CALL:RESelection
Last updated: May 26, 2009
This section is only applicable to the lab application.
GPIB Command Conventions
CALL[:CELL]:RESelection:GSM:SHCS[:SVALue]
|
Function
|
Sets/queries the Shcs,rat (GSM), and sets its state to ON.
This setting controls the Shcs,rat parameter in SIB3. This parameter determines the serving cell RSCP level at which the UE does not need to make inter-RAT measurements.
This setting only affects SIB3 if both the "Inter-RAT (GSM) and "Shcs,rat (GSM) State" settings are On.
|
|
Setting
|
Range: - 105 to 91 (in increments of 2)
|
|
Query
|
Range: - 105 to 91 (in increments of 2)
|
|
*RST Setting
|
0 |
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:RESelection:GSM:SHCS 0"
!Sets the Shcs,rat (GSM) to 0 and turns it on.
|
CALL[:CELL]:RESelection:GSM:SHCS:STATe
|
Function
|
Sets/queries the Shcs,rat (GSM) State.
This setting controls whether the Shcs,rat (GSM) parameter will be included in SIB3.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0 |
|
*RST Setting |
0 (off) |
|
Requirements |
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:RESelection:GSM:SHCS:STATe OFF"
! Sets the Shcs,rat (GSM) State to Off.
|
CALL[:CELL]:RESelection:GSM:SHCS:VALue
|
Function
|
Sets/queries the Shcs,rat (GSM).
This setting controls the Shcs,rat parameter in SIB3. This parameter determines the serving cell RSCP level at which the UE does not need to make inter-RAT measurements.
This setting only affects SIB3 if both the "Inter-RAT (GSM) and "Shcs,rat (GSM) State" settings are On.
|
|
Setting
|
Range: - 105 to 91 (in increments of 2)
|
|
Query
|
Range: - 105 to 91 (in increments of 2)
|
|
*RST Setting
|
0 |
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:RESelection:GSM:SHCS:VALue 0"
!Sets the Shcs,rat (GSM) to 0.
|
CALL[:CELL]:RESelection:GSM:SLIMit
|
Function
|
Sets/queries the Slimit,searchrat (GSM).
This parameter controls the Slimit,searchrat (GSM) parameter in SIB3.
|
|
Setting
|
Range: -32 to 20 (in increments of 2)
|
|
Query
|
Range: -32 to 20 (in increments of 2)
|
|
*RST Setting
|
0 |
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:RESelection:GSM:SLIMit"
!Sets the Slimit,searchrat (GSM) to 0.
|
CALL[:CELL]:RESelection:GSM:SSEarch
|
Function
|
Sets/queries the Ssearch,rat (GSM).
This setting controls the Ssearch,rat parameter in SIB3. This broadcast parameter determines the serving cell CPICH Ec/No level at which the UE does not need to make inter-RAT measurements.
|
|
Setting
|
Range: -32 to 20 (in increments of 2)
|
|
Query
|
Range: -32 to 20 (in increments of 2)
|
|
*RST Setting
|
0 |
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:RESelection:GSM:SSEarch 0"
!Sets the Ssearch,rat (GSM) to 0.
|
CALL[:CELL]:RESelection:GSM:STATe
|
Function
|
Sets/queries the Inter-RAT (GSM) 'S' Parameters State.
This setting controls whether any of the inter-RAT cell selection/reselection parameters are included in SIB3.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0 |
|
*RST Setting |
0 (off) |
|
Requirements |
Lab Application Revision: C.03 and above |
|
Programming Example
OUTPUT 714;"CALL:RESelection:GSM:STATe OFF"
! Sets Inter-RAT (GSM) 'S' Parameters State to Off.
|
CALL[:CELL]:RESelection:HYSTeresis[1]
|
Function
|
Sets/queries
Hysteresis 1 (Qhyst1)
. This setting is only applicable when
Quality Measure
is set to
CPICH RSCP
.
This setting can only be changed when call status is
Idle
. If
BCCH Update Page
is set to
Auto
and you change this setting while your UE is camped to the test set, the test set performs a
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
. If
BCCH Update Page
is set to
Inhibit
(the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see
BCCH Update Page
for more details).
|
|
Setting
|
Range: 0 dB to +40 dB
Resolution: 1 dB
|
|
Query
|
Same as setting |
|
*RST Setting
|
0 dB |
|
Requirements
|
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:RESelection:HYSTeresis 3"
! Sets the Hysteresis 1 (Qhyst1) to 3 dB.
|
CALL[:CELL]:RESelection:HYSTeresis2
|
Function
|
Sets/queries
Hysteresis 2 (Qhyst2)
. This setting is only applicable when
Quality Measure
is set to
CPICH Ec/N0
.
This setting can only be changed when call status is
Idle
. If
BCCH Update Page
is set to
Auto
and you change this setting while your UE is camped to the test set, the test set performs a
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
. If
BCCH Update Page
is set to
Inhibit
(the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see
BCCH Update Page
for more details).
|
|
Setting
|
Range: 0 dB to +40 dB
Resolution: 1 dB
|
|
Query
|
Same as setting |
|
*RST Setting
|
0 dB |
|
Requirements
|
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:RESelection:HYSTeresis2 3"
! Sets Hysteresis 2 (Qhyst2) to 3 dB.
|
CALL[:CELL]:RESelection:QUALity:LMINimum
|
Function
|
Sets/queries the
Minimum Required Quality Level (Qqualmin)
.
This setting can only be changed when call status is
Idle
. If
BCCH Update Page
is set to
Auto
and you change this setting while your UE is camped to the test set, the test set performs a
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
. If
BCCH Update Page
is set to
Inhibit
(the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see
BCCH Update Page
for more details).
|
|
Setting
|
Range: -24 dB to 0 dB
Resolution: 1 dB
|
|
Query
|
Same as setting |
|
*RST Setting
|
-24 dB |
|
Requirements
|
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:RESelection:QUALity:LMINimum -10"
! Sets Minimum Required Quality Level (Qqualmin) to -10 dB.
|
CALL[:CELL]:RESelection:QUALity:MEASure
|
Function
|
Sets/queries the
Quality Measure
.
This setting can only be changed when call status is
Idle
. If
BCCH Update Page
is set to
Auto
and you change this setting while your UE is camped to the test set, the test set performs a
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
. If
BCCH Update Page
is set to
Inhibit
(the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see
BCCH Update Page
for more details).
|
|
Setting
|
Range:
-
ECN0 - sets
Quality Measure (Qmeas)
to CPICH Ec/N0
-
ECNO - sets
Quality Measure (Qmeas)
to CPICH Ec/N0
-
RSCP - sets
Quality Measure (Qmeas)
to CPICH RSCP
|
|
Query
|
Range: RCSP|ECN0
|
|
*RST Setting
|
ECN0 |
|
Requirements
|
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:RESelection:QUALity:MEASure RSCP"
! Sets Quality Measure (Qmeas) to CPICH RSCP.
|
CALL[:CELL]:RESelection:RLMinimum
|
Function
|
Sets/queries the
Minimum Required Rx Level (Qrxlevmin)
.
This setting can only be changed when call status is
Idle
. If
BCCH Update Page
is set to
Auto
and you change this setting while your UE is camped to the test set, the test set performs a
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
. If
BCCH Update Page
is set to
Inhibit
(the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see
BCCH Update Page
for more details).
|
|
Setting
|
Range: -115 dBm to -25 dBm
Resolution: 1 dB
|
|
Query
|
Same as setting |
|
*RST Setting
|
-115 dBm |
|
Requirements
|
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:RESelection:RLMinimum -100"
! Sets Minimum Required Rx Level (Qrxlevmin) to -100 dBm.
|
CALL[:CELL]:RESelection:TIMer
|
Function
|
Sets/queries the
Timer (Treselection)
.
This setting can only be changed when call status is
Idle
. If
BCCH Update Page
is set to
Auto
and you change this setting while your UE is camped to the test set, the test set performs a
Broadcast Channel (BCCH) Update Procedure (SIB Contents)
. If
BCCH Update Page
is set to
Inhibit
(the default value) and you change this setting while your UE is camped to the test set, you must force your UE to re-read the BCCH to observe the change (see
BCCH Update Page
for more details).
|
|
Setting
|
Range: 0 s to 31 s
Resolution: 1 s
|
|
Query
|
Same as setting |
|
*RST Setting
|
0 s |
|
Requirements
|
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:RESelection:TIMer 10"
! Sets Timer (Treselection) to 10 seconds.
|
|
|