SETup:WCPower
Last updated: June 9, 2009
GPIB Command Conventions
SETup:WCPower:CONTinuous
|
Function
|
Sets/queries the trigger arm state for the channel power measurement. The trigger arm state determines whether the channel power measurement will be made once then stop (0|OFF (single)), or automatically re-arm upon completion of one measurement and repeat the process (1|ON (continuous)).
See
Channel Power Measurement Description
.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off)
|
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:WCPOWER:CONTINUOUS OFF"
!Sets measurement to single trigger mode.
|
SETup:WCPower:COUNt[:SNUMber]
|
Function
|
The setting form of this command performs two functions: (1) sets the number of channel power measurements to be made in a multi-measurement, and (2) sets the multi-measurement STATe command to 1 (on).
The query form returns the number of channel power multi-measurements to be made when multi-measurement state is ON.
See
Channel Power Measurement Description
.
|
|
Setting
|
Range: 1 to 999
|
|
Query
|
Range: 1 to 999
|
|
*RST Setting
|
Off (10 when STATe = On) |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:WCPOWER:COUNT:SNUMBER 5"
!Turns on multi-measurements and sets the number of measurements to 5.
|
SETup:WCPower:COUNt:NUMBer
|
Function
|
Sets/queries the number of channel power measurements to be made when the multi-measurement state is ON.
See
Channel Power Measurement Description
.
|
|
Setting
|
Range: 1 to 999
|
|
Query
|
Range: 1 to 999
|
|
*RST Setting
|
10 |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:WCPOWER:COUNT:NUMBER 5"
!Sets the number of channel power multi-measurements to 5.
|
SETup:WCPower:COUNt:STATe
|
Function
|
Sets/queries the channel power multi-measurement state.
See
Channel Power Measurement Description
.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off)
|
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:WCPOWER:COUNT:STATE ON" !Turns on channel power multi-measurements.
|
SETup:WCPower:FILTer[:RRC]
|
Function
|
Sets/queries the state of the root-raised cosine (RRC) filter (
RRC Filter
).
|
|
Setting
|
Range: ON|OFF
|
|
Query
|
Range: ON|OFF
|
|
*RST Setting
|
OFF |
|
Requirements
|
Test or Lab Application Revision: A.02 and above
|
|
Programming Example
OUTPUT 714;"SETUP:WCPOWER:FILTER:RRC ON" !Turns on the RRC filter.
|
SETup:WCPower:INTerval:TIME
|
Function
|
Sets/queries the channel power
Measurement Interval
.
|
|
Setting
|
Range: 10 us to 12 ms
Resolution: 1 ns
|
|
Query
|
Same as setting |
|
*RST Setting
|
666.7 us (one slot interval)
|
|
Requirements
|
Test or Lab Application Revision: A.01 and above
Test Application Revision A.08 and Lab Application Revision A.03, increased range to 10 us to 12 ms (previously it was 0.1 ms to 10 ms)
|
|
Programming Example
OUTPUT 714;"SETUP:WCPOWER:INTERVAL:TIME 10MS"
!Sets interval time to 10 milliseconds.
|
SETup:WCPower:POWer:RANGe:OFFSet:MANual
|
Function
|
Sets/queries the channel power
Manual Power Range Offset
setting.
This setting is only applicable when
SETup:WCPower:RANGe:AUTO
is set to off.
|
|
Setting
|
Range: 0.00 to 99.00 dB
Resolution: 0.01 dB
|
|
Query
|
Same as setting. |
|
*RST Setting
|
0 dB
|
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"SETup:WCPower:POWer:RANGe:OFFSet:MANual 0"
! Sets Manual Power Range Offset to 0 dB.
|
SETup:WCPower:RANGe:AUTO
|
Function
|
Sets/queries the channel power
Auto Range
setting.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
1|0 |
|
*RST Setting
|
0 (off)
|
|
Requirements
|
Test Application Revision: A.12 and above
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"SETup:WCPower:RANGe:AUTO OFF"
! Sets Auto Range to Off.
|
SETup:WCPower:RMSCubed:STATe
|
Function
|
Sets/queries the channel power
RMSCubed State
.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
1|0 |
|
*RST Setting
|
0 (off)
|
|
Requirements
|
Test Application Revision: A.12 and above, with the required feature license
Lab Application Revision: E.00.16 and above
|
|
Programming Example
OUTPUT 714;"SETup:WCPower:RMSCubed:STATe OFF"
! Sets RMSCubed State to Off.
|
SETup:WCPower:TIMeout[:STIMe]
|
Function
|
The setting form of this command performs two functions: (1) sets the channel power measurement's timeout (see
Measurement Timeouts
) value, and (2) sets the channel power measurement's timeout STATe to 1 (on).
The query form returns the channel power measurement's timeout value.
See
Channel Power Measurement Description
.
|
|
Setting
|
Range: 0.1 to 999.9 seconds
Resolution: 0.1 second
|
|
Query
|
Range: 0.1 to 999.9
|
|
*RST Setting
|
10 seconds, off
|
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:WCPOWER:TIMEOUT:STIME 5 S"
!Sets timeout state to ON and sets the timeout time to 5 seconds.
|
SETup:WCPower:TIMeout:STATe
|
Function
|
Sets/queries the channel power measurement's timeout (see
Measurement Timeouts
) state.
See
Channel Power Measurement Description
.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off)
|
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:WCPOWER:TIMEOUT:STATE ON"
|
SETup:WCPower:TIMeout:TIME
|
Function
|
Sets/queries the channel power measurement's timeout (see
Measurement Timeouts
) setting to be used when the timeout state is set to ON.
See
Channel Power Measurement Description
.
|
|
Setting
|
Range: 0.1 to 999.9 seconds
Resolution: 0.1 second
|
|
Query
|
Range: 0.1 to 999.9
|
|
*RST Setting
|
10 seconds
|
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:WCPOWER:TIMEOUT:TIME 5 S"
|
SETup:WCPower:TRIGger:ALIGnment:HSDPcchannel:SUBFrame
|
Function
|
Sets/queries the channel power measurement's
HS-DPCCH Trigger Subframe Alignment
setting.
This command is only applicable when
SETup:WCPower:TRIGger:SOURce
is set to
HSDPcchannel
.
|
|
Setting
|
Range: 0 to 5
Resolution: 1
|
|
Query
|
Same as setting |
|
*RST Setting
|
0 (subframe 0) |
|
Requirements
|
Test Application Revision: A.08 and above with the required feature license
Lab Application Revision: A.03 and above
|
|
Programming Example
OUTPUT 714;"SETup:WCPower:TRIGger:ALIGnment:HSDPcchannel:SUBFrame 1"
! Sets HS-DPCCH Trigger Subframe Alignment to subframe 1.
|
SETup:WCPower:TRIGger:DELay
|
Function
|
Sets/queries the channel power measurement's
Trigger Delay
setting.
This setting can be used to delay the measurement trigger in order to start a measurement during a specific timeslot in the frame. For example, a 1.333 ms delay would cause the trigger to wait until after the first two timeslots have elapsed.
|
|
Setting
|
Range: -12 to 12 ms
Resolution: 1 ns
|
|
Query
|
Same as setting |
|
*RST Setting
|
0 seconds
|
|
Requirements
|
Test or Lab Application Revision: A.01 and above
Test Application Revision A.08 and Lab Application Revision A.03, increased range to -12 to 12 ms (previously it was -10 ms to 10 ms)
|
|
Programming Example
OUTPUT 714;"SETUP:WCPOWER:TRIGGER:DELAY 1MS"
|
SETup:WCPower:TRIGger:SOURce
|
Function
|
Sets/queries the channel power measurement's
Trigger Source
.
|
|
Setting
|
Range:
-
AUTO
-
EXTernal
-
HSDPcchannel (feature-licensed test application only)
-
IMMediate
-
PROTocol
-
RISE
|
|
Query
|
Range:
-
AUTO
-
EXT
-
HSDP (feature-licensed test application only)
-
IMM
-
PROT
-
RISE
|
|
*RST Setting
|
AUTO |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
Test Application Revision A.08 and Lab Application Revision A.03, added EXTernal
Test Application Revision A.08 with the required feature license and Lab Application Revision A.03, added HSDPcchannel
|
|
Programming Example
OUTPUT 714;"SETUP:WCPOWER:TRIGGER:SOURCE IMMEDIATE"
|
|