|
|
Setting
|
Range: -32 dB to 20 dB
Resolution: 2 dB
Sintrasearch can be set to any even number value between -32 dB and +20 dB, but any negative value will be interpreted by the UE as 0 dB.
|
|
Query
|
Same as setting |
|
*RST Setting
|
0 dB |
|
Requirements
|
Lab Application Revision: C.02 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:SRASearch:VALue 4 DB"
! Sets the Sintrasearch value to 4 dB.
|
CALL[:CELL]:BCCHannel:T300
|
Function
|
Sets/queries the
T300 RRC Conn Req Retransmit Timer
.
This setting can only be changed when call status is
Idle
. If
BCCH Update Page
is set to
Auto
and you change this setting while your UE is camped to the test set, the test set performs a
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
. If
BCCH Update Page
is set to
Inhibit
(the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see
BCCH Update Page
for more details).
|
|
Setting
|
Range: MS100 | MS200 | MS400 | MS600 | MS800 | MS1000 | MS1200 | MS1400 | MS1600 | MS1800 | MS2000 | MS3000 | MS4000 | MS6000 | MS8000
|
|
Query
|
Same as setting |
|
*RST Setting
|
MS400 |
|
Requirements
|
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:T300 MS400"
! Sets the T300 Timer to 400 ms.
|
CALL[:CELL]:BCCHannel:T308
|
Function
|
Sets/queries the
T308 RRC Conn Release Comp Retransmit Timer
.
|
|
Setting
|
Range: MS40 | MS80 | MS160 | MS320
|
|
Query
|
Same as setting |
|
*RST Setting
|
MS40 |
|
Requirements
|
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:T308 MS40"
! Sets the T308 Timer to 40 ms.
|
CALL[:CELL]:BCCHannel:T309
|
Function
|
Sets/queries the
T309 CCO From UTRAN to 2G Connect Timer
.
This setting can only be changed when call status is
Idle
. If
BCCH Update Page
is set to
Auto
and you change this setting while your UE is camped to the test set, the test set performs a
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
. If
BCCH Update Page
is set to
Inhibit
(the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see
BCCH Update Page
for more details).
|
|
Setting
|
Range: 0 to 8 seconds
Resolution: 1 second
|
|
Query
|
Same as setting |
|
*RST Setting
|
8 seconds |
|
Requirements
|
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:T309 8"
! Sets the T309 Timer to 8 seconds.
|
CALL[:CELL]:BCCHannel:T312[:IDLE]
|
Function
|
Sets/queries the
T312 Link Establishment Timer (Idle)
.
This setting can only be changed when call status is
Idle
. If
BCCH Update Page
is set to
Auto
and you change this setting while your UE is camped to the test set, the test set performs a
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
. If
BCCH Update Page
is set to
Inhibit
(the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see
BCCH Update Page
for more details).
|
|
Setting
|
Range: 1 to 15
Resolution: 1
|
|
Query
|
Same as setting |
|
*RST Setting
|
5 |
|
Requirements
|
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:T312 5"
! Sets the T308 Timer to 40 ms.
|
CALL[:CELL]:BCCHannel:T313
|
Function
|
Sets/queries the
T313 Out-Of-Sync Reception Timer
.
This setting can only be changed when call status is
Idle
. If
BCCH Update Page
is set to
Auto
and you change this setting while your UE is camped to the test set, the test set performs a
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
. If
BCCH Update Page
is set to
Inhibit
(the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see
BCCH Update Page
for more details).
|
|
Setting
|
Range: 0 to 15 seconds
Resolution: 1 second
|
|
Query
|
Same as setting |
|
*RST Setting
|
3 seconds |
|
Requirements
|
Test Application Revision: A.06 and above
Lab Application Revision: C.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:T313 15"
! Sets the T313 UE Link Reestablishment Timer to 15 seconds.
|
CALL[:CELL]:BCCHannel:T3212
CALL[:CELL]:BCCHannel:T3312[:VALue]
|
Function
|
Sets/queries the
T3312 Periodic RA Update Timer
.
To set the units for this timer, see
CALL[:CELL]:BCCHannel:T3312:UNITs
.
|
|
Setting
|
Range: 0 to 31
Resolution: 1
|
|
Query
|
Same as setting |
|
*RST Setting
|
10 |
|
Requirements
|
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:T3312 10"
! Sets T3312 Timer to 10.
|
CALL[:CELL]:BCCHannel:T3312:UNITs
|
Function
|
Sets/queries the
T3312 Periodic RA Update Units
.
To set the value for this timer, see
CALL[:CELL]:BCCHannel:T3312[:VALue]
.
|
|
Setting
|
Range: SEC2 | MINutes | DHOurs | DEACtivated
|
|
Query
|
Range: SEC2 | MIN | DHO | DEAC |
|
*RST Setting
|
DEAC |
|
Requirements
|
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:T3312:UNITs DEAC"
! Sets T3312 timer's units to DEACtivated.
|
CALL[:CELL]:BCCHannel:UPDAtepage
|
Function
|
Sets/queries the BCCH Update Page state (see
BCCH Update Page
and
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
).
|
|
Setting
|
Range: AUTO|INHibit
|
|
Query
|
Range: AUTO|INH
|
|
*RST Setting
|
INH |
|
Requirements
|
Test Application Revision: A.04 and above
Lab Application Revision: A.02 and above
|
|
Programming Example
OUTPUT 714;"CALL:BCCHannel:UPDAtepage AUTO"
! Instructs the test set to send a Paging Type 1 message