CALL:FDDTest
Last updated: September 2, 2009
GPIB Command Conventions
CALL:FDDTest:CCPChannel:PRIMary[:SLEVel]
|
Function
|
The setting form of this command performs two functions: (1) sets the
FDD Test P-CCPCH/SCH Level
(see
CALL:FDDTest:CCPChannel:PRIMary:LEVel
) and (2) sets the FDD Test P-CCPCH/SCH state to on (see
CALL:FDDTest:CCPChannel:PRIMary:STATe
).
The query form of this command returns the
FDD Test P-CCPCH/SCH Level
.
See
FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-5.35 dB (on) |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:CCPChannel:PRIMary -13"
! Sets the FDD Test P-CCPCH/SCH Level to -13 dB and turns its state on.
|
CALL:FDDTest:CCPChannel:PRIMary[:SLEVel]:HSDPa
|
Function
|
The setting form of this command performs two functions: (1) sets the
HSDPA FDD Test P-CCPCH/SCH Level
(see
CALL:FDDTest:CCPChannel:PRIMary:LEVel:HSDPa
) and (2) sets the HSDPA FDD Test P-CCPCH/SCH state to on (see
CALL:FDDTest:CCPChannel:PRIMary:STATe:HSDPa
).
The query form of this command returns the
HSDPA FDD Test P-CCPCH/SCH Level
.
See
HSDPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-12 dB (on) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:CCPChannel:PRIMary:HSDPa -13"
! Sets the HSDPA FDD Test P-CCPCH/SCH Level to -13 dB and turns its state on.
|
CALL:FDDTest:CCPChannel:PRIMary[:SLEVel]:HSPA
|
Function
|
The setting form of this command performs two functions: (1) sets the
HSPA FDD Test P-CCPCH/SCH Level
(see
CALL:FDDTest:CCPChannel:PRIMary:LEVel:HSPA
) and (2) sets the HSPA FDD Test P-CCPCH/SCH state to on (see
CALL:FDDTest:CCPChannel:PRIMary:STATe:HSPA
).
The query form of this command returns the
HSPA FDD Test P-CCPCH/SCH Level
.
See
HSPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-12 dB (on) |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:CCPChannel:PRIMary:HSPA -13"
! Sets the HSPA FDD Test P-CCPCH/SCH Level to -13 dB and turns its state on.
|
CALL:FDDTest:CCPChannel:PRIMary:LEVel
|
Function
|
Sets/queries the
FDD Test P-CCPCH/SCH Level
. See
FDD Test Operating Mode
.
The
FDD Test P-CCPCH/SCH Level
can also be set using the
CALL:FDDTest:CCPChannel:PRIMary[:SLEVel]
command.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-5.35 dB |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:CCPChannel:PRIMary:LEVel -7"
|
CALL:FDDTest:CCPChannel:PRIMary:LEVel:HSDPa
|
Function
|
Sets/queries the
HSDPA FDD Test P-CCPCH/SCH Level
. See
HSDPA in FDD Test Operating Mode
.
The
HSDPA FDD Test P-CCPCH/SCH Level
can also be set using the
CALL:FDDTest:CCPChannel:PRIMary[:SLEVel]:HSDPa
command.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting. |
|
*RST Setting
|
-12 dB |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:CCPChannel:PRIMary:LEVel:HSDPa -7"
|
CALL:FDDTest:CCPChannel:PRIMary:LEVel:HSPA
|
Function
|
Sets/queries the
HSPA FDD Test P-CCPCH/SCH Level
. See
HSPA in FDD Test Operating Mode
.
The
HSPA FDD Test P-CCPCH/SCH Level
can also be set using the
CALL:FDDTest:CCPChannel:PRIMary[:SLEVel]:HSPA
command.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting. |
|
*RST Setting
|
-12 dB |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:CCPChannel:PRIMary:LEVel:HSPA -7"
|
CALL:FDDTest:CCPChannel:PRIMary:STATe
|
Function
|
Sets/queries the
FDD Test P-CCPCH/SCH
state. See
FDD Test Operating Mode
.
The
FDD Test P-CCPCH/SCH
state can also be set using the
CALL:FDDTest:CCPChannel:PRIMary[:SLEVel]
command.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:CCPChannel:PRIMary:STATe ON"
|
CALL:FDDTest:CCPChannel:PRIMary:STATe:HSDPa
|
Function
|
Sets/queries the
HSDPA FDD Test P-CCPCH/SCH
state. See
HSDPA in FDD Test Operating Mode
.
The
HSDPA FDD Test P-CCPCH/SCH
state can also be set using the
CALL:FDDTest:CCPChannel:PRIMary[:SLEVel]
command.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:CCPChannel:PRIMary:STATe:HSDPa ON"
|
CALL:FDDTest:CCPChannel:PRIMary:STATe:HSPA
|
Function
|
Sets/queries the
HSPA FDD Test P-CCPCH/SCH
state. See
HSPA in FDD Test Operating Mode
.
The
HSPA FDD Test P-CCPCH/SCH
state can also be set using the
CALL:FDDTest:CCPChannel:PRIMary[:SLEVel]:HSDPa
command.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:CCPChannel:PRIMary:STATe:HSPA ON"
|
CALL:FDDTest:CLPControl:UPLink:ALGorithm
|
Function
|
Sets/queries the
FDD Test UL CL Power Ctrl Algorithm
.
|
|
Setting
|
Range:
|
|
Query
|
Same as setting |
|
*RST Setting
|
ALG2 |
|
Requirements
|
Test Application Revision A.07 and above
Lab Application Revision C.02 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:CLPControl:UPLink:ALGorithm ALG1"
! Sets FDD Test UL CL Power Ctrl Algorithm to One.
|
CALL:FDDTest:CLPControl:UPLink:MODE
|
Function
|
Sets/queries the
FDD Test UL CL Power Ctrl Mode
.
|
|
Setting
|
Range:
-
ACTive (Active bits)
-
DOWN (All Down bits)
-
UDOWn (Alternating bits)
-
UDOWn10 (10 Up/Down bits)
-
UP (All Up bits)
|
|
Query
|
Range: ACT|DOWN|UDOW|UDOW10|UP
|
|
*RST Setting
|
UDOW |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
Test Application Revision A.07 and above added ACTive
Lab Application Revision C.02 and above added ACTive
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:CLPCONTROL:UPLink:MODE UDOWN"
!Sets the closed loop power control mode to alternating up, down bits.
|
CALL:FDDTest:CLPControl:UPLink:STEPsize
CALL:FDDTest:COMPressed:DACTivation:TYPe
|
Function
|
Sets/queries
Deactivation Type
.
|
|
Setting
|
Range:
-
IMM (Immediate)
-
CFN (Specific CFN)
|
|
Query
|
Same as setting. |
|
*RST Setting
|
IMM |
|
Requirements
|
Lab Application Revision: B.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:COMPressed:DACTivation:TYPe CFN"
! Sets deactivation type to CFN.
|
CALL:FDDTest:COMPressed:ECFNumber
|
Function
|
Sets/queries
Ending CFN
.
|
|
Setting
|
Range: 0 to 255
Resolution: 1
|
|
Query
|
Same as setting. |
|
*RST Setting
|
0 |
|
Requirements
|
Lab Application Revision: B.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:COMPressed:ECFNumber 16"
|
CALL:FDDTest:COMPressed:SCFNumber
CALL:FDDTest:COMPressed:TGPSequence:ALL:SCFNumber
|
Function
|
Sets/queries
<num> TG Starting CFN
for the first through fourth TGPSs (the first num value sets
First TG Starting CFN
, the second num value sets
Second TG Starting CFN
, etc.). You can set TG Starting CFN for an individual TGPS using the
CALL:FDDTest:COMPressed:TGPSequence([1]|2|3|4):SCFNumber
commands.
|
|
Setting
|
Range: 0 to 255
Resolution: 1
|
|
Query
|
Same as setting. |
|
*RST Setting
|
0,2,6,14 |
|
Requirements
|
Lab Application Revision: D.00.04 and above. |
|
Programming Example
OUTPUT 714;"CALL:FDDTest:COMPressed:TGPSequence:ALL:SCFNumber 0,4,12,28"
! Sets First TG Starting CFN to 0, Second TG Starting CFN to 4,
! Third TG Starting CFN to 12, and Fourth TG Starting CFN to 28.
|
CALL:FDDTest:COMPressed:TGPSequence([1]|2|3|4):SCFNumber
|
Function
|
Sets/queries
<num> TG Starting CFN
for the first, second, third or fourth TGPS (sending :TGPSequence or :TGPSequence1 sets
First TG Starting CFN
, sending :TGPSequence2 sets
Second TG Starting CFN
, etc.). You can set
TG Starting CFN
for all four TGPSs using the
CALL:FDDTest:COMPressed:TGPSequence:ALL:SCFNumber
command.
|
|
Setting
|
Range: 0 to 255
Resolution: 1
|
|
Query
|
Same as setting. |
|
*RST Setting
|
-
First TGPS: 0
-
Second TGPS: 2
-
Third TGPS: 6
-
Fourth TGPS: 14
|
|
Requirements
|
Lab Application Revision: D.00.04 and above. |
|
Programming Example
OUTPUT 714;"CALL:FDDTest:COMPressed:TGPSequence3:SCFNumber 12"
! Sets Third TG Starting CFN to 12.
|
CALL:FDDTest:CPC:ACFNumber
|
Function
|
Sets/queries the CPC Activation CFN. This setting controls the specific CFN used by the UE and test set to start the CPC operation immediately after radio frames determined by the "Enabling Delay" parameter has passed.
|
|
Setting
|
Range: 0 to 255
Resolution: 1
|
|
Query
|
Same as setting. |
|
*RST Setting
|
0 |
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:FDDTest:CPC:ACFNumber 0"
! Sets the CPC Activation CFN to 0.
|
CALL:FDDTest:CPC:CONFigured
|
Function
|
Queries the CPC Configured parameter.
This setting determines whether to start or stop the CPC operation with the mode specified using the "CPC Mode" parameter. |
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 |
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:FDDTest:CPC:CONFigured 0"
|
CALL:FDDTest:CPIChannel[:SLEVel]
|
Function
|
The setting form of this command performs two functions: (1) sets the
FDD Test CPICH Level
(see
CALL:FDDTest:CPIChannel:LEVel
) and (2) sets the FDD Test CPICH state to on (see
CALL:FDDTest:CPIChannel:STATe
).
The query form of this command returns the
FDD Test CPICH Level
.
See
FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-3.3 dB (on) |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:CPIChannel -13"
! Sets the FDD Test CPICH Level to -13 dB and turns its state on.
|
CALL:FDDTest:CPIChannel[:SLEVel]:HSDPa
|
Function
|
The setting form of this command performs two functions: (1) sets the
HSDPA FDD Test CPICH Level
(see
CALL:FDDTest:CPIChannel:LEVel:HSDPa
) and (2) sets the HSDPA FDD Test CPICH state to on (see
CALL:FDDTest:CPIChannel:STATe:HSDPa
).
The query form of this command returns the
HSDPA FDD Test CPICH Level
.
See
HSDPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-10 dB (on) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:CPIChannel:HSDPa -13"
! Sets the HSDPA FDD Test CPICH Level to -13 dB and turns its state on.
|
CALL:FDDTest:CPIChannel[:SLEVel]:HSPA
|
Function
|
The setting form of this command performs two functions: (1) sets the
HSPA FDD Test CPICH Level
(see
CALL:FDDTest:CPIChannel:LEVel:HSPA
) and (2) sets the HSPA FDD Test CPICH state to on (see
CALL:FDDTest:CPIChannel:STATe:HSPA
).
The query form of this command returns the
HSPA FDD Test CPICH Level
.
See
HSPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-10 dB (on) |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:CPIChannel:HSPA -13"
! Sets the HSPA FDD Test CPICH Level to -13 dB and turns its state on.
|
CALL:FDDTest:CPIChannel:LEVel
|
Function
|
Sets/queries the
FDD Test CPICH Level
. See
FDD Test Operating Mode
.
The
FDD Test CPICH Level
can also be set using the
CALL:FDDTest:CPIChannel[:SLEVel]
command.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-3.3 dB |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:CPIChannel:LEVel -7"
|
CALL:FDDTest:CPIChannel:LEVel:HSDPa
|
Function
|
Sets/queries the
HSDPA FDD Test CPICH Level
. See
HSDPA in FDD Test Operating Mode
.
The
HSDPA FDD Test CPICH Level
can also be set using the
CALL:FDDTest:CPIChannel[:SLEVel]:HSDPa
command.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-10 dB |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:CPIChannel:LEVel:HSDPa -7"
|
CALL:FDDTest:CPIChannel:LEVel:HSPA
|
Function
|
Sets/queries the
HSPA FDD Test CPICH Level
. See
HSPA in FDD Test Operating Mode
.
The
HSPA FDD Test CPICH Level
can also be set using the
CALL:FDDTest:CPIChannel[:SLEVel]:HSPA
command.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-10 dB |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:CPIChannel:LEVel:HSPA -7"
|
CALL:FDDTest:CPIChannel:STATe
|
Function
|
Sets/queries the
FDD Test CPICH
state. See
FDD Test Operating Mode
.
The
FDD Test CPICH
state can also be set using the
CALL:FDDTest:CPIChannel[:SLEVel]
command.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:CPIChannel:STATe ON"
|
CALL:FDDTest:CPIChannel:STATe:HSDPa
|
Function
|
Sets/queries the
HSDPA FDD Test CPICH
state. See
HSDPA in FDD Test Operating Mode
.
The
HSDPA FDD Test CPICH
state can also be set using the
CALL:FDDTest:CPIChannel[:SLEVel]:HSDPa
command.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:CPIChannel:STATe:HSDPa ON"
|
CALL:FDDTest:CPIChannel:STATe:HSPA
|
Function
|
Sets/queries the
HSPA FDD Test CPICH
state. See
HSPA in FDD Test Operating Mode
.
The
HSPA FDD Test CPICH
state can also be set using the
CALL:FDDTest:CPIChannel[:SLEVel]:HSPA
command.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:CPIChannel:STATe:HSPA ON"
|
CALL:FDDTest:DPCHannel[:SLEVel]
|
Function
|
The setting form of this command performs two functions: (1) sets the
FDD Test DPCH Level
(see
CALL:FDDTest:DPCHannel:LEVel
) and (2) sets the FDD Test DPCH state to on (see
CALL:FDDTest:DPCHannel:STATe
).
The query form of this command returns the
FDD Test DPCH Level
.
See
FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-10.3 dB (on) |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:DPCHannel -13"
! Sets the FDD Test DPCH Level to -13 dB and turns its state on.
|
CALL:FDDTest:DPCHannel[:SLEVel]:HSDPa
|
Function
|
The setting form of this command performs two functions: (1) sets the
HSDPA FDD Test DPCH Level
(see
CALL:FDDTest:DPCHannel:LEVel:HSDPa
) and (2) sets the HSDPA FDD Test DPCH state to on (see
CALL:FDDTest:DPCHannel:STATe:HSDPa
).
The query form of this command returns the
HSDPA FDD Test DPCH Level
.
See
HSDPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-10 dB (on) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:DPCHannel:HSDPa -13"
! Sets the HSDPA FDD Test DPCH Level to -13 dB and turns its state on.
|
CALL:FDDTest:DPCHannel[:SLEVel]:HSPA
|
Function
|
The setting form of this command performs two functions: (1) sets the
HSPA FDD Test DPCH Level
(see
CALL:FDDTest:DPCHannel:LEVel:HSPA
) and (2) sets the
HSPA FDD Test DPCH
state to on (see
CALL:FDDTest:DPCHannel:STATe:HSPA
).
The query form of this command returns the
HSPA FDD Test DPCH Level
.
See
HSPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-10 dB (on) |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:DPCHannel:HSPA -13"
! Sets the HSPA FDD Test DPCH Level to -13 dB and turns its state on.
|
CALL:FDDTest:DPCHannel:FOFFset
|
Function
|
Sets/queries
DPCH Frame Offset
. |
|
Setting
|
Range: 0 to 10
Resolution: 1
|
|
Query
|
Same as setting |
|
*RST Setting
|
0 (0 x 256 chips) |
|
Requirements
|
Test Application Revision: A.09 and above
Lab Application Revision: C.04 and above
Lab Application Revision: D.00 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:DPCHannel:FOFFset 6"
! Sets DPCH Frame Offset to 6 x 256 chips.
|
CALL:FDDTest:DPCHannel:LEVel
|
Function
|
Sets/queries the
FDD Test DPCH Level
. See
FDD Test Operating Mode
.
The
FDD Test DPCH Level
can also be set using the
CALL:FDDTest:DPCHannel[:SLEVel]
command.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-10.3 dB |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:DPCHannel:LEVel -7"
|
CALL:FDDTest:DPCHannel:LEVel:HSDPa
|
Function
|
Sets/queries the
HSDPA FDD Test DPCH Level
. See
HSDPA in FDD Test Operating Mode
.
The
HSDPA FDD Test DPCH Level
can also be set using the
CALL:FDDTest:DPCHannel[:SLEVel]:HSDPa
command.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-10 dB |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:DPCHannel:LEVel:HSDPa -7"
|
CALL:FDDTest:DPCHannel:LEVel:HSPA
|
Function
|
Sets/queries the
HSPA FDD Test DPCH Level
. See
HSPA in FDD Test Operating Mode
.
The
HSPA FDD Test DPCH Level
can also be set using the
CALL:FDDTest:DPCHannel[:SLEVel]:HSPA
command.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-10 dB |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:DPCHannel:LEVel:HSPA -7"
|
CALL:FDDTest:DPCHannel:STATe
|
Function
|
Sets/queries the
FDD Test DPCH
state. See
FDD Test Operating Mode
.
The
FDD Test DPCH
state can also be set using the
CALL:FDDTest:DPCHannel[:SLEVel]
command.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:DPCHannel:STATe ON"
|
CALL:FDDTest:DPCHannel:STATe:HSDPa
|
Function
|
Sets/queries the
HSDPA FDD Test DPCH
state. See
HSDPA in FDD Test Operating Mode
.
The
HSDPA FDD Test DPCH
state can also be set using the
CALL:FDDTest:DPCHannel[:SLEVel]:HSDPa
command.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:DPCHannel:STATe:HSDPa ON"
|
CALL:FDDTest:DPCHannel:STATe:HSPA
|
Function
|
Sets/queries the
HSPA FDD Test DPCH
state. See
HSPA in FDD Test Operating Mode
.
The
HSPA FDD Test DPCH
state can also be set using the
CALL:FDDTest:DPCHannel[:SLEVel]:HSPA
command.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:DPCHannel:STATe:HSPA ON"
|
CALL:FDDTest:EAGChannel[:SLEVel]
|
Function
|
The setting form of this command performs two functions: (1) sets the
HSPA FDD Test E-AGCH Level
(see
CALL:FDDTest:EAGChannel:LEVel
) and (2) sets the
FDD Test E-AGCH
state to on (see
CALL:FDDTest:EAGChannel:STATe
).
The query form of this command returns the
HSPA FDD Test E-AGCH Level
.
See
HSPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-20 dB (on) |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:EAGChannel -20"
! Sets the HSPA FDD Test E-AGCH Level
to -20 dB and turns its state on.
|
CALL:FDDTest:EAGChannel:LEVel
|
Function
|
Sets/queries the
HSPA FDD Test E-AGCH Level
.
The
HSPA FDD Test E-AGCH Level
can also be set using the
CALL:FDDTest:EAGChannel[:SLEVel]
command.
See
HSPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-20 dB |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:EAGChannel:LEVel -20"
|
CALL:FDDTest:EAGChannel:STATe
|
Function
|
Sets/queries the
HSPA FDD Test E-AGCH Level
state.
The
HSPA FDD Test E-AGCH Level
state can also be set using the
CALL:FDDTest:EAGChannel[:SLEVel]
command.
See
HSPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:EAGChannel:STATe ON"
|
CALL:FDDTest:EDPDchannel:CCODes:MAX
|
Function
|
Sets/queries
FDD Test E-DPDCH Max Channel Codes
.
|
|
Setting
|
Range: SF64|SF32|SF16|SF8|SF4|TSF4|TSF2
|
|
Query
|
Same as setting
|
|
*RST Setting
|
TSF4 |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:EDPDchannel:CCODes:MAX TSF4"
! Sets FDD Test E-DPDCH Max Channel Codes to 2SF4.
|
CALL:FDDTest:EDPDchannel:CCODes:MAX:HSPA
|
Function
|
Sets/queries the FDD Test Mode E-DPDCH Max Channelisation Codes (HSPA Only).
This setting is used to inform the test set what value the UE is using for E-DPDCH Max Channelisation Codes while operating in FDD Test Mode with "UTRA FDD RB Test Mode Channel Type" set to"HSPA Only." This value is required to be able to translate the E-TFCI value that the UE transmits on the E-DPCCH to the spreading factor and number of channels used on the E-DPDCH.If "UTRA FDD RB Test Mode Channel Type" is set to "12.2k RMC + HSPA," this parameter is ignored.
|
|
Setting
|
Range: SF64|SF32|SF16|SF8|SF4|TSF4|TSF2|T2T4 (2SF2+2SF4)
|
|
Query
|
Same as setting
|
|
*RST Setting
|
T2T4 (2SF2+2SF4) |
|
Requirements
|
Test Application Revision A.13 and above, with the required feature license.
Lab Application Revision: E.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:EDPDchannel:CCODes:MAX:HSPA T2T4"
! Sets FDD Test E-DPDCH Max Channel Codes (HSPA Only) to 2SF2+2SF4.
|
CALL:FDDTest:EHIChannel[:SLEVel]
|
Function
|
The setting form of this command performs two functions: (1) sets the
HSPA FDD Test E-HICH Level
(see
CALL:FDDTest:EHIChannel:LEVel
) and (2) sets the
HSPA FDD Test E-HICH Level
state to on (see
CALL:FDDTest:EHIChannel:STATe
).
The query form of this command returns the
HSPA FDD Test E-HICH Level
.
See
HSPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-20 dB (on) |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:EHIChannel -20"
! Sets the HSPA FDD Test E-HICH Level
to -20 dB and turns its state on.
|
CALL:FDDTest:EHIChannel:LEVel
|
Function
|
Sets/queries the
HSPA FDD Test E-HICH Level
.
The
HSPA FDD Test E-HICH Level
can also be set using the
CALL:FDDTest:EHIChannel[:SLEVel]
command.
See
HSPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-20 dB |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:EHIChannel:LEVel -20"
|
CALL:FDDTest:EHIChannel:STATe
|
Function
|
Sets/queries the
HSPA FDD Test E-HICH Level
state.
The
HSPA FDD Test E-HICH Level
state can also be set using the
CALL:FDDTest:EHIChannel[:SLEVel]
command.
See
HSPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:EHIChannel:STATe ON"
|
CALL:FDDTest:ERGChannel[:SLEVel]
|
Function
|
The setting form of this command performs two functions: (1) sets the
HSPA FDD Test E-RGCH Level
(see
CALL:FDDTest:ERGChannel:LEVel
) and (2) sets the
HSPA FDD Test E-RGCH Level
state to on (see
CALL:FDDTest:ERGChannel:STATe
).
The query form of this command returns the
HSPA FDD Test E-RGCH Level
.
See
HSPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-20 dB (off) |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:ERGChannel -20"
! Sets the HSPA FDD Test E-RGCH Level
to -20 dB and turns its state on.
|
CALL:FDDTest:ERGChannel:LEVel
|
Function
|
Sets/queries the
HSPA FDD Test E-RGCH Level
.
The
HSPA FDD Test E-RGCH Level
can also be set using the
CALL:FDDTest:ERGChannel[:SLEVel]
command.
See
HSPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-20 dB |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:ERGChannel:LEVel -20"
|
CALL:FDDTest:ERGChannel:STATe
|
Function
|
Sets/queries the
HSPA FDD Test E-RGCH Level
state.
The
HSPA FDD Test E-RGCH Level
state can also be set using the
CALL:FDDTest:ERGChannel[:SLEVel]
command.
See
HSPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:ERGChannel:STATe OFF"
|
CALL:FDDTest:FDPChannel:SLOT:FORMat
|
Function
|
Sets/queries FDD Test Mode F-DPCH Slot Format. |
|
Setting
|
Range: 0 to 9
Resolution: 1
|
|
Query
|
Same as setting |
|
*RST Setting
|
0 |
|
Requirements
|
Test Application Revision: A.15 and above
Lab Application Revision: F.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:FDPChannel:SLOT:FORMat 0"
! Sets FDD Test Mode F-DPCH Slot Format to 0.
|
CALL:FDDTest:FDPChannel:STATe
|
Function
|
Sets/queries the
FDD Test F-DPCH State
.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Lab Application Revision: F.00 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:FDPChannel:STATe OFF"
|
CALL:FDDTest:FRC:HSET8:MS:IREDundancy:BUFFer:SIZE
|
Function
|
Sets/queries the FDD Test Mode FRC H-Set 8 UE IR Buffer Size.
This Setting controls the FDD Test Mode H-Set 8 UE IR Buffer Size, either 40000 bits or as specified in 25.101v870. If this setting is Standard (STD), the test set will determine the IR buffer size per HARQ process.
|
|
Setting
|
Range: 40000|STD
|
|
Query
|
Same as setting |
|
*RST Setting
|
40000 |
|
Requirements
|
Test Application Revision A.15 and above.
Lab Application Revision: F.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:FRC:HSET8:MS:IREDundancy:BUFFer:SIZE 40000"
! Sets FDD Test Mode FRC H-Set 8 UE IR Buffer Size to 40000 bits.
|
CALL:FDDTest:FRC:TYPE
|
Function
|
Sets/queries the
FDD Test "FRC Type" on page 1
.
|
|
Setting
|
Range: QAM1|QAM2|QAM3|QAM6|QAM64H8|QAM16H10|QPSK1|QPSK2|QPSK3|QPSK4|
QPSK5|QPSK6|QPSKH10
|
|
Query
|
Same as setting |
|
*RST Setting
|
QPSK1 |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
Test Application Revision A.10.01 and Lab Application Revision D.01.01 added QAM6 and QPSK6.
Lab Application Revision F.00 added QAM64H8, QAM16H10, QPSKH10
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:FRC:TYPE QPSK2"
! Sets FRC Type to H-Set 2 QPSK.
|
CALL:FDDTest:HRNTi[:PRIMary]
|
Function
|
Sets/queries
FDD Test
Primary H-RNTI (Hex)
.
|
|
Setting
|
Range: 0 to FFFF
(1 to 4 characters from the set 0123456789AaBbCcDdEeFf)
|
|
Query
|
Range: "0000" to "FFFF"
(The return string is always 4 characters from the set 0123456789ABCDEF, enclosed by double quotes.)
|
|
*RST Setting
|
"AAAA" |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HRNTi 'EEEE'"
! Sets FDD Test Primary H-RNTI (Hex) to EEEE.
|
CALL:FDDTest:HRNTi:ALTernate
|
Function
|
Sets/queries
FDD Test
Alternate H-RNTI (Hex)
.
|
|
Setting
|
Range: 0 to FFFF
(1 to 4 characters from the set 0123456789AaBbCcDdEeFf)
|
|
Query
|
Range: "0000" to "FFFF"
(The return string is always 4 characters from the set 0123456789ABCDEF, enclosed by double quotes.)
|
|
*RST Setting
|
"5555" |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HRNTi:ALTernate '2222'"
! Sets FDD Test Alternate H-RNTI (Hex) to 2222.
|
CALL:FDDTest:HSDSchannel:CONFig[:TYPE]
|
Function
|
Sets/queries
FDD Test "RB Test HS-DSCH Configuration Type" on page 1
. |
|
Setting
|
Range: FRC|UDEFined
|
|
Query
|
Same as setting |
|
*RST Setting
|
FRC |
|
Requirements
|
Test Application Revision: A.09 and above, with the required feature license
Lab Application Revision: C.04 and above
Lab Application Revision: D.00 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSDSchannel:CONFig UDEFined"
! Sets FDD Test HS-DSCH Configuration Type to User Defined.
|
CALL:FDDTest:HSDSchannel:DATA
|
Function
|
Sets/queries
FDD Test "HS-DSCH Data Pattern"
.
|
|
Setting
|
Range:
-
ABITs (Alternating)
-
INCRement (Incrementing)
-
ONES (All Ones)
-
PRBS23 (CCITT PRBS23)
-
PRBS20 (CCITT PRBS20)
-
PRBS15 (CCITT PRBS15)
-
PRBS9 (CCITT PRBS9)
-
ZERos (All Zeros)
|
|
Query
|
Range:
-
ABIT (Alternating)
-
INCR (Incrementing)
-
ONES (All Ones)
-
PRBS23 (CCITT PRBS23)
-
PRBS20 (CCITT PRBS20)
-
PRBS15 (CCITT PRBS15)
-
PRBS9 (CCITT PRBS9)
-
ZER (All Zeros)
|
|
*RST Setting
|
PRBS15 |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
Lab Application Revision: F.00 added PRBS23 and PRBS20
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSDSchannel:DATA ONES"
! Sets FDD Test HS-DSCH Data Pattern to All Ones.
|
CALL:FDDTest:HSDSchannel:MS:CATegory
|
Function
|
Sets/queries
FDD Test UE HS-DSCH Category
.
This command is only applicable when
CALL:FDDTest:HSDSchannel:UDEFined:MS:IREDundancy:BUFFer:ALLocation
is set to
IMPLicit
.
|
|
Setting
|
Range: 1 to 8, 11, 12
Resolution: 1
|
|
Query
|
Same as setting |
|
*RST Setting
|
1 |
|
Requirements
|
Test Application Revision: A.09 and above, with the required feature license
Lab Application Revision: C.04 and above
Lab Application Revision: D.00 and above
Test Application Revision A.10 and Lab Application Revision D.01 added UE categories 7 and 8
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSDSchannel:MS:CATegory 12"
! Sets FDD Test UE HS-DSCH Category to 12.
|
CALL:FDDTest:HSDSchannel:UDEFined:HARQ:PROCess:COUNt
|
Function
|
Sets/queries
FDD Test "User Defined Number of HARQ Processes" on page 5
. |
|
Setting
|
Range: 1 to 8
Resolution: 1
|
|
Query
|
Same as setting |
|
*RST Setting
|
2 |
|
Requirements
|
Test Application Revision: A.09 and above, with the required feature license
Lab Application Revision: C.04 and above
Lab Application Revision: D.00 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSDSchannel:UDEFined:HARQ:PROCess:COUNt 1"
! Sets FDD Test User Defined Number of HARQ Processes to 1.
|
CALL:FDDTest:HSDSchannel:UDEFined:HSPDschannel:COUNt
|
Function
|
Sets/queries
FDDT "User Defined Number of Active HS-PDSCHs" on page 3
. |
|
Setting
|
Range: 1 to 10
Resolution: 1
|
|
Query
|
Same as setting |
|
*RST Setting
|
5 |
|
Requirements
|
Test Application Revision: A.09 and above, with the required feature license
Lab Application Revision: C.04 and above
Lab Application Revision: D.00 and above
Test Application Revision A.10 and Lab Application Revision D.01 expanded range from "1 to 5" to "1 to 10"
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSDSchannel:UDEFined:HSPDschannel:COUNt 3"
! Sets FDDT User Defined Number of Active HS-PDSCHs to 3.
|
CALL:FDDTest:HSDSchannel:UDEFined:ITTI[:INTerval]
|
Function
|
Sets/queries
FDD Test "User Defined Inter-TTI Interval" on page 5
. |
|
Setting
|
Range: 1 to 3
Resolution: 1
|
|
Query
|
Same as setting |
|
*RST Setting
|
3 |
|
Requirements
|
Test Application Revision: A.09 and above, with the required feature license
Lab Application Revision: C.04 and above
Lab Application Revision: D.00 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSDSchannel:UDEFined:ITTI 1"
! Sets FDD Test User Defined Inter-TTI Interval to 1.
|
CALL:FDDTest:HSDSchannel:UDEFined:MAC
|
Function
|
Sets/queries
FDD Test "User Defined HS-DSCH MAC Entity" on page 6
. |
|
Setting
|
Range: HSPeed | EHSPeed
|
|
Query
|
Range: HSP | EHSP |
|
*RST Setting
|
HSPeed |
|
Requirements
|
Lab Application Revision: F.00 and above
Test Application Revision: A.14 and above, with the required feature license
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSDSchannel:UDEFined:MAC HSPeed"
! Sets the FDD Test Mode HS-DSCH MAC entity to MAC-hs.
|
CALL:FDDTest:HSDSchannel:UDEFined:MACEHS:TBSTable:ALIGnment
|
Function
|
Sets/queries
FDD Test "User Defined MAC-ehs HS-DSCH TB Size Table" on page 6
. |
|
Setting
|
Range: BIT | OCTet
|
|
Query
|
Range: BIT | OCT |
|
*RST Setting
|
OCTet |
|
Requirements
|
Lab Application Revision: F.00 and above
Test Application Revision: A.14 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSDSchannel:UDEFined:MACEHS:TBSTable:ALIGnment OCTet"
! Sets the FDD Test Mode MAC-ehs HS-DSCH TB size table to octet-aligned.
|
CALL:FDDTest:HSDSchannel:UDEFined:MODulation[:TYPE]
|
Function
|
Sets/queries
FDD Test "User Defined Modulation Type" on page 4
. |
|
Setting
|
Range: QPSK|QAM16|QAM64
|
|
Query
|
Same as setting |
|
*RST Setting
|
QPSK |
|
Requirements
|
Test Application Revision: A.09 and above, with the required feature license
Lab Application Revision: C.04 and above
Lab Application Revision: D.00 and above
Lab Application Revision: F.00 and Test Application Revision: A.14, added QAM64
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSDSchannel:UDEFined:MODulation QAM16"
! Sets FDD Test User Defined Modulation Type to 16QAM.
|
CALL:FDDTest:HSDSchannel:UDEFined:MS:IREDundancy:BUFFer:ALLocation
|
Function
|
Sets/queries
FDD Test User Defined UE IR Buffer Allocation
.
When this command is set to
IMPLicit
, the UE IR buffer size is determined by the
CALL:FDDTest:HSDSchannel:MS:CATegory
setting.
When this command is set to
EXPLicit
, the UE IR buffer size is determined by the
CALL:FDDTest:HSDSchannel:UDEFined:MS:IREDundancy:BUFFer:SIZE[:EXPLicit]
setting.
|
|
Setting
|
Range: IMPLicit|EXPLicit
|
|
Query
|
Same as setting |
|
*RST Setting
|
IMPLicit |
|
Requirements
|
Test Application Revision: A.09 and above, with the required feature license
Lab Application Revision: C.04 and above
Lab Application Revision: D.00 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSDSchannel:UDEFined:MS:IREDundancy:BUFFer:ALLocation EXPLicit"
! Sets FDD Test User Defined UE IR Buffer Allocation to Explicit.
|
CALL:FDDTest:HSDSchannel:UDEFined:MS:IREDundancy:BUFFer:SIZE[:EXPLicit]
|
Function
|
Sets/queries
FDDT "User Defined Explicit UE IR Buffer Size"
.
This command is only applicable when
CALL:FDDTest:HSDSchannel:UDEFined:MS:IREDundancy:BUFFer:ALLocation
is set to
EXPLicit
.
|
|
Setting
|
Range: 800, 1600, 2400, 3200, 4000, 4800, 5600, 6400, 7200, 8000, 8800, 9600, 10400, 11200, 12000, 12800, 13600, 14400, 15200, 16000, 17600, 19200, 20800, 22400, 24000, 25600, 27200, 28800, 30400, 32000, 36000, 40000, 44000, 48000, 52000, 56000, 60000, 64000, 68000, 72000, 76000, 80000, 88000, 96000, 104000, 112000, 120000, 128000, 136000, 144000, 152000, 160000, 176000, 192000, 208000, 224000, 240000, 256000, 272000, 288000, 304000
Resolution: 1
|
|
Query
|
Same as setting |
|
*RST Setting
|
19200 |
|
Requirements
|
Test Application Revision: A.09 and above, with the required feature license
Lab Application Revision: C.04 and above
Lab Application Revision: D.00 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSDSchannel:UDEFined:MS:IREDundancy:BUFFer:SIZE 9600"
! Sets FDDT User Defined Explicit UE IR Buffer Size to 9600.
|
CALL:FDDTest:HSDSchannel:UDEFined:TBSize:INDex
|
Function
|
Sets/queries
FDDT "User Defined Transport Block Size Index" on page 4
.
You can query the transport block size using the
CALL:STATus:HSDSchannel:TBSize?
query.
|
|
Setting
|
Range: 0 to 62
Resolution: 1
|
|
Query
|
Same as setting |
|
*RST Setting
|
62 |
|
Requirements
|
Test Application Revision: A.09 and above, with the required feature license
Lab Application Revision: C.04 and above
Lab Application Revision: D.00 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSDSchannel:UDEFined:TBSize:INDex 48"
! Sets FDDT User Defined Transport Block Size Index to 48.
|
CALL:FDDTest:HSDSchannel:UDEFined:QAM64:STATe
CALL:FDDTest:HSPDschannel[:SLEVel]
|
Function
|
The setting form of this command performs two functions: (1) sets the
HSDPA FDD Test HS-PDSCHs Level (Sum)
(see
CALL:FDDTest:HSPDschannel:LEVel
) and (2) sets the
HSDPA FDD Test HS-PDSCHs Level (Sum)
state to on (see
CALL:FDDTest:HSPDschannel:STATe
).
The query form of this command returns the
HSDPA FDD Test HS-PDSCHs Level (Sum)
.
See
HSDPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-3 dB (on) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSPDschannel -4"
! Sets the FDD Test HS-PDSCHs Level (Sum)
to -4 dB and turns its state on.
|
CALL:FDDTest:HSPDschannel[:SLEVel]:HSPA
|
Function
|
The setting form of this command performs two functions: (1) sets the
HSPA FDD Test HS-PDSCHs Level (Sum)
(see
CALL:FDDTest:HSPDschannel:LEVel:HSPA
) and (2) sets the
HSPA FDD Test HS-PDSCHs Level (Sum)
state to on (see
CALL:FDDTest:HSPDschannel:STATe:HSPA
).
The query form of this command returns the
HSPA FDD Test HS-PDSCHs Level (Sum)
.
See
HSPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-3 dB (on) |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSPDschannel:HSPA -4"
! Sets the HSPA FDD Test HS-PDSCHs Level (Sum)
to -4 dB and turns its state on.
|
CALL:FDDTest:HSPDschannel:CCODe
|
Function
|
THIS COMMAND IS OBSOLETE. Please use
CALL:FDDTest:HSPDschannel:CCODe:CODE
.
Sets/queries
FDD Test First HS-PDSCH Channelization Code
.
|
|
Setting
|
Range: CODE5|CODE6|CODE7|CODE8|CODE9|CODE10|CODE11|CODE12|CODE13|CODE14
|
|
Query
|
Same as setting |
|
*RST Setting
|
CODE7 |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
Test Application Revision A.10.01 and Lab Application Revision D.01.01 added CODE5 and CODE6.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSPDschannel:CCODe CODE8"
! Sets FDD Test First HS-PDSCH Channelization Code to 8.
|
CALL:FDDTest:HSPDschannel:CCODe:CODE
|
Function
|
Sets/queries
FDD Test First HS-PDSCH Channelization Code
.
|
|
Setting
|
Range: 1 to 15
|
|
Query
|
Same as setting |
|
*RST Setting
|
7 |
|
Requirements
|
Lab Application Revision: F.00 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSPDschannel:CCODe:CODE 7"
! Sets FDD Test First HS-PDSCH Channelization Code to 7.
|
CALL:FDDTest:HSPDschannel:LEVel
|
Function
|
Sets/queries the
HSDPA FDD Test HS-PDSCHs Level (Sum)
. See
HSDPA in FDD Test Operating Mode
.
The
HSDPA FDD Test HS-PDSCHs Level (Sum)
can also be set using the
CALL:FDDTest:HSPDschannel[:SLEVel]
command.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-3 dB |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSPDschannel:LEVel -4"
|
CALL:FDDTest:HSPDschannel:LEVel:HSPA
|
Function
|
Sets/queries the
HSPA FDD Test HS-PDSCHs Level (Sum)
. See
HSPA in FDD Test Operating Mode
.
The
HSPA FDD Test HS-PDSCHs Level (Sum)
can also be set using the
CALL:FDDTest:HSPDschannel[:SLEVel]:HSPA
command.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-3 dB |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSPDschannel:LEVel:HSPA -4"
|
CALL:FDDTest:HSPDschannel:STATe
|
Function
|
Sets/queries the
HSDPA FDD Test HS-PDSCHs Level (Sum)
state. See
HSDPA in FDD Test Operating Mode
.
The
HSDPA FDD Test HS-PDSCHs Level (Sum)
state can also be set using the
CALL:FDDTest:HSPDschannel[:SLEVel]
command.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSPDschannel:STATe ON"
|
CALL:FDDTest:HSPDschannel:STATe:HSPA
|
Function
|
Sets/queries the
HSPA FDD Test HS-PDSCHs Level (Sum)
state. See
HSPA in FDD Test Operating Mode
.
The
HSPA FDD Test HS-PDSCHs Level (Sum)
state can also be set using the
CALL:FDDTest:HSPDschannel[:SLEVel]:HSPA
command.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSPDschannel:STATe:HSPA ON"
|
CALL:FDDTest:HSSCchannel[1][:SLEVel]
|
Function
|
The setting form of this command performs two functions: (1) sets the
FDD Test HS-SCCH 1 Level
(see
CALL:FDDTest:HSSCchannel[1]:LEVel
) and (2) sets the
FDD Test HS-SCCH 1 Level
state to on (see
CALL:FDDTest:HSSCchannel[1]:STATe
).
The query form of this command returns the
FDD Test HS-SCCH 1 Level
.
See
HSDPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-10 dB (on) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel -11"
! Sets the FDD Test HS-SCCH 1 Level
to -11 dB and turns its state on.
|
CALL:FDDTest:HSSCchannel[1][:SLEVel]:HSPA
|
Function
|
The setting form of this command performs two functions: (1) sets the
HSPA FDD Test HS-SCCH 1 Level
(see
CALL:FDDTest:HSSCchannel[1]:LEVel:HSPA
) and (2) sets the
HSPA FDD Test HS-SCCH 1 Level
state to on (see
CALL:FDDTest:HSSCchannel[1]:STATe:HSPA
).
The query form of this command returns the
HSPA FDD Test HS-SCCH 1 Level
.
See
HSPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-10 dB (on) |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel:HSPA -11"
! Sets the HSPA FDD Test HS-SCCH 1 Level
to -11 dB and turns its state on.
|
CALL:FDDTest:HSSCchannel[1]:CONFig:STATe
|
Function
|
Sets/queries the FDD Test Mode HSDPA/HSPA HS-SCCH 1 Channel Configuration State.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Lab Application Revision: F.00 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel:CONFig:STATe ON"
|
CALL:FDDTest:HSSCchannel[1]:LEVel
|
Function
|
Sets/queries the
FDD Test HS-SCCH 1 Level
. See
HSDPA in FDD Test Operating Mode
.
The
FDD Test HS-SCCH 1 Level
can also be set using the
CALL:FDDTest:HSSCchannel[1][:SLEVel]
command.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-10 dB |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel:LEVel -11"
|
CALL:FDDTest:HSSCchannel[1]:LEVel:HSPA
|
Function
|
Sets/queries the
HSPA FDD Test HS-SCCH 1 Level
. See
HSPA in FDD Test Operating Mode
.
The
HSPA FDD Test HS-SCCH 1 Level
can also be set using the
CALL:FDDTest:HSSCchannel[1][:SLEVel]:HSPA
command.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-10 dB |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel:LEVel:HSPA -11"
|
CALL:FDDTest:HSSCchannel[1]:STATe
|
Function
|
Sets/queries the
FDD Test HS-SCCH 1 Level
state. See
HSDPA in FDD Test Operating Mode
.
The
FDD Test HS-SCCH 1 Level
state can also be set using the
CALL:FDDTest:HSSCchannel[1][:SLEVel]
command.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel:STATe ON"
|
CALL:FDDTest:HSSCchannel[1]:STATe:HSPA
|
Function
|
Sets/queries the
HSPA FDD Test HS-SCCH 1 Level
state. See
HSPA in FDD Test Operating Mode
.
The
HSPA FDD Test HS-SCCH 1 Level
state can also be set using the
CALL:FDDTest:HSSCchannel[1][:SLEVel]:HSPA
command.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel:STATe:HSPA ON"
|
CALL:FDDTest:HSSCchannel2[:SLEVel]
|
Function
|
The setting form of this command performs two functions: (1) sets the
FDD Test HS-SCCH 2 Level
(see
CALL:FDDTest:HSSCchannel2:LEVel
) and (2) sets the
FDD Test HS-SCCH 2 Level
state to on (see
CALL:FDDTest:HSSCchannel2:STATe
).
The query form of this command returns the
FDD Test HS-SCCH 2 Level
.
See
HSDPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-15 dB (off) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel2 -11"
! Sets the FDD Test HS-SCCH 2 Level
to -11 dB and turns its state on.
|
CALL:FDDTest:HSSCchannel2[:SLEVel]:HSPA
|
Function
|
The setting form of this command performs two functions: (1) sets the
HSPA FDD Test HS-SCCH 2 Level
(see
CALL:FDDTest:HSSCchannel2:LEVel:HSPA
) and (2) sets the
HSPA FDD Test HS-SCCH 2 Level
state to on (see
CALL:FDDTest:HSSCchannel2:STATe:HSPA
).
The query form of this command returns the
HSPA FDD Test HS-SCCH 2 Level
.
See
HSPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-15 dB (off) |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel2:HSPA -11"
! Sets the HSPA FDD Test HS-SCCH 2 Level
to -11 dB and turns its state on.
|
CALL:FDDTest:HSSCchannel2:CONFig:STATe
|
Function
|
Sets/queries the FDD Test Mode HSDPA/HSPA HS-SCCH 2 Channel Configuration State.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Lab Application Revision: F.00 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel2:CONFig:STATe ON"
|
CALL:FDDTest:HSSCchannel2:LEVel
|
Function
|
Sets/queries the
FDD Test HS-SCCH 2 Level
. See
HSDPA in FDD Test Operating Mode
.
The
FDD Test HS-SCCH 2 Level
can also be set using the
CALL:FDDTest:HSSCchannel2[:SLEVel]
command.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-15 dB |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel2:LEVel -11"
|
CALL:FDDTest:HSSCchannel2:LEVel:HSPA
|
Function
|
Sets/queries the
HSPA FDD Test HS-SCCH 2 Level
. See
HSPA in FDD Test Operating Mode
.
The
HSPA FDD Test HS-SCCH 2 Level
can also be set using the
CALL:FDDTest:HSSCchannel2[:SLEVel]:HSPA
command.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-15 dB |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel2:LEVel:HSPA -11"
|
CALL:FDDTest:HSSCchannel2:STATe
|
Function
|
Sets/queries the
FDD Test HS-SCCH 2 Level
state. See
HSDPA in FDD Test Operating Mode
.
The
FDD Test HS-SCCH 2 Level
state can also be set using the
CALL:FDDTest:HSSCchannel2[:SLEVel]
command.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel2:STATe ON"
|
CALL:FDDTest:HSSCchannel2:STATe:HSPA
|
Function
|
Sets/queries the
HSPA FDD Test HS-SCCH 2 Level
state. See
HSPA in FDD Test Operating Mode
.
The
HSPA FDD Test HS-SCCH 2 Level
state can also be set using the
CALL:FDDTest:HSSCchannel2[:SLEVel]:HSPA
command.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel2:STATe:HSPA ON"
|
CALL:FDDTest:HSSCchannel3[:SLEVel]
|
Function
|
The setting form of this command performs two functions: (1) sets the
FDD Test HS-SCCH 3 Level
(see
CALL:FDDTest:HSSCchannel3:LEVel
) and (2) sets the
FDD Test HS-SCCH 3 Level
state to on (see
CALL:FDDTest:HSSCchannel3:STATe
).
The query form of this command returns the
FDD Test HS-SCCH 3 Level
.
See
HSDPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-15 dB (off) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel3 -11"
! Sets the FDD Test HS-SCCH 3 Level
to -11 dB and turns its state on.
|
CALL:FDDTest:HSSCchannel3[:SLEVel]:HSPA
|
Function
|
The setting form of this command performs two functions: (1) sets the
HSPA FDD Test HS-SCCH 3 Level
(see
CALL:FDDTest:HSSCchannel3:LEVel:HSPA
) and (2) sets the
HSPA FDD Test HS-SCCH 3 Level
state to on (see
CALL:FDDTest:HSSCchannel3:STATe:HSPA
).
The query form of this command returns the
HSPA FDD Test HS-SCCH 3 Level
.
See
HSPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-15 dB (off) |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel3:HSPA -11"
! Sets the HSPA FDD Test HS-SCCH 3 Level
to -11 dB and turns its state on.
|
CALL:FDDTest:HSSCchannel3:CONFig:STATe
|
Function
|
Sets/queries the FDD Test Mode HSDPA/HSPA HS-SCCH 3 Channel Configuration State.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Lab Application Revision: F.00 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel3:CONFig:STATe ON"
|
CALL:FDDTest:HSSCchannel3:LEVel
|
Function
|
Sets/queries the
FDD Test HS-SCCH 3 Level
. See
HSDPA in FDD Test Operating Mode
.
The
FDD Test HS-SCCH 3 Level
can also be set using the
CALL:FDDTest:HSSCchannel3[:SLEVel]
command.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-15 dB |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel3:LEVel -11"
|
CALL:FDDTest:HSSCchannel3:LEVel:HSPA
|
Function
|
Sets/queries the
HSPA FDD Test HS-SCCH 3 Level
. See
HSPA in FDD Test Operating Mode
.
The
HSPA FDD Test HS-SCCH 3 Level
can also be set using the
CALL:FDDTest:HSSCchannel3[:SLEVel]:HSPA
command.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-15 dB |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel3:LEVel:HSPA -11"
|
CALL:FDDTest:HSSCchannel3:STATe
|
Function
|
Sets/queries the
FDD Test HS-SCCH 3 Level
state. See
HSDPA in FDD Test Operating Mode
.
The
FDD Test HS-SCCH 3 Level
state can also be set using the
CALL:FDDTest:HSSCchannel3[:SLEVel]
command.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel3:STATe ON"
|
CALL:FDDTest:HSSCchannel3:STATe:HSPA
|
Function
|
Sets/queries the
HSPA FDD Test HS-SCCH 3 Level
state. See
HSPA in FDD Test Operating Mode
.
The
HSPA FDD Test HS-SCCH 3 Level
state can also be set using the
CALL:FDDTest:HSSCchannel3[:SLEVel]:HSPA
command.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel3:STATe:HSPA ON"
|
CALL:FDDTest:HSSCchannel4[:SLEVel]
|
Function
|
The setting form of this command performs two functions: (1) sets the
FDD Test HS-SCCH 4 Level
(see
CALL:FDDTest:HSSCchannel4:LEVel
) and (2) sets the
FDD Test HS-SCCH 4 Level
state to on (see
CALL:FDDTest:HSSCchannel4:STATe
).
The query form of this command returns the
FDD Test HS-SCCH 4 Level
.
See
HSDPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-15 dB (off) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel4 -11"
! Sets the FDD Test HS-SCCH 4 Level
to -11 dB and turns its state on.
|
CALL:FDDTest:HSSCchannel4[:SLEVel]:HSPA
|
Function
|
The setting form of this command performs two functions: (1) sets the
HSPA FDD Test HS-SCCH 4 Level
(see
CALL:FDDTest:HSSCchannel4:LEVel:HSPA
) and (2) sets the
HSPA FDD Test HS-SCCH 4 Level
state to on (see
CALL:FDDTest:HSSCchannel4:STATe:HSPA
).
The query form of this command returns the
HSPA FDD Test HS-SCCH 4 Level
.
See
HSPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-15 dB (off) |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel4:HSPA -11"
! Sets the HSPA FDD Test HS-SCCH 4 Level
to -11 dB and turns its state on.
|
CALL:FDDTest:HSSCchannel4:CONFig:STATe
|
Function
|
Sets/queries the FDD Test Mode HSDPA/HSPA HS-SCCH 4 Channel Configuration State.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Lab Application Revision: F.00 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel4:CONFig:STATe ON"
|
CALL:FDDTest:HSSCchannel4:LEVel
|
Function
|
Sets/queries the
FDD Test HS-SCCH 4 Level
. See
HSDPA in FDD Test Operating Mode
.
The
FDD Test HS-SCCH 4 Level
can also be set using the
CALL:FDDTest:HSSCchannel4[:SLEVel]
command.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-15 dB |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel4:LEVel -11"
|
CALL:FDDTest:HSSCchannel4:LEVel:HSPA
|
Function
|
Sets/queries the
HSPA FDD Test HS-SCCH 4 Level
. See
HSPA in FDD Test Operating Mode
.
The
HSPA FDD Test HS-SCCH 4 Level
can also be set using the
CALL:FDDTest:HSSCchannel4[:SLEVel]:HSPA
command.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-15 dB |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel4:LEVel:HSPA -11"
|
CALL:FDDTest:HSSCchannel4:STATe
|
Function
|
Sets/queries the
FDD Test HS-SCCH 4 Level
state. See
HSDPA in FDD Test Operating Mode
.
The
FDD Test HS-SCCH 4 Level
state can also be set using the
CALL:FDDTest:HSSCchannel4[:SLEVel]
command.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel4:STATe ON"
|
CALL:FDDTest:HSSCchannel4:STATe:HSPA
|
Function
|
Sets/queries the
HSPA FDD Test HS-SCCH 4 Level
state. See
HSPA in FDD Test Operating Mode
.
The
HSPA FDD Test HS-SCCH 4 Level
state can also be set using the
CALL:FDDTest:HSSCchannel4[:SLEVel]:HSPA
command.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:HSSCchannel4:STATe:HSPA ON"
|
CALL:FDDTest:MACHs:HEADer
|
Function
|
Sets/queries the
MAC-hs Header
.
|
|
Setting
|
Range: PRESent|DATA
|
|
Query
|
Range: PRES|DATA
|
|
*RST Setting
|
PRES |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:MACHs:HEADer DATA"
! Sets the MAC-hs Header to Used for Data.
|
CALL:FDDTest:MACHs:NTRans
|
Function
|
Sets/queries the
FDD Test
Number of Transmissions
.
|
|
Setting
|
Range: 1 to 8
|
|
Query
|
Same as setting |
|
*RST Setting
|
4 |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:MACHs:NTRans 2"
! Sets the FDD Test Number of Transmissions to 2.
|
CALL:FDDTest:MACHs:RVSequence
|
Function
|
Sets/queries the
FDD Test
RV Sequence
.
Note: The number of RV parameters in the sequence that are used is determined by the
FDD Test Number of Transmissions
setting (see
CALL:FDDTest:MACHs:NTRans
). The RV parameters at the end of the list are not used if
FDD Test Number of Transmissions
is less than 8.
|
|
Setting
|
Range: Comma separated list of 1 to 8 characters from the set 01234567.
|
|
Query
|
Range: Comma separated list of 8 characters from the set 01234567, enclosed by double quotes (if you enter fewer than 8 characters, the query result will fill the remaining characters with zeros).
|
|
*RST Setting
|
0,2,5,6,0,0,0,0 |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:MACHs:RVSequence '0,2,7,4,3,1'"
! Sets the FDD Test RV Sequence to 0,2,7,4,3,1,0,0.
|
CALL:FDDTest:MACHs:SDTX:RBEHavior
|
Function
|
Sets/queries the
FDD Test
statDTX Reception Behavior
.
|
|
Setting
|
Range: ACK|NACK|SDTX
|
|
Query
|
Same as setting |
|
*RST Setting
|
SDTX |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:MACHs:SDTX:RBEHavior ACK"
! Sets the FDD Test statDTX Reception Behavior to Handle as ACK.
|
CALL:FDDTest:MACHs:WSIZe:TRANsmit
|
Function
|
Sets/queries the
MAC-hs Transmit Window Size
.
This setting is only applicable if
CALL:FDDTest:MACHs:HEADer
is set to
Present
.
|
|
Setting
|
Range: PDU4|PDU6|PDU8|PDU12|PDU16|PDU24|PDU32
|
|
Query
|
Same as setting |
|
*RST Setting
|
PDU16 |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:MACHs:WSIZe:TRANsmit PDU12"
! Sets the MAC-hs Transmit Window Size to 12.
|
CALL:FDDTest:OCNSource:CONFig:STATe:HSDPa
|
Function
|
Sets/queries the FDD Test HSDPA/HSPA OCNS 1 to 6 Channel Configuration States.
|
|
Setting
|
Range: 1|ON|0|OFF |
|
Query
|
Range: 0|1
|
|
*RST Setting
|
1 (ON), 1 (ON), 1 (ON), 1 (ON), 1 (ON), 1 (ON) |
|
Requirements |
Lab Application Revision: F.00 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:CONFig:STATe:HSDPa 1, 1, 1, 1, 1, 1"
|
CALL:FDDTest:OCNSource:POFFset:HSDPa
|
Function
|
Sets/queries the FDD Test HSDPA/HSPA orthogonal channel noise simulator (OCNS) 1 to 6 Power Offsets (raletive levels).
|
|
Query
|
Range: 0 to -20 dB, 9.91 E+37
Resolution: 0.01 dB
|
|
*RST Setting
|
0 dB |
|
Requirements
|
Lab Application Revision: F.00 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:OCNSource:POFFset:HSDPa 0, 0, 0, 0, 0, 0"
|
CALL:FDDTest:PICHannel[:SLEVel]
|
Function
|
The setting form of this command performs two functions: (1) sets the
FDD Test PICH Level
(see
CALL:FDDTest:PICHannel:LEVel
) and (2) sets the FDD Test PICH state to on (see
CALL:FDDTest:PICHannel:STATe
).
The query form of this command returns the
FDD Test PICH Level
.
See
FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-8.33 dB (on) |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:PICHannel -13"
! Sets the FDD Test PICH Level to -13 dB and turns its state on.
|
CALL:FDDTest:PICHannel[:SLEVel]:HSDPa
|
Function
|
The setting form of this command performs two functions: (1) sets the
HSDPA FDD Test PICH Level
(see
CALL:FDDTest:PICHannel:LEVel:HSDPa
) and (2) sets the HSDPA FDD Test PICH state to on (see
CALL:FDDTest:PICHannel:STATe:HSDPa
).
The query form of this command returns the
HSDPA FDD Test PICH Level
.
See
HSDPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-15 dB (on) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:PICHannel:HSDPa -13"
! Sets the HSDPA FDD Test PICH Level to -13 dB and turns its state on.
|
CALL:FDDTest:PICHannel[:SLEVel]:HSPA
|
Function
|
The setting form of this command performs two functions: (1) sets the
HSPA FDD Test PICH Level
(see
CALL:FDDTest:PICHannel:LEVel:HSPA
) and (2) sets the
HSPA FDD Test PICH
state to on (see
CALL:FDDTest:PICHannel:STATe:HSPA
).
The query form of this command returns the
HSPA FDD Test PICH Level
.
See
HSPA in FDD Test Operating Mode
.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-15 dB (on) |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:PICHannel:HSPA -13"
! Sets the HSPA FDD Test PICH Level to -13 dB and turns its state on.
|
CALL:FDDTest:PICHannel:DATA
|
Function
|
Sets/queries the
DL PICH Data
. The pattern can be set to either all ones or all zeros.
|
|
Setting
|
Range: ALLZERO|ALLONE
|
|
Query
|
Range: ALLZERO|ALLONE
|
|
*RST Setting
|
All Zeros |
|
Requirements
|
Test Application Revision: A.02 and above.
Lab Application Revision: A.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:PICHannel:DATA ALLONE"
! Sets the paging indicator channel data to all ones.
|
CALL:FDDTest:PICHannel:LEVel
|
Function
|
Sets/queries the
FDD Test PICH Level
. See
FDD Test Operating Mode
.
The
FDD Test PICH Level
can also be set using the
CALL:FDDTest:PICHannel[:SLEVel]
command.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-8.33 dB |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:PICH:LEVel -7"
|
CALL:FDDTest:PICHannel:LEVel:HSDPa
|
Function
|
Sets/queries the
HSDPA FDD Test PICH Level
. See
HSDPA in FDD Test Operating Mode
.
The
HSDPA FDD Test PICH Level
can also be set using the
CALL:FDDTest:PICHannel[:SLEVel]:HSDPa
command.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-15 dB |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:PICH:LEVel:HSDPa -7"
|
CALL:FDDTest:PICHannel:LEVel:HSPA
|
Function
|
Sets/queries the
HSPA FDD Test PICH Level
. See
HSPA in FDD Test Operating Mode
.
The
HSPA FDD Test PICH Level
can also be set using the
CALL:FDDTest:PICHannel[:SLEVel]:HSPA
command.
|
|
Setting
|
Range: -20.00 dB to 0 dB, 9.91 E+37
Resolution: 0.01
|
|
Query
|
Same as setting |
|
*RST Setting
|
-15 dB |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:PICH:LEVel:HSPA -7"
|
CALL:FDDTest:PICHannel:STATe
|
Function
|
Sets/queries the
FDD Test PICH
state. See
FDD Test Operating Mode
.
The
FDD Test PICH
state can also be set using the
CALL:FDDTest:PICHannel[:SLEVel]
command.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:PICHannel:STATe ON"
|
CALL:FDDTest:PICHannel:STATe:HSDPa
|
Function
|
Sets/queries the
HSDPA FDD Test PICH
state. See
HSDPA in FDD Test Operating Mode
.
The
HSDPA FDD Test PICH
state can also be set using the
CALL:FDDTest:PICHannel[:SLEVel]:HSDPa
command.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license.
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:PICHannel:STATe:HSDPa ON"
|
CALL:FDDTest:PICHannel:STATe:HSPA
|
Function
|
Sets/queries the
HSPA FDD Test PICH
state. See
HSPA in FDD Test Operating Mode
.
The
HSPA FDD Test PICH
state can also be set using the
CALL:FDDTest:PICHannel[:SLEVel]:HSPA
command.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license.
Lab Application Revision: E.00.16 and above.
|
|
Programming Example
OUTPUT 714;"CALL:FDDTest:PICHannel:STATe:HSPA ON"
|
CALL:FDDTest:TFCIndicator
|
Function
|
Sets/queries the
DL TFCI Pattern
.
|
|
Setting
|
Range: 000 to 3FF
(0 to 3 characters from the set 0123456789aAbBcCdDeEfF, up to 3FF)
|
|
Query
|
Range: "000" to "3FF"
(The return string is always 3 characters from the set 0123456789ABCDEF, up to 3FF)
|
|
*RST Setting
|
"000" |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTEST:TFCINDICATOR '2DE'"
|
CALL:FDDTest:UPLink:TFCIndicator:CONTrol:AUTO
|
Function
|
Sets/queries
Uplink TFCI Control
.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (manual) |
|
Requirements
|
Test Application Revision: A.10 and above
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTEST:UPLink:TFCIndicator:CONTrol:AUTO 1"
! Sets Uplink TFCI Control to Auto.
|
CALL:FDDTest:UPLink:TFCIndicator:MANual
|
Function
|
Sets/queries
Manual Uplink TFCI
.
This setting is only applicable when
CALL:FDDTest:UPLink:TFCIndicator:CONTrol:AUTO
is set to
OFF
(manual).
|
|
Setting
|
Range: DTCHannel (DTCH Only)|DTDCchannel (DTCH + DCCH)
|
|
Query
|
Range: DTCH|DTDC
|
|
*RST Setting
|
DTDC |
|
Requirements
|
Test Application Revision: A.10 and above
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:FDDTEST:UPLink:TFCIndicator:MANual DTCH"