CALL:CCPChannel:PRIMary[:SLEVel]
|
Function
|
Sets/queries the initial power offset of the primary common control physical channel. This command sets the power offset level and turns on the power offset.
This setting cannot be changed while in active cell operating mode. Attempting to change this setting while in this mode results in the following error message: "Command Rejected. Change Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this value.
|
|
Setting
|
Range: -20.00 dB to 0 dB
Resolution: 0.01
|
|
Query
|
Range: -20.00 dB to 0 dB
Resolution: 0.01
|
|
*RST Setting
|
-5.3 dB |
|
Requirements |
Test Application Revision: A.02 and above.
Lab Application Revision: A.01 and above
Test Application Revision A.06 changed *RST Setting to -5.3 dB.
Lab Application Revision C.01 changed *RST Setting to -5.3 dB.
|
|
Programming Example
OUTPUT 714;"CALL:CCPCHANNEL:PRIMARY:SLEVEL -15DB" !Enables and sets the initial P-CCPCH power offset to -15 dB.
|
CALL:CCPChannel:PRIMary:LEVel
|
Function
|
Sets/queries the primary common control physical channel's initial power offset.
This setting cannot be changed while in active cell operating mode. Attempting to change this setting while in this mode results in the following error message: "Command Rejected. Change Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this setting.
|
|
Setting
|
Range: -20.00 dB to 0 dB
Resolution: 0.01
|
|
Query
|
Range: -20.00 dB to 0 dB
Resolution: 0.01
|
|
*RST Setting
|
-5.3 dB |
|
Requirements |
Test Application Revision: A.02 and above.
Lab Application Revision: A.01 and above.
Test Application Revision A.06 changed *RST Setting to -5.3 dB.
Lab Application Revision C.01 changed *RST Setting to -5.3 dB.
|
|
Programming Example
OUTPUT 714;"CALL:CCPCHANNEL:PRIMARY:LEVEL -15DB" !Sets the initial P-CCPCH power offset to -15 dB.
|
CALL:CCPChannel:PRIMary:STATe
|
Function
|
Sets/queries the primary common control physical channel's state.
This setting cannot be changed while in active cell operating mode. Attempting to change this setting while in this mode results in the following error message: "Command Rejected. Change Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this setting.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements |
Test Application Revision: A.02 and above.
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:CCPCHANNEL:PRIMARY:STATE ON"
|
CALL:CCPChannel:SECondary[:SLEVel]
|
Function
|
Sets/queries the initial power offset of the secondary common control physical channel. This command sets the power offset level and turns on the power offset.
This setting cannot be changed while in active cell operating mode. Attempting to change this setting while in this mode results in the following error message: "Command Rejected. Change Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this setting.
|
|
Setting
|
Range: -20.00 dB to 0 dB
Resolution: 0.01
|
|
Query
|
Same as setting. |
|
*RST Setting
|
-10.3 dB |
|
Requirements |
Test Application Revision: A.02 and above.
Lab Application Revision: A.01 and above.
Test Application Revision A.06 changed *RST Setting to -10.3 dB.
Lab Application Revision C.01 changed *RST Setting to -10.3 dB.
|
|
Programming Example
OUTPUT 714;"CALL:CCPCHANNEL:SECONDARY:SLEVEL -10DB" !Sets P-CCPCH initial power offset to -10 dB.
|
CALL:CCPChannel:SECondary:CCODe
|
Function
|
THIS COMMAND IS OBSOLETE. Please use
CALL:CCPChannel:SECondary:CCODe:CODE
.
Sets/queries the secondary common control physical channel's channelization code.
|
|
Setting
|
Range: CODE6|CODE7|CODE9|CODE16|CODE17|CODE26|CODE57
|
|
Query
|
Range: CODE6|CODE7|CODE9|CODE16|CODE17|CODE26|CODE57
|
|
*RST Setting
|
CODE7 |
|
Requirements |
Test Application Revision: A.02 and above.
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:CCPCHANNEL:SECONDARY:CCODE CODE6"
! Sets the S-CCPCH channelization code to 6.
|
CALL:CCPChannel:SECondary:CCODe:CODE
|
Function
|
Sets/queries the secondary common control physical channel's channelization code. Code 0 is reserved for the CPICH.
This setting cannot be changed while in active cell operating mode. Attempting to change this setting while in this mode results in the following error message: "Command Rejected While in Active Cell Mode." Use the cell off operating mode when changing this value.
|
|
Setting
|
Range: 1 to 63
Resolution: 1
|
|
Query
|
Range: 1 to 63
Resolution: 1
|
|
*RST Setting
|
7 |
|
Requirements
|
Lab Application Revision: F.00 and above
Test Application Revision: A.14 and above
|
|
Programming Example
OUTPUT 714;"CALL:CCPChannel:SECondary:CCODe:CODE 7"
|
CALL:CCPChannel:SECondary:CONFigure
|
Function
|
Sets/queries
SCCPCH/PRACH Configuration
.
|
|
Setting
|
Range: SIGNaling|STRaffic
|
|
Query
|
Range: SIGN|STR
|
|
*RST Setting
|
SIGNaling |
|
Requirements |
Lab Application Revision: F.00 and above
|
|
Programming Example
OUTPUT 714;"CALL:CCPChannel:SECondary:CONFigure SIGNaling"
! Sets the SCCPCH/PRACH Configuration to Signaling only.
|
CALL:CCPChannel:SECondary:CONNected:CONFig:STATe
|
Function
|
Sets/queries the Connected S-CCPH Channel Configuration State.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements |
Lab Application Revision: F.00 and above
Test Application Revision: A.14 and above
|
|
Programming Example
OUTPUT 714;"CALL:CCPChannel:SECondary:CONNected:CONFig:STATe" !Enables the Connected S-CCPH Channel Configuration.
|
CALL:CCPChannel:SECondary:LEVel
|
Function
|
Sets/queries the secondary common control physical channel's initial power offset.
This setting cannot be changed while in active cell operating mode. Attempting to change this setting while in this mode results in the following error message: "Command Rejected. Change Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this setting.
|
|
Setting
|
Range: -20.00 dB to 0 dB
Resolution: 0.01
|
|
Query
|
Range: -20.00 dB to 0 dB
Resolution: 0.01
|
|
*RST Setting
|
-10.3 dB |
|
Requirements |
Test Application Revision: A.02 and above.
Lab Application Revision: A.01 and above.
Test Application Revision A.06 changed *RST Setting to -10.3 dB.
Lab Application Revision C.01 changed *RST Setting to -10.3 dB.
|
|
Programming Example
OUTPUT 714;"CALL:CCPCHANNEL:SECONDARY:LEVEL -5" !Sets the intial common control physical channel level to -5 dB.
|
CALL:CCPChannel:SECondary:STATe
|
Function
|
Sets/queries the secondary common control physical channel's state.
This setting cannot be changed while in active cell operating mode. Attempting to change this setting while in this mode results in the following error message: "Command Rejected. Change Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this setting.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements |
Test Application Revision: A.02 and above.
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:CCPCHANNEL:SECONDARY:STATE ON" !Enables the secondary common control physical channel.
|
|