RFANalyzer
Last updated: January 16, 2009
GPIB Command Conventions
RFANalyzer:CONTrol:MEASurement:FREQuency:AUTO
|
Function
|
Turns on/off the auto
Measurement Frequency
feature which determines the measurement downconverter signal path frequency control mode. (See
Block Diagram
.)
ON = automatic
OFF = manual (see
RFANalyzer:MANual:MEASurement[:MFRequency]
and
RFANalyzer:MANual:MEASurement:FREQuency
)
Note, when you switch between operating modes,
Measurement Frequency
is returned to its default value of
Auto
.
|
|
Setting
|
Range: 1|ON|0|OFF |
|
Query
|
Range: 1|0
|
|
*RST setting |
1 (on) |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"RFANalyzer:CONTrol:MEASurement:FREQuency:AUTO OFF"
!Enables manual control of the measurement signal path tune frequency.
|
RFANalyzer:CONTrol:POWer:AUTO
|
Function
|
Sets/queries
Power Control
.
ON = automatic
OFF = manual (see
RFANalyzer:MANual:POWer[:SELected]
)
This command is available in
Active Cell
,
FDD Test
and
Cell Off
operating modes.
Note, when you switch between operating modes,
Power Control
is returned to its default value of
Auto
.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST setting |
1 (on) |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"RFANALYZER:CONTROL:POWER:AUTO OFF"
!Enables manual control of the expected input power level.
|
RFANalyzer:CONTrol:UPLink:FREQuency:AUTO
|
Function
|
Turns on/off the auto
Uplink Frequency
feature, which determines the test set's demodulation signal path tune frequency control mode.
ON = automatic
OFF = manual (see
RFANalyzer:MANual:UPLink[:MFRequency]
and
RFANalyzer:MANual:UPLink:FREQuency
.
This setting is available in FDD Test and CW operating modes.
Note, when you switch between operating modes,
Uplink Frequency
is returned to its default value of
Auto
.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST setting |
1 (on) |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"RFANALYZER:CONTROL:UPLINK:FREQUENCY:AUTO OFF" !Enables manual control of the demodulation signal path tune frequency.
|
RFANalyzer:CW:EXPected:POWer
|
Function
|
Sets/queries the expected CW receiver input power. This setting is only used when the Operating Mode is set to CW. (See
CALL:OPERating
.)
|
|
Setting
|
Range: -60 dBm to +53 dBm
|
|
Query
|
Range: -60 dBm to +53 dBm
|
|
*RST setting |
+13 dBm |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"RFANALYZER:CW:EXPECTED:POWER -20"
|
RFANalyzer:MANual:POWer[:SELected]
|
Function
|
Sets/queries
Manual Power
(the optional [:SELected] keyword in this command specifies that the manual power setting applies to the current system type). This command is only applicable when
RFANalyzer:CONTrol:POWer:AUTO
(
Power Control
) is set to
Off
(manual).
This command is available in
Active Cell
,
FDD Test
and
Cell Off
operating modes.
Note, when you switch between operating modes,
Power Control
is returned to its default value of
Auto
.
|
|
Setting
|
Range: Test application and system type dependent (approximately -25 to +43 dBm).
Resolution: 0.01 dBm
|
|
Query
|
Range: Test application and system type dependent (approximately -25 to +43 dBm). |
|
*RST setting |
-75 dBm |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"RFANALYZER:MANUAL:POWER:SELECTED 24 DBM" !Sets the manual power control mode expected input power level for the currently selected system type to 24 dBm.
|
RFANalyzer:MANual:POWer:FDD
|
Function
|
Sets/queries
Manual Power
when UTRA FDD is the current system type. This command is only applicable when
RFANalyzer:CONTrol:POWer:AUTO
(
Power Control
) is set to
Off
(manual).
This command is available in
Active Cell
,
FDD Test
and
Cell Off
operating modes.
Note, when you switch between operating modes,
Power Control
is returned to its default value of
Auto
.
|
|
Setting
|
Range: -129 to +80 dBm (-79 dBm to +30 dBm actual hardware range with amplitude offset = 0)
Resolution: 0.01 dBm
|
|
Query
|
Range: -129 to +80 dBm (-79 dBm to +30 dBm actual hardware range with amplitude offset = 0) |
|
*RST setting |
0 dBm |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"RFANALYZER:MANUAL:POWER:FDD 24 DBM"
!Sets the manual power control mode expected input power level for the FDD system type to
!24 dBm.
|
RFANalyzer:MANual:MEASurement[:MFRequency]
|
Function
|
The setting form of this command performs two functions: (1) sets
Measurement Frequency
, the tune frequency of the test set's measurement signal path, and (2) selects manual (auto off) tune mode for the test set's measurement signal path.
The query form of this command returns the tune frequency of the test set's measurement signal path.
The tune mode for the test set's measurement signal path can be returned to auto using the
RFANalyzer:CONTrol:MEASurement:FREQuency:AUTO
command.
Note, when you switch between operating modes,
Measurement Frequency
is returned to its default value of
Auto
.
|
|
Setting
|
Range: 292.5 MHz to 2700 MHz
Resolution: 0.1 Hz
|
|
Query
|
Range: 292.5 MHz to 2700 MHz |
|
*RST setting |
896 MHz |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"RFANALYZER:MANUAL:MEASUREMENT:MFREQUENCY 942.6 MHZ"
!Enables manual control of the measurement signal path tune frequency and sets the tune frequency to 942.6 MHz.
|
RFANalyzer:MANual:MEASurement:FREQuency
|
Function
|
Sets/queries
Measurement Frequency
.
This setting is applied when manual mode is selected for
Measurement Frequency
(see
RFANalyzer:CONTrol:MEASurement:FREQuency:AUTO
).
Note, when you switch between operating modes,
Measurement Frequency
is returned to its default value of
Auto
.
|
|
Setting
|
Range: 292.5 MHz to 2700 MHz
Resolution: 0.1 Hz
|
|
Query
|
Range: 292.5 MHz to 2700 MHz |
|
*RST setting |
896 MHz |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"RFANALYZER:MANUAL:MEASUREMENT:FREQUENCY 942.6 MHZ"
!Sets the measurement signal path tune frequency to 942.6 MHz when manual control mode is used.
|
RFANalyzer:MANual:UPLink[:MFRequency]
|
Function
|
The setting form of this command performs two functions: (1) sets
Uplink Frequency
, the tune frequency of the test set's demodulation signal path, and (2) selects manual (auto off) tune mode for the test set's demodulation signal path.
The query form of this command returns the tune frequency of the test set's demodulation signal path.
The tune mode for the test set's demodulation path can be returned to auto using the
RFANalyzer:CONTrol:UPLink:FREQuency:AUTO
command.
This setting is available in FDD Test and CW operating modes.
Note, when you switch between operating modes,
Uplink Frequency
is returned to its default value of
Auto
.
|
|
Setting
|
Range: 292.5 MHz to 2700 MHz
Resolution: 0.1 Hz
|
|
Query
|
Range: 292.5 MHz to 2700 MHz |
|
*RST setting |
896 MHz |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"RFANALYZER:MANUAL:UPLINK:MFREQUENCY 1955.030 MHZ"
!Enables manual control of the demodulation signal path tune frequency and sets the tune frequency
!to 1955.030 MHz.
|
RFANalyzer:MANual:UPLink:FREQuency
|
Function
|
Sets/queries
Uplink Frequency
.
This setting is applied when manual mode is selected for
Uplink Frequency
(see
RFANalyzer:CONTrol:UPLink:FREQuency:AUTO
).
This setting is available in FDD Test and CW operating modes.
Note, when you switch between operating modes,
Uplink Frequency
is returned to its default value of
Auto
.
|
|
Setting
|
Range: 292.5 MHz to 2700 MHz
Resolution: 0.1 Hz
|
|
Query
|
Range: 292.5 MHz to 2700 MHz
|
|
*RST setting |
896 MHz |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"RFANALYZER:MANUAL:UPLINK:FREQUENCY 942.6 MHZ"
!Sets the test set's demodulation signal path tune frequency to 942.6 MHz.
|
|
|