SETup:WWQuality
Last updated: January 16, 2009
GPIB Command Conventions
SETup:WWQuality:ALIGnment:SFNumber
|
Function
|
Sets/queries which frame will be measured when the Even Frame trigger source is selected.
|
|
Setting
|
Range: ODD|EVEN
|
|
Query
|
Range: ODD|EVEN
|
|
*RST Setting
|
EVEN |
|
Requirements
|
Lab Application Revision F.00, and above.
Test Application Revision: A.14 and above, with the required feature license
|
|
Programming Example
OUTPUT 714;"SETup:WWQuality:ALIGnment:SFNumber EVEN"
|
SETup:WWQuality:CONTinuous
|
Function
|
Sets/queries the trigger arm state for the waveform quality measurement. The trigger arm state determines whether the waveform quality measurement will be made once then stop (0|OFF (single)), or automatically rearm upon completion of one measurement and repeat the process (1|ON (continuous)).
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off)
|
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:WWQUALITY:CONTINUOUS OFF"
!Sets measurement to single trigger mode.
|
SETup:WWQuality:COUNt[:SNUMber]
|
Function
|
The setting form of this command performs two functions: (1) sets the number of waveform quality measurements to be made in a multi-measurement, and (2) sets the multi-measurement STATe command to 1 (on).
The query form returns the number of waveform quality multi-measurements to be made when multi-measurement state is ON.
|
|
Setting
|
Range: 1 to 999
|
|
Query
|
Range: 1 to 999
|
|
*RST Setting
|
Off (10 when STATe = On) |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:WWQUALITY:COUNT:SNUMBER 5"
!Turns on multi-measurements and sets the number of measurements to 5.
|
SETup:WWQuality:COUNt:NUMBer
|
Function
|
Sets/queries the number of waveform quality measurements to be made when the multi-measurement state is ON.
|
|
Setting
|
Range: 1 to 999
|
|
Query
|
Range: 1 to 999
|
|
*RST Setting
|
10 |
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:WWQUALITY:COUNT:NUMBER 5"
!Sets the number of measurements to 5 when the multi-measurement state is set to ON.
|
SETup:WWQuality:COUNt:STATe
|
Function
|
Sets/queries the multi-measurement state of the waveform quality measurement.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off)
|
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:WWQUALITY:COUNT:STATE ON"
! Turns on multi-measurements.
|
SETup:WWQuality:INTerval:HSDPcchannel
|
Function
|
Sets/queries
HS-DPCCH Measurement Interval
.
This command is only applicable when
SETup:WWQuality:TRIGger:SOURce
= HSDPcchannel.
The sum of
HS-DPCCH Trigger Subslot Alignment
(see
SETup:WWQuality:TRIGger:ALIGnment:HSDPcchannel:SUBSlot
) and
HS-DPCCH Measurement Interval
cannot exceed 1 slot.
|
|
Setting
|
Range: 0.5 to 1.0 slot
Resolution: 0.1 slot
|
|
Query
|
Same as setting |
|
*RST Setting
|
1.0 slot |
|
Requirements
|
Test Application Revision: A.09 and above, with the required feature license
Lab Application Revision: C.04 and above
Lab Application Revision: D.00 and above
|
|
Programming Example
OUTPUT 714;"SETup:WWQuality:INTerval:HSDPcchannel 0.8"
! Sets HS-DPCCH Measurement Interval to 0.8 slot.
|
SETup:WWQuality:TIMeout[:STIMe]
|
Function
|
The setting form of this command performs two functions: (1) sets the waveform quality measurement's timeout value, and (2) sets the waveform quality measurement's timeout STATe to 1 (on).
The query form returns the waveform quality measurement's timeout value.
|
|
Setting
|
Range: 1 to 999 seconds
Resolution: 1 second
|
|
Query
|
Range: 1 to 999
|
|
*RST Setting
|
10 seconds, off
|
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:WWQUALITY:TIMEOUT:STIME 5S"
! Sets timeout state to ON and sets the timeout time to 5 seconds.
|
SETup:WWQuality:TIMeout:STATe
|
Function
|
Sets/queries the waveform quality measurement's timeout state.
|
|
Setting
|
Range: 1|ON|0|OFF
|
|
Query
|
Range: 1|0
|
|
*RST Setting
|
0 (off)
|
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:WWQUALITY:TIMEOUT:STATE ON"
|
SETup:WWQuality:TIMeout:TIME
|
Function
|
Sets/queries the waveform quality measurement's timeout setting to be used when the timeout state is set to ON.
|
|
Setting
|
Range: 1 to 999 seconds
Resolution: 1 second
|
|
Query
|
Range: 1 to 999
|
|
*RST Setting
|
10 seconds
|
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example
OUTPUT 714;"SETUP:WWQUALITY:TIMEOUT:TIME 5S"
|
SETup:WWQuality:TRANsient
|
Function
|
Sets/queries
Transient Period
.
|
|
Setting
|
Range: INCLude|EXCLude
|
|
Query
|
Range: INCL|EXCL
|
|
*RST Setting
|
INCL (include) |
|
Requirements
|
Test Application Revision: A.09 and above, with the required feature license
Lab Application Revision: C.04 and above
Lab Application Revision: D.00 and above
Test Application Revision A.10 and Lab Application D.01, this command is now applicable for all Trigger Source settings (non-HSDPA as well as HSDPA)
|
|
Programming Example
OUTPUT 714;"SETup:WWQuality:TRANsient EXCLude"
! Sets Transient Period to Exclude.
|
SETup:WWQuality:TRIGger:ALIGnment:HSDPcchannel:SLOT
|
Function
|
Sets/queries
HS-DPCCH Trigger Slot Alignment
.
This command is only applicable when
SETup:WWQuality:TRIGger:SOURce
= HSDPcchannel.
|
|
Setting
|
Range: ACKNack|CQI1|CQI2
|
|
Query
|
Range: ACKN|CQI1|CQI2
|
|
*RST Setting
|
ACKN |
|
Requirements
|
Test Application Revision: A.09 and above, with the required feature license
Lab Application Revision: C.04 and above
Lab Application Revision: D.00 and above
|
|
Programming Example
OUTPUT 714;"SETup:WWQuality:TRIGger:ALIGnment:HSDPcchannel:SLOT CQI1"
! Sets HS-DPCCH Trigger Slot Alignment to CQI1.
|
SETup:WWQuality:TRIGger:ALIGnment:HSDPcchannel:SUBFrame
|
Function
|
Sets/queries
HS-DPCCH Trigger Subframe Alignment
.
This command is only applicable when
SETup:WWQuality:TRIGger:SOURce
= HSDPcchannel.
|
|
Setting
|
Range: 0 to 5
Resolution: 1
|
|
Query
|
Same as setting. |
|
*RST Setting
|
0 |
|
Requirements
|
Test Application Revision: A.09 and above, with the required feature license
Lab Application Revision: C.04 and above
Lab Application Revision: D.00 and above
|
|
Programming Example
OUTPUT 714;"SETup:WWQuality:TRIGger:ALIGnment:HSDPcchannel:SUBFrame 3"
! Sets HS-DPCCH Trigger Subframe Alignment to subframe 3.
|
SETup:WWQuality:TRIGger:ALIGnment:HSDPcchannel:SUBSlot
|
Function
|
Sets/queries
HS-DPCCH Trigger Subslot Alignment
.
This command is only applicable when
SETup:WWQuality:TRIGger:SOURce
= HSDPcchannel.
The sum of
HS-DPCCH Trigger Subslot Alignment
and
HS-DPCCH Measurement Interval
(see
SETup:WWQuality:INTerval:HSDPcchannel
) cannot exceed 1 slot.
|
|
Setting
|
Range: 0 to 0.5 slot
Resolution: 0.1 slot
|
|
Query
|
Same as setting. |
|
*RST Setting
|
0.0 slot |
|
Requirements
|
Test Application Revision: A.09 and above, with the required feature license
Lab Application Revision: C.04 and above
Lab Application Revision: D.00 and above
|
|
Programming Example
OUTPUT 714;"SETup:WWQuality:TRIGger:ALIGnment:HSDPcchannel:SUBSlot 0.3"
! Sets HS-DPCCH Trigger Subslot Alignment to 0.3 slot.
|
SETup:WWQuality:TRIGger:SOURce
|
Function
|
Sets/queries
Trigger Source
.
|
|
Setting
|
Range: IMMediate|PROTocol|EXTernal|AUTO|HSDPcchannel|EFRame
|
|
Query
|
Range: IMM|PROT|EXT|AUTO|HSDP|EFR
|
|
*RST Setting
|
AUTO |
|
Requirements
|
Test Application Revision: A.02 and above.
Test Application Revision A.09, with the required feature license, added HSDPcchannel.
Lab Application Revision: A.01 and above.
Lab Application Revision C.04, D.00, added HSDPcchannel.
Lab Application Revision F.00, added EFRame.
Test Application Revision A.14, with the required feature license, added EFRame.
|
|
Programming Example
OUTPUT 714;"SETUP:WWQUALITY:TRIGGER:SOURCE AUTO"
|
SETup:WWQuality:TSLot
|
Function
|
Sets/queries
Timeslot
.
This command is only applicable when
SETup:WWQuality:TRIGger:SOURce
is
NOT
set to HSDPcchannel.
|
|
Setting
|
Range: 0 to 14
Resolution: 1
|
|
Query
|
Same as setting |
|
*RST Setting
|
0
|
|
Requirements
|
Test or Lab Application Revision: A.01 and above
|
|
Programming Example