Programming an HSDPA Block Error Ratio Measurement
Last updated: January 16, 2009
This section is only applicable to the lab application or a test application with the required feature license.
This example is for
FDD Test Operating Mode
. The measurement is also available in
Active Cell Operating Mode
.
This section provides an example of how to make HSDPA BLER measurements via remote program. The following program example assumes that the UE is connected to the RF IN/OUT connector.
The basic procedure to test HSDPA BLER is as follows:
-
Set the HSDPA BLER setup parameters as desired using the
SETup:HBLerror
commands.
-
Use the
INITiate:HBLerror
command to start the measurement.
-
Use the
FETCh:HBLerror
query to obtain the measurement results (or use the
READ:HBLerror?
command to both initiate and fetch the measurement as a sequential operation).
Programming Example
10 ! HSDPA Block Error Ratio Measurement Programming Example
20 ! 3GPP TS 34.121 6.3A Maximum Input Level for HS-PDSCH
30 ! Reception (16QAM)
40 !
50 Testset=714
60 !
70 !***Set up test parameters***
80 !
90 OUTPUT Testset;"CALL:OPERating:MODE FDDTest"
100 ! Set Operating Mode to FDD Test
110 OUTPUT Testset;"CALL:POWer -25.7"
120 ! Set Cell Power to -25.7 dB
130 OUTPUT Testset;"CALL:SERVice:RBTest:RAB HSDParmc12"
140 ! Set Channel Type to 12.2k RMC + HSDPA
150 OUTPUT Testset;"CALL:FDDTest:FRC:TYPE QAM1"
160 ! Set FRC Type to H-Set 1 16QAM
170 OUTPUT Testset;"CALL:FDDTest:MACHs:NTRans 1"
180 ! Set FDD Test Number of Tranmissions to 1
190 OUTPUT Testset;"CALL:FDDTest:MACHs:RVSequence `6'"
200 ! Set FDD Test RV Sequence to 6,0,0,0,0,0,0,0
210 OUTPUT Testset;"CALL:FDDTest:HRNTi `32'"
220 ! Set FDD Test Primary H-RNTI (Hex) as needed
230 OUTPUT Testset;"CALL:MS:POWer:TARGet 20"
240 ! Set UE Target Power to 20 or 18 dBm
250 OUTPUT Testset;"CALL:FDDTest:DPCHannel:HSDPa -13"
260 ! Set HSDPA FDD Test DPCH Level to -13 dB
270 OUTPUT Testset;"CALL:FDDTest:HSSCchannel -13"
280 ! Set FDD Test HS-SCCH 1 Level to -13 dB
290 !
300 !***Set up measurement parameters***
310 !
320 OUTPUT Testset;"SETup:HBLerror:COUNt 500"
330 ! Set Number of blocks to test to 500
340 OUTPUT Testset;"SETup:HBLerror:CONTinuous OFF"
350 ! Set Trigger Arm to Single
360 !
370 CLEAR SCREEN
380 PRINT "Configure the UE to synchronize to the test "
390 PRINT "set, demodulate the HS-SCCH and HS-PDSCH "
400 PRINT "channels and generate an HS-DPCCH."
410 PRINT
420 PRINT "Press CONTINUE"
430 PRINT
440 !
450 PAUSE
460 !
470 !***INITiate and FETCh measurements***
480 !
490 OUTPUT Testset;"INITiate:HBLerror"
500 ! Initiate an HBLER measurement
510 OUTPUT Testset;"FETCh:HBLerror?"
520 ENTER Testset;Int,Ratio,R,Ack,Nack,Sdtx,Num,Mcqi
530 !
540 !***Print measurement results***
550 !
560 PRINT "HSDPA Block Error Ratio Results:"
570 PRINT
580 PRINT "Integrity Indicator = ",Int
590 PRINT "Block Error Ratio (%) = ",Ratio
600 PRINT "Information Bit Throughput (kbps) = ",R
610 PRINT "Positive Acknowledgments = ",Ack
620 PRINT "Negative Acknowledgments = ",Nack
630 PRINT "Statistical DTXs = ",Sdtx
640 PRINT "Number of Blocks Tested = ",Num
650 PRINT "Median Channel Quality Indicator = ",Mcqi
660 !
670 END
680 !
|