CALL:COMPressed
Last updated: March 16, 2009
This section is only applicable to the lab application.
GPIB Command Conventions
CALL:COMPressed:ENABle
|
Function
|
Enables/disables compressed mode (see
Enabling/Disabling Compressed Mode
).
To query the current status of compressed mode, use the
CALL:STATus:COMPressed:STATe?
query.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
*RST Setting
|
0 |
|
Requirements |
Lab Application Revision: B.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:ENABle ON"
! Enables compressed mode.
|
CALL:COMPressed:HSDPa:TRANsmission:MODE
|
Function
|
Sets/queries the
HSDPA Downlink Transmission Mode
.
This parameter can only be changed when compressed mode is not active.
|
|
Setting
|
Range: TGSKip|TGNSkip
|
|
*RST Setting
|
TGNSkip |
|
Requirements |
Lab Application Revision: F.00 and above
|
|
Programming Example
OUTPUT 714;"CCALL:COMPressed:HSDPa:TRANsmission:MODE TGNSkip"
! Sets HSDPA Downlink Transmission Mode not to skip transmission gap.
|
CALL:COMPressed:HSUPa:TRANsmission:MODE:MS2
|
Function
|
Sets/queries the
HSUPA Downlink Transmission Mode (2ms TTI)
.
This parameter can only be changed when compressed mode is not active.
|
|
Setting
|
Range: TGSKip|TGNSkip
|
|
*RST Setting
|
TGSKip |
|
Requirements |
Lab Application Revision: F.00 and above
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:HSUPa:TRANsmission:MODE:MS2 TGSKip"
! Sets HSUPA 2ms TTI Downlink Transmission Mode to skip transmission gap.
|
CALL:COMPressed:MEASurement:CONFig
|
Function
|
Sets/queries
Measurement Configuration
.
This parameter can only be changed when compressed mode is not active.
|
|
Setting
|
Range: ITRFreq|ITRRat
|
|
*RST Setting
|
ITRR |
|
Requirements |
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:MEASurement:CONFig ITRFreq"
! Sets Measurement Configuration to InterfrequencyMeas.
|
CALL:COMPressed:MEASurement:GSMSystem:BSIC:VERification
|
Function
|
Sets/queries
GSM Meas BSIC Verification
.
This parameter can only be changed when compressed mode is not active.
|
|
Setting
|
Range: VERified|NVERified
|
|
*RST Setting
|
NVER |
|
Requirements |
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:MEASurement:GSMSystem:BSIC:VERification VERified"
! Sets GSM Meas BSIC Verification to verifiedBSIC.
|
CALL:COMPressed:MEASurement:GSMSystem:NIABort
|
Function
|
Sets/queries
GSM Meas N_Identify_Abort
.
This parameter can only be changed when compressed mode is not active.
|
|
Setting
|
Range: 1 to 128
|
|
*RST Setting
|
128 |
|
Requirements |
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:MEASurement:GSMSystem:NIABort 100"
! Sets GSM Meas N_Identify_Abort to 100 attempts.
|
CALL:COMPressed:MEASurement:GSMSystem:TRCabort
|
Function
|
Sets/queries
GSM Meas T_Re_Confirm_Abort (x0.5 seconds)
.
This parameter can only be changed when compressed mode is not active.
|
|
Setting
|
Range: 1 to 20 (0.5 s to 10 s)
|
|
*RST Setting
|
20 (10 s) |
|
Requirements |
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:MEASurement:GSMSystem:TRCabort 10"
! Sets GSM Meas T_Re_Confirm_Abort (x0.5 seconds) to 5 seconds.
|
CALL:COMPressed:MEASurement:GSMSystem:RSSI:RINTerval
|
Function
|
Sets/queries the
GSM RSSI Measurement Reporting Interval
.
|
|
Setting
|
Range: RIQuarter|RIHalf|RI1|RI2|RI3|RI4|RI6|RI8|RI12|RI16
|RI20|RI24|RI28|RI32|RI64
(RIQuarter = 0.25 s, RIHalf = 0.5 s, RI1 = 1 s etc.)
|
|
Query
|
Range: RIQ|RIH|RI1|RI2|RI3|RI4|RI6|RI8|RI12|RI16
|RI20|RI24|RI28|RI32|RI64
|
|
*RST Setting
|
RI2 |
|
Requirements |
Lab Application Revision: B.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:MEASurement:GSMSystem:RSSI:RINTerval RI4"
! Sets the GSM RSSI measurement reporting interval to 4 seconds.
|
CALL:COMPressed:MEASurement:GSMSystem:RSSI:RQUantity
|
Function
|
Sets/queries
GSM RSSI Measurement Reporting Quantity
.
|
|
Setting
|
Range: RQ1|RQ2|RQ4|RQ8|RQ16|RQ32|RQ64|RQINfinity
(RQ1 = 1 report, RQ2 = 2 reports, RQINfinity = infinite number of reports, etc.)
|
|
Query
|
Range: RQ1|RQ2|RQ4|RQ8|RQ16|RQ32|RQ64|RQIN
|
|
*RST Setting
|
RQIN |
|
Requirements |
Lab Application Revision: B.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:MEASurement:GSMSystem:RSSI:RQUantity RQ1"
! Sets the number of reports to 1.
|
CALL:COMPressed:MEASurement:ITRFrequency:RINTerval
|
Function
|
Sets/queries the
Interfreq Measurement Reporting Interval
.
|
|
Setting
|
Range: RIQuarter|RIHalf|RI1|RI2|RI3|RI4|RI6|RI8|RI12|RI16
|RI20|RI24|RI28|RI32|RI64
(RIQuarter = 0.25 s, RIHalf = 0.5 s, RI1 = 1 s etc.)
|
|
Query
|
Range: RIQ|RIH|RI1|RI2|RI3|RI4|RI6|RI8|RI12|RI16
|RI20|RI24|RI28|RI32|RI64
|
|
*RST Setting
|
RI2 |
|
Requirements |
Lab Application Revision: B.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:MEASurement:ITRFrequency:RINTerval RI4"
! Sets the interfreq measurement reporting interval to 4 seconds.
|
CALL:COMPressed:MEASurement:ITRFrequency:RQUantity
|
Function
|
Sets/queries
Interfreq Measurement Reporting Quantity
.
|
|
Setting
|
Range: RQ1|RQ2|RQ4|RQ8|RQ16|RQ32|RQ64|RQINfinity
(RQ1 = 1 report, RQ2 = 2 reports, RQINfinity = infinite number of reports, etc.)
|
|
Query
|
Range: RQ1|RQ2|RQ4|RQ8|RQ16|RQ32|RQ64|RQIN
|
|
*RST Setting
|
RQIN |
|
Requirements |
Lab Application Revision: B.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:MEASurement:ITRFrequency:RQUantity RQ1"
! Sets the number of reports to 1.
|
CALL:COMPressed:MEASurement:STATe
|
Function
|
Sets/queries
UE Measurements in Compressed Mode
.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 |
|
Requirements |
Lab Application Revision: B.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:MEASurement:STATe ON"
! Sets the UE measurements in compressed mode state to on.
|
CALL:COMPressed:MEASurement:TYPe
|
Function
|
This command is obsolete. Please use
CALL:COMPressed:TGPSequence:ALL:TGMPurpose
or
CALL:COMPressed:TGPSequence([1]|2|3|4):TGMPurpose
.
Sets/queries
Compressed Mode Measurement Purpose
for TGPS 1.
|
|
Setting
|
Range: FDDMeas|GBR|GIBI|GSMRssi
|
|
Query
|
Same as setting. |
|
*RST Setting
|
GSMR |
|
Requirements |
Lab Application Revision: B.01 and above
Lab Application Revision D.00.04, added GBR and GIBI
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:MEASurement:TYPe FDDMeas"
! Sets the compressed mode measurement purpose to FDD Meas.
|
CALL:COMPressed:PCReconfig:CFNHandling
|
Function
|
Sets/queries
CM PCR Timing Indication (CFN Handling)
.
|
|
Setting
|
Range: INITialise|MAINtain
|
|
Query
|
Range: INIT|MAIN
|
|
*RST Setting
|
MAIN |
|
Requirements |
Lab Application Revision: C.02 and above
Lab Application Revision D.02, changed default to MAIN.
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:PCReconfig:CFNHandling MAINtain"
! Sets CM PCR Timing Indication (CFN Handling) to Maintain.
|
CALL:COMPressed:TGPSequence:ALL:STATe
|
Function
|
Sets/queries
<num> TGPS State
for the first through fourth TGPSs (the first num value sets
First TGPS State
, the second num value sets
Second TGPS State
, etc.). You can set
TGPS State
for an individual TGPS using the
CALL:COMPressed:TGPSequence([1]|2|3|4):STATe
commands.
If
TGPS Definition During Call Setup
is set to
Off
, this parameter can only be changed when compressed mode is not active. If
TGPS Definition During Call Setup
is set to
RB Setup
, this parameter can only be changed when the connection status is idle.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1,0,0,0 |
|
Requirements |
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:TGPSequence:ALL:STATe 1,1,1,0"
! Sets the first through third TGPS states to on, the fourth TGPS state to off.
|
CALL:COMPressed:TGPSequence:ALL:TGCFn:RELative
|
Function
|
Sets/queries
<num> TG Relative CFN (TGCFN)
for the first through fourth TGPSs (the first num value sets
First TG Relative CFN (TGCFN)
, the second num value sets
Second TG Relative CFN (TGCFN)
, etc.). You can set
TG Relative CFN (TGCFN)
for an individual TGPS using the
CALL:COMPressed:TGPSequence([1]|2|3|4):TGCFn:RELative
commands.
If
TGPS Definition During Call Setup
is set to
Off
, this parameter can only be changed when compressed mode is not active. If
TGPS Definition During Call Setup
is set to
RB Setup
, this parameter can only be changed when the connection status is idle.
The TGPSs must be offset so that there is never more than one transmission gap per frame.
|
|
Setting
|
Range: 0 to 255 frames
Resolution: 1 frame
|
|
Query
|
Same as setting |
|
*RST Setting
|
0,2,6,14 |
|
Requirements |
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:TGPSequence:ALL:TGCFn:RELative 0,4,12,28"
! Sets the first through fourth TG Relative CFN (TGCFN) values
! to 0, 4, 12 and 28, respectively.
|
CALL:COMPressed:TGPSequence:ALL:TGDistance
|
Function
|
Sets/queries
<num> TG Start Distance (TGD)
for the first through fourth TGPSs (the first num value sets
First TG Start Distance
, the second num value sets
Second TG Start Distance
, etc.). You can set
TG Start Distance
for an individual TGPS using the
CALL:COMPressed:TGPSequence([1]|2|3|4):TGDistance
commands.
If
TGPS Definition During Call Setup
is set to
Off
, this parameter can only be changed when compressed mode is not active. If
TGPS Definition During Call Setup
is set to
RB Setup
, this parameter can only be changed when the connection status is idle.
This setting is only applicable when TGL2 is non-zero. Note, you cannot place TGL1 and TGL2 within the same frame.
|
|
Setting
|
Range: 15 to 269 slots, 270 (undefined)
Resolution: 1 slot
|
|
Query
|
Same as setting |
|
*RST Setting
|
270,270,270,270 |
|
Requirements |
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:TGPSequence:ALL:TGDistance 30,45,60,270"
! Sets the first through fourth TG Start Distance (TGD) values to 30, 45, 60 slots
! and Undefined, respectively.
|
CALL:COMPressed:TGPSequence:ALL:TGLength[1]
|
Function
|
Sets/queries
<num> Transmission Gap Length 1 (TGL1)
for the first through fourth TGPSs (the first num value sets
First Transmission Gap Length 1 (TGL1)
, the second num value sets
Second Transmission Gap Length 1 (TGL1)
, etc.). You can set
Transmission Gap Length 1 (TGL1)
for an individual TGPS using the
CALL:COMPressed:TGPSequence([1]|2|3|4):TGLength[1]
commands.
If
TGPS Definition During Call Setup
is set to
Off
, this parameter can only be changed when compressed mode is not active. If
TGPS Definition During Call Setup
is set to
RB Setup
, this parameter can only be changed when the connection status is idle.
There cannot be more than 7 transmission gap slots within one frame.
|
|
Setting
|
Range: 1 to 14 slots
Resolution: 1 slot
|
|
Query
|
Same as setting |
|
*RST Setting
|
7,7,7,7 |
|
Requirements |
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:TGPSequence:ALL:TGLength 7,3,7,5"
! Sets the first through fourth Transmission Gap Length 1 (TGL1) values to
! 7, 3, 7, and 5 slots, respectively.
|
CALL:COMPressed:TGPSequence:ALL:TGLength2
|
Function
|
Sets/queries
<num> Transmission Gap Length 2 (TGL2)
for the first through fourth TGPSs (the first num value sets
First Transmission Gap Length 2 (TGL2)
, the second num value sets
Second Transmission Gap Length 2 (TGL2)
, etc.). You can set
Transmission Gap Length 2 (TGL2)
for an individual TGPS using the
CALL:COMPressed:TGPSequence([1]|2|3|4):TGLength2
commands.
If
TGPS Definition During Call Setup
is set to
Off
, this parameter can only be changed when compressed mode is not active. If
TGPS Definition During Call Setup
is set to
RB Setup
, this parameter can only be changed when the connection status is idle.
There cannot be more than 7 transmission gap slots within one frame. Also, if TGL2 is non-zero, you must specify a valid TGD.
|
|
Setting
|
Range: 0 to 14 slots
Resolution: 1 slot
|
|
Query
|
Same as setting |
|
*RST Setting
|
0,0,0,0 |
|
Requirements |
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:TGPSequence:ALL:TGLength2 7,3,7,5"
! Sets the first through fourth Transmission Gap Length 2 (TGL2) values to
! 7, 3, 7, and 5 slots, respectively.
|
CALL:COMPressed:TGPSequence:ALL:TGMPurpose
|
Function
|
Sets/queries
<num> TG Measurement Purpose (TGMP)
for the first through fourth TGPSs (the first num value sets
First TG Measurement Purpose (TGMP)
, the second num value sets
Second TG Measurement Purpose (TGMP)
, etc.). You can set
TG Measurement Purpose (TGMP)
for an individual TGPS using the
CALL:COMPressed:TGPSequence([1]|2|3|4):TGMPurpose
commands.
If
TGPS Definition During Call Setup
is set to
Off
, this parameter can only be changed when compressed mode is not active. If
TGPS Definition During Call Setup
is set to
RB Setup
, this parameter can only be changed when the connection status is idle.
|
|
Setting
|
Range: FDDMeas|GSMRssi|GIBI|GBR
|
|
Query
|
Same as setting. |
|
*RST Setting
|
GSMR, GIBI, GBR, FDDM |
|
Requirements |
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:TGPSequence:ALL:TGMPurpose GSMR, GSMR, GIBI, GBR"
! Sets the first through fourth TG Measurement Purpose (TGMP) values to
! GSM RSSI, GSM RSSI, GSM Initial BSIC ID, and GSM BSIC Reconfirmation, respectively.
|
CALL:COMPressed:TGPSequence:ALL:TGPLength
|
Function
|
Sets/queries
<num> TG Pattern Length (TGPL)
for the first through fourth TGPSs (the first num value sets
First TG Pattern Length (TGPL)
, the second num value sets
Second TG Pattern Length (TGPL)
, etc.). You can set
TG Pattern Length (TGPL)
for an individual TGPS using the
CALL:COMPressed:TGPSequence([1]|2|3|4):TGPLength
commands.
If
TGPS Definition During Call Setup
is set to
Off
, this parameter can only be changed when compressed mode is not active. If
TGPS Definition During Call Setup
is set to
RB Setup
, this parameter can only be changed when the connection status is idle.
TGPL must be long enough to encompass all of TGL1 and TGL2.
|
|
Setting
|
Range: 1 to 144 frames
Resolution: 1 frame
|
|
Query
|
Same as setting |
|
*RST Setting
|
4, 8, 16, 16 |
|
Requirements |
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:TGPSequence:ALL:TGPLength 4,8,32,32"
! Sets the first through fourth TG Pattern Length (TGPL) values to
! 4, 8, 32, and 32 frames, respectively.
|
CALL:COMPressed:TGPSequence:ALL:TGPRc
|
Function
|
Sets/queries
<num> TG Pattern Repetition Count (TGPRC)
for the first through fourth TGPSs (the first num value sets
First TG Pattern Repetition Count (TGPRC)
, the second num value sets
Second TG Pattern Repetition Count (TGPRC)
, etc.). You can set
TG Pattern Repetition Count (TGPRC)
for an individual TGPS using the
CALL:COMPressed:TGPSequence([1]|2|3|4):TGPRc
commands.
If
TGPS Definition During Call Setup
is set to
Off
, this parameter can only be changed when compressed mode is not active. If
TGPS Definition During Call Setup
is set to
RB Setup
, this parameter can only be changed when the connection status is idle.
|
|
Setting
|
Range: 0 to 511 (0 = infinity)
|
|
Query
|
Same as setting |
|
*RST Setting
|
0, 0, 0, 0 |
|
Requirements |
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:TGPSequence:ALL:TGPRc 20,0,0,0"
! Sets the first TG Pattern Repetition Count (TGPRC) to
! 20 repetitions, and the second through fourth TG Pattern
! Repetition Count (TGPRC) values to infinite repetitions.
|
CALL:COMPressed:TGPSequence:ALL:TGSNumber
|
Function
|
Sets/queries
<num> TG Starting Slot Number (TGSN)
for the first through fourth TGPSs (the first num value sets
First TG Starting Slot Number (TGSN)
, the second num value sets
Second TG Starting Slot Number (TGSN)
, etc.). You can set
TG Starting Slot Number (TGSN)
for an individual TGPS using the
CALL:COMPressed:TGPSequence([1]|2|3|4):TGSNumber
commands.
If
TGPS Definition During Call Setup
is set to
Off
, this parameter can only be changed when compressed mode is not active. If
TGPS Definition During Call Setup
is set to
RB Setup
, this parameter can only be changed when the connection status is idle.
|
|
Setting
|
Range: 0 to 14 (slot 0 to slot 14)
Resolution: 1
|
|
Query
|
Same as setting |
|
*RST Setting
|
11, 11, 11, 11 |
|
Requirements |
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:TGPSequence:ALL:TGSNumber 0, 0, 11, 11"
! Sets the first through fourth TG Starting Slot Number (TGSN) values to
! slot 0, slot 0, slot 11, and slot 11, respectively.
|
CALL:COMPressed:TGPSequence:DEFinition
|
Function
|
Sets/queries
TGPS Definition During Call Setup
. This parameter can only be set when the connection status is idle.
|
|
Setting
|
Range: RBSetup|OFF
|
|
Query
|
Same as setting |
|
*RST Setting
|
OFF |
|
Requirements |
Lab Application Revision: B.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:TGPSequence:DEFinition RBSetup"
! Sets TGPS definition during call setup to RB Setup.
|
CALL:COMPressed:TGPSequence:DFSType
|
Function
|
Sets/queries
Downlink Frame Structure Type
. If
TGPS Definition During Call Setup
is set to
Off
, this parameter can only be changed when compressed mode is not active. If
TGPS Definition During Call Setup
is set to
RB Setup
, this parameter can only be changed when the connection status is idle.
|
|
Setting
|
Range: ATYPe|BTYPe
|
|
Query
|
Same as setting |
|
*RST Setting
|
ATYP |
|
Requirements |
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:TGPSequence:DFSType BTYPe"
! Sets Downlink Frame Structure Type to type B.
|
CALL:COMPressed:TGPSequence([1]|2|3|4):STATe
|
Function
|
Sets/queries
<num> TGPS State
for the first, second, third or fourth TGPS (sending :TGPSequence or :TGPSequence1 sets
First TGPS State
, sending :TGPSequence2 sets
Second TGPS State
, etc.). You can set
TGPS State
for all four TGPSs using the
CALL:COMPressed:TGPSequence:ALL:STATe
command.
If
TGPS Definition During Call Setup
is set to
Off
, this parameter can only be changed when compressed mode is not active. If
TGPS Definition During Call Setup
is set to
RB Setup
, this parameter can only be changed when the connection status is idle.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
-
First TGPS: 1
-
Second TGPS: 0
-
Third TGPS: 0
-
Fourth TGPS: 0
|
|
Requirements
|
Lab Application Revision: D.00.04 and above. |
|
Programming Example
OUTPUT 714;"CALL:COMPressed:TGPSequence4:STATe On"
! Sets Fourth TGPS State to On.
|
CALL:COMPressed:TGPSequence([1]|2|3|4):TGCFn:RELative
|
Function
|
Sets/queries
<num> TG Relative CFN (TGCFN)
for the first, second, third or fourth TGPS (sending :TGPSequence or :TGPSequence1 sets
First TG Relative CFN (TGCFN)
, sending :TGPSequence2 sets
Second TG Relative CFN (TGCFN)
, etc.). You can set
TG Relative CFN (TGCFN)
for all four TGPSs using the
CALL:COMPressed:TGPSequence:ALL:TGCFn:RELative
command.
If
TGPS Definition During Call Setup
is set to
Off
, this parameter can only be changed when compressed mode is not active. If
TGPS Definition During Call Setup
is set to
RB Setup
, this parameter can only be changed when the connection status is idle.
The TGPSs must be offset so that there is never more than one transmission gap per frame.
|
|
Setting
|
Range: 0 to 255 frames
Resolution: 1 frame
|
|
Query
|
Same as setting |
|
*RST Setting
|
-
First TGPS: 0
-
Second TGPS: 2
-
Third TGPS: 6
-
Fourth TGPS: 14
|
|
Requirements
|
Lab Application Revision: D.00.04 and above. |
|
Programming Example
OUTPUT 714;"CALL:COMPressed:TGPSequence4:TGCFn:RELative 12"
! Sets Fourth TG Relative CFN (TGCFN) to 12.
|
CALL:COMPressed:TGPSequence([1]|2|3|4):TGDistance
|
Function
|
Sets/queries
<num> TG Start Distance (TGD)
for the first, second, third or fourth TGPS (sending :TGPSequence or :TGPSequence1 sets
First TG Start Distance (TGD)
, sending :TGPSequence2 sets
Second TG Start Distance (TGD)
, etc.). You can set
TG Start Distance (TGD)
for all four TGPSs using the
CALL:COMPressed:TGPSequence:ALL:TGDistance
command.
If
TGPS Definition During Call Setup
is set to
Off
, this parameter can only be changed when compressed mode is not active. If
TGPS Definition During Call Setup
is set to
RB Setup
, this parameter can only be changed when the connection status is idle.
This setting is only applicable when TGL2 is non-zero. Note, you cannot place TGL1 and TGL2 within the same frame.
|
|
Setting
|
Range: 15 to 269 slots, 270 (undefined)
Resolution: 1 slot
|
|
Query
|
Same as setting |
|
*RST Setting
|
-
First TGPS: 270
-
Second TGPS: 270
-
Third TGPS: 270
-
Fourth TGPS: 270
|
|
Requirements
|
Lab Application Revision: D.00.04 and above. |
|
Programming Example
OUTPUT 714;"CALL:COMPressed:TGPSequence3:TGDistance 60"
! Sets Third TG Start Distance (TGD) to 60 slots.
|
CALL:COMPressed:TGPSequence([1]|2|3|4):TGLength[1]
|
Function
|
Sets/queries
<num> Transmission Gap Length 1 (TGL1)
for the first, second, third or fourth TGPS (sending :TGPSequence or :TGPSequence1 sets
First Transmission Gap Length 1 (TGL1)
, sending :TGPSequence2 sets
Second Transmission Gap Length 1 (TGL1)
, etc.). You can set
Transmission Gap Length 1 (TGL1)
for all four TGPSs using the
CALL:COMPressed:TGPSequence:ALL:TGLength[1]
command.
If
TGPS Definition During Call Setup
is set to
Off
, this parameter can only be changed when compressed mode is not active. If
TGPS Definition During Call Setup
is set to
RB Setup
, this parameter can only be changed when the connection status is idle.
There cannot be more than 7 transmission gap slots within one frame.
|
|
Setting
|
Range: 1 to 14 slots
Resolution: 1 slot
|
|
Query
|
Same as setting |
|
*RST Setting
|
-
First TGPS: 7
-
Second TGPS: 7
-
Third TGPS: 7
-
Fourth TGPS: 7
|
|
Requirements |
Lab Application Revision: B.01 and above
Lab Application Revision D.00.04, added ([1]|2|3|4) and [1]
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:TGPSequence4:TGLength 5"
! Sets Fourth Transmission Gap Length 1 (TGL1) to 5 slots.
|
CALL:COMPressed:TGPSequence([1]|2|3|4):TGLength2
|
Function
|
Sets/queries
<num> Transmission Gap Length 2 (TGL2)
for the first, second, third or fourth TGPS (sending :TGPSequence or :TGPSequence1 sets
First Transmission Gap Length 2 (TGL2)
, sending :TGPSequence2 sets
Second Transmission Gap Length 2 (TGL2)
, etc.). You can set
Transmission Gap Length 2 (TGL2)
for all four TGPSs using the
CALL:COMPressed:TGPSequence:ALL:TGLength2
command.
If
TGPS Definition During Call Setup
is set to
Off
, this parameter can only be changed when compressed mode is not active. If
TGPS Definition During Call Setup
is set to
RB Setup
, this parameter can only be changed when the connection status is idle.
There cannot be more than 7 transmission gap slots within one frame. Also, if TGL2 is non-zero, you must specify a valid TGD.
|
|
Setting
|
Range: 0 to 14 slots
Resolution: 1 slot
|
|
Query
|
Same as setting |
|
*RST Setting
|
-
First TGPS: 0
-
Second TGPS: 0
-
Third TGPS: 0
-
Fourth TGPS: 0
|
|
Requirements |
Lab Application Revision: D.00.04 and above |
|
Programming Example
OUTPUT 714;"CALL:COMPressed:TGPSequence4:TGLength2 5"
! Sets Fourth Transmission Gap Length 2 (TGL2) to 5 slots.
|
CALL:COMPressed:TGPSequence([1]|2|3|4):TGMPurpose
|
Function
|
Sets/queries
<num> TG Measurement Purpose (TGMP)
for the first, second, third or fourth TGPS (sending :TGPSequence or :TGPSequence1 sets
First TG Measurement Purpose (TGMP)
, sending :TGPSequence2 sets
Second TG Measurement Purpose (TGMP)
, etc.). You can set
TG Measurement Purpose (TGMP)
for all four TGPSs using the
CALL:COMPressed:TGPSequence:ALL:TGMPurpose
command.
If
TGPS Definition During Call Setup
is set to
Off
, this parameter can only be changed when compressed mode is not active. If
TGPS Definition During Call Setup
is set to
RB Setup
, this parameter can only be changed when the connection status is idle.
|
|
Setting
|
Range: FDDMeas|GSMRssi|GIBI|GBR
|
|
Query
|
Same as setting |
|
*RST Setting
|
-
First TGPS: GSMR
-
Second TGPS: GIBI
-
Third TGPS: GBR
-
Fourth TGPS: FDDM
|
|
Requirements |
Lab Application Revision: D.00.04 and above |
|
Programming Example
OUTPUT 714;"CALL:COMPressed:TGPSequence4:TGMPurpose GBR"
! Sets Fourth TG Measurement Purpose (TGMP) to GSM BSIC Reconfirmation.
|
CALL:COMPressed:TGPSequence([1]|2|3|4):TGPLength
|
Function
|
Sets/queries
<num> TG Pattern Length (TGPL)
for the first, second, third or fourth TGPS (sending :TGPSequence or :TGPSequence1 sets
First TG Pattern Length (TGPL)
, sending :TGPSequence2 sets
Second TG Pattern Length (TGPL)
, etc.). You can set
TG Pattern Length (TGPL)
for all four TGPSs using the
CALL:COMPressed:TGPSequence:ALL:TGPLength
command.
If
TGPS Definition During Call Setup
is set to
Off
, this parameter can only be changed when compressed mode is not active. If
TGPS Definition During Call Setup
is set to
RB Setup
, this parameter can only be changed when the connection status is idle.
TGPL must be long enough to encompass all of TGL1 and TGL2.
|
|
Setting
|
Range: 1 to 144 frames
Resolution: 1 frame
|
|
Query
|
Same as setting |
|
*RST Setting
|
-
First TGPS: 4 frames
-
Second TGPS: 8 frames
-
Third TGPS: 16 frames
-
Fourth TGPS: 16 frames
|
|
Requirements |
Lab Application Revision: B.01 and above
Lab Application Revision D.00.04, added ([1]|2|3|4)
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:TGPSequence:TGPLength 6"
! Sets First TG Pattern Length (TGPL) to 6 frames.
|
CALL:COMPressed:TGPSequence([1]|2|3|4):TGPRc
|
Function
|
Sets/queries
<num> TG Pattern Repetition Count (TGPRC)
for the first, second, third or fourth TGPS (sending :TGPSequence or :TGPSequence1 sets
First TG Pattern Repetition Count (TGPRC)
, sending :TGPSequence2 sets
Second TG Pattern Repetition Count (TGPRC)
, etc.). You can set
TG Pattern Repetition Count (TGPRC)
for all four TGPSs using the
CALL:COMPressed:TGPSequence:ALL:TGPRc
command.
If
TGPS Definition During Call Setup
is set to
Off
, this parameter can only be changed when compressed mode is not active. If
TGPS Definition During Call Setup
is set to
RB Setup
, this parameter can only be changed when the connection status is idle.
|
|
Setting
|
Range: 0 to 511 (0 = infinity)
|
|
Query
|
Same as setting |
|
*RST Setting
|
-
First TGPS: 0
-
Second TGPS: 0
-
Third TGPS: 0
-
Fourth TGPS: 0
|
|
Requirements |
Lab Application Revision: D.00.04 and above |
|
Programming Example
OUTPUT 714;"CALL:COMPressed:TGPSequence4:TGPRc 20"
! Sets Fourth TG Pattern Repetition Count (TGPRC) to 20 repetitions.
|
CALL:COMPressed:TGPSequence([1]|2|3|4):TGSNumber
|
Function
|
Sets/queries
<num> TG Starting Slot Number (TGSN)
for the first, second, third or fourth TGPS (sending :TGPSequence or :TGPSequence1 sets
First TG Starting Slot Number (TGSN)
, sending :TGPSequence2 sets
Second TG Starting Slot Number (TGSN)
, etc.). You can set
TG Starting Slot Number (TGSN)
for all four TGPSs using the
CALL:COMPressed:TGPSequence:ALL:TGSNumber
command.
If
TGPS Definition During Call Setup
is set to
Off
, this parameter can only be changed when compressed mode is not active. If
TGPS Definition During Call Setup
is set to
RB Setup
, this parameter can only be changed when the connection status is idle.
|
|
Setting
|
Range: 0 to 14 (slot 0 to slot 14)
Resolution: 1
|
|
Query
|
Same as setting |
|
*RST Setting
|
-
First TGPS: 11 (slot 11)
-
Second TGPS: 11 (slot 11)
-
Third TGPS: 11 (slot 11)
-
Fourth TGPS: 11 (slot 11)
|
|
Requirements |
Lab Application Revision: B.01 and above
Lab Application Revision D.00.04, added ([1]|2|3|4)
|
|
Programming Example
OUTPUT 714;"CALL:COMPressed:TGPSequence:TGSNumber 10"
! Sets First TG Starting Slot (TGSN) to slot 10.
|
|
|