FETCh:EVMQpsk
Last updated: May 26, 2009
GPIB Command Conventions
FETCh:EVMQpsk[:ALL]?
|
Function
|
Queries the QPSK EVM measurements.
Measurement results are returned in the following order: integrity, EVM maximum, frequency error worst case, origin offset maximum, phase error maximum, magnitude error maximum, peak EVM maximum.
|
|
Query
|
Integrity
-
Range: 0 to 16
-
Resolution: 1
EVM Maximum
Frequency Error worst case
Origin Offset Maximum
Phase Error Maximum
Magnitude Error Maximum
Peak EVM Maximum
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk?"
|
FETCh:EVMQpsk:EVM[:MAXimum]?
|
Function
|
Queries the maximum EVM.
|
|
Query
|
Range: 0 to 99%, 9.91 E+37
Resolution: 0.1
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:EVM?"
! Returns maximum EVM.
|
FETCh:EVMQpsk:EVM:ALL?
|
Function
|
Queries the EVM measurements.
Results are returned in the following order: minimum, maximum, average, standard deviation error vector magnitude.
|
|
Query
|
Minimum EVM
Maximum EVM
Average EVM
Standard Deviation EVM
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:EVM:ALL?"
! Returns all EVM measurement results.
|
FETCh:EVMQpsk:EVM:AVERage?
|
Function
|
Queries the average EVM.
|
|
Query
|
Range: 0 to 99%, 9.91 E+37
Resolution: 0.1
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:EVM:AVERage?"
! Returns average EVM.
|
FETCh:EVMQpsk:EVM:MINimum?
|
Function
|
Queries the minimum EVM.
|
|
Query
|
Range: 0 to 99%, 9.91 E+37
Resolution: 0.1
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:EVM:MINimum?"
! Returns mininum EVM.
|
FETCh:EVMQpsk:EVM:PEAK<[:MAXimum]|:ALL|:AVERage|:MINimum|:SDEViation>?
|
Function
|
Queries the QPSK EVM measurement results and returns the following, depending upon which mnemonic is sent at the end of the command string:
-
[:MAXimum] - returns the maximum peak EVM result when
Multi-Measurement Count
is on or peak EVM when
Multi-Measurement Count
=
Off
.
-
:ALL - returns the minimum, maximum, average and standard deviation peak EVM results when
Multi-Measurement Count
is on (it returns peak EVM, peak EVM, peak EVM and zero when
Multi-Measurement Count
is off).
-
:AVERage - returns the average peak EVM result when
Multi-Measurement Count
is on (it returns peak EVM when
Multi-Measurement Count
is off).
-
:MINimum - returns the minimum peak EVM result when
Multi-Measurement Count
is on (it returns peak EVM when
Multi-Measurement Count
is off).
-
:SDEViation - returns the standard deviation of the peak EVM results when
Multi-Measurement Count
is on (it returns zero when
Multi-Measurement Count
is off).
|
|
Query
|
Range:
-
Peak EVM: 0 to 99.0%, 9.91E+37
-
Standard deviation: 0 to 99.00%, 9.91E+37
Resolution:
-
Peak EVM: 0.1%
-
Standard deviation: 0.01%
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:EVM:PEAK?"
! Returns peak EVM (or maximum peak EVM if multi-measurement count is on)
OUTPUT 714;"FETCh:EVMQpsk:EVM:PEAK:ALL?"
! Returns minimum, maximum, average and standard deviation peak EVM when multi-measurement
! count is on (it returns peak EVM, peak EVM, peak EVM and zero when multi-measurement
! count is off).
|
FETCh:EVMQpsk:EVM:SDEViation?
|
Function
|
Queries the standard deviation of results for EVM measurements.
|
|
Query
|
Range: 0 to 99%, 9.91 E+37
Resolution: 0.01
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:EVM:SDEViation?"
! Returns standard deviation EVM.
|
FETCh:EVMQpsk:FERRor[:WORSt]?
|
Function
|
Queries the worst case frequency error. (The test set returns either the Minimum or Maximum Frequency Error result, whichever is furthest from zero).
|
|
Query
|
Range: -99 to 99 kHz, 9.91 E+37
Resolution: 0.1
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:FERRor?"
! Returns worst case frequency error.
|
FETCh:EVMQpsk:FERRor:ALL?
|
Function
|
Queries the frequency error measurements.
Results are returned in the following order: minimum, maximum, average, standard deviation and worst case frequency error.
|
|
Query
|
Minimum Frequency Error
Maximum Frequency Error
Average Frequency Error
Standard Deviation Frequency Error
Worst Case Frequency Error
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:FERRor:ALL?"
! Returns mininum, maximum, average,
! standard deviation and worst case frequency error.
|
FETCh:EVMQpsk:FERRor:AVERage?
|
Function
|
Queries the average frequency error.
|
|
Query
|
Range: -99 to 99 kHz, 9.91 E+37
Resolution: 0.1
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:FERRor:AVERage?"
! Returns average frequency error.
|
FETCh:EVMQpsk:FERRor:MAXimum?
|
Function
|
Queries the average frequency error.
|
|
Query
|
Range: -99 to 99 kHz, 9.91 E+37
Resolution: 0.1
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:FERRor:MAXimum?"
! Returns maximum frequency error.
|
FETCh:EVMQpsk:FERRor:MINimum?
|
Function
|
Queries the minimum frequency error.
|
|
Query
|
Range: -99 to 99 kHz, 9.91 E+37
Resolution: 0.1
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:FERRor:MINimum?"
! Returns minimum frequency error.
|
FETCh:EVMQpsk:FERRor:SDEViation?
|
Function
|
Queries the standard deviation of frequency error measurements.
|
|
Query
|
Range: 0 to 99 kHz, 9.91 E+37
Resolution: 0.01
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:FERRor:SDEViation?"
! Returns standard deviation frequency error.
|
FETCh:EVMQpsk:ICOunt?
|
Function
|
Queries the intermediate count of measurements completed in a multi-measurement.
|
|
Query
|
Range: 0 to 999
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:ICOunt?"
|
FETCh:EVMQpsk:INTegrity?
|
Function
|
Queries the measurement integrity indicator for the last waveform quality measurement completed.
Zero indicates a normal measurement. See
Integrity Indicator
for information about non-zero integrity results.
|
|
Query
|
Range: 0 through 23
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:INTegrity?"
!Queries the integrity indicator for the channel channel power results.
|
FETCh:EVMQpsk:MERRor[:MAXimum]?
|
Function
|
Queries the average magnitude error.
|
|
Query
|
Range: 0 to 99%
Resolution: 0.1
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:MERRor?"
! Returns maximum magnitude error.
|
FETCh:EVMQpsk:MERRor:ALL?
|
Function
|
Queries the magnitude error measurements.
Results are returned in the following order: minimum, maximum, average, standard deviation magnitude error.
|
|
Query
|
Minimum Magnitude Error
Maximum Magnitude Error
Average Magnitude Error
Standard Deviation Magnitude Error
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh::EVMQpsk:MERRor:ALL?"
! Returns mininum, maximum, average, and
! standard deviation magnitude error.
|
FETCh:EVMQpsk:MERRor:AVERage?
|
Function
|
Queries the average magnitude error.
|
|
Query
|
Range: 0 to 99%
Resolution: 0.1
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:MERRor:AVERage?"
! Returns average magnitude error.
|
FETCh:EVMQpsk:MERRor:MINimum?
|
Function
|
Queries the minimum magnitude error.
|
|
Query
|
Range: 0 to 99%
Resolution: 0.1
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:MERRor:MINimum?"
! Returns minimum magnitude error.
|
FETCh:EVMQpsk:MERRor:SDEViation?
|
Function
|
Queries the standard deviation of magnitude error measurements.
|
|
Query
|
Range: 0 to 99%
Resolution: 0.01
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:MERRor:SDEViation?"
! Returns standard deviation magnitude error.
|
FETCh:EVMQpsk:OOFFset[:MAXimum]?
|
Function
|
Queries the average origin offset.
|
|
Query
|
Range:-99 to 0 dB, 9.91 E+37
Resolution: 0.1
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:OOFFset?"
! Returns maximum origin offset.
|
FETCh:EVMQpsk:OOFFset:ALL?
|
Function
|
Queries the origin offset measurements.
Results are returned in the following order: minimum, maximum, average, standard deviation origin offset.
|
|
Query
|
Minimum Origin Offset
Maximum Origin Offset
Average Origin Offset
Standard Deviation Origin Offset
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:OOFFset:ALL?"
! Returns mininum, maximum, average, and
! standard deviation origin offset.
|
FETCh:EVMQpsk:OOFFset:AVERage?
|
Function
|
Queries the average origin offset.
|
|
Query
|
Range: -99 to 0 dB, 9.91 E+37
Resolution: 0.1
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:OOFFset:AVERage?"
! Returns average origin offset.
|
FETCh:EVMQpsk:OOFFset:MINimum?
|
Function
|
Queries the minimum origin offset.
|
|
Query
|
Range:-99 to 0 dB, 9.91 E+37
Resolution: 0.1
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:OOFFset:MINimum?"
! Returns minimum origin offset.
|
FETCh:EVMQpsk:OOFFset:SDEViation?
|
Function
|
Queries the standard deviation of results for origin offset measurements.
|
|
Query
|
Range: 0 to 99 dB, 9.91 E+37
Resolution: 0.01
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:OOFFset:SDEViation?"
! Returns standard deviation origin offset.
|
FETCh:EVMQpsk:PERRor[:MAXimum]?
|
Function
|
Queries the maximum phase error measurement.
|
|
Query
|
Range: 0 to 180 degrees, 9.91 E+37
Resolution: 0.1
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:PERRor?"
! Returns maximum phase error.
|
FETCh:EVMQpsk:PERRor:ALL?
|
Function
|
Queries the phase error measurements.
Results are returned in the following order: minimum, maximum, average, standard deviation phase error.
|
|
Query
|
Minimum Phase Error
Maximum Phase Error
Average Phase Error
Standard Deviation Phase Error
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:PERRor:ALL?"
! Returns mininum, maximum, average, and
! standard deviation phase error.
|
FETCh:EVMQpsk:PERRor:AVERage?
|
Function
|
Queries the average phase error.
|
|
Query
|
Range: 0 to 180 degrees, 9.91 E+37
Resolution: 0.1
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:PERRor:AVERage?"
! Returns average phase error.
|
FETCh:EVMQpsk:PERRor:MINimum?
|
Function
|
Queries the minimum phase error.
|
|
Query
|
Range: 0 to 180 degrees, 9.91 E+37
Resolution: 0.1
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:PERRor:MINimum?"
! Returns minimum phase error.
|
FETCh:EVMQpsk:PERRor:SDEViation?
|
Function
|
Queries the standard deviation of results for phase error measurements.
|
|
Query
|
Range: 0 to 180 degrees, 9.91 E+37
Resolution: 0.01
|
|
Requirements
|
Lab Application Revision: F.00.19 and above |
|
Programming Example
OUTPUT 714;"FETCh:EVMQpsk:PERRor:SDEViation?"
! Returns standard deviation phase error.
|
|
|