CALL:STATus

Last updated: September 2, 2009

   
NOTE
The CALL:STATus commands are query only. They return values that indicate the test set's actual hardware settings. Actual hardware settings can differ from settings the user has entered, most frequently due to an error condition. When no error conditions exist, the commands used to enter values return the same results as the commands used to query actual hardware settings. For example, "CALL:AWGNoise:POWer?" returns the same value as "CALL:STATus:AWGNoise:POWer?" when no error conditions exist.

   

GPIB Command Conventions

CALL:STATus[:STATe][:VOICe]?

Function

Queries the status of the call. See Call Connection State .

Query

Range: CALL|CONN|HAND|IDLE|PAG|REG|REL|SREQ

Only IDLE is returned in FDD Test operating mode.

*RST Setting

IDLE

Requirements

Test or Lab Application Revision: A.01 and above

Test Application Revision: A.05 and above added CALL

Lab Application Revision: B.01 and above added CALL

Programming Example

 
OUTPUT 714;"CALL:STATus?"
! Returns the current call processing state.

CALL:STATus:AICHannel[:CELL][:LEVel]?

Function

Queries the current level of the acquisition indicator channel. This query is not applicable to FDD Test operating mode. See Downlink Code Channel Information .

Query

Range: -20.00 to 0 dB, 9.91 E+37

Resolution: 0.01 dB

*RST Setting

-9.9 dB

Requirements

Test Application Revision: A.02 and above

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:AICHannel?"

CALL:STATus:AICHannel[:CELL]:STATe?

Function

Queries the current state of the acquisition indicator channel. This query is not applicable to FDD Test operating mode. See Downlink Code Channel Information .

Query

Range: 0|1

*RST Setting

1 (on)

Requirements

Test Application Revision: A.02 and above

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:AICHannel:STATe?"

CALL:STATus[:GMM]:ATTached:STATe?

Function

Queries the attached state of the UE. See GMM State .

Query

Range:

  • ATT - attached
  • ATTINC - attach incomplete
  • DET - detached
  • NONE

*RST Setting

NONE

Requirements

Test Application Revision: A.08.20 and above

Lab Application Revision: A.02 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:ATTached:STATe?"

CALL:STATus:AWGNoise[:INTernal]:POWer[:AMPLitude]([:SELected]|:FDD)?

Function

Queries the current power level of the additive white Gaussian noise (AWGN) source. AWGN power level is set using the CALL:AWGNoise commands.

The optional [:SELected] mnemonic in this command specifies that the AWGN power level being queried applies to the current system type (FDD is currently the only system type available).

See Cell Power and AWGN Power for more information about desired versus current power levels.

Query

Range:

Resolution: 0.01 dB

*RST Setting

9.91 E+37 (NAN)

Requirements

Test or Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:AWGNoise:POWer?" 
!Queries the current AWGN power.

CALL:STATus:AWGNoise[:INTernal]:POWer:STATe?

Function

Queries the current on/off state of the additive white Gaussian noise (AWGN) source. AWGN power level on/off state is set using the CALL:AWGNoise commands.

See Cell Power and AWGN Power for more information about desired versus current power levels.

Query

Range: 1|0

*RST Setting

0 (off)

Requirements

Test or Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:AWGNoise:POWer:STATe?"

CALL:STATus:CCPChannel:PRIMary[:CELL[1]][:LEVel]?

Function

Queries the current level of the primary common control physical channel. See Downlink Code Channel Information .

Query

Range: -20.00 to 0 dB, 9.91 E+37

Resolution: 0.01 dB

*RST Setting

-5.3 dB

Requirements

Test or Lab Application Revision: A.01 and above.

Test Application Revision A.06 changed *RST Setting to -5.3 dB.

Lab Application Revision C.01 changed *RST Setting to -5.3 dB.

Programming Example

 
OUTPUT 714;"CALL:STATus:CCPChannel:PRIMary?"

CALL:STATus:CCPChannel:PRIMary[:CELL[1]]:STATe?

Function

Queries the current state of the primary common control physical channel. See Downlink Code Channel Information .

Query

Range: 0|1

*RST Setting

1 (on)

Requirements

Test or Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CCPChannel:PRIMary:STATe?"

CALL:STATus:CCPChannel:PRIMary:CELL2[:LEVel]?

Function

Queries the current level of the cell 2 primary common control physical channel. See Cell 2 Overview and Downlink Code Channel Information .

Query

Range: -20.00 to 0 dB, 9.91 E+37

Resolution: 0.01 dB

*RST Setting

9.91E+37

Requirements

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CCPChannel:PRIMary:CELL2?"

CALL:STATus:CCPChannel:PRIMary:CELL2:STATe?

Function

Queries the current state of the cell 2 primary common control physical channel. See Cell 2 Overview and Downlink Code Channel Information .

Query

Range: 0|1

*RST Setting

0 (off)

Requirements

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CCPChannel:PRIMary:CELL2:STATe?"

CALL:STATus:CCPChannel:SECondary[:CELL][:LEVel]?

Function

Queries the current level of the secondary common control physical channel. See Downlink Code Channel Information .

Query

Range: -20.00 to 0 dB, 9.91 E+37

Resolution: 0.01 dB

*RST Setting

-10.3 dB

Requirements

Test Application Revision: A.02 and above

Lab Application Revision: A.01 and above

Test Application Revision A.06 changed *RST Setting to -10.3 dB.

Lab Application Revision C.01 changed *RST Setting to -10.3 dB.

Programming Example

 
OUTPUT 714;"CALL:STATus:CCPChannel:SECondary?"

CALL:STATus:CCPChannel:SECondary[:CELL]:STATe?

Function

Queries the current state of the secondary common control physical channel. See Downlink Code Channel Information .

Query

Range: 0|1

*RST Setting

1 (on)

Requirements

Test Application Revision: A.02 and above

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CCPChannel:SECondary:STATe?"

CALL:STATus:CELL[1]:POWer[:AMPLitude]?

Function

Queries the current cell power level. Cell power is set using the CALL:POWer commands.

See Cell Power and AWGN Power for more information about desired versus current power levels.

Query

Range:

Resolution: 0.01 dB

*RST Setting

-75.00 dBm

Requirements

Test or Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CELL:POWer:AMPLitude?" 

CALL:STATus:CELL[1]:POWer:STATe?

Function

Queries the current state of the cell power setting. Cell power state is set using the CALL:POWer commands.

See Cell Power and AWGN Power for more information about desired versus current power levels.

Query

Range: 1|0

*RST Setting

1 (on)

Requirements

Test or Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CELL:POWer:STATe?"

CALL:STATus:CELL:SYSTem[:TYPE]?

Function

Queries the current system type that the test set is currently emulating.

When the test set is in active cell operating mode (see CALL:OPERating ) the current system type is selected by the CALL:SYSTem command. (Active cell operating mode is not available in the initial W-CDMA test application release.)

When the test set is in any test mode operating mode (see CALL:OPERating ) or CW operating mode, this command will return the corresponding system type.

Query

Range: FDD|CW

*RST Setting

FDD

Requirements

Test or Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CELL:SYSTem?"

CALL:STATus:CELL2:POWer[:AMPLitude]?

Function

Queries the current cell 2 power level. (See Cell 2 Overview ).

Query

Range:

  • -165 dBm/3.84 MHz to +37dBm/3.84 MHz, 9.91 E+37
    (-115 dBm/3.84 MHz to -13 dBm/3.84 MHz actual hardware range with amplitude offset = 0)

    The actual power range is defined by adding the value of the associated amplitude offset to the range above. For example, if amplitude offset is -3.5 dB, then the power range will be -118.5 dBm/3.84 MHz to -16.5 dBm/3.84 MHz.

Resolution: 0.01 dBm/3.84 MHz

*RST Setting

9.91E+37

Requirements

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CELL2:POWer?" 

CALL:STATus:CELL2:POWer:STATe?

Function

Queries the current state of the cell 2 power setting. (See Cell 2 Overview ).

Query

Range: 1|0

*RST Setting

0 (off)

Requirements

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CELL2:POWer:STATe?"

CALL:STATus:COMPressed:STATe?

Function

Queries Compressed Mode State/Overall CM (see Enabling/Disabling Compressed Mode ).

Query

Range: 1|0

*RST Setting

0 (off)

Requirements

Lab Application Revision: B.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:COMPressed:STATe?"

CALL:STATus:COMPressed:TGPSequence:ALL:STATe?

Function

Queries which TGPSs are currently active. The first num value corresponds to the First TGPS , the second num value corresponds to the Second TGPS , etc. See Enabling/Disabling Compressed Mode .

Query

Range: 1|0

*RST Setting

0, 0, 0, 0

Requirements

Lab Application Revision: D.00.04 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:COMPressed:TGPSequence:ALL:STATe?"

CALL:STATus:CPC:DRX:ACTivated?

Function

Queries the Current DRX Activated State.

Query

Range: 1|0

*RST Setting

0 (off)

Requirements

Lab Application Revision: F.00.19 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CPC:DRX:ACTivated?"

CALL:STATus:CPC:DTX:ACTivated?

Function

Queries the current DTX Activated State.

Query

Range: 1|0

*RST Setting

0 (off)

Requirements

Lab Application Revision: F.00.19 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CPC:DTX:ACTivated?"

CALL:STATus:CPC:DTX:TRANsition:C1Cycle2:COUNt?

Function

Queries the number of DTX Cycle 1 to Cycle 2 transitions.

Query

Range: 0 to 150,000, 9.91 E+37

Resolution: 0.01

*RST Setting

9.91 E+37

Requirements

Lab Application Revision: F.00.19 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CPC:DTX:TRANsition:C1Cycle2:COUNt?" 

CALL:STATus:CPC:HLESs:ACTivated?

Function

Queries the Current HS-SCCH-less Activated State.

Query

Range: 1|0

*RST Setting

0 (off)

Requirements

Lab Application Revision: F.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CPC:HLESs:ACTivated?"

CALL:STATus:CPC:HLESs:TBSize?

Function

Queries the TB size that is being used for HS-SCCH-less operation.

Query

Range: 137 to 1483 bits, 9.91 E+37

Resolution: 0.01

*RST Setting

9.91 E+37

Requirements

Lab Application Revision: F.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CPC:HLESs:TBSize?" 

CALL:STATus:CPC:MS:DPCChannel:BURSt[1]:COUNt?

Function

Queries the Number of DPCCH Burst 1 Transmissions.

Query

Range: 0 to 150,000, 9.91 E+37

Resolution: 0.01

*RST Setting

9.91 E+37

Requirements

Lab Application Revision: F.00.19 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CPC:MS:DPCChannel:BURSt:COUNt?" 

CALL:STATus:CPC:MS:DPCChannel:BURSt2:COUNt?

Function

Queries the Number of DPCCH Burst 2 Transmissions.

Query

Range: 0 to 150,000, 9.91 E+37

Resolution: 0.01

*RST Setting

9.91 E+37

Requirements

Lab Application Revision: F.00.19 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CPC:MS:DPCChannel:BURSt2:COUNt?" 

CALL:STATus:CPC:MS:DRX:CONFigured?

Function

Queries whether the DL DRX configuration has been successfully configured in the UE.

This result is only available in Active Cell mode.

Query

Range: 1|0

*RST Setting

0 (false)

Requirements

Lab Application Revision: F.00.19 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CPC:MS:DRX:CONFigured?"

CALL:STATus:CPC:MS:DTX:CONFigured?

Function

Queries whether UL DTX configuration has been successfully configured in the UE.

Query

Range: 1|0

*RST Setting

0 (false)

Requirements

Lab Application Revision: F.00.19 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CPC:MS:DTX:CONFigured?"

CALL:STATus:CPC:MS:HLESs:CONFigured?

Function

Queries whether HS-SCCH-less configuration has been successfully configured in the UE..

Query

Range: 1|0

*RST Setting

0 (false)

Requirements

Lab Application Revision: F.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CPC:MS:HLESs:CONFigured?"

CALL:STATus:CPIChannel[:CELL[1]][:LEVel]?

Function

Queries the current common pilot channel's power. See Downlink Code Channel Information .

Query

Range: -20.00 to 0 dB, 9.91 E+37

Resolution: 0.01 dB

*RST Setting

-3.3 dB

Requirements

Test or Lab Application Revision: A.01 and above

Test Application Revision A.06 changed *RST Setting to -3.3 dB.

Lab Application Revision C.01 changed *RST Setting to -3.3 dB.

Programming Example

 
OUTPUT 714;"CALL:STATus:CPIChannel?" 

CALL:STATus:CPIChannel[:CELL[1]]:POWer[:AMPLitude]?

Function

Queries the current cell1 CPICH power level in dBm (current Cell Power + current CPICH level). See Downlink Code Channel Information .

Query

Range: -165.00 dBm to +37.00 dBm, 9.91 E+37

Resolution: 0.01 dB

*RST Setting

-78.3 dBm

Requirements

Test or Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CPIChannel:POWer?" 

CALL:STATus:CPIChannel[:CELL[1]]:STATe?

Function

Queries the current state of the common pilot channel. See Downlink Code Channel Information .

Query

Range: 1|0

*RST Setting

1 (on)

Requirements

Test or Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CPIChannel:STATe?"

CALL:STATus:CPIChannel:CELL2[:LEVel]?

Function

Queries the current cell 2 common pilot channel's power. See Cell 2 Overview and Downlink Code Channel Information .

Query

Range: -20.00 to 0 dB, 9.91 E+37

Resolution: 0.01 dB

*RST Setting

9.91E+37

Requirements

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CPIChannel:CELL2?" 

CALL:STATus:CPIChannel:CELL2:POWer[:AMPLitude]?

Function

Queries the current cell2 CPICH power level in dBm (current Cell 2 Power + current Cell 2 CPICH level). See Cell 2 Overview and Downlink Code Channel Information .

Query

Range: -165.00 dBm to +37.00 dBm, 9.91 E+37

Resolution: 0.01 dB

*RST Setting

9.91 E+37

Requirements

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CPIChannel:CELL2:POWer?" 

CALL:STATus:CPIChannel:CELL2:STATe?

Function

Queries the current state of the cell 2 common pilot channel. See Cell 2 Overview and Downlink Code Channel Information .

Query

Range: 1|0

*RST Setting

0 (off)

Requirements

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:CPIChannel:CELL2:STATe?"

CALL:STATus[:STATe]:DATA?

Function

Queries the status of the data connection. See Data Connection State .

Query

Range: ATTG|DET|IDLE|OFF|PDPAG|PDP|PDPD

*RST Setting

OFF

Requirements

Test Application Revision: A.03 and above

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:DATA?"
! Returns the current data connection state.

CALL:STATus:DPCHannel[:LEVel]?

Function

Queries the current dedicated physical channel's power. See Downlink Code Channel Information .

Query

Range: -20.00 to 0 dB, 9.91 E+37

Resolution: 0.01 dB

*RST Setting

9.91 E+37

Requirements

Test or Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:DPCHannel?" 

CALL:STATus:DPCHannel:STATe?

Function

Queries the current state of the dedicated physical channel. See Downlink Code Channel Information .

Query

Range: 1|0

*RST Setting

0 (off)

Requirements

Test or Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:DPCHannel:STATe?"

CALL:STATus:DPCHannel:CELL2[:LEVel]?

Function

Queries the current cell 2 dedicated physical channel's power. See Cell 2 Overview and Downlink Code Channel Information .

Query

Range: -20.00 to 0 dB, 9.91 E+37

Resolution: 0.01 dB

*RST Setting

9.91 E+37

Requirements

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:DPCHannel:CELL2?" 

CALL:STATus:DPCHannel:CELL2:STATe?

Function

Queries the current state of the cell 2 dedicated physical channel. See Cell 2 Overview and Downlink Code Channel Information .

Query

Range: 1|0

*RST Setting

0 (off)

Requirements

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:DPCHannel:CELL2:STATe?"

CALL:STATus:DPCHannel[:CELL]:CURCbeta?

Function

Queries the current power gain of the dedicated physical control channel (DPCCH) see Uplink DPCH Bc/Bd Control .

Query

Range: 1 to 15

Resolution: 1

*RST Setting

8

Requirements

Test Application Revision: A.03 and above

Lab Application Revision: A.01 and above

Test Application Revision A.11 and Lab Application Revisions D.02 and E.00, range is 1 to 15 (vs. 2 to 15)

Programming Example

 
OUTPUT 714;"CALL:STATus:DPCHannel:CURCbeta?"

CALL:STATus:DPCHannel[:CELL]:CURDbeta?

Function

Queries the current power gain of the dedicated physical data channel (DPDCH) see Uplink DPCH Bc/Bd Control .

Query

Range: 0 to 15

Resolution: 1

*RST Setting

15

Requirements

Test Application Revision: A.03 and above

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:DPCHannel:CURDbeta?"

CALL:STATus:DPCHannel:OFFSet?

Function

Queries the Current DPCH Offset .

Query

Range: 0 to 2560

Resolution: 256

*RST Setting

0 chips

Requirements

Test Application Revision: A.09 and above

Lab Application Revision: C.04 and above

Lab Application Revision: D.00 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:DPCHannel:OFFSet?"

CALL:STATus:EAGChannel[:CELL][:LEVel]?

Function

Queries the current level of the E-AGCH. See Downlink Code Channel Information .

Query

Range: -20.00 dB to 0.00 dB, 9.91E+37

Resolution: 0.01 dB

*RST Setting

9.91E+37

Requirements

Test Application Revision: A.12 and above, with the required feature license

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:EAGChannel?"

CALL:STATus:EAGChannel[:CELL]:STATe?

Function

Queries the current state of the E-AGCH. See Downlink Code Channel Information .

Query

Range: 1|0

*RST Setting

0 (off)

Requirements

Test Application Revision: A.12 and above, with the required feature license

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:EAGChannel:STATe?"

CALL:STATus:EDCHannel[:CELL]:BLOCk:SIZE[:LAST]?

Function

Queries the Last Block Size .

Query

Range: 0 to 20000 bits, 9.91E+37

Resolution: 1 bit

*RST Setting

9.91E+37

Requirements

Test Application Revision: A.12 and above, with the required feature license

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:EDCHannel:BLOCk:SIZE?"

CALL:STATus:EDCHannel[:CELL]:BLOCk:SIZE:AVERage?

Function

Queries the Avg Block Size .

Query

Range: 0 to 20000 bits, 9.91E+37

Resolution: 1 bit

*RST Setting

9.91E+37

Requirements

Test Application Revision: A.12 and above, with the required feature license

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:EDCHannel:BLOCk:SIZE:AVERage?"

CALL:STATus:EDCHannel[:CELL]:BLOCk:SIZE:MAXimum?

Function

Queries the Max Block Size .

Query

Range: 0 to 20000 bits, 9.91E+37

Resolution: 1 bit

*RST Setting

9.91E+37

Requirements

Test Application Revision: A.12 and above, with the required feature license

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:EDCHannel:BLOCk:SIZE:MAXimum?"

CALL:STATus:EDCHannel[:CELL]:BLOCk:SIZE:MINimum?

Function

Queries the Min Block Size .

Query

Range: 0 to 20000 bits, 9.91E+37

Resolution: 1 bit

*RST Setting

9.91E+37

Requirements

Test Application Revision: A.12 and above, with the required feature license

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:EDCHannel:BLOCk:SIZE:MINimum?"

CALL:STATus:EDCHannel[:CELL]:IBTHroughput?

Function

Queries the Throughput .

Query

Range: 0 to 5760 kbps, 9.91E+37

Resolution: 1 kbps

*RST Setting

9.91E+37

Requirements

Test Application Revision: A.12 and above, with the required feature license

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:EDCHannel:IBTHroughput?"

CALL:STATus:EHIChannel[:CELL][:LEVel]?

Function

Queries the current level of the E-HICH. See Downlink Code Channel Information .

Query

Range: -20.00 dB to 0.00 dB, 9.91E+37

Resolution: 0.01 dB

*RST Setting

9.91E+37

Requirements

Test Application Revision: A.12 and above, with the required feature license

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:EHIChannel?"

CALL:STATus:EHIChannel[:CELL]:STATe?

Function

Queries the current state of the E-HICH. See Downlink Code Channel Information .

Query

Range: 1|0

*RST Setting

0 (off)

Requirements

Test Application Revision: A.12 and above, with the required feature license

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:EHIChannel:STATe?"

CALL:STATus:EHIChannel[:CELL]:ACK[:COUNt]?

Function

Queries the ACKs Transmitted .

Query

Range: 0 to 150000, 9.91E+37

Resolution: 1

*RST Setting

9.91E+37

Requirements

Test Application Revision: A.12 and above, with the required feature license

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:EHIChannel:ACK?"

CALL:STATus:EHIChannel[:CELL]:NACK[:COUNt]?

Function

Queries the ACKs Transmitted .

Query

Range: 0 to 150000, 9.91E+37

Resolution: 1

*RST Setting

9.91E+37

Requirements

Test Application Revision: A.12 and above, with the required feature license

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:EHIChannel:NACK?"

CALL:STATus:ERGChannel[:CELL][:LEVel]?

Function

Queries the current level of the E-RGCH. See Downlink Code Channel Information .

Query

Range: -20.00 dB to 0.00 dB, 9.91E+37

Resolution: 0.01 dB

*RST Setting

9.91E+37

Requirements

Test Application Revision: A.12 and above, with the required feature license

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:ERGChannel?"

CALL:STATus:ERGChannel[:CELL]:STATe?

Function

Queries the current state of the E-RGCH. See Downlink Code Channel Information .

Query

Range: 1|0

*RST Setting

0 (off)

Requirements

Test Application Revision: A.12 and above, with the required feature license

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:ERGChannel:STATe?"

CALL:STATus:ETFCi[:LAST]?

Function

Queries the Last Received E-TFCI .

Query

Range: 0 to 127, 9.91E+37

Resolution: 1

*RST Setting

9.91E+37

Requirements

Test Application Revision: A.12 and above, with the required feature license

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:ETFCi?"

CALL:STATus:ETFCi:RECord[:STATe]?

Function

Queries the E-TFCI Recording State .

Query

Range: REC(recording)|IDLE

*RST Setting

IDLE

Requirements

Test Application Revision: A.12 and above, with the required feature license

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:ETFCi:RECord?"

CALL:STATus:ETFCi:RECord:ALL?

Function

Queries the Recorded E-TFCI Values . This result always returns 50 comma-separated numbers; Number of E-TFCI Results Recorded E-TFCI values, followed by NANs (9.91E+37).

Query

Range: 0 to 127, 9.91E+37

Resolution: 1

*RST Setting

9.91E+37

Requirements

Test Application Revision: A.12 and above, with the required feature license

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:ETFCi:RECord:ALL?"

CALL:STATus:ETFCi:RECord:COUNt?

Function

Queries the Number of E-TFCI Results Recorded .

Query

Range: 0 to 50

Resolution: 1

*RST Setting

0

Requirements

Test Application Revision: A.12 and above, with the required feature license

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:ETFCi:RECord:COUNt?"

CALL:STATus:ETFCi:RECord:FRAMe:INDicator?

Function

Queries the Recorded E-TFCI Integrity Indicators.

Query

Range: An array of 50 values, each element of the array has the following range:

- NONE (No value recorded)
- GCRC (Good CRC)
- BCRC (Bad CRC)
- DTX (EDPDCH subframe is DTX'd for an E-DCH TTI transmission)

*RST Setting

NONE (No value recorded)

Requirements

Lab Application Revision: E.00.34 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:ETFCi:RECord:FRAMe:INDicator?"

CALL:STATus:FBINdicator?

Function

Queries the Current Info, Frequency Band .

Query

Range: BAND1|BAND2|BAND3|BAND4|BAND5|BAND6|BAND7|BAND8|BAND9|BAND10|
BAND11|BAND12|BAND13|BAND14

*RST Setting

BAND1

Requirements

Test Application Revision: A.08 and above.

Test Application Revision A.09, added BAND8 and BAND9.

Lab Application Revision: C.03 and above.

Lab Application Revision C.04 and D.00, added BAND8 and BAND9.

Test Application Revision A.10.01 and Lab Application Revision D.01.01 added BAND7

Test Application Revision A.11 and Lab Application Revisions D.02 and E.00, added BAND10

Test Application Revision A.13 and Lab Application Revision E.00.34, added BAND11

Test Application Revision A.14 and Lab Application Revision F.00, added BAND12, BAND13, BAND14

Programming Example

 
OUTPUT 714;"CALL:STATus:FBINdicator?"

CALL:STATus:HSDSchannel:TBSize?

Function

Queries the Current Test Mode Transport Block Size .

Query

Range: 120 to 42192

Resolution: 1

Requirements

Test Application Revision: A.09 and above, with the required feature license

Lab Application Revision: C.04 and above

Lab Application Revision: D.00 and above

Test Application Revision A.14 and Lab Application Revision F.00 and above, range extended.

Programming Example

 
OUTPUT 714;"CALL:STATus:HSDSchannel:TBSize?" 

CALL:STATus:HSDSchannel:TBSize:PSData?

Function

Queries the Current Test Mode Transport Block Size .

Query

Range: 137 to 27952

Resolution: 1

*RST Setting

4664

Requirements

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:HSDSchannel:TBSize:PSData?" 

CALL:STATus:HSPDschannel[:CELL][:LEVel]?

Function

Queries the current sum of the powers in all of the active HS-PDSCH channels. See Downlink Code Channel Information .

Query

Range: -20.00 to 0 dB, 9.91 E+37

Resolution: 0.01 dB

*RST Setting

9.91 E+37

Requirements

Test Application Revision A.08 and above, with the required feature license

Lab Application Revision: C.03 and above.

Programming Example

 
OUTPUT 714;"CALL:STATus:HSPDschannel?" 

CALL:STATus:HSPDschannel[:CELL]:STATe?

Function

Queries the current state of the HS-PDSCH channels. See Downlink Code Channel Information .

Query

Range:

  • 1 (on) - power is present in one or more HS-PDSCHs
  • 0 (off) - no power is present in any HS-PDSCH

*RST Setting

0 (off)

Requirements

Test Application Revision A.08 and above, with the required feature license

Lab Application Revision: C.03 and above.

Programming Example

 
OUTPUT 714;"CALL:STATus:HSPDschannel:STATe?"

CALL:STATus:HSSCchannel[1][:CELL][:LEVel]?

Function

Queries the current HS-SCCH 1 power level. See Downlink Code Channel Information .

Query

Range: -20.00 to 0 dB, 9.91 E+37

Resolution: 0.01 dB

*RST Setting

9.91 E+37

Requirements

Test Application Revision A.08 and above, with the required feature license

Lab Application Revision: C.03 and above.

Programming Example

 
OUTPUT 714;"CALL:STATus:HSSCchannel?" 

CALL:STATus:HSSCchannel[1][:CELL]:STATe?

Function

Queries the current state of the HS-SCCH 1 channel. See Downlink Code Channel Information .

Query

Range: 1|0

*RST Setting

0 (off)

Requirements

Test Application Revision A.08 and above, with the required feature license

Lab Application Revision: C.03 and above.

Programming Example

 
OUTPUT 714;"CALL:STATus:HSSCchannel:STATe?"

CALL:STATus:HSSCchannel2[:CELL][:LEVel]?

Function

Queries the current HS-SCCH 2 power level. See Downlink Code Channel Information .

Query

Range: -20.00 to 0 dB, 9.91 E+37

Resolution: 0.01 dB

*RST Setting

9.91 E+37

Requirements

Test Application Revision A.08 and above, with the required feature license

Lab Application Revision: C.03 and above.

Programming Example

 
OUTPUT 714;"CALL:STATus:HSSCchannel2?" 

CALL:STATus:HSSCchannel2[:CELL]:STATe?

Function

Queries the current state of the HS-SCCH 2 channel. See Downlink Code Channel Information .

Query

Range: 1|0

*RST Setting

0 (off)

Requirements

Test Application Revision A.08 and above, with the required feature license

Lab Application Revision: C.03 and above.

Programming Example

 
OUTPUT 714;"CALL:STATus:HSSCchannel2:STATe?"

CALL:STATus:HSSCchannel3[:CELL][:LEVel]?

Function

Queries the current HS-SCCH 3 power level. See Downlink Code Channel Information .

Query

Range: -20.00 to 0 dB, 9.91 E+37

Resolution: 0.01 dB

*RST Setting

9.91 E+37

Requirements

Test Application Revision A.08 and above, with the required feature license

Lab Application Revision: C.03 and above.

Programming Example

 
OUTPUT 714;"CALL:STATus:HSSCchannel3?" 

CALL:STATus:HSSCchannel3[:CELL]:STATe?

Function

Queries the current state of the HS-SCCH 3 channel. See Downlink Code Channel Information .

Query

Range: 1|0

*RST Setting

0 (off)

Requirements

Test Application Revision A.08 and above, with the required feature license

Lab Application Revision: C.03 and above.

Programming Example

 
OUTPUT 714;"CALL:STATus:HSSCchannel3:STATe?"

CALL:STATus:HSSCchannel4[:CELL][:LEVel]?

Function

Queries the current HS-SCCH 4 power level. See Downlink Code Channel Information .

Query

Range: -20.00 to 0 dB, 9.91 E+37

Resolution: 0.01 dB

*RST Setting

9.91 E+37

Requirements

Test Application Revision A.08 and above, with the required feature license

Lab Application Revision: C.03 and above.

Programming Example

 
OUTPUT 714;"CALL:STATus:HSSCchannel4?" 

CALL:STATus:HSSCchannel4[:CELL]:STATe?

Function

Queries the current state of the HS-SCCH 4 channel. See Downlink Code Channel Information .

Query

Range: 1|0

*RST Setting

0 (off)

Requirements

Test Application Revision A.08 and above, with the required feature license

Lab Application Revision: C.03 and above.

Programming Example

 
OUTPUT 714;"CALL:STATus:HSSCchannel4:STATe?"

CALL:STATus:MAXimum:ALLowed:CQI:VALue?

Function

Queries the Maximum Allowed CQI Value.

Query

Range: 0 to 30, 9.91 E+37

Resolution: 1

*RST Setting

9.91 E+37

Requirements

Lab Application Revision: F.00 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:MAXimum:ALLowed:CQI:VALue?"

CALL:STATus:MCELl?

Function

Queries Multi-Cell UTRAN Status.

Query

Range: NONE | MAIN | MLOC | MEXT | MSHO | AUX | AACT

*RST Setting

NONE

Requirements

Lab Application Revision: F.01 and above.

Programming Example

 
OUTPUT 714;"CALL:STATus:MCELl?"

CALL:STATus:MM?

Function

Queries MM Status .

Query

Range:

  • MMSTATUS1 (Updated (Normal))
  • MMSTATUS2 (Updated (Periodic))
  • MMSTATUS3 (IMSI Attached)
  • MMSTATUS4 (IMSI Detached)
  • MMSTATUS5 (None)

*RST Setting

MMSTATUS5

Requirements

Test Application Revision: A.05 and above.

Lab Application Revision: B.01 and above.

Programming Example

 
OUTPUT 714;"CALL:STATus:MM?"

CALL:STATus:MPOWer:OFFSet:SIGNaled?

Function

Queries the Last Signaled Measurement Power Offset .

Query

Range: -6.0 to +13.0 9.91E+37

*RST Setting

9.91E+37

Requirements

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:MPOWer:OFFSet:SIGNaled?"

CALL:STATus:MS:HSDSchannel:CATegory?

Function

Queries Current UE HS-DSCH Category .

Query

Range: 1-14, 17, 18, 9.91E+37

*RST Setting

9.91E+37

Requirements

Test Application Revision: A.09 and above, with the required feature license

Lab Application Revision: C.04 and above

Lab Application Revision: D.00 and above

Test Application Revision A.10 and Lab Application Revision D.01 added UE categories 7 and 8

Lab Application Revision F.00.07 expanded range from "1-8, 11, 12" to "1-14, 17, 18"

Programming Example

 
OUTPUT 714;"CALL:STATus:MS:HSDSchannel:CATegory?"

CALL:STATus:OCNSource[:CELL][:LEVel]([:SELected]|:FDD)?

Function

Queries the orthogonal channel noise source (OCNS) level for the selected system type. See Downlink Code Channel Information .

The OCNS level is set using the CALL:OCNSource commands.

The optional [:SELected] keyword in this command specifies that the OCNS channel level being queried applies to the current system type.

Query

Range: 0 to -20 dB, 9.91 E+37

Resolution: 0.01 dB

*RST Setting

9.91 E+37

Requirements

Test or Lab Application Revision: A.01 and above

Test Application Revision A.06 changed *RST Setting to 9.91 E+37.

Lab Application Revision C.01 changed *RST Setting to 9.91 E+37.

Programming Example

 
OUTPUT 714;"CALL:STATus:OCNSource?"

CALL:STATus:OCNSource[:CELL]:STATe([:SELected]|:FDD)?

Function

Queries the current on/off state of the orthogonal channel noise simulator channel (OCNS). See Downlink Code Channel Information .

The OCNS channel on/off state is set using the CALL:OCNSource commands.

The optional [:SELected] keyword in this command specifies that the OCNS channel state being queried applies to the current system type.

Query

Range: 1|0

*RST Setting

1 (on)

Requirements

Test or Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:OCNSource:STATe?"

CALL:STATus:OCNSource:CELL2[:LEVel]([:SELected]|:FDD)?

Function

Queries the cell 2 orthogonal channel noise source (OCNS) level for the selected system type. See Downlink Code Channel Information .

The OCNS level is set using the CALL:CELL2:OCNSource commands.

The optional [:SELected] keyword in this command specifies that the OCNS channel level being queried applies to the current system type.

(See Cell 2 Overview ).

Query

Range: 0 to -20 dB, 9.91 E+37

Resolution: 0.01 dB

*RST Setting

9.91E+37

Requirements

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:OCNSource:CELL2?"

CALL:STATus:OCNSource:CELL2:STATe([:SELected]|:FDD)?

Function

Queries the current cell 2 on/off state of the orthogonal channel noise simulator channel (OCNS). See Downlink Code Channel Information .

The OCNS channel on/off state is set using the CALL:CELL2:OCNSource commands.

The optional [:SELected] keyword in this command specifies that the OCNS channel state being queried applies to the current system type.

(See Cell 2 Overview ).

Query

Range: 1|0

*RST Setting

0 (off)

Requirements

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:OCNSource:CELL2:STATe?"

CALL:STATus:PICHannel[:CELL][:LEVel]?

Function

Queries the current downlink page indicator channel's power. See Downlink Code Channel Information .

Query

Range: -20.00 to 0 dB, 9.91 E+37

Resolution: 0.01 dB

*RST Setting

-8.3 dB

Requirements

Test or Lab Application Revision: A.01 and above

Test Application Revision A.06 changed *RST Setting to -8.3 dB.

Lab Application Revision C.01 changed *RST Setting to -8.3 dB.

Programming Example

 
OUTPUT 714;"CALL:STATus:PICHannel?" 

CALL:STATus:PICHannel[:CELL]:STATe?

Function

Queries the current state of the downlink page indicator channel. See Downlink Code Channel Information .

Query

Range: 1|0

*RST Setting

1 (on)

Requirements

Test or Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:PICHannel:STATe?"

CALL:STATus:PRAChannel[:CELL]:CURCbeta?

Function

Queries the current power gain for the control data of the message portion of the uplink physical random access channel (PRACH) see PRACH Bc/Bd Control .

Query

Range: 2 to 15

Resolution: 1

*RST Setting

15

Requirements

Test Application Revision: A.03 and above

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:PRAChannel:CURCbeta?"

CALL:STATus:PRAChannel[:CELL]:CURDbeta?

Function

Queries the current power gain for the message data of the message portion of the uplink physical random access channel (PRACH) see PRACH Bc/Bd Control .

Query

Range: 0 to 15

Resolution: 1

*RST Setting

15

Requirements

Test Application Revision: A.03 and above

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:PRAChannel:CURDbeta?"

CALL:STATus:REPorted:CQI:LIMitation:COUNt?

Function

Queries the Count of Reported CQI Limitations. This result counts how many times the Maximum Allowed CQI Value is used instead of using reported CQI to avoid code collision.

Query

Range: 0 to 1,500,000, 9.91 E+37

Resolution: 1

*RST Setting

9.91 E+37

Requirements

Lab Application Revision: F.00 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:REPorted:CQI:LIMitation:COUNt?"

CALL:STATus:ROHC:DOWNlink:CID:LARGe?

Function

Queries the Current Downlink ROHC Large CIDs.

This result is inferred from the "Current Downlink ROHC Max CID". If the "Current Downlink ROHC Max CID" is greater than 15, then this result is "True", otherwise this result is "False".

Query

Range: 1|0

*RST Setting

0

Requirements

Lab Application Revision: F.00.19 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:ROHC:DOWNlink:CID:LARGe?"

CALL:STATus:ROHC:DOWNlink:CID:MAXimum?

Function

Queries the Current Downlink ROHC Max CID.

Query

Range: 1 to 16383

Resolution: 1

*RST Setting

15

Requirements

Lab Application Revision: F.00.19 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:ROHC:DOWNlink:CID:MAXimum?"

CALL:STATus:ROHC:DOWNlink:RDDepth?

Function

Queries the Current Downlink Reverse Decompression Depth.

Query

Range: 0 to 65535

Resolution: 1

*RST Setting

0

Requirements

Lab Application Revision: F.00.19 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:ROHC:DOWNlink:RDDepth?"

CALL:STATus:ROHC:UPLink:CID:LARGe?

Function

Queries the Current Uplink ROHC Large CIDs.

This result is inferred from the "Current Uplink ROHC Max CID". If the "Current Uplink ROHC Max CID" is greater than 15, then this result is "True", otherwise this result is "False".

Query

Range: 1|0

*RST Setting

0

Requirements

Lab Application Revision: F.00.19 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:ROHC:UPLink:CID:LARGe?"

CALL:STATus:ROHC:UPLink:CID:MAXimum?

Function

Queries the Current Uplink ROHC Max CID.

Query

Range: 1 to 16383

Resolution: 1

*RST Setting

15

Requirements

Lab Application Revision: F.00.19 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:REPorted:CQI:LIMitation:COUNt?"

CALL:STATus:RRC:STATe?

Function

Queries RRC State .

Query

Range: DCH|FACH|IDLE

*RST Setting

IDLE

Requirements

Lab Application Revision: B.01 and above.

Programming Example

 
OUTPUT 714;"CALL:STATus:RRC:STATe?"

CALL:STATus:SERVice:TYPe?

Function

Queries the Current Service Type .

The current service type will be set to NONE when an event occurs that causes the service to be stopped. These events include:

  • End Call
  • A call processing error that results in a dropped call
  • UE initiated end of service
  • Full or Partial Preset

Query

Range:

  • AMR: AMR Voice
  • AHSP: AMR Voice + PS Data - HSPA (only applicable to the lab application)
  • APSD: AMR +PS Data (only applicable to the lab application)
  • CSDA: CS Data - Async ( only applicable to the lab application )
  • CSDV: CS Data - Video Call ( only applicable to the lab application and to a test application with the required feature license )
  • GPRS: UMTS/GPRS Packet Data ( only applicable to the lab application )
  • PHSP: UMTS/GPRS Packet Data - HSPA ( only applicable to the lab application )
  • PSDH: UMTS/GPRS Packet Data - HSDPA ( only applicable to the lab application )
  • RBT: RB Test Mode
  • RBTH: RB Test Mode - HSDPA ( only applicable to the lab application and to a test application with the required feature license )
  • RHSP: RB Test Mode - HSPA ( only applicable to the test application with the required feature license )
  • MMC: Mobile Management connection ( only applicable to the lab application )
  • NONE

*RST Setting

NONE

Requirements

Test Application Revision: A.01 and above

Test Application Revision A.04 added AMR

Test Application Revision A.06 with the required feature license, added CSDV

Test Application Revision A.08.20 added RBTH

Test Application Revision A.12 with the required feature license and Lab Application Revision E.00.16, added RHSP

Lab Application Revision: A.01 and above

Lab Application Revision A.02 added AMR

Lab Application Revision C.01 added CSDV

Lab Application Revision C.03 added RBTH

Lab Application Revision D.00 added PSDH

Lab Application Revision E.00.16 added APSD

Lab Application Revision U.00.13 added PHSP

Lab Application Revision U.00.31 added AHSP

Lab Application Revision F.00 and above added MMC

Programming Example

 
OUTPUT 714;"CALL:STATus:SERVice:TYPe?"
! Returns the current service type.

CALL:STATus:SETup[:PCReconfig]:CHANnel<[:SELected]|:FDD>UPLink[:CHANnel]?

Function

Queries PCR Info, UL: Channel and Frequency .

Query

Range: see CALL:SETup[:PCReconfig]:CHANnel<[:SELected]|:FDD>:UPLink:CHANnel

*RST Setting

see CALL:SETup[:PCReconfig]:CHANnel<[:SELected]|:FDD>:UPLink:CHANnel

Requirements

Test Application Revision: A.06 and above

Lab Application Revision: C.01 and above

Test Application Revision A.09 and Lab Application Revisions C.04 and D.00, added [:CHANnel]

All other changes match the CALL:SETup[:PCReconfig]:CHANnel<[:SELected]|:FDD>:UPLink:CHANnel command.

Programming Example

 
OUTPUT 714;"CALL:STATus:SETup:CHANnel:UPLink?"

CALL:STATus:SETup[:PCReconfig]:CHANnel<[:SELected]|:FDD>UPLink:SEParation?

Function

Queries the PCR Info, DL/UL Frequency Separation .

Query

Range: MHZ30|MHZ31|MHZ45|MHZ48|MHZ80|MHZ95|MHZ120|MHZ190|MHZ400|NSTD

*RST Setting

MHZ190

Requirements

Test Application Revision: A.09 and above

Test Application Revision A.10.01, added MHZ120

Test Application Revision A.11, added [:PCReconfig]

Lab Application Revision: C.04 and above

Lab Application Revision: D.00 and above

Lab Application Revision D.01.01, added MHZ120

Lab Application Revision D.02, added [:PCReconfig]

Lab Application Revision E.00.34, added MHZ48

Test Application Revision A.14 and Lab Application Revision F.00, added MHZ30 and MHZ31

Programming Example

 
OUTPUT 714;"CALL:STATus:SETup:CHANnel:UPLink:SEParation?"

CALL:STATus:SETup[:PCReconfig]:FBINdicator?

Function

Queries the PCR Info, Frequency Band .

Query

Range: BAND1|BAND2|BAND3|BAND4|BAND5|BAND6|BAND7|BAND8|BAND9|BAND10|
BAND11|BAND12|BAND13|BAND14

*RST Setting

BAND1

Requirements

Test Application Revision: A.09 and above

Lab Application Revisions: C.04 and D.00 and above

Test Application Revision A.10.01 and Lab Application Revision D.01.01, added BAND7

Test Application Revision A.11 and Lab Application Revisions D.02 and E.00, added BAND10

Test Application Revision A.11 and Lab Application Revision D.02, added [:PCReconfig]

Test Application Revision A.13 and Lab Application Revision E.00.34, added BAND11

Test Application Revision A.14 and Lab Application Revision F.00, added BAND12, BAND13, and BAND14

Programming Example

 
OUTPUT 714;"CALL:STATus:SETup:FBINdicator?"

CALL:STATus:SETup:RBReconfig:CHANnel:UPLink[:CHANnel]?

Function

Queries RBR Info, UL: Channel and Frequency .

Query

Range: see CALL:SETup:RBReconfig:CHANnel:UPLink:CHANnel

*RST Setting

see CALL:SETup:RBReconfig:CHANnel:UPLink:CHANnel

Requirements

Test Application Revision A.11 and Lab Application Revision D.02 and above

Lab Application Revision: E.00.34 and above, added 3487 - 3587.

Test Application Revision A.14 and Lab Application Revision F.00 and above, added 3612 - 3678, 3702, 3707, 3732, 3737, 3762, 3767, 3792 - 3818, 3842, 3867, 3892 - 3918, 3942, 3967

Programming Example

 
OUTPUT 714;"CALL:STATus:SETup:RBReconfig:CHANnel:UPLink?"

CALL:STATus:SETup:RBReconfig:CHANnel:UPLink:SEParation?

Function

Queries RBR Info, DL/UL Frequency Separation .

Query

Range: MHZ30|MHZ31|MHZ45|MHZ48|MHZ80|MHZ95|MHZ120|MHZ190|MHZ400|NSTD

*RST Setting

MHZ190

Requirements

Test Application Revision A.11 and Lab Application Revision D.02 and above

Lab Application Revision E.00.34, added MHZ48

Test Application Revision A.14 and Lab Application Revision F.00, added MHZ30 and MHZ31

Programming Example

 
OUTPUT 714;"CALL:STATus:SETup:RBReconfig:CHANnel:UPLink:SEParation?"

CALL:STATus:SETup:RBReconfig:DPCHannel:CBETa?

Function

Queries the beta c value that the test set will signal to the UE during the Radio Bearer Reconfiguration (see RBR Uplink DPCH Bc/Bd Control ).

Query

Range: 1 to 15

Resolution: 1

*RST Setting

8

Requirements

Test Application Revision: A.09 and above

Lab Application Revision: C.04 and above

Lab Application Revision: D.00 and above

Test Application Revision A.11 and Lab Application Revisions D.02 and E.00, range is 1 to 15 (vs. 2 to 15)

Programming Example

 
OUTPUT 714;"CALL:STATus:SETup:RBReconfig:DPCHannel:CBETa?" 

CALL:STATus:SETup:RBReconfig:DPCHannel:DBETa?

Function

Queries the beta d value that the test set will signal to the UE during the Radio Bearer Reconfiguration (see RBR Uplink DPCH Bc/Bd Control ).

Query

Range: 0 to 15

Resolution: 1

*RST Setting

15

Requirements

Test Application Revision: A.09 and above

Lab Application Revision: C.04 and above

Lab Application Revision: D.00 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:SETup:RBReconfig:DPCHannel:DBETa?" 

CALL:STATus:SETup:RBReconfig:FBINdicator?

Function

Queries RBR Info, Frequency Band .

Query

Range: BAND1|BAND2|BAND3|BAND4|BAND5|BAND6|BAND7|BAND8|BAND9|BAND10|
BAND11|BAND12|BAND13|BAND14

*RST Setting

BAND1

Requirements

Test Application Revision A.11 and Lab Application Revision D.02 and above

Lab Application Revision: E.00.34 and above, added BAND11

Test Application Revision A.14 and Lab Application Revision F.00, added BAND12, BAND13, and BAND14

Programming Example

 
OUTPUT 714;"CALL:STATus:SETup:RBReconfig:FBINdicator?"

CALL:STATus:SETup:TCReconfig:CHANnel:UPLink[:CHANnel]?

Function

Queries TCR Info, UL: Channel and Frequency .

Query

Range: see CALL:SETup:TCReconfig:CHANnel:UPLink:CHANnel

*RST Setting

see CALL:SETup:TCReconfig:CHANnel:UPLink:CHANnel

Requirements

Test Application Revision A.11 and Lab Application Revision D.02 and above

Lab Application Revision: E.00.34 and above, added 3487 - 3587.

Test Application Revision A.14 and Lab Application Revision F.00 and above, added 3612 - 3678, 3702, 3707, 3732, 3737, 3762, 3767, 3792 - 3818, 3842, 3867, 3892 - 3918, 3942, 3967

Programming Example

 
OUTPUT 714;"CALL:STATus:SETup:TCReconfig:CHANnel:UPLink?"

CALL:STATus:SETup:TCReconfig:CHANnel:UPLink:SEParation?

Function

Queries TCR Info, DL/UL Frequency Separation .

Query

Range: MHZ30|MHZ31|MHZ45|MHZ48|MHZ80|MHZ95|MHZ120|MHZ190|MHZ400|NSTD

*RST Setting

MHZ190

Requirements

Test Application Revision A.11 and Lab Application Revision D.02 and above

Lab Application Revision E.00.34, added MHZ48

Test Application Revision A.14 and Lab Application Revision F.00, added MHZ30 and MHZ31

Programming Example

 
OUTPUT 714;"CALL:STATus:SETup:TCReconfig:CHANnel:UPLink:SEParation?"

CALL:STATus:SETup:TCReconfig:DPCHannel:CBETa?

Function

Queries the beta c value that the test set will signal to the UE during the Transport Channel Reconfiguration (see TCR DPCH Bc/Bd Control ).

Query

Range: 1 to 15

Resolution: 1

*RST Setting

8

Requirements

Test Application Revision: A.09 and above

Lab Application Revision: C.04 and above

Lab Application Revision: D.00 and above

Test Application Revision A.11 and Lab Application Revisions D.02 and E.00, range is 1 to 15 (vs. 2 to 15)

Programming Example

 
OUTPUT 714;"CALL:STATus:SETup:TCReconfig:DPCHannel:CBETa?" 

CALL:STATus:SETup:TCReconfig:DPCHannel:DBETa?

Function

Queries the beta d value that the test set will signal to the UE during the Transport Channel Reconfiguration (see TCR DPCH Bc/Bd Control ).

Query

Range: 0 to 15

Resolution: 1

*RST Setting

15

Requirements

Test Application Revision: A.09 and above

Lab Application Revision: C.04 and above

Lab Application Revision: D.00 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:SETup:TCReconfig:DPCHannel:DBETa?" 

CALL:STATus:SETup:TCReconfig:FBINdicator?

Function

Queries TCR Info, Frequency Band .

Query

Range: BAND1|BAND2|BAND3|BAND4|BAND5|BAND6|BAND7|BAND8|BAND9|BAND10|
BAND11|BAND12|BAND13|BAND14

*RST Setting

BAND1

Requirements

Test Application Revision A.11 and Lab Application Revision D.02 and above

Test Application Revision A.13 and Lab Application Revision E.00.34 and above, added BAND11

Test Application Revision A.14 and Lab Application Revision F.00, added BAND12, BAND13, and BAND14

Programming Example

 
OUTPUT 714;"CALL:STATus:SETup:TCReconfig:FBINdicator?"

CALL:STATus:SGRant:RELative:QUEued:COUNt?

Function

Queries Queued Relative Grants .

Query

Range: 0 to 1000

*RST Setting

0

Requirements

Test Application Revision A.12 and above, with the required feature license

Lab Application Revision E.00.16 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:SGRant:RELative:QUEued:COUNt?"

CALL:STATus:SHANdoff:EVENt?

Function

Queries the most recent Intra Frequency Event identifier. Events can be:

(See Event Reporting ).

Query

Range: 1A|1B|1C|1D|1E|1F|NONE

*RST Setting

NONE

Requirements

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:SHANdoff:EVENt?" !Returns the most recent event.

CALL:STATus:SHANdoff:EVENt:CELLid?

Function

Queries the cell that triggered the most recent event. (See Event Reporting ).

Query

Range: CELL1|CELL2|NONE

*RST Setting

NONE

Requirements

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:SHANdoff:EVENt:CELLid?" 

CALL:STATus:SHANdoff:STATe?

Function

Queries Soft Handover State .

Query

Range: 1|0

*RST Setting

0

Requirements

Lab Application Revision: B.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:SHANdoff:STATe?" 

CALL:STATus:TOTal:POWer[:AMPLitude]?

Function

Queries the current total RF power for the specified system type. The total RF power is equal to the sum of the cell power setting (see CALL:POWer ) and the AWGN setting (see CALL:AWGNoise ).

See Cell Power and AWGN Power for more information about desired versus current power levels.

Query

Range:

Resolution: 0.01 dB

*RST Setting

-75.00 dBm

Requirements

Test or Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:TOTal:POWer?"

CALL:STATus:TOTal:POWer:STATe?

Function

Queries the current total RF power measurement's state for the currently selected system type.

This query will return a 1 (on) if the current cell power ( CALL:POWer ) power state is on.

Query

Range: 1|0

*RST Setting

1 (on)

Requirements

Test or Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:STATus:TOTal:POWer:STATe?"

CALL:STATus:UPLink:CHANnel?

Function

Queries the Current Info, UL: Channel and Frequency .

Query

Range: see CALL:UPLink:CHANnel:CHANnel

*RST Setting

9750

Requirements

Test Application Revision: A.06 and above

Lab Application Revision: C.01 and above

All other changes match the CALL:UPLink:CHANnel:CHANnel command.

Programming Example

 
OUTPUT 714;"CALL:STATus:UPLink:CHANnel?"

CALL:STATus:UPLink:SEParation?

Function

Queries the Current Info, DL/UL Frequency Separation .

Query

Range: MHZ30|MHZ31|MHZ45|MHZ48|MHZ80|MHZ95|MHZ120|MHZ190|MHZ400|NSTD

*RST Setting

MHZ190

Requirements

Test Application Revision: A.08 and above

Lab Application Revision: C.03 and above

Test Application Revision A.10.01 and Lab Application Revision D.01.01 added MHZ120

Lab Application Revision E.00.34, added MHZ48

Test Application Revision A.14 and Lab Application Revision F.00, added MHZ30 and MHZ31

Programming Example

 
OUTPUT 714;"CALL:STATus:UPLink:SEParation?"


Top of pagetop of page     

+ +