SETup:WWQuality

Last updated: January 16, 2009

GPIB Command Conventions

SETup:WWQuality:ALIGnment:SFNumber

Function

Sets/queries which frame will be measured when the Even Frame trigger source is selected.

Setting

Range: ODD|EVEN

Query

Range: ODD|EVEN

*RST Setting

EVEN

Requirements

Lab Application Revision F.00, and above.

Test Application Revision: A.14 and above, with the required feature license

Programming Example

 
OUTPUT 714;"SETup:WWQuality:ALIGnment:SFNumber EVEN"

SETup:WWQuality:CONTinuous

Function

Sets/queries the trigger arm state for the waveform quality measurement. The trigger arm state determines whether the waveform quality measurement will be made once then stop (0|OFF (single)), or automatically rearm upon completion of one measurement and repeat the process (1|ON (continuous)).

Setting

Range: 1|ON|0|OFF

Query

Range: 1|0

*RST Setting

0 (off)

Requirements

Test or Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"SETUP:WWQUALITY:CONTINUOUS OFF" 
!Sets measurement to single trigger mode.

SETup:WWQuality:COUNt[:SNUMber]

Function

The setting form of this command performs two functions: (1) sets the number of waveform quality measurements to be made in a multi-measurement, and (2) sets the multi-measurement STATe command to 1 (on).

The query form returns the number of waveform quality multi-measurements to be made when multi-measurement state is ON.

Setting

Range: 1 to 999

Query

Range: 1 to 999

*RST Setting

Off (10 when STATe = On)

Requirements

Test or Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"SETUP:WWQUALITY:COUNT:SNUMBER 5" 
!Turns on multi-measurements and sets the number of measurements to 5.

SETup:WWQuality:COUNt:NUMBer

Function

Sets/queries the number of waveform quality measurements to be made when the multi-measurement state is ON.

Setting

Range: 1 to 999

Query

Range: 1 to 999

*RST Setting

10

Requirements

Test or Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"SETUP:WWQUALITY:COUNT:NUMBER 5" 
!Sets the number of measurements to 5 when the multi-measurement state is set to ON.

SETup:WWQuality:COUNt:STATe

Function

Sets/queries the multi-measurement state of the waveform quality measurement.

Setting

Range: 1|ON|0|OFF

Query

Range: 1|0

*RST Setting

0 (off)

Requirements

Test or Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"SETUP:WWQUALITY:COUNT:STATE ON"
! Turns on multi-measurements.

SETup:WWQuality:INTerval:HSDPcchannel

Function

Sets/queries HS-DPCCH Measurement Interval .

This command is only applicable when SETup:WWQuality:TRIGger:SOURce = HSDPcchannel.

The sum of HS-DPCCH Trigger Subslot Alignment (see SETup:WWQuality:TRIGger:ALIGnment:HSDPcchannel:SUBSlot ) and HS-DPCCH Measurement Interval cannot exceed 1 slot.

Setting

Range: 0.5 to 1.0 slot

Resolution: 0.1 slot

Query

Same as setting

*RST Setting

1.0 slot

Requirements

Test Application Revision: A.09 and above, with the required feature license

Lab Application Revision: C.04 and above

Lab Application Revision: D.00 and above

Programming Example

 
OUTPUT 714;"SETup:WWQuality:INTerval:HSDPcchannel 0.8"
! Sets HS-DPCCH Measurement Interval to 0.8 slot.

SETup:WWQuality:TIMeout[:STIMe]

Function

The setting form of this command performs two functions: (1) sets the waveform quality measurement's timeout value, and (2) sets the waveform quality measurement's timeout STATe to 1 (on).

The query form returns the waveform quality measurement's timeout value.

Setting

Range: 1 to 999 seconds

Resolution: 1 second

Query

Range: 1 to 999

*RST Setting

10 seconds, off

Requirements

Test or Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"SETUP:WWQUALITY:TIMEOUT:STIME 5S" 
! Sets timeout state to ON and sets the timeout time to 5 seconds.

SETup:WWQuality:TIMeout:STATe

Function

Sets/queries the waveform quality measurement's timeout state.

Setting

Range: 1|ON|0|OFF

Query

Range: 1|0

*RST Setting

0 (off)

Requirements

Test or Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"SETUP:WWQUALITY:TIMEOUT:STATE ON"

SETup:WWQuality:TIMeout:TIME

Function

Sets/queries the waveform quality measurement's timeout setting to be used when the timeout state is set to ON.

Setting

Range: 1 to 999 seconds

Resolution: 1 second

Query

Range: 1 to 999

*RST Setting

10 seconds

Requirements

Test or Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"SETUP:WWQUALITY:TIMEOUT:TIME 5S"

SETup:WWQuality:TRANsient

Function

Sets/queries Transient Period .

Setting

Range: INCLude|EXCLude

Query

Range: INCL|EXCL

*RST Setting

INCL (include)

Requirements

Test Application Revision: A.09 and above, with the required feature license

Lab Application Revision: C.04 and above

Lab Application Revision: D.00 and above

Test Application Revision A.10 and Lab Application D.01, this command is now applicable for all Trigger Source settings (non-HSDPA as well as HSDPA)

Programming Example

 
OUTPUT 714;"SETup:WWQuality:TRANsient EXCLude"
! Sets Transient Period to Exclude.

SETup:WWQuality:TRIGger:ALIGnment:HSDPcchannel:SLOT

Function

Sets/queries HS-DPCCH Trigger Slot Alignment .

This command is only applicable when SETup:WWQuality:TRIGger:SOURce = HSDPcchannel.

Setting

Range: ACKNack|CQI1|CQI2

Query

Range: ACKN|CQI1|CQI2

*RST Setting

ACKN

Requirements

Test Application Revision: A.09 and above, with the required feature license

Lab Application Revision: C.04 and above

Lab Application Revision: D.00 and above

Programming Example

 
OUTPUT 714;"SETup:WWQuality:TRIGger:ALIGnment:HSDPcchannel:SLOT CQI1"
! Sets HS-DPCCH Trigger Slot Alignment to CQI1.

SETup:WWQuality:TRIGger:ALIGnment:HSDPcchannel:SUBFrame

Function

Sets/queries HS-DPCCH Trigger Subframe Alignment .

This command is only applicable when SETup:WWQuality:TRIGger:SOURce = HSDPcchannel.

Setting

Range: 0 to 5

Resolution: 1

Query

Same as setting.

*RST Setting

0

Requirements

Test Application Revision: A.09 and above, with the required feature license

Lab Application Revision: C.04 and above

Lab Application Revision: D.00 and above

Programming Example

 
OUTPUT 714;"SETup:WWQuality:TRIGger:ALIGnment:HSDPcchannel:SUBFrame 3"
! Sets HS-DPCCH Trigger Subframe Alignment to subframe 3.

SETup:WWQuality:TRIGger:ALIGnment:HSDPcchannel:SUBSlot

Function

Sets/queries HS-DPCCH Trigger Subslot Alignment .

This command is only applicable when SETup:WWQuality:TRIGger:SOURce = HSDPcchannel.

The sum of HS-DPCCH Trigger Subslot Alignment and HS-DPCCH Measurement Interval (see SETup:WWQuality:INTerval:HSDPcchannel ) cannot exceed 1 slot.

Setting

Range: 0 to 0.5 slot

Resolution: 0.1 slot

Query

Same as setting.

*RST Setting

0.0 slot

Requirements

Test Application Revision: A.09 and above, with the required feature license

Lab Application Revision: C.04 and above

Lab Application Revision: D.00 and above

Programming Example

 
OUTPUT 714;"SETup:WWQuality:TRIGger:ALIGnment:HSDPcchannel:SUBSlot 0.3"
! Sets HS-DPCCH Trigger Subslot Alignment to 0.3 slot.

SETup:WWQuality:TRIGger:SOURce

Function

Sets/queries Trigger Source .

Setting

Range: IMMediate|PROTocol|EXTernal|AUTO|HSDPcchannel|EFRame

Query

Range: IMM|PROT|EXT|AUTO|HSDP|EFR

*RST Setting

AUTO

Requirements

Test Application Revision: A.02 and above.

Test Application Revision A.09, with the required feature license, added HSDPcchannel.

Lab Application Revision: A.01 and above.

Lab Application Revision C.04, D.00, added HSDPcchannel.

Lab Application Revision F.00, added EFRame.

Test Application Revision A.14, with the required feature license, added EFRame.

Programming Example

 
OUTPUT 714;"SETUP:WWQUALITY:TRIGGER:SOURCE AUTO"

SETup:WWQuality:TSLot

Function

Sets/queries Timeslot .

This command is only applicable when SETup:WWQuality:TRIGger:SOURce is NOT set to HSDPcchannel.

Setting

Range: 0 to 14

Resolution: 1

Query

Same as setting

*RST Setting

0

Requirements

Test or Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"SETUP:WWQUALITY:TSLOT 10"