CALL:STATus
Last updated: September 2, 2009
The CALL:STATus commands are query only. They return values that indicate the test set's actual hardware settings. Actual hardware settings can differ from settings the user has entered, most frequently due to an error condition. When no error conditions exist, the commands used to enter values return the same results as the commands used to query actual hardware settings. For example, "CALL:AWGNoise:POWer?" returns the same value as "CALL:STATus:AWGNoise:POWer?" when no error conditions exist.
GPIB Command Conventions
CALL:STATus[:STATe][:VOICe]?
|
Function
|
Queries the status of the call. See
Call Connection State
.
|
|
Query
|
Range: CALL|CONN|HAND|IDLE|PAG|REG|REL|SREQ
Only IDLE is returned in FDD Test operating mode.
|
|
*RST Setting
|
IDLE |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
Test Application Revision: A.05 and above added CALL
Lab Application Revision: B.01 and above added CALL
|
|
Programming Example
OUTPUT 714;"CALL:STATus?"
! Returns the current call processing state.
|
CALL:STATus:AICHannel[:CELL][:LEVel]?
|
Function
|
Queries the current level of the acquisition indicator channel. This query is not applicable to FDD Test operating mode. See
Downlink Code Channel Information
.
|
|
Query
|
Range: -20.00 to 0 dB, 9.91 E+37
Resolution: 0.01 dB
|
|
*RST Setting
|
-9.9 dB |
|
Requirements
|
Test Application Revision: A.02 and above
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:AICHannel?"
|
CALL:STATus:AICHannel[:CELL]:STATe?
|
Function
|
Queries the current state of the acquisition indicator channel. This query is not applicable to FDD Test operating mode. See
Downlink Code Channel Information
.
|
|
Query
|
Range: 0|1
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test Application Revision: A.02 and above
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:AICHannel:STATe?"
|
CALL:STATus[:GMM]:ATTached:STATe?
|
Function
|
Queries the attached state of the UE. See
GMM State
.
|
|
Query
|
Range:
-
ATT - attached
-
ATTINC - attach incomplete
-
DET - detached
-
NONE
|
|
*RST Setting
|
NONE |
|
Requirements
|
Test Application Revision: A.08.20 and above
Lab Application Revision: A.02 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:ATTached:STATe?"
|
CALL:STATus:AWGNoise[:INTernal]:POWer[:AMPLitude]([:SELected]|:FDD)?
|
Function
|
Queries the current power level of the additive white Gaussian noise (AWGN) source. AWGN power level is set using the
CALL:AWGNoise
commands.
The optional [:SELected] mnemonic in this command specifies that the AWGN power level being queried applies to the current system type (FDD is currently the only system type available).
See
Cell Power and AWGN Power
for more information about desired versus current power levels.
|
|
Query
|
Range:
Resolution: 0.01 dB
|
|
*RST Setting
|
9.91 E+37 (NAN) |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:AWGNoise:POWer?"
!Queries the current AWGN power.
|
CALL:STATus:AWGNoise[:INTernal]:POWer:STATe?
|
Function
|
Queries the current on/off state of the additive white Gaussian noise (AWGN) source. AWGN power level on/off state is set using the
CALL:AWGNoise
commands.
See
Cell Power and AWGN Power
for more information about desired versus current power levels.
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:AWGNoise:POWer:STATe?"
|
CALL:STATus:CCPChannel:PRIMary[:CELL[1]][:LEVel]?
|
Function
|
Queries the current level of the primary common control physical channel. See
Downlink Code Channel Information
.
|
|
Query
|
Range: -20.00 to 0 dB, 9.91 E+37
Resolution: 0.01 dB
|
|
*RST Setting
|
-5.3 dB |
|
Requirements
|
Test or Lab Application Revision: A.01 and above.
Test Application Revision A.06 changed *RST Setting to -5.3 dB.
Lab Application Revision C.01 changed *RST Setting to -5.3 dB.
|
|
Programming Example
OUTPUT 714;"CALL:STATus:CCPChannel:PRIMary?"
|
CALL:STATus:CCPChannel:PRIMary[:CELL[1]]:STATe?
|
Function
|
Queries the current state of the primary common control physical channel. See
Downlink Code Channel Information
.
|
|
Query
|
Range: 0|1
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:CCPChannel:PRIMary:STATe?"
|
CALL:STATus:CCPChannel:PRIMary:CELL2[:LEVel]?
|
Function
|
Queries the current level of the cell 2 primary common control physical channel. See
Cell 2 Overview
and
Downlink Code Channel Information
.
|
|
Query
|
Range: -20.00 to 0 dB, 9.91 E+37
Resolution: 0.01 dB
|
|
*RST Setting
|
9.91E+37 |
|
Requirements
|
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:CCPChannel:PRIMary:CELL2?"
|
CALL:STATus:CCPChannel:PRIMary:CELL2:STATe?
|
Function
|
Queries the current state of the cell 2 primary common control physical channel. See
Cell 2 Overview
and
Downlink Code Channel Information
.
|
|
Query
|
Range: 0|1
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:CCPChannel:PRIMary:CELL2:STATe?"
|
CALL:STATus:CCPChannel:SECondary[:CELL][:LEVel]?
|
Function
|
Queries the current level of the secondary common control physical channel. See
Downlink Code Channel Information
.
|
|
Query
|
Range: -20.00 to 0 dB, 9.91 E+37
Resolution: 0.01 dB
|
|
*RST Setting
|
-10.3 dB |
|
Requirements
|
Test Application Revision: A.02 and above
Lab Application Revision: A.01 and above
Test Application Revision A.06 changed *RST Setting to -10.3 dB.
Lab Application Revision C.01 changed *RST Setting to -10.3 dB.
|
|
Programming Example
OUTPUT 714;"CALL:STATus:CCPChannel:SECondary?"
|
CALL:STATus:CCPChannel:SECondary[:CELL]:STATe?
|
Function
|
Queries the current state of the secondary common control physical channel. See
Downlink Code Channel Information
.
|
|
Query
|
Range: 0|1
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test Application Revision: A.02 and above
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:CCPChannel:SECondary:STATe?"
|
CALL:STATus:CELL[1]:POWer[:AMPLitude]?
|
Function
|
Queries the current cell power level. Cell power is set using the
CALL:POWer
commands.
See
Cell Power and AWGN Power
for more information about desired versus current power levels.
|
|
Query
|
Range:
Resolution: 0.01 dB
|
|
*RST Setting
|
-75.00 dBm |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:CELL:POWer:AMPLitude?"
|
CALL:STATus:CELL[1]:POWer:STATe?
|
Function
|
Queries the current state of the cell power setting. Cell power state is set using the
CALL:POWer
commands.
See
Cell Power and AWGN Power
for more information about desired versus current power levels.
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:CELL:POWer:STATe?"
|
CALL:STATus:CELL:SYSTem[:TYPE]?
|
Function
|
Queries the current system type that the test set is currently emulating.
When the test set is in active cell operating mode (see
CALL:OPERating
) the current system type is selected by the
CALL:SYSTem
command. (Active cell operating mode is not available in the initial W-CDMA test application release.)
When the test set is in any test mode operating mode (see
CALL:OPERating
) or CW operating mode, this command will return the corresponding system type.
|
|
Query
|
Range: FDD|CW
|
|
*RST Setting
|
FDD |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:CELL:SYSTem?"
|
CALL:STATus:CELL2:POWer[:AMPLitude]?
|
Function
|
Queries the current cell 2 power level. (See
Cell 2 Overview
).
|
|
Query
|
Range:
-
-165 dBm/3.84 MHz to +37dBm/3.84 MHz, 9.91 E+37
(-115 dBm/3.84 MHz to -13 dBm/3.84 MHz actual hardware range with amplitude offset = 0)
The actual power range is defined by adding the value of the associated amplitude offset to the range above. For example, if amplitude offset is -3.5 dB, then the power range will be -118.5 dBm/3.84 MHz to -16.5 dBm/3.84 MHz.
Resolution: 0.01 dBm/3.84 MHz
|
|
*RST Setting
|
9.91E+37 |
|
Requirements
|
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:CELL2:POWer?"
|
CALL:STATus:CELL2:POWer:STATe?
|
Function
|
Queries the current state of the cell 2 power setting. (See
Cell 2 Overview
).
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:CELL2:POWer:STATe?"
|
CALL:STATus:COMPressed:STATe?
|
Function
|
Queries
Compressed Mode State/Overall CM
(see
Enabling/Disabling Compressed Mode
).
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Lab Application Revision: B.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:COMPressed:STATe?"
|
CALL:STATus:COMPressed:TGPSequence:ALL:STATe?
|
Function
|
Queries which TGPSs are currently active. The first num value corresponds to the
First TGPS
, the second num value corresponds to the
Second TGPS
, etc. See
Enabling/Disabling Compressed Mode
.
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0, 0, 0, 0 |
|
Requirements
|
Lab Application Revision: D.00.04 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:COMPressed:TGPSequence:ALL:STATe?"
|
CALL:STATus:CPC:DRX:ACTivated?
|
Function
|
Queries the Current DRX Activated State.
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:STATus:CPC:DRX:ACTivated?"
|
CALL:STATus:CPC:DTX:ACTivated?
|
Function
|
Queries the current DTX Activated State.
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:STATus:CPC:DTX:ACTivated?"
|
CALL:STATus:CPC:DTX:TRANsition:C1Cycle2:COUNt?
|
Function
|
Queries the number of DTX Cycle 1 to Cycle 2 transitions.
|
|
Query
|
Range: 0 to 150,000, 9.91 E+37
Resolution: 0.01
|
|
*RST Setting
|
9.91 E+37 |
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:STATus:CPC:DTX:TRANsition:C1Cycle2:COUNt?"
|
CALL:STATus:CPC:HLESs:ACTivated?
|
Function
|
Queries the Current HS-SCCH-less Activated State.
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Lab Application Revision: F.01 and above |
|
Programming Example
OUTPUT 714;"CALL:STATus:CPC:HLESs:ACTivated?"
|
CALL:STATus:CPC:HLESs:TBSize?
|
Function
|
Queries the TB size that is being used for HS-SCCH-less operation.
|
|
Query
|
Range: 137 to 1483 bits, 9.91 E+37
Resolution: 0.01
|
|
*RST Setting
|
9.91 E+37 |
|
Requirements
|
Lab Application Revision: F.01 and above |
|
Programming Example
OUTPUT 714;"CALL:STATus:CPC:HLESs:TBSize?"
|
CALL:STATus:CPC:MS:DPCChannel:BURSt[1]:COUNt?
|
Function
|
Queries the Number of DPCCH Burst 1 Transmissions.
|
|
Query
|
Range: 0 to 150,000, 9.91 E+37
Resolution: 0.01
|
|
*RST Setting
|
9.91 E+37 |
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:STATus:CPC:MS:DPCChannel:BURSt:COUNt?"
|
CALL:STATus:CPC:MS:DPCChannel:BURSt2:COUNt?
|
Function
|
Queries the Number of DPCCH Burst 2 Transmissions.
|
|
Query
|
Range: 0 to 150,000, 9.91 E+37
Resolution: 0.01
|
|
*RST Setting
|
9.91 E+37 |
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:STATus:CPC:MS:DPCChannel:BURSt2:COUNt?"
|
CALL:STATus:CPC:MS:DRX:CONFigured?
|
Function
|
Queries whether the DL DRX configuration has been successfully configured in the UE.
This result is only available in Active Cell mode.
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (false) |
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:STATus:CPC:MS:DRX:CONFigured?"
|
CALL:STATus:CPC:MS:DTX:CONFigured?
|
Function
|
Queries whether UL DTX configuration has been successfully configured in the UE.
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (false) |
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:STATus:CPC:MS:DTX:CONFigured?"
|
CALL:STATus:CPC:MS:HLESs:CONFigured?
|
Function
|
Queries whether HS-SCCH-less configuration has been successfully configured in the UE..
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (false) |
|
Requirements
|
Lab Application Revision: F.01 and above |
|
Programming Example
OUTPUT 714;"CALL:STATus:CPC:MS:HLESs:CONFigured?"
|
CALL:STATus:CPIChannel[:CELL[1]][:LEVel]?
|
Function
|
Queries the current common pilot channel's power. See
Downlink Code Channel Information
.
|
|
Query
|
Range: -20.00 to 0 dB, 9.91 E+37
Resolution: 0.01 dB
|
|
*RST Setting
|
-3.3 dB |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
Test Application Revision A.06 changed *RST Setting to -3.3 dB.
Lab Application Revision C.01 changed *RST Setting to -3.3 dB.
|
|
Programming Example
OUTPUT 714;"CALL:STATus:CPIChannel?"
|
CALL:STATus:CPIChannel[:CELL[1]]:POWer[:AMPLitude]?
|
Function
|
Queries the current cell1 CPICH power level in dBm (current Cell Power + current CPICH level). See
Downlink Code Channel Information
.
|
|
Query
|
Range: -165.00 dBm to +37.00 dBm, 9.91 E+37
Resolution: 0.01 dB
|
|
*RST Setting
|
-78.3 dBm |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:CPIChannel:POWer?"
|
CALL:STATus:CPIChannel[:CELL[1]]:STATe?
|
Function
|
Queries the current state of the common pilot channel. See
Downlink Code Channel Information
.
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:CPIChannel:STATe?"
|
CALL:STATus:CPIChannel:CELL2[:LEVel]?
|
Function
|
Queries the current cell 2 common pilot channel's power. See
Cell 2 Overview
and
Downlink Code Channel Information
.
|
|
Query
|
Range: -20.00 to 0 dB, 9.91 E+37
Resolution: 0.01 dB
|
|
*RST Setting
|
9.91E+37 |
|
Requirements
|
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:CPIChannel:CELL2?"
|
CALL:STATus:CPIChannel:CELL2:POWer[:AMPLitude]?
|
Function
|
Queries the current cell2 CPICH power level in dBm (current Cell 2 Power + current Cell 2 CPICH level). See
Cell 2 Overview
and
Downlink Code Channel Information
.
|
|
Query
|
Range: -165.00 dBm to +37.00 dBm, 9.91 E+37
Resolution: 0.01 dB
|
|
*RST Setting
|
9.91 E+37 |
|
Requirements
|
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:CPIChannel:CELL2:POWer?"
|
CALL:STATus:CPIChannel:CELL2:STATe?
|
Function
|
Queries the current state of the cell 2 common pilot channel. See
Cell 2 Overview
and
Downlink Code Channel Information
.
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:CPIChannel:CELL2:STATe?"
|
CALL:STATus[:STATe]:DATA?
|
Function
|
Queries the status of the data connection. See
Data Connection State
.
|
|
Query
|
Range: ATTG|DET|IDLE|OFF|PDPAG|PDP|PDPD
|
|
*RST Setting
|
OFF |
|
Requirements
|
Test Application Revision: A.03 and above
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:DATA?"
! Returns the current data connection state.
|
CALL:STATus:DPCHannel[:LEVel]?
|
Function
|
Queries the current dedicated physical channel's power. See
Downlink Code Channel Information
.
|
|
Query
|
Range: -20.00 to 0 dB, 9.91 E+37
Resolution: 0.01 dB
|
|
*RST Setting
|
9.91 E+37 |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:DPCHannel?"
|
CALL:STATus:DPCHannel:STATe?
|
Function
|
Queries the current state of the dedicated physical channel. See
Downlink Code Channel Information
.
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:DPCHannel:STATe?"
|
CALL:STATus:DPCHannel:CELL2[:LEVel]?
|
Function
|
Queries the current cell 2 dedicated physical channel's power. See
Cell 2 Overview
and
Downlink Code Channel Information
.
|
|
Query
|
Range: -20.00 to 0 dB, 9.91 E+37
Resolution: 0.01 dB
|
|
*RST Setting
|
9.91 E+37 |
|
Requirements
|
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:DPCHannel:CELL2?"
|
CALL:STATus:DPCHannel:CELL2:STATe?
|
Function
|
Queries the current state of the cell 2 dedicated physical channel. See
Cell 2 Overview
and
Downlink Code Channel Information
.
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:DPCHannel:CELL2:STATe?"
|
CALL:STATus:DPCHannel[:CELL]:CURCbeta?
|
Function
|
Queries the current power gain of the dedicated physical control channel (DPCCH) see
Uplink DPCH Bc/Bd Control
.
|
|
Query
|
Range: 1 to 15
Resolution: 1
|
|
*RST Setting
|
8 |
|
Requirements
|
Test Application Revision: A.03 and above
Lab Application Revision: A.01 and above
Test Application Revision A.11 and Lab Application Revisions D.02 and E.00, range is 1 to 15 (vs. 2 to 15)
|
|
Programming Example
OUTPUT 714;"CALL:STATus:DPCHannel:CURCbeta?"
|
CALL:STATus:DPCHannel[:CELL]:CURDbeta?
|
Function
|
Queries the current power gain of the dedicated physical data channel (DPDCH) see
Uplink DPCH Bc/Bd Control
.
|
|
Query
|
Range: 0 to 15
Resolution: 1
|
|
*RST Setting
|
15 |
|
Requirements
|
Test Application Revision: A.03 and above
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:DPCHannel:CURDbeta?"
|
CALL:STATus:DPCHannel:OFFSet?
|
Function
|
Queries the
Current DPCH Offset
. |
|
Query
|
Range: 0 to 2560
Resolution: 256
|
|
*RST Setting
|
0 chips |
|
Requirements
|
Test Application Revision: A.09 and above
Lab Application Revision: C.04 and above
Lab Application Revision: D.00 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:DPCHannel:OFFSet?"
|
CALL:STATus:EAGChannel[:CELL][:LEVel]?
|
Function
|
Queries the current level of the E-AGCH. See
Downlink Code Channel Information
. |
|
Query
|
Range: -20.00 dB to 0.00 dB, 9.91E+37
Resolution: 0.01 dB
|
|
*RST Setting
|
9.91E+37 |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:EAGChannel?"
|
CALL:STATus:EAGChannel[:CELL]:STATe?
|
Function
|
Queries the current state of the E-AGCH. See
Downlink Code Channel Information
. |
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:EAGChannel:STATe?"
|
CALL:STATus:EDCHannel[:CELL]:BLOCk:SIZE[:LAST]?
|
Function
|
Queries the
Last Block Size
. |
|
Query
|
Range: 0 to 20000 bits, 9.91E+37
Resolution: 1 bit
|
|
*RST Setting
|
9.91E+37 |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:EDCHannel:BLOCk:SIZE?"
|
CALL:STATus:EDCHannel[:CELL]:BLOCk:SIZE:AVERage?
|
Function
|
Queries the
Avg Block Size
. |
|
Query
|
Range: 0 to 20000 bits, 9.91E+37
Resolution: 1 bit
|
|
*RST Setting
|
9.91E+37 |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:EDCHannel:BLOCk:SIZE:AVERage?"
|
CALL:STATus:EDCHannel[:CELL]:BLOCk:SIZE:MAXimum?
|
Function
|
Queries the
Max Block Size
. |
|
Query
|
Range: 0 to 20000 bits, 9.91E+37
Resolution: 1 bit
|
|
*RST Setting
|
9.91E+37 |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:EDCHannel:BLOCk:SIZE:MAXimum?"
|
CALL:STATus:EDCHannel[:CELL]:BLOCk:SIZE:MINimum?
|
Function
|
Queries the
Min Block Size
. |
|
Query
|
Range: 0 to 20000 bits, 9.91E+37
Resolution: 1 bit
|
|
*RST Setting
|
9.91E+37 |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:EDCHannel:BLOCk:SIZE:MINimum?"
|
CALL:STATus:EDCHannel[:CELL]:IBTHroughput?
|
Function
|
Queries the
Throughput
. |
|
Query
|
Range: 0 to 5760 kbps, 9.91E+37
Resolution: 1 kbps
|
|
*RST Setting
|
9.91E+37 |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:EDCHannel:IBTHroughput?"
|
CALL:STATus:EHIChannel[:CELL][:LEVel]?
|
Function
|
Queries the current level of the E-HICH. See
Downlink Code Channel Information
. |
|
Query
|
Range: -20.00 dB to 0.00 dB, 9.91E+37
Resolution: 0.01 dB
|
|
*RST Setting
|
9.91E+37 |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:EHIChannel?"
|
CALL:STATus:EHIChannel[:CELL]:STATe?
|
Function
|
Queries the current state of the E-HICH. See
Downlink Code Channel Information
. |
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:EHIChannel:STATe?"
|
CALL:STATus:EHIChannel[:CELL]:ACK[:COUNt]?
|
Function
|
Queries the
ACKs Transmitted
. |
|
Query
|
Range: 0 to 150000, 9.91E+37
Resolution: 1
|
|
*RST Setting
|
9.91E+37 |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:EHIChannel:ACK?"
|
CALL:STATus:EHIChannel[:CELL]:NACK[:COUNt]?
|
Function
|
Queries the
ACKs Transmitted
. |
|
Query
|
Range: 0 to 150000, 9.91E+37
Resolution: 1
|
|
*RST Setting
|
9.91E+37 |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:EHIChannel:NACK?"
|
CALL:STATus:ERGChannel[:CELL][:LEVel]?
|
Function
|
Queries the current level of the E-RGCH. See
Downlink Code Channel Information
. |
|
Query
|
Range: -20.00 dB to 0.00 dB, 9.91E+37
Resolution: 0.01 dB
|
|
*RST Setting
|
9.91E+37 |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:ERGChannel?"
|
CALL:STATus:ERGChannel[:CELL]:STATe?
|
Function
|
Queries the current state of the E-RGCH. See
Downlink Code Channel Information
. |
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:ERGChannel:STATe?"
|
CALL:STATus:ETFCi[:LAST]?
|
Function
|
Queries the
Last Received E-TFCI
. |
|
Query
|
Range: 0 to 127, 9.91E+37
Resolution: 1
|
|
*RST Setting
|
9.91E+37 |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:ETFCi?"
|
CALL:STATus:ETFCi:RECord[:STATe]?
|
Function
|
Queries the
E-TFCI Recording State
. |
|
Query
|
Range: REC(recording)|IDLE
|
|
*RST Setting
|
IDLE |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:ETFCi:RECord?"
|
CALL:STATus:ETFCi:RECord:ALL?
|
Function
|
Queries the
Recorded E-TFCI Values
. This result always returns 50 comma-separated numbers;
Number of E-TFCI Results Recorded
E-TFCI values, followed by NANs (9.91E+37).
|
|
Query
|
Range: 0 to 127, 9.91E+37
Resolution: 1
|
|
*RST Setting
|
9.91E+37 |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:ETFCi:RECord:ALL?"
|
CALL:STATus:ETFCi:RECord:COUNt?
|
Function
|
Queries the
Number of E-TFCI Results Recorded
. |
|
Query
|
Range: 0 to 50
Resolution: 1
|
|
*RST Setting
|
0 |
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:ETFCi:RECord:COUNt?"
|
CALL:STATus:ETFCi:RECord:FRAMe:INDicator?
|
Function
|
Queries the Recorded E-TFCI Integrity Indicators. |
|
Query
|
Range: An array of 50 values, each element of the array has the following range:
- NONE (No value recorded)
- GCRC (Good CRC)
- BCRC (Bad CRC)
- DTX (EDPDCH subframe is DTX'd for an E-DCH TTI transmission)
|
|
*RST Setting
|
NONE (No value recorded) |
|
Requirements
|
Lab Application Revision: E.00.34 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:ETFCi:RECord:FRAMe:INDicator?"
|
CALL:STATus:FBINdicator?
|
Function
|
Queries the
Current Info, Frequency Band
.
|
|
Query
|
Range: BAND1|BAND2|BAND3|BAND4|BAND5|BAND6|BAND7|BAND8|BAND9|BAND10|
BAND11|BAND12|BAND13|BAND14
|
|
*RST Setting
|
BAND1 |
|
Requirements
|
Test Application Revision: A.08 and above.
Test Application Revision A.09, added BAND8 and BAND9.
Lab Application Revision: C.03 and above.
Lab Application Revision C.04 and D.00, added BAND8 and BAND9.
Test Application Revision A.10.01 and Lab Application Revision D.01.01 added BAND7
Test Application Revision A.11 and Lab Application Revisions D.02 and E.00, added BAND10
Test Application Revision A.13 and Lab Application Revision E.00.34, added BAND11
Test Application Revision A.14 and Lab Application Revision F.00, added BAND12, BAND13, BAND14
|
|
Programming Example
OUTPUT 714;"CALL:STATus:FBINdicator?"
|
CALL:STATus:HSDSchannel:TBSize?
|
Function
|
Queries the
Current Test Mode Transport Block Size
. |
|
Query
|
Range: 120 to 42192
Resolution: 1
|
|
Requirements
|
Test Application Revision: A.09 and above, with the required feature license
Lab Application Revision: C.04 and above
Lab Application Revision: D.00 and above
Test Application Revision A.14 and Lab Application Revision F.00 and above, range extended.
|
|
Programming Example
OUTPUT 714;"CALL:STATus:HSDSchannel:TBSize?"
|
CALL:STATus:HSDSchannel:TBSize:PSData?
|
Function
|
Queries the
Current Test Mode Transport Block Size
. |
|
Query
|
Range: 137 to 27952
Resolution: 1
|
|
*RST Setting
|
4664 |
|
Requirements
|
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:HSDSchannel:TBSize:PSData?"
|
CALL:STATus:HSPDschannel[:CELL][:LEVel]?
|
Function
|
Queries the current sum of the powers in all of the active HS-PDSCH channels. See
Downlink Code Channel Information
.
|
|
Query
|
Range: -20.00 to 0 dB, 9.91 E+37
Resolution: 0.01 dB
|
|
*RST Setting
|
9.91 E+37 |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:STATus:HSPDschannel?"
|
CALL:STATus:HSPDschannel[:CELL]:STATe?
|
Function
|
Queries the current state of the HS-PDSCH channels. See
Downlink Code Channel Information
.
|
|
Query
|
Range:
-
1 (on) - power is present in one or more HS-PDSCHs
-
0 (off) - no power is present in any HS-PDSCH
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:STATus:HSPDschannel:STATe?"
|
CALL:STATus:HSSCchannel[1][:CELL][:LEVel]?
|
Function
|
Queries the current HS-SCCH 1 power level. See
Downlink Code Channel Information
.
|
|
Query
|
Range: -20.00 to 0 dB, 9.91 E+37
Resolution: 0.01 dB
|
|
*RST Setting
|
9.91 E+37 |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:STATus:HSSCchannel?"
|
CALL:STATus:HSSCchannel[1][:CELL]:STATe?
|
Function
|
Queries the current state of the HS-SCCH 1 channel. See
Downlink Code Channel Information
.
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:STATus:HSSCchannel:STATe?"
|
CALL:STATus:HSSCchannel2[:CELL][:LEVel]?
|
Function
|
Queries the current HS-SCCH 2 power level. See
Downlink Code Channel Information
.
|
|
Query
|
Range: -20.00 to 0 dB, 9.91 E+37
Resolution: 0.01 dB
|
|
*RST Setting
|
9.91 E+37 |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:STATus:HSSCchannel2?"
|
CALL:STATus:HSSCchannel2[:CELL]:STATe?
|
Function
|
Queries the current state of the HS-SCCH 2 channel. See
Downlink Code Channel Information
.
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:STATus:HSSCchannel2:STATe?"
|
CALL:STATus:HSSCchannel3[:CELL][:LEVel]?
|
Function
|
Queries the current HS-SCCH 3 power level. See
Downlink Code Channel Information
.
|
|
Query
|
Range: -20.00 to 0 dB, 9.91 E+37
Resolution: 0.01 dB
|
|
*RST Setting
|
9.91 E+37 |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:STATus:HSSCchannel3?"
|
CALL:STATus:HSSCchannel3[:CELL]:STATe?
|
Function
|
Queries the current state of the HS-SCCH 3 channel. See
Downlink Code Channel Information
.
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:STATus:HSSCchannel3:STATe?"
|
CALL:STATus:HSSCchannel4[:CELL][:LEVel]?
|
Function
|
Queries the current HS-SCCH 4 power level. See
Downlink Code Channel Information
.
|
|
Query
|
Range: -20.00 to 0 dB, 9.91 E+37
Resolution: 0.01 dB
|
|
*RST Setting
|
9.91 E+37 |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:STATus:HSSCchannel4?"
|
CALL:STATus:HSSCchannel4[:CELL]:STATe?
|
Function
|
Queries the current state of the HS-SCCH 4 channel. See
Downlink Code Channel Information
.
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Test Application Revision A.08 and above, with the required feature license
Lab Application Revision: C.03 and above.
|
|
Programming Example
OUTPUT 714;"CALL:STATus:HSSCchannel4:STATe?"
|
CALL:STATus:MAXimum:ALLowed:CQI:VALue?
|
Function
|
Queries the Maximum Allowed CQI Value.
|
|
Query
|
Range: 0 to 30, 9.91 E+37
Resolution: 1
|
|
*RST Setting
|
9.91 E+37 |
|
Requirements
|
Lab Application Revision: F.00 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:MAXimum:ALLowed:CQI:VALue?"
|
CALL:STATus:MCELl?
|
Function
|
Queries Multi-Cell UTRAN Status.
|
|
Query
|
Range: NONE | MAIN | MLOC | MEXT | MSHO | AUX | AACT
|
|
*RST Setting
|
NONE |
|
Requirements
|
Lab Application Revision: F.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:STATus:MCELl?"
|
CALL:STATus:MM?
|
Function
|
Queries
MM Status
.
|
|
Query
|
Range:
-
MMSTATUS1 (Updated (Normal))
-
MMSTATUS2 (Updated (Periodic))
-
MMSTATUS3 (IMSI Attached)
-
MMSTATUS4 (IMSI Detached)
-
MMSTATUS5 (None)
|
|
*RST Setting
|
MMSTATUS5 |
|
Requirements
|
Test Application Revision: A.05 and above.
Lab Application Revision: B.01 and above.
|
|
Programming Example
OUTPUT 714;"CALL:STATus:MM?"
|
CALL:STATus:MPOWer:OFFSet:SIGNaled?
|
Function
|
Queries the
Last Signaled Measurement Power Offset
.
|
|
Query
|
Range: -6.0 to +13.0 9.91E+37
|
|
*RST Setting
|
9.91E+37 |
|
Requirements
|
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:MPOWer:OFFSet:SIGNaled?"
|
CALL:STATus:MS:HSDSchannel:CATegory?
|
Function
|
Queries
Current UE HS-DSCH Category
.
|
|
Query
|
Range: 1-14, 17, 18, 9.91E+37
|
|
*RST Setting
|
9.91E+37 |
|
Requirements
|
Test Application Revision: A.09 and above, with the required feature license
Lab Application Revision: C.04 and above
Lab Application Revision: D.00 and above
Test Application Revision A.10 and Lab Application Revision D.01 added UE categories 7 and 8
Lab Application Revision F.00.07 expanded range from "1-8, 11, 12" to "1-14, 17, 18"
|
|
Programming Example
OUTPUT 714;"CALL:STATus:MS:HSDSchannel:CATegory?"
|
CALL:STATus:OCNSource[:CELL][:LEVel]([:SELected]|:FDD)?
|
Function
|
Queries the orthogonal channel noise source (OCNS) level for the selected system type. See
Downlink Code Channel Information
.
The OCNS level is set using the
CALL:OCNSource
commands.
The optional [:SELected] keyword in this command specifies that the OCNS channel level being queried applies to the current system type.
|
|
Query
|
Range: 0 to -20 dB, 9.91 E+37
Resolution: 0.01 dB
|
|
*RST Setting
|
9.91 E+37 |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
Test Application Revision A.06 changed *RST Setting to 9.91 E+37.
Lab Application Revision C.01 changed *RST Setting to 9.91 E+37.
|
|
Programming Example
OUTPUT 714;"CALL:STATus:OCNSource?"
|
CALL:STATus:OCNSource[:CELL]:STATe([:SELected]|:FDD)?
|
Function
|
Queries the current on/off state of the orthogonal channel noise simulator channel (OCNS). See
Downlink Code Channel Information
.
The OCNS channel on/off state is set using the
CALL:OCNSource
commands.
The optional [:SELected] keyword in this command specifies that the OCNS channel state being queried applies to the current system type.
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:OCNSource:STATe?"
|
CALL:STATus:OCNSource:CELL2[:LEVel]([:SELected]|:FDD)?
|
Function
|
Queries the cell 2 orthogonal channel noise source (OCNS) level for the selected system type. See
Downlink Code Channel Information
.
The OCNS level is set using the
CALL:CELL2:OCNSource
commands.
The optional [:SELected] keyword in this command specifies that the OCNS channel level being queried applies to the current system type.
(See
Cell 2 Overview
).
|
|
Query
|
Range: 0 to -20 dB, 9.91 E+37
Resolution: 0.01 dB
|
|
*RST Setting
|
9.91E+37 |
|
Requirements
|
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:OCNSource:CELL2?"
|
CALL:STATus:OCNSource:CELL2:STATe([:SELected]|:FDD)?
|
Function
|
Queries the current cell 2 on/off state of the orthogonal channel noise simulator channel (OCNS). See
Downlink Code Channel Information
.
The OCNS channel on/off state is set using the
CALL:CELL2:OCNSource
commands.
The optional [:SELected] keyword in this command specifies that the OCNS channel state being queried applies to the current system type.
(See
Cell 2 Overview
).
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off) |
|
Requirements
|
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:OCNSource:CELL2:STATe?"
|
CALL:STATus:PICHannel[:CELL][:LEVel]?
|
Function
|
Queries the current downlink page indicator channel's power. See
Downlink Code Channel Information
.
|
|
Query
|
Range: -20.00 to 0 dB, 9.91 E+37
Resolution: 0.01 dB
|
|
*RST Setting
|
-8.3 dB |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
Test Application Revision A.06 changed *RST Setting to -8.3 dB.
Lab Application Revision C.01 changed *RST Setting to -8.3 dB.
|
|
Programming Example
OUTPUT 714;"CALL:STATus:PICHannel?"
|
CALL:STATus:PICHannel[:CELL]:STATe?
|
Function
|
Queries the current state of the downlink page indicator channel. See
Downlink Code Channel Information
.
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:PICHannel:STATe?"
|
CALL:STATus:PRAChannel[:CELL]:CURCbeta?
|
Function
|
Queries the current power gain for the control data of the message portion of the uplink physical random access channel (PRACH) see
PRACH Bc/Bd Control
.
|
|
Query
|
Range: 2 to 15
Resolution: 1
|
|
*RST Setting
|
15 |
|
Requirements
|
Test Application Revision: A.03 and above
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:PRAChannel:CURCbeta?"
|
CALL:STATus:PRAChannel[:CELL]:CURDbeta?
|
Function
|
Queries the current power gain for the message data of the message portion of the uplink physical random access channel (PRACH) see
PRACH Bc/Bd Control
.
|
|
Query
|
Range: 0 to 15
Resolution: 1
|
|
*RST Setting
|
15 |
|
Requirements
|
Test Application Revision: A.03 and above
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:PRAChannel:CURDbeta?"
|
CALL:STATus:REPorted:CQI:LIMitation:COUNt?
|
Function
|
Queries the Count of Reported CQI Limitations. This result counts how many times the Maximum Allowed CQI Value is used instead of using reported CQI to avoid code collision.
|
|
Query
|
Range: 0 to 1,500,000, 9.91 E+37
Resolution: 1
|
|
*RST Setting
|
9.91 E+37 |
|
Requirements
|
Lab Application Revision: F.00 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:REPorted:CQI:LIMitation:COUNt?"
|
CALL:STATus:ROHC:DOWNlink:CID:LARGe?
|
Function
|
Queries the Current Downlink ROHC Large CIDs.
This result is inferred from the "Current Downlink ROHC Max CID". If the "Current Downlink ROHC Max CID" is greater than 15, then this result is "True", otherwise this result is "False".
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:STATus:ROHC:DOWNlink:CID:LARGe?"
|
CALL:STATus:ROHC:DOWNlink:CID:MAXimum?
|
Function
|
Queries the Current Downlink ROHC Max CID.
|
|
Query
|
Range: 1 to 16383
Resolution: 1
|
|
*RST Setting
|
15 |
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:STATus:ROHC:DOWNlink:CID:MAXimum?"
|
CALL:STATus:ROHC:DOWNlink:RDDepth?
|
Function
|
Queries the Current Downlink Reverse Decompression Depth.
|
|
Query
|
Range: 0 to 65535
Resolution: 1
|
|
*RST Setting
|
0 |
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:STATus:ROHC:DOWNlink:RDDepth?"
|
CALL:STATus:ROHC:UPLink:CID:LARGe?
|
Function
|
Queries the Current Uplink ROHC Large CIDs.
This result is inferred from the "Current Uplink ROHC Max CID". If the "Current Uplink ROHC Max CID" is greater than 15, then this result is "True", otherwise this result is "False".
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 |
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:STATus:ROHC:UPLink:CID:LARGe?"
|
CALL:STATus:ROHC:UPLink:CID:MAXimum?
|
Function
|
Queries the Current Uplink ROHC Max CID.
|
|
Query
|
Range: 1 to 16383
Resolution: 1
|
|
*RST Setting
|
15 |
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"CALL:STATus:REPorted:CQI:LIMitation:COUNt?"
|
CALL:STATus:RRC:STATe?
|
Function
|
Queries
RRC State
.
|
|
Query
|
Range: DCH|FACH|IDLE
|
|
*RST Setting
|
IDLE |
|
Requirements
|
Lab Application Revision: B.01 and above. |
|
Programming Example
OUTPUT 714;"CALL:STATus:RRC:STATe?"
|
CALL:STATus:SERVice:TYPe?
|
Function
|
Queries the
Current Service Type
.
The current service type will be set to NONE when an event occurs that causes the service to be stopped. These events include:
-
End Call
-
A call processing error that results in a dropped call
-
UE initiated end of service
-
Full or Partial Preset
|
|
Query
|
Range:
-
AMR: AMR Voice
-
AHSP: AMR Voice + PS Data - HSPA
(only applicable to the lab application)
-
APSD: AMR +PS Data
(only applicable to the lab application)
-
CSDA: CS Data - Async (
only applicable to the lab application
)
-
CSDV: CS Data - Video Call (
only applicable to the lab application and to a test application with the required feature license
)
-
GPRS: UMTS/GPRS Packet Data (
only applicable to the lab application
)
-
PHSP: UMTS/GPRS Packet Data - HSPA (
only applicable to the lab application
)
-
PSDH: UMTS/GPRS Packet Data - HSDPA (
only applicable to the lab application
)
-
RBT: RB Test Mode
-
RBTH: RB Test Mode - HSDPA (
only applicable to the lab application and to a test application with the required feature license
)
-
RHSP: RB Test Mode - HSPA (
only applicable to the test application with the required feature license
)
-
MMC: Mobile Management connection (
only applicable to the lab application
)
-
NONE
|
|
*RST Setting
|
NONE |
|
Requirements
|
Test Application Revision: A.01 and above
Test Application Revision A.04 added AMR
Test Application Revision A.06 with the required feature license, added CSDV
Test Application Revision A.08.20 added RBTH
Test Application Revision A.12 with the required feature license and Lab Application Revision E.00.16, added RHSP
Lab Application Revision: A.01 and above
Lab Application Revision A.02 added AMR
Lab Application Revision C.01 added CSDV
Lab Application Revision C.03 added RBTH
Lab Application Revision D.00 added PSDH
Lab Application Revision E.00.16 added APSD
Lab Application Revision U.00.13 added PHSP
Lab Application Revision U.00.31 added AHSP
Lab Application Revision F.00 and above added MMC
|
|
Programming Example
OUTPUT 714;"CALL:STATus:SERVice:TYPe?"
! Returns the current service type.
|
CALL:STATus:SETup[:PCReconfig]:CHANnel<[:SELected]|:FDD>UPLink[:CHANnel]?
CALL:STATus:SETup[:PCReconfig]:CHANnel<[:SELected]|:FDD>UPLink:SEParation?
|
Function
|
Queries the
PCR Info, DL/UL Frequency Separation
.
|
|
Query
|
Range: MHZ30|MHZ31|MHZ45|MHZ48|MHZ80|MHZ95|MHZ120|MHZ190|MHZ400|NSTD
|
|
*RST Setting
|
MHZ190 |
|
Requirements
|
Test Application Revision: A.09 and above
Test Application Revision A.10.01, added MHZ120
Test Application Revision A.11, added [:PCReconfig]
Lab Application Revision: C.04 and above
Lab Application Revision: D.00 and above
Lab Application Revision D.01.01, added MHZ120
Lab Application Revision D.02, added [:PCReconfig]
Lab Application Revision E.00.34, added MHZ48
Test Application Revision A.14 and Lab Application Revision F.00, added MHZ30 and MHZ31
|
|
Programming Example
OUTPUT 714;"CALL:STATus:SETup:CHANnel:UPLink:SEParation?"
|
CALL:STATus:SETup[:PCReconfig]:FBINdicator?
|
Function
|
Queries the
PCR Info, Frequency Band
.
|
|
Query
|
Range: BAND1|BAND2|BAND3|BAND4|BAND5|BAND6|BAND7|BAND8|BAND9|BAND10|
BAND11|BAND12|BAND13|BAND14
|
|
*RST Setting
|
BAND1 |
|
Requirements
|
Test Application Revision: A.09 and above
Lab Application Revisions: C.04 and D.00 and above
Test Application Revision A.10.01 and Lab Application Revision D.01.01, added BAND7
Test Application Revision A.11 and Lab Application Revisions D.02 and E.00, added BAND10
Test Application Revision A.11 and Lab Application Revision D.02, added [:PCReconfig]
Test Application Revision A.13 and Lab Application Revision E.00.34, added BAND11
Test Application Revision A.14 and Lab Application Revision F.00, added BAND12, BAND13, and BAND14
|
|
Programming Example
OUTPUT 714;"CALL:STATus:SETup:FBINdicator?"
|
CALL:STATus:SETup:RBReconfig:CHANnel:UPLink[:CHANnel]?
|
Function
|
Queries
RBR Info, UL: Channel and Frequency
.
|
|
Query
|
Range: see
CALL:SETup:RBReconfig:CHANnel:UPLink:CHANnel
|
|
*RST Setting
|
see
CALL:SETup:RBReconfig:CHANnel:UPLink:CHANnel
|
|
Requirements
|
Test Application Revision A.11 and Lab Application Revision D.02 and above
Lab Application Revision: E.00.34 and above, added 3487 - 3587.
Test Application Revision A.14 and Lab Application Revision F.00 and above, added 3612 - 3678, 3702, 3707, 3732, 3737, 3762, 3767, 3792 - 3818, 3842, 3867, 3892 - 3918, 3942, 3967
|
|
Programming Example
OUTPUT 714;"CALL:STATus:SETup:RBReconfig:CHANnel:UPLink?"
|
CALL:STATus:SETup:RBReconfig:CHANnel:UPLink:SEParation?
|
Function
|
Queries
RBR Info, DL/UL Frequency Separation
.
|
|
Query
|
Range: MHZ30|MHZ31|MHZ45|MHZ48|MHZ80|MHZ95|MHZ120|MHZ190|MHZ400|NSTD
|
|
*RST Setting
|
MHZ190 |
|
Requirements
|
Test Application Revision A.11 and Lab Application Revision D.02 and above
Lab Application Revision E.00.34, added MHZ48
Test Application Revision A.14 and Lab Application Revision F.00, added MHZ30 and MHZ31
|
|
Programming Example
OUTPUT 714;"CALL:STATus:SETup:RBReconfig:CHANnel:UPLink:SEParation?"
|
CALL:STATus:SETup:RBReconfig:DPCHannel:CBETa?
|
Function
|
Queries the beta
c
value that the test set will signal to the UE during the Radio Bearer Reconfiguration (see
RBR Uplink DPCH Bc/Bd Control
). |
|
Query
|
Range: 1 to 15
Resolution: 1
|
|
*RST Setting
|
8 |
|
Requirements
|
Test Application Revision: A.09 and above
Lab Application Revision: C.04 and above
Lab Application Revision: D.00 and above
Test Application Revision A.11 and Lab Application Revisions D.02 and E.00, range is 1 to 15 (vs. 2 to 15)
|
|
Programming Example
OUTPUT 714;"CALL:STATus:SETup:RBReconfig:DPCHannel:CBETa?"
|
CALL:STATus:SETup:RBReconfig:DPCHannel:DBETa?
|
Function
|
Queries the beta
d
value that the test set will signal to the UE during the Radio Bearer Reconfiguration (see
RBR Uplink DPCH Bc/Bd Control
). |
|
Query
|
Range: 0 to 15
Resolution: 1
|
|
*RST Setting
|
15 |
|
Requirements
|
Test Application Revision: A.09 and above
Lab Application Revision: C.04 and above
Lab Application Revision: D.00 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:SETup:RBReconfig:DPCHannel:DBETa?"
|
CALL:STATus:SETup:RBReconfig:FBINdicator?
|
Function
|
Queries
RBR Info, Frequency Band
.
|
|
Query
|
Range: BAND1|BAND2|BAND3|BAND4|BAND5|BAND6|BAND7|BAND8|BAND9|BAND10|
BAND11|BAND12|BAND13|BAND14
|
|
*RST Setting
|
BAND1 |
|
Requirements
|
Test Application Revision A.11 and Lab Application Revision D.02 and above
Lab Application Revision: E.00.34 and above, added BAND11
Test Application Revision A.14 and Lab Application Revision F.00, added BAND12, BAND13, and BAND14
|
|
Programming Example
OUTPUT 714;"CALL:STATus:SETup:RBReconfig:FBINdicator?"
|
CALL:STATus:SETup:TCReconfig:CHANnel:UPLink[:CHANnel]?
|
Function
|
Queries
TCR Info, UL: Channel and Frequency
.
|
|
Query
|
Range: see
CALL:SETup:TCReconfig:CHANnel:UPLink:CHANnel
|
|
*RST Setting
|
see
CALL:SETup:TCReconfig:CHANnel:UPLink:CHANnel
|
|
Requirements
|
Test Application Revision A.11 and Lab Application Revision D.02 and above
Lab Application Revision: E.00.34 and above, added 3487 - 3587.
Test Application Revision A.14 and Lab Application Revision F.00 and above, added 3612 - 3678, 3702, 3707, 3732, 3737, 3762, 3767, 3792 - 3818, 3842, 3867, 3892 - 3918, 3942, 3967
|
|
Programming Example
OUTPUT 714;"CALL:STATus:SETup:TCReconfig:CHANnel:UPLink?"
|
CALL:STATus:SETup:TCReconfig:CHANnel:UPLink:SEParation?
|
Function
|
Queries
TCR Info, DL/UL Frequency Separation
.
|
|
Query
|
Range: MHZ30|MHZ31|MHZ45|MHZ48|MHZ80|MHZ95|MHZ120|MHZ190|MHZ400|NSTD
|
|
*RST Setting
|
MHZ190 |
|
Requirements
|
Test Application Revision A.11 and Lab Application Revision D.02 and above
Lab Application Revision E.00.34, added MHZ48
Test Application Revision A.14 and Lab Application Revision F.00, added MHZ30 and MHZ31
|
|
Programming Example
OUTPUT 714;"CALL:STATus:SETup:TCReconfig:CHANnel:UPLink:SEParation?"
|
CALL:STATus:SETup:TCReconfig:DPCHannel:CBETa?
|
Function
|
Queries the beta
c
value that the test set will signal to the UE during the Transport Channel Reconfiguration (see
TCR DPCH Bc/Bd Control
). |
|
Query
|
Range: 1 to 15
Resolution: 1
|
|
*RST Setting
|
8 |
|
Requirements
|
Test Application Revision: A.09 and above
Lab Application Revision: C.04 and above
Lab Application Revision: D.00 and above
Test Application Revision A.11 and Lab Application Revisions D.02 and E.00, range is 1 to 15 (vs. 2 to 15)
|
|
Programming Example
OUTPUT 714;"CALL:STATus:SETup:TCReconfig:DPCHannel:CBETa?"
|
CALL:STATus:SETup:TCReconfig:DPCHannel:DBETa?
|
Function
|
Queries the beta
d
value that the test set will signal to the UE during the Transport Channel Reconfiguration (see
TCR DPCH Bc/Bd Control
). |
|
Query
|
Range: 0 to 15
Resolution: 1
|
|
*RST Setting
|
15 |
|
Requirements
|
Test Application Revision: A.09 and above
Lab Application Revision: C.04 and above
Lab Application Revision: D.00 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:SETup:TCReconfig:DPCHannel:DBETa?"
|
CALL:STATus:SETup:TCReconfig:FBINdicator?
|
Function
|
Queries
TCR Info, Frequency Band
.
|
|
Query
|
Range: BAND1|BAND2|BAND3|BAND4|BAND5|BAND6|BAND7|BAND8|BAND9|BAND10|
BAND11|BAND12|BAND13|BAND14
|
|
*RST Setting
|
BAND1 |
|
Requirements
|
Test Application Revision A.11 and Lab Application Revision D.02 and above
Test Application Revision A.13 and Lab Application Revision E.00.34 and above, added BAND11
Test Application Revision A.14 and Lab Application Revision F.00, added BAND12, BAND13, and BAND14
|
|
Programming Example
OUTPUT 714;"CALL:STATus:SETup:TCReconfig:FBINdicator?"
|
CALL:STATus:SGRant:RELative:QUEued:COUNt?
|
Function
|
Queries
Queued Relative Grants
.
|
|
Query
|
Range: 0 to 1000
|
|
*RST Setting
|
0 |
|
Requirements
|
Test Application Revision A.12 and above, with the required feature license
Lab Application Revision E.00.16 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:SGRant:RELative:QUEued:COUNt?"
|
CALL:STATus:SHANdoff:EVENt?
|
Function
|
Queries the most recent Intra Frequency Event identifier. Events can be:
(See
Event Reporting
).
|
|
Query
|
Range: 1A|1B|1C|1D|1E|1F|NONE
|
|
*RST Setting
|
NONE |
|
Requirements
|
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:SHANdoff:EVENt?" !Returns the most recent event.
|
CALL:STATus:SHANdoff:EVENt:CELLid?
|
Function
|
Queries the cell that triggered the most recent event. (See
Event Reporting
). |
|
Query
|
Range: CELL1|CELL2|NONE
|
|
*RST Setting
|
NONE |
|
Requirements
|
Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:SHANdoff:EVENt:CELLid?"
|
CALL:STATus:SHANdoff:STATe?
|
Function
|
Queries
Soft Handover State
. |
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 |
|
Requirements
|
Lab Application Revision: B.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:SHANdoff:STATe?"
|
CALL:STATus:TOTal:POWer[:AMPLitude]?
|
Function
|
Queries the current total RF power for the specified system type. The total RF power is equal to the sum of the cell power setting (see
CALL:POWer
) and the AWGN setting (see
CALL:AWGNoise
).
See
Cell Power and AWGN Power
for more information about desired versus current power levels.
|
|
Query
|
Range:
Resolution: 0.01 dB
|
|
*RST Setting
|
-75.00 dBm |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:TOTal:POWer?"
|
CALL:STATus:TOTal:POWer:STATe?
|
Function
|
Queries the current total RF power measurement's state for the currently selected system type.
This query will return a 1 (on) if the current cell power (
CALL:POWer
) power state is on.
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
1 (on) |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"CALL:STATus:TOTal:POWer:STATe?"
|
CALL:STATus:UPLink:CHANnel?
CALL:STATus:UPLink:SEParation?
|
Function
|
Queries the
Current Info, DL/UL Frequency Separation
.
|
|
Query
|
Range: MHZ30|MHZ31|MHZ45|MHZ48|MHZ80|MHZ95|MHZ120|MHZ190|MHZ400|NSTD
|
|
*RST Setting
|
MHZ190 |
|
Requirements
|
Test Application Revision: A.08 and above
Lab Application Revision: C.03 and above
Test Application Revision A.10.01 and Lab Application Revision D.01.01 added MHZ120
Lab Application Revision E.00.34, added MHZ48
Test Application Revision A.14 and Lab Application Revision F.00, added MHZ30 and MHZ31
|
|
Programming Example
OUTPUT 714;"CALL:STATus:UPLink:SEParation?"
|
|
|