CALL:MS:REPorted
Last updated: May 26, 2009
GPIB Command Conventions
CALL:MS:REPorted:AUTHenticate:FAILcause?
|
Function
|
Queries the
UE Reported Failure Cause
.
|
|
Query
|
Range: 1 to 255, 9.91E +37
|
|
*RST Setting
|
9.91E +37
|
|
Requirements |
Test Application Revision: A.03 and above.
Lab Application Revision: A.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:AUTHenticate:FAILcause?"
!Queries the authentication fail cause.
|
CALL:MS:REPorted[:CELL[1]]:ALL?
|
Function
|
Queries the UE (mobile station) reported measurement results after a successful Measurement Request (see
CALL:MS:REPorted:MEASurement:REQuest
). The measurement results returned include CPICH Ec/No, Pathloss and CPICH RSCP (see
UE Reported Measurements
for more descriptions).
After a successful Measurement Request, three comma separated results are returned in the order of CPICH Ec/No, Pathloss, and CPICH RSCP. See
CALL:MS:REPorted[:CELL[1]]:CPICh:ECNO?
,
CALL:MS:REPorted[:CELL[1]]:PATHloss?
, and
CALL:MS:REPorted[:CELL[1]]:CPICh:RSCP?
for more information.
To obtain DTCH BLER results, see
CALL:MS:REPorted[:CELL[1]]:DTCH:BLER?
.
|
|
Query
|
CPICH Ec/No:
-
Range: 0 to 49, 9.91E +37
Pathloss:
-
Range: 46 to 158 dB, 9.91E +37
-
Resolution: 1 dB
CPICH RSCP:
-
Range: 0 to 91, 9.91E +37
|
|
*RST Setting
|
9.91E +37 |
|
Requirements |
Test Application Revision: A.03 and above.
Lab Application Revision: A.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:ALL?"
|
CALL:MS:REPorted[:CELL[1]]:CPICh:ECNO?
|
Function
|
Queries the UE (mobile station) reported CPICH Ec/No measurement result which is an index to a range of Ec/No values. See
CPICH Ec/No
for the mapping of this report value to actual Ec/No range.
|
|
Query
|
Range: 0 to 49, or 9.91 E+37
|
|
*RST Setting
|
9.91E +37 |
|
Requirements |
Test Application Revision: A.03 and above.
Lab Application Revision: A.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:CPICh:ECNO?"
|
CALL:MS:REPorted[:CELL[1]]:CPICh:RSCP?
|
Function
|
Queries the UE (mobile station) reported CPICH RSCP measurement result which is an index to a range of RSCP values. See
CPICH RSCP (Received Signal Code Power)
for the mapping of this report value to actual RSCP range.
|
|
Query
|
Range: 0 to 91, or 9.91 E+37
|
|
*RST Setting
|
9.91E +37 |
|
Requirements |
Test Application Revision: A.03 and above.
Lab Application Revision: A.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:CPICh:RSCP?"
|
CALL:MS:REPorted[:CELL[1]]:PATHloss?
|
Function
|
Queries the UE (mobile station) reported Pathloss measurement result in the unit of dB. See
Pathloss
for more details.
|
|
Query
|
Range: 46 to 158 dB, or 9.91 E+37
Resolution: 1 dB
|
|
*RST Setting
|
9.91E +37 |
|
Requirements |
Test Application Revision: A.03 and above.
Lab Application Revision: A.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:PATHloss?"
|
CALL:MS:REPorted[:CELL[1]]:DTCH:BLER?
|
Function
|
Queries the UE (mobile station) reported DTCH BLER measurement result which is an index to a range of BLER values. See
DTCH BLER (Block Error Ratio) Report
for the mapping of this report value to actual BLER range.
|
|
Query
|
Range: 0 to 63, or 9.91 E+37
|
|
*RST Setting
|
9.91E +37 |
|
Requirements |
Test Application Revision: A.03 and above.
Lab Application Revision: A.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:DTCH:BLER?"
|
CALL:MS:REPorted:CELL2:ALL?
|
Function
|
Queries the cell 2 UE (mobile station) reported measurement results after a successful Measurement Request (see
CALL:MS:REPorted:MEASurement:REQuest
). The supported measurements include CPICH Ec/No, Pathloss and CPICH RSCP (see
Cell 1/Cell 2 UE Reported Measurements
for more information).
After a successful Measurement Request, three comma separated results are returned in the order of CPICH Ec/No, Pathloss, and CPICH RSCP. See
CALL:MS:REPorted[:CELL[1]]:CPICh:ECNO?
,
CALL:MS:REPorted[:CELL[1]]:PATHloss?
, and
CALL:MS:REPorted[:CELL[1]]:CPICh:RSCP?
for more information.
To obtain DTCH BLER results, see
CALL:MS:REPorted[:CELL[1]]:DTCH:BLER?
.
|
|
Query
|
CPICH Ec/No:
-
Range: 0 to 49, 9.91E +37
Pathloss:
-
Range: 46 to 158 dB, 9.91E +37
-
Resolution: 1 dB
CPICH RSCP:
-
Range: 0 to 91, 9.91E +37
|
|
*RST Setting
|
9.91E +37 |
|
Requirements |
Lab Application Revision: A.01 and above |
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:CELL2:ALL?"
|
CALL:MS:REPorted:CELL2:CPICh:ECNO?
|
Function
|
Queries the cell 2 UE (mobile station) reported CPICH Ec/No measurement result which is an index to a range of Ec/No values. See
CPICH Ec/No
for the mapping of this report value to actual Ec/No range.
|
|
Query
|
Range: 0 to 49, 9.91E +37
|
|
*RST Setting
|
9.91E +37 |
|
Requirements |
Lab Application Revision: A.01 and above |
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:CELL2:CPICh:ECNO?"
|
CALL:MS:REPorted:CELL2:CPICh:RSCP?
|
Function
|
Queries the cell 2 UE (mobile station) reported CPICH RSCP measurement result which is an index to a range of RSCP values. See
CPICH RSCP (Received Signal Code Power)
for the mapping of this report value to actual RSCP range.
|
|
Query
|
Range: 0 to 91, 9.91E +37
|
|
*RST Setting
|
9.91E +37 |
|
Requirements |
Lab Application Revision: A.01 and above |
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:CELL2:CPICh:RSCP?"
|
CALL:MS:REPorted:CELL2:OTDifference[:VALue]?
|
Function
|
Queries the UE reported
SFN-SFN Observed Time Difference (OTD)
measurement result. The type of OTD measurement performed by the UE can be queried using the
CALL:MS:REPorted:CELL2:OTDifference:TYPE?
command.
|
|
Query
|
Range: 0 to 9830399 chips, 9.91E +37
Resolution: 1 chip
|
|
*RST Setting
|
9.91E +37 |
|
Requirements |
Lab Application Revision: C.01 and above |
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:CELL2:OTDifference?"
|
CALL:MS:REPorted:CELL2:OTDifference:TYPE?
CALL:MS:REPorted:CELL2:PATHloss?
|
Function
|
Queries the cell 2 UE reported
Pathloss
measurement result.
|
|
Query
|
Range: 46 to 158 dB, 9.91E +37
Resolution: 1 dB
|
|
*RST Setting
|
9.91E +37 |
|
Requirements |
Lab Application Revision: A.01 and above |
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:CELL2:PATHloss?"
|
CALL:MS:REPorted:CLEar[:ALL]<[:SELected]|:WCDMa>
|
Function
|
Clears the UE (mobile) reported information. See
Clear UE Info
. |
|
Requirements |
Test Application Revision: A.04 and above
Lab Application Revision: A.02 and above
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:CLEar"
|
CALL:MS:REPorted:CONText:SESSion:MAXimum?
|
Function
|
Queries the UE Reported Max Context Session.
This result is extracted from the "PDCP Capability" IE in the RRC Connection Setup Complete message. If the UE did not report this, NaN is returned. This value is used to determine the MAX_CID parameter for both uplink and downlink that will be used to configure the UE.
|
|
Query
|
Range: 1 to 16383, 9.91E +37
|
|
*RST Setting
|
9.91E +37
|
|
Requirements |
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:CONText:SESSion:MAXimum?"
!Queries the UE Reported Max Context Session.
|
CALL:MS:REPorted:DOWNlink:RDDepth?
|
Function
|
Queries the UE Reported Downlink Reverse Decompression Depth.
This result is extracted from the "PDCP Capability" IE in the RRC Connection Setup Complete message. If the UE did not report this, NaN is returned.
|
|
Query
|
Range: 0 to 65535, 9.91E +37
|
|
*RST Setting
|
9.91E +37
|
|
Requirements |
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"ALL:MS:REPorted:DOWNlink:RDDepth?"
!Queries the UE Reported Downlink Reverse Decompression Depth.
|
CALL:MS:REPorted:EISV?
|
Function
|
Queries the International Mobile station Equipment Identity and Software Version number (IMEISV) reported by the UE. This result is not available when
CALL[:CELL]:EIDentity:REQuest]
is set to "IMEI". The IMEISV is composed of the following elements:
- Type Allocation Code (TAC). Its length is 8 digits;- Serial Number (SNR) is an individual serial number uniquely identifying each equipment within each TAC. Its length is 6 digits;- Software Version Number (SVN) identifies the software version number of the mobile equipment. Its length is 2 digits.
|
|
Query
|
Range: 0 to FFFFFFFFFFFFFFFF (16 chars, '0'-'9', 'A'-'F' in each char), No Results Available |
|
*RST Setting
|
No Results Available |
|
Requirements |
Lab Application Revision: E.00.34 and above.
Test Application Revision: A.13 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:EISV?"
|
CALL:MS:REPorted:EISV:SVN?
|
Function
|
Queries only the Software Version Number (SVN) element of the IMEISV reported by the UE. The SVN identifies the software version number of the mobile equipment. Its length is 2 digits.
This result is not available when
CALL[:CELL]:EIDentity:REQuest]
is set to "IMEI".
|
|
Query
|
Range: 0 to FF (2 chars, '0'-'9', 'A'-'F' in each char), No Results Available |
|
*RST Setting
|
No Results Available |
|
Requirements |
Lab Application Revision: E.00.34 and above.
Test Application Revision: A.13 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:EISV:SVN?"
|
CALL:MS:REPorted:FREQuency[:SEParation]?
|
Function
|
Queries the "Band A" transmit/receive frequency separation. The specified frequencies are as follows: 190 MHz (MHZ190, fixed frequency separation), 174.8 to 205.2 MHz (MHZV205, variable frequency separation within this range), 134 to 245.2 MHz (MHZV245, variable frequency separation within this range).
|
|
Query
|
Range: MHZ190|MHZV205|MHZV245|NONE |
|
*RST Setting
|
NONE |
|
Requirements |
Test Application Revision: A.02 and above.
Lab Application Revision: A.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:FREQuency?"
|
CALL:MS:REPorted:GSMSystem:BCHannel?
|
Function
|
Queries the
BCH ARFCN
result reported by the UE (for up to 8 GSM cells). Note that the cells are reported by the UE in order of RSSI strength. Use the
CALL:MS:REPorted:GSMSystem:CIDentity?
query to determine the
Inter-RAT Cell ID
for each of the reported cells. |
|
Query
|
Range: 0 to 1023, 9.91E+37
Resolution: 1
|
|
*RST Setting
|
9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37 |
|
Requirements |
Lab Application Revision: B.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:GSMSystem:BCHannel?"
|
CALL:MS:REPorted:GSMSystem:BSIC:VALue?
|
Function
|
Queries the
BSIC Value
corresponding to the
Inter-RAT Cell ID
reported by the UE (for up to 8 GSM cells). Note that the cells are reported by the UE in order of RSSI strength. Use the
CALL:MS:REPorted:GSMSystem:CIDentity?
query to determine the
Inter-RAT Cell ID
for each of the reported cells. |
|
Query
|
Range: 0 to 77, 9.91E+37 |
|
*RST Setting
|
9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37 |
|
Requirements |
Lab Application Revision: D.00.04 and above. |
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:GSMSystem:BSIC:VALue?"
|
CALL:MS:REPorted:GSMSystem:BSIC:VERification?
|
Function
|
Queries the
BSIC Verification
result reported by the UE (for up to 8 GSM cells). Note that the cells are reported by the UE in order of RSSI strength. Use the
CALL:MS:REPorted:GSMSystem:CIDentity?
query to determine the
Inter-RAT Cell ID
for each of the reported cells. |
|
Query
|
Range:
-
VER - Verified
-
NVER - Not Verified
-
NREP - the cell was not measured by the UE
|
|
*RST Setting
|
NREP,NREP,NREP,NREP,NREP,NREP,NREP,NREP |
|
Requirements |
Lab Application Revision: D.00.04 and above. |
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:GSMSystem:BSIC:VERification?"
|
CALL:MS:REPorted:GSMSystem:CIDentity?
|
Function
|
GSM neighbor cells are reported by the UE in order of RSSI strength. This query returns the
Inter-RAT Cell ID
for each of the cells reported by the UE, to allow you to map the UE reported results to the SIB11 GSM cell info list neighbor cells. |
|
Query
|
Range: 1 to 8, 9.91E+37
Resolution: 1
|
|
*RST Setting
|
9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37 |
|
Requirements |
Lab Application Revision: D.00.04 and above. |
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:GSMSystem:CIDentity?"
|
CALL:MS:REPorted:GSMSystem:CELLs?
|
Function
|
Queries the UE reported
Total Number of GSM Cells
. |
|
Query
|
Range: 0 to 8
Resolution: 1
|
|
*RST Setting
|
0 |
|
Requirements |
Lab Application Revision: B.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:GSMSystem:CELLs?"
|
CALL:MS:REPorted:GSMSystem:RSSI?
|
Function
|
Queries the
RSSI (GSM Cells)
result reported by the UE (for up to 8 GSM cells). Note that the cells are reported by the UE in order of RSSI strength. Use the
CALL:MS:REPorted:GSMSystem:CIDentity?
query to determine the cell ID for each of the reported cells. |
|
Query
|
Range: 0 to 63, 9.91E+37
Resolution: 1
|
|
*RST Setting
|
9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37 |
|
Requirements |
Lab Application Revision: B.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:GSMSystem:RSSI?"
|
CALL:MS:REPorted:IMEI[:SELected]?
|
Function
|
Queries the mobile reported
IMEI
.
|
|
Query
|
Range: "0" to "FFFFFFFFFFFFFF" (0 to 15 characters from the set 0123456789ABCDEF) or "" (null string)
|
|
*RST Setting
|
"" (null string)
|
|
Requirements |
Test Application Revision: A.02 and above.
Lab Application Revision: A.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:IMEI?"
|
CALL:MS:REPorted:IMSI[:SELected]?
|
Function
|
Queries the mobile reported
IMSI
.
|
|
Query
|
Range: "0" to "FFFFFFFFFFFFFF" (0 to 15 characters from the set 0123456789ABCDEF) or "" (null string)
|
|
*RST Setting
|
"" (null string) |
|
Requirements |
Test Application Revision: A.02 and above.
Lab Application Revision: A.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:IMSI?"
|
CALL:MS:REPorted:ITRFrequency:CELLs?
|
Function
|
Queries the mobile reported total number of inter frequency cells (see
Inter-Frequency Neighbor Cell Measurement Results
). |
|
Query
|
Range: 0 to 32
Resolution: 1
|
|
*RST Setting
|
0 |
|
Requirements |
Lab Application Revision: B.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:ITRFrequency:CELLs?"
|
CALL:MS:REPorted:ITRFrequency:DOWNlink:CHANnel?
|
Function
|
Queries the mobile reported DL channel for inter frequency cells 1-8 (see
Inter-Frequency Neighbor Cell Measurement Results
). |
|
Query
|
Range: 0 to 16383, 9.91E+37
Resolution: 1
|
|
*RST Setting
|
9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37 |
|
Requirements |
Lab Application Revision: B.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:ITRFrequency:DOWNlink:CHANnel?"
|
CALL:MS:REPorted:ITRFrequency:ECNO?
|
Function
|
Queries the mobile reported Ec/No for inter frequency cells 1-8 (see
Inter-Frequency Neighbor Cell Measurement Results
). |
|
Query
|
Range: 0 to 49, 9.91E+37
Resolution: 1
|
|
*RST Setting
|
9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37 |
|
Requirements |
Lab Application Revision: B.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:ITRFrequency:ECNO?"
|
CALL:MS:REPorted:ITRFrequency:PATHloss?
|
Function
|
Queries the mobile reported pathloss for inter frequency cells 1-8 (see
Inter-Frequency Neighbor Cell Measurement Results
). |
|
Query
|
Range: 46 to 158 dB, 9.91E+37
Resolution: 1 dB
|
|
*RST Setting
|
9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37 |
|
Requirements |
Lab Application Revision: B.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:ITRFrequency:PATHloss?"
|
CALL:MS:REPorted:ITRFrequency:RSCP?
|
Function
|
Queries the mobile reported RSCP for inter frequency cells 1-8 (see
Inter-Frequency Neighbor Cell Measurement Results
). |
|
Query
|
Range: 0 to 91, 9.91E+37
Resolution: 1
|
|
*RST Setting
|
9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37 |
|
Requirements |
Lab Application Revision: B.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:ITRFrequency:RSCP?"
|
CALL:MS:REPorted:ITRFrequency:RSSI?
|
Function
|
Queries the mobile reported RSSI for inter frequency cells 1-8 (see
Inter-Frequency Neighbor Cell Measurement Results
). |
|
Query
|
Range: 0 to 76, 9.91E+37
Resolution: 1
|
|
*RST Setting
|
9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37 |
|
Requirements |
Lab Application Revision: B.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:ITRFrequency:RSSI?"
|
CALL:MS:REPorted:ITRFrequency:SCODe?
|
Function
|
Queries the mobile reported scrambling code for inter frequency cells 1-8 (see
Inter-Frequency Neighbor Cell Measurement Results
). |
|
Query
|
Range: 0 to 511, 9.91E+37
Resolution: 1
|
|
*RST Setting
|
9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37,9.91E+37 |
|
Requirements |
Lab Application Revision: B.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:ITRFrequency:SCODe?"
|
CALL:MS:REPorted:MEASurement:INTernal:STATe
|
Function
|
Sets/queries the UTRA FDD UE Internal Measurement State.
This setting controls whether the UE internal measurement is requested from the UE the next time that the Send Measurement Request action is invoked.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:MEASurement:INTernal:STATe 0"
! Sets UTRA FDD UE Internal Measurement State to off.
|
CALL:MS:REPorted:MEASurement:ITAFrequency:STATe
|
Function
|
Sets/queries UTRA FDD Intra-frequency Measurement State.
This setting controls whether the intra-frequency measurement is requested from the UE the next time that the Send Measurement Request action is invoked.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:MEASurement:ITAFrequency:STATe 1"
! Sets UTRA FDD Intra-frequency Measurement State to on.
|
CALL:MS:REPorted:MEASurement:OTDifference:TYPE
|
Function
|
Sets/queries the
SFN-SFN OTD Measurement Type
performed by the UE when the
CALL:MS:REPorted:MEASurement:REQuest
command is sent.
|
|
Setting |
Range: NONE|TYPE1|TYPE2 |
|
Query |
Same as setting. |
|
*RST Setting |
NONE |
|
Requirements |
Lab Application Revision: C.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:MEASurement:OTDifference:TYPE TYPE2"
! Sets SFN-SFN OTD Measurement Type to Type 2.
|
CALL:MS:REPorted:MEASurement:QUALity:STATe
|
Function
|
Sets/queries UTRA FDD Quality Measurement State.
This setting controls whether the quality measurement is requested from the UE the next time that the Send Measurement Request action is invoked. |
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:MEASurement:QUALity:STATe 0"
! Sets UTRA FDD Quality Measurement State to off.
|
CALL:MS:REPorted:MEASurement:REQuest
CALL:MS:REPorted:MEASurement:TYPe
|
Function
|
Sets/queries the
Report Measurement Type
, which determines which measurements are performed by the UE when the
CALL:MS:REPorted:MEASurement:REQuest
command is sent. |
|
Setting |
Range: ALL|INTRAFREQ|QUAL
|
|
Query
|
Same as setting. |
|
*RST Setting
|
INTRAFREQ |
|
Requirements |
Test Application Revision: A.05 and above.
Lab Application Revision: B.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:MEASurement:TYPe ALL"
|
CALL:MS:REPorted:ONUMber<[:SELected]|WCDMa>?
|
Function
|
Queries the
Called Party Number
.
|
|
Query
|
Range: 0 to 20 characters enclosed by double quotes, from the set 0123456789.*# or "Emergency Call" or "" (null string).
|
|
*RST Setting
|
"" (null string) |
|
Requirements |
Lab Application Revision: C.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:ONUMber?"
|
CALL:MS:REPorted:PCLass[:SELected]?
|
Function
|
Queries the mobile reported
Power Class
.
|
|
Query
|
Range: 1, 2, 3, 4, 9.91E+37
|
|
*RST Setting
|
9.91E+37 |
|
Requirements |
Test Application Revision: A.02 and above.
Lab Application Revision: A.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:PCLass?"
|
CALL:MS:REPorted:PRAChannel:SIGnature?
|
Function
|
Queries the
Detected PRACH Signature
.
|
|
Query
|
Range: 0 to 15, 9.91E+37
|
|
*RST Setting
|
9.91E+37
|
|
Requirements |
Lab Application Revision: A.02 and above |
|
Programming Example
OUTPUT 714;"CALL:MS:REPorted:PRAChannel:SIGnature?"
|
CALL:MS:REPorted:TRANsmit:POWer?
|
Function
|
Queries the UTRA FDD UE Transmitted Power as an index.
The mapping of the reported value to actual UE transmission power range is provided in 3GPP TS 25.133 V7.d.0 section 9.1.6.2, "UE transmitted power measurement report mapping".
|
|
Query
|
Range: 0 to 104
|
|
Requirements |
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CCALL:MS:REPorted:TRANsmit:POWer?"
!Queries the the UTRA FDD UE Transmitted Power.
|
|
|