FETCh:WTDPower[:ALL]?
|
Function
|
Queries the TX dynamic power measurement results.
This query returns 101 comma-separated values, in the order of an integrity value, followed by 100 power results.
The FETCh:WTDPower[:ALL] query always returns 101 power results, regardless of how many power measurements were performed by the test set when the measurement was executed. The number of power measurements performed by the test set is equal to the
Number of Power Steps
setting + 1, and can be queried using the
FETCh:WTDPower:COUNt[:STEP]?
command. If fewer than 100 power measurements were performed by the test set, the remaining power results are returned as 9.91 E+37.
|
|
Query
|
-
Power
-
Range: -100.00 to 100.00 dBm, 9.91 E+37
-
Resolution: 0.01 dB
|
|
Requirements
|
Test Application Revision: A.07 and above
Lab Application Revision: C.02 and above
|
|
Programming Example
OUTPUT 714;"FETCh:WTDPower?"
! Returns integrity, 100 power results.
|
FETCh:WTDPower:COUNt[:STEP]?
|
Function
|
Queries the number of
Power
measurements performed by the test set. The power measurement values can be queried using the
FETCh:WTDPower[:ALL]?
command.
The number of power measurements performed by the test set is equal to the
Number of Power Steps
setting + 1.
|
|
Query
|
Range: 0 to 100
Resolution: 1
|
|
Requirements
|
Test Application Revision: A.07 and above
Lab Application Revision: C.02 and above
|
|
Programming Example
OUTPUT 714;"FETCh:WTDPower:COUNt?"
! Returns the number of power measurements performed by the test set.
|
FETCh:WTDPower:INTegrity?
|
Function
|
Queries the
Integrity Indicator
. Zero indicates a normal measurement.
|
|
Query
|
Range: see
Integrity Indicator
Resolution: 1
|
|
Requirements
|
Test Application Revision: A.07 and above
Lab Application Revision: C.02 and above
|
|
Programming Example
OUTPUT 714;"FETCh:WTDPower:INTegrity?"