Agilent Technologies Home Page 8960 Series 10 Wireless Communications Test Set
- +
Home | Product Web Site | Contact Us
+
- -
+ -
8960 W-CDMA/HSPA Online User's Guide
E1963A, E6703E
Search this guide for     
search tips



Feedback
Did the information on this web page help answer your question or solve a problem?

Yes
No
Did not apply

Please provide additional comments about this page.
(Optional, 255 character max)


Email address (optional):

Privacy Notice: We will not sell or give away your email address to any third party.

 



CALL:EIDentity

Last updated: March 16, 2009

GPIB Command Conventions

CALL[:CELL]:EIDentity:REQuest]

Function

Sets/queries Equipment Identity Request .

This setting cannot be changed when the cell operating mode is Active Cell and the call/data status is not IDLE. If you attempt to change this setting when the cell operating mode is Active Cell and the call/data status is not IDLE, the test set will reject the change and an error will be reported.

Setting

Range: IMEI|EISV|ALL

Query

Range: IMEI|EISV|ALL

*RST Setting

IMEI

Requirements

Lab Application Revision: E.00.34 and above

Test Application Revision: A.13 and above

Programming Example

 
OUTPUT 714;"CALL:CELL:EIDentity:REQuest IMEI" 
!Sets the application to request the IMEI from the UE.


Top of pagetop of page     

+ +