E1963A W-CDMA/HSPA Test Application Revision Information
Last updated: September 2, 2009
This document describes the features in the Agilent Technologies E1963A W-CDMA Mobile Test Application releases. This document contains the original features, as well as enhancements that have been added over time.
If you are interested in comparing the key feature differences between the latest releases of each of the W-CDMA/HSPA Test and Lab Applications, see:
W-CDMA/HSPA Applications Feature Comparison
You may need to upgrade the hardware in your test set before installing the application firmware described here. If you install application firmware on a test set with incompatible hardware, the following may occur:
To determine if a hardware upgrade is required for your testing needs, please review the hardware requirement information at:
http://www.agilent.com/find/8960upgrades
Select the appropriate link below to view the required release.
A.15 Release - October 2009
For the most up-to-date information about this release, please visit www.agilent.com/find/8960manuals.
Hardware Requirements
Please be aware that this release has specific hardware requirements to be able to run correctly.
To determine if a hardware upgrade is required for this release, please review the hardware requirement information at:
http://www.agilent.com/find/8960upgrades
Measurements
-
The E1963A now includes the QPSK EVM measurement. This measurement can be used to determine the error between the transmitted signal of a UE and the desired ideal signal, like the Waveform Quality measurement. The difference is that the QPSK EVM measurement expects a QPSK modulated input signal, which is similar to the WCDMA uplink signal with only one code channel. The data carried by the QPSK symbols sequence can be any pattern. There are several results reported with this measurement. These include the following:
-
Error Vector Magnitude (EVM)
-
Peak EVM - the maximum symbol EVM which is the calculated EVM at each QPSK symbol in the measurement interval
-
Phase Error
-
Origin Offset
-
Frequency Error
See
SETup:EVMQpsk
,
INITiate
,
READ
, and
FETCh:EVMQpsk
.
_____________________________________________________________________________________________________
A.14.18 Release - May 2009
For the most up-to-date information about this release, please visit www.agilent.com/find/8960manuals.
Hardware Requirements
Please be aware that this release has specific hardware requirements to be able to run correctly.
To determine if a hardware upgrade is required for this release, please review the hardware requirement information at:
http://www.agilent.com/find/8960upgrades
Call Processing
-
The E1963A includes HSPA+ 64QAM DL test modes with signaling, HSPA+ MAC_ehs and Layer 2 enhancements. Layer 2 enhancements involve dynamically controlling the RLC PDU and SDU sizes instead of them being fixed. H-Set 8 is the one FRC that is now defined with 64QAM specifically for testing HSPA+ devices.
An additional feature license is required to enable this functionality in a licensed test application.
Refer to the following items:
-
Changes on the HS-SCCH coding scheme to accommodate 64QAM: To be able to support signaling of three modulation formats (QPSK, 16QAM and 64QAM), the coding of HS-SCCHs changes if the UE is configured to be able to use 64QAM modulation type by higher layer signaling and the modulation format on the HS-PDSCHs is 16QAM or 64QAM.
-
New HS-DSCH Transport Block table defined for 64QAM: To support the 64QAM modulation format, a new table of HS-DSCH Transport Block Size and a corresponding table of K0,I of different numbers of channelization codes and modulation schemes are defined in 25.321 v7.8.0. To differentiate the additional K0,I table in release 7 from the existing K0,I table defined in release 5, the former is named octet aligned table, the latter is named bit aligned table. The selection between the two tables in UE depends on 3 Information Elements transmitted from the network which are defined in 25.331 v7.8.0:
-
DL MAC header type
-
Downlink 64QAM configured
-
HS-DSCH TB size table
-
H-SET 8 (64QAM modulation): Each 3GPP FRC H-Set defines a static configuration at the transport channel and physical channel level (for example, block size, number of HS-PDSCHs, inter-TTI distance, number of HARQ processes). The end result is a fixed data rate for the purposes of easier more consistent testing. Each FRC H-Set is associated with a particular UE category. FRC H-Sets 1, 2, 3, 6 and 10 have both QPSK and 16QAM variants, H-Set 4 and 5 only have QPSK variants. This is because UE categories 11 and 12, which are associated with H-Set 4 and 5 respectively, are only capable of QPSK modulation. H-Set 8 only has 64QAM variants. The FRC does not define the MAC-hs and MAC-ehs parameters such as the number of transmissions of a block and the RV sequence, so you must still manually configure these items. H-Set 8 implies that MAC-ehs be applied instead of MAC-hs, octet-aligned HS-DSCH Transport Block Size table be applied. H-Set 8 does not specify the MAC-d PDU size. However, you still need to specify the MAC-ehs SDU size. This can be done using the MAC-d PDU size.
New RB test mode parameters to support testing UE categories greater than 12.
-
MAC-ehs: The use of an octet-aligned table requires MAC-ehs (see
CALL:FDDTest:HSDSchannel:UDEFined:MACEHS:TBSTable:ALIGnment
). MAC-ehs is introduced to support the 64QAM modulation type and MIMO to achieve higher data rate at the MAC layer.
-
HSDPA 14.4Mbps RB Test and FDD Test modes and arbitrary configuration of downlink code allocation: Downlink throughput with HSDPA test modes in increased to a maximum of 14.4Mbps (Category 10).
An additional feature license is required to enable this functionality in a licensed test application.
Also the ability is provided to flexibly configure channel codes to set up to 15 HS-PDSCHs needed for maximum HSDPA throughput. H-Set 10 allows up to 15 HS-DSCH code channels.
-
Arbitrary DL code configuration (collision detection): You can freely set channelization codes in the allowable integer ranges, and the test set will apply a code collision detection procedure on all active channels and report a warning when a collision is detected.
-
Support for Band XII channels (UL/DL); Band XIII channels (UL/DL); Band XIV channels (UL/DL). See
CALL:CHANnel
,
CALL:UPLink:CHANnel[:MCHannel]
,
CALL:SETup
,
CALL:STATus:FBINdicator?
,
CALL:STATus:SETup:RBReconfig:FBINdicator?
,
CALL:STATus:SETup:TCReconfig:FBINdicator?
, and
CALL:STATus:SETup[:PCReconfig]:FBINdicator?
.
An additional current Revision to Current (R2C) license is required to enable this functionality in a licensed test application.
-
3GPP TS 34.121 related enhancements:
-
Independent H-RNTI: The UE identity values sent on the four HS-SCCHs (H-RNTIs) are extended so that all four can be set independently. This provides support for 3GPP TS 34.121 s9.4.1. In this release, you can configure the state of any HS-SCCH to be off, i.e. neither allocating the HS-SCCH in the test set nor configuring the UE to allocate that HS-SCCH through RRC messages when a HSDPA or HSPA connection is established (see
CALL:FDDTest:HSSCchannel[1]:CONFig:STATe
).
-
Existing preset call configurations have been expanded to add configurability for the HSDPA and HSUPA sub-tests defined in the 3GPP TS 34.121 Annex C tables. This has added 26 new preset call configurations. Previously there were (5) HSDPA and (2) HSPA preset call configuration settings. These are retained as the "generic" setups but additional sub-set setups are added.
-
Support for two new data types (PRBS20 and PRBS23) is provided for use with W-CDMA or HSDPA channels. This adds compliance for 3GPP TS 34.121 s9.2.1A, C, D, E, F, and G. Sections 9.2.1H and I are also supported when 64QAM is the selected modulation type (see )
CALL:FDDTest:HSDSchannel:DATA
,
CALL:DTCHannel:DATA
, and
CALL:HSDPa:SERVice:RBTest:HSDSchannel:DATA
).
-
The ranges of the relative levels for the E-HICH, E-AGCH, and ERGCH are extended to support 3GPP TS 34.121 sections 10.2.1.1, 10.3.1.1, 10.3.1.2, and 10.4.1.
-
The AG Pattern has been extended to 8 values, adding support for 34.121 section 10.4.1 test.When the Absolute Grant mode parameter is set to "Pattern" then the application will transmit a continuous sequence of values to the UE over the E-AGCH (see
CALL:HSUPa
).
-
A new parameter has been added to set the activation time of WCDMA to GSM handovers. See
CALL:HANDoff:SYSTem:GSM:ATIMe
.
-
SMS TP-OA, TP-RA, RP-OA extension - allows you to configure parameters TP-OA, TP-RA, RP-OA.
An additional current Revision to Current (R2C) license is required to enable this functionality in a licensed test application.
Measurements
-
HSUPA IQ tuning, phase discontinuity measurement, waveform quality. EVM measurements are enhanced to support use with HSUPA.
An additional current Revision to Current (R2C) license is required to enable this functionality in a licensed test application.
-
SEM enhancement: This 34.121 measurement has been modified for certain frequency bands that have small frequency separation. Also, an absolute measurement result has been added to the standard and this has been incorporated. See
SETup:WSEMask
and
FETCh:WSEMask
.
An additional current Revision to Current (R2C) license is required to enable this functionality in a licensed test application.
-
An in-channel power result has been added to the Adjacent Channel Leakage Ratio (ACLR) measurement.
An additional current Revision to Current (R2C) license is required to enable this functionality in a licensed test application.
See
FETCh:WACLeakage
.
-
The Inner Loop Power measurement now supports use with the 12.2k RMC + HSDPA channel type.
An additional current Revision to Current (R2C) license is required to enable this functionality in a licensed test application.
-
The frequency range of the Fast Device Tune measurement has been extended.
_____________________________________________________________________________________________________
A.13.13 Release - September 2008
For the most up-to-date information about this release, please visit www.agilent.com/find/8960manuals.
Hardware Requirements
Please be aware that this release has specific hardware requirements to be able to run correctly.
To determine if a hardware upgrade is required for this release, please review the hardware requirement information at:
http://www.agilent.com/find/8960upgrades
Call Processing
-
5.74 Mbps HSUPA (2ms TTI) in RB test mode and FDD test mode - The test set now supports 5.74 Mbps HSUPA (2ms TTI) in addition to the previously supported 2 Mbps HSUPA (10ms TTI), allowing full support of the E-DCH Category 6 HSUPA device verification and manufacturing.
An additional feature license is required to enable this functionality in a licensed test application.
-
One-box video loopback - Allows a video call using just one test set and one UE by looping the voice and video data sent by the UE back to the UE.
An additional feature license is required to enable this functionality in a licensed test application.
-
AMR/WB-AMR real-time vocoder and digital audio interface - This release includes an AMR/WB-AMR vocoder, which is supported in both voice loopback and with the digital audio interface (playing and recording of pre-defined audio files). This allows for the audio codec verification and real-time end-to-end audio testing.
An additional feature license is required to enable this functionality in a licensed test application.
See
CALL:SERVice:AMR:RAB
.
-
Short message service (SMS) - Allows you to test both the cell broadcast and point-to-point (mobile terminated and mobile originated messages) SMS capability of your UE (previously SMS was only supported in the lab application).
An additional feature license is required to enable this functionality in a licensed test application.
See
Short Message Service (SMS)
.
-
FM source - The test set, with an external adapter (E5520A) connecting to the RF IN/OUT port, can generate FM mono signals from 10-110 MHz, allowing for calibration of FM receiver of your UE. See
FM Broadcast
.
-
Equipment Identity Request can now be configured to request from the UE either the IMEI, IMEISV, or both. See
CALL:EIDentity
,
CALL:MS:REPorted:EISV?
and
CALL:MS:REPorted:EISV:SVN?
.
-
Support for Band XI. See
CALL:STATus:FBINdicator?
,
CALL:STATus:SETup:RBReconfig:FBINdicator?
,
CALL:STATus:SETup:TCReconfig:FBINdicator?
, and
CALL:STATus:SETup[:PCReconfig]:FBINdicator?
.
-
The UTRA FDD Speech Echo Loopback Delay value was previously fixed at 0.5 seconds. This setting determines the amount of time that speech frames received on the uplink are delayed before being retransmitted on the downlink. A new parameter has been added with a default value of 0.5 seconds to maintain backwards compatibility. See
CALL:SERVice:AMR:SPEech:ECHO:LOOPback:DELay
.
-
E-TFCI recording has been enhanced allowing you to control whether all E-DPDCH subframes are recorded, or only those that pass CRC checks.
An additional feature license is required to enable this functionality in a licensed test application.
See
CALL:HSUPa:ETFCi:RECord:BEHavior
.
Measurements
-
Enhanced fast device tune (FDT) - Supports 10ms measurement step size in addition to the 20ms step size previously available in the E1999A-201 feature option (see
SETup:CFDTune:POWer:STEP:LENGth
).
An additional feature license is required to enable this functionality in a licensed test application.
-
Enhancements to the UE reported measurements - Previously, the CPICH Ec/No and CPICH RSCP UE reported values were displayed in the index value. With this release you can get more intuitive values in dB or dBm.
Other Features
-
The test set now provides summary information for the user calibrations that have been performed, along with a readout of the test set's current operating temperature. See
User Calibration Summary
.
_____________________________________________________________________________________________________
A.12.11 Release - November 2007
Call Processing
-
Support for HSUPA in RB Test Mode and FDD Test Mode. The test set supports 10 ms TTI HSUPA in conjunction with HSDPA (HSUPA + HSDPA = HSPA). See
HSPA in Active Cell Operating Mode
,
HSPA Radio Bearer Test Mode
and
HSPA in FDD Test Operating Mode
.
An additional feature license is required to enable this functionality in a licensed test application.
-
New
E-DCH Cell Indicator
and
HSDPA Cell Indicator
settings allow UEs to display a visual cue that HSUPA or HSDPA functionality is available in the current cell.
An additional feature license is required to enable this functionality in a licensed test application.
-
New
HSPA 34.121 Preset Call Configurations
(
5.2B, 5.9B, 5.10B, 5.13.2B with QPSK
and
5.2D with QPSK
) simplify configuring the test set for 3GPP TS 34.121 HSPA tests from the front panel.
An additional feature license is required to enable this functionality in a licensed test application.
-
DeltaACK
,
DeltaNACK
and
DeltaCQI
are now applicable to FDD test mode (previously these settings were only used by the test set while in active cell operating mode). This allows you to indicate the DeltaACK, DeltaNACK and DeltaCQI values being used by the UE while in
FDD Test Operating Mode
, for use by the code domain measurement.
An additional feature license is required to enable this functionality in a licensed test application.
Known Issues
-
The Block Error Ratio (BLER) measurement does not operate correctly when the Channel Type is set to 12.2k RMC + HSPA. The measurement always reports an error ratio of 100% with this channel type. With 12.2k RMC + HSPA, the BLER measurement uses RLC Transparent Mode (TM) and would require the UE Loopback Type to be set to Type 2 in order to loop back data and CRC bits. However, UE Loopback Type is fixed to Type 1 for this configuration, as required by TS 34.109 (refer to section 5.3.1 in TS 34.109, rev 7.2.0). This means that the BLER measurement cannot work correctly. In a subsequent release of the E1963A, the BLER measurement will not be supported for the 12.2k RMC + HSPA Channel Type.
_____________________________________________________________________________________________________
A.11.08 Release - July 2007
A downloadable version of the Online User's Guide (CHM Help File) that is specific to this release is available at:
http://www.home.agilent.com/upload/cmc_upload/All/E1963_A11_E6703_D02_T03_Ref_Guide.chm
NOTE: To properly view the CHM Help File, you must save it to your desktop. For Windows XP, you must also then right-click on the file and select Properties>>Unblock.
Call Processing
-
Support for Band X (see
Channel (UARFCN) Parameters
).
-
The range of the
Transmit SIB5bis
setting has been expanded to include
Band X
(
BAND10
) and
Standard Bands
(
SBANds
). The default has changed from
Bands IV & IX
to
Standard Bands
(and the default value for the
CALL[:CELL]:BCCHannel:SIB5:BIS
command has changed from
BAND49
to
SBANds
).
-
If your test set includes the required hardware (see
Hardware Requirements
) uplink Betac can now be set to 1 via the following settings:
-
AWGN Power
and
External AWGN Power
can now be 10 dB above or 20 dB below
Cell Power
or
Cell 2 Power
, and can be within 20 dB of each other (previously the limit was +/- 10 dB).
-
Changes have been made to accommodate 3GPP TS 25.331 v5.17.0 s8.6.6.28, which now specifies that the UE's behavior is undefined if the network sets the Timing Indication information element to Initialise on a non-hard handover (i.e. where the UARFCNs and one or more Primary Scrambling Codes remain unchanged as part of the reconfiguration).
Transmitter Measurements
_____________________________________________________________________________________________________
A.10.19 Release - April 2007
This is a maintenance release to resolve known issues. The features offered in this release are identical to those offered in the
A.10.17 Release - March 2007
.
A.10.17 Release - March 2007
A downloadable version of the Online User's Guide (CHM Help File) that is specific to this release is available at:
http://www.home.agilent.com/upload/cmc_upload/All/E1963_A10_E6703_D01_T01_Ref_Guide.chm
NOTE: To properly view the CHM Help File, you must save it to your desktop. For Windows XP, you must also then right-click on the file and select Properties>>Unblock.
Receiver Measurements
-
*RST setting for
Trigger Arm
changed to 0 (single) for
Loopback BER
,
Block Error Ratio
and
HSDPA Block Error Ratio
measurements. See
SETup:WBERror:CONTinuous
,
SETup:WBLerror:CONTinuous
and
SETup:HBLerror:CONTinuous
. Behavior of full preset from the front panel is unchanged (a front panel full preset still sets
Trigger Arm
to
Continuous
for these three measurements).
Other Features
-
The downlink HARQ0 trigger is transmitted every time data is transmitted by HARQ process 0 (which is every 12 ms when on an FRC). See
Trigger Output Setup
.
_____________________________________________________________________________________________________
A.10.12 Release - December 2006
Release has been delayed.
_____________________________________________________________________________________________________
A.09.06 Release - July 2006
A downloadable version of the Online User's Guide (CHM Help File) that is specific to this release is available at:
http://www.home.agilent.com/upload/cmc_upload/All/E1963A_A09_E6703C_C04_D00_T00.chm
NOTE: To properly view the CHM Help File, you must save it to your desktop. For Windows XP, you must also then right-click on the file and select Properties>>Unblock.
Call Processing
The settable ranges for
CALL:CHANnel
and
CALL:UPLink:CHANnel
have changed due to changes in 3GPP TS 25.101. Some channels are no longer available. See the Requirements information at
CALL:CHANnel
and
CALL:UPLink:CHANnel:CHANnel
for more information.
-
New
Current UE HS-DSCH Category
.
-
New
UE Category Parameters
.
-
Support for 3GPP TS 25.101 v7.2.0 channel changes: addition of Band VIII and Band IX, renumbering of Band III and Band IV.
-
New
DL Channel
and
Uplink Channel
ranges.
The settable ranges for
CALL:CHANnel
and
CALL:UPLink:CHANnel
have changed due to changes in 3GPP TS 25.101. Some channels are no longer available. See the Requirements information at
CALL:CHANnel
and
CALL:UPLink:CHANnel:CHANnel
for more information.
-
New
Band Arbitrator
setting (replaces
Uplink Separation (Band)
setting).
-
New
Handover Band Arbitrator
setting (replaces
Handoff Uplink Separation (Band)
setting)
-
New
34.121 Preset Call Configurations
make it much simpler to configure the test set for 3GPP TS 34.121 HSDPA tests from the front panel.
-
New user defined downlink channel for HSDPA RB Test Mode (see
User Defined Configuration of the HS-DSCH
) and HSDPA FDD Test Mode (see
HS-DSCH Parameters
).
-
New
FRC MAC-d PDU Size
setting.
-
New
Radio Bearer Reconfiguration
allows handovers from a CS Domain HSDPA RB Test Mode connection to a (non-HSDPA) symmetrical RMC.
-
Physical Channel Reconfiguration
now supported on HSDPA RB Test Mode connections.
-
System Handover
now supported on CS domain HSDPA RB Test Mode connections.
-
Transport Channel Reconfiguration enhanced to include the following new parameters:
TCR DPCH Bc/Bd Control
,
TCR Manual Uplink DPCH Bc
,
TCR Manual Uplink DPCH Bd
,
TCR Default DPCH Offset (DOFF)
and
TCR Relative DPCH Frame Offset
.
-
Transport Channel Reconfiguration is now supported on an HSDPA RB Test Mode connection. New parameters added for HSDPA Transport Channel Reconfiguration:
TCR DeltaACK
,
TCR DeltaNACK
,
TCR DeltaCQI
,
TCR Ack-Nack Repetition Factor
,
TCR CQI Feedback Cycle (k)
,
TCR CQI Repetition Factor
,
TCR Number of HARQ Processes
,
TCR UE IR Buffer Allocation
and
TCR Explicit UE IR Buffer Size
.
-
New
Current DPCH Offset
.
-
New
DPCH Frame Offset
setting (FDD test operating mode only).
This setting replaces the use of
Default DPCH Offset (DOFF)
in
FDD Test
operating mode (previously, you could use the
Default DPCH Offset (DOFF)
setting to control the DPCH Frame Offset in
FDD Test
mode;
Default DPCH Offset (DOFF)
is now only available in active cell operating mode).
-
New
Network Mode of Operation
setting. Previously Network Mode of Operation was signalled by the test set with a fixed value of 2. You may now set the value of this Information Element to either 1 or 2. Note, the default setting for
Network Mode of Operation
is 1, which is different from the fixed value previously sent by the test set.
-
New
Paging Parameters
menu replaces
Paging IMSI
on front panel
Call Control 1 of 4
(
F4
). The
Paging Parameters
menu includes
Paging IMSI
and the following settings which were moved from the
Cell Parameters
menu:
CS Paging Identity Type
,
TMSI Assignment
,
TMSI
and
Repeat Paging
.
Transmitter Measurements
-
New Fast Device Tune measurement (see
Fast Device Tune Measurement Description
). An additional feature license is required to enable this functionality in a licensed test application. This feature does not require a feature license in the lab application. See www.agilent.com/find/8960upgrades for more information.
-
Waveform quality, code domain and IQ tuning measurements now support HSDPA (see
Waveform Quality Measurement Description
,
Code Domain Measurement Description
and
IQ Tuning Measurement Description
). When
Trigger Source
is set to
HS-DPCCH
, many new settings and results are available.
-
Trigger Source
range now includes
HS-DPCCH
.
-
New
Transient Period
setting.
-
New
HS-DPCCH Trigger Subframe Alignment
setting.
-
New
HS-DPCCH Trigger Slot Alignment
setting.
-
New
HS-DPCCH Trigger Subslot Alignment
setting.
-
New
HS-DPCCH Measurement Interval
setting.
-
New Beta
hs-acknack
and Beta
hs-cqi
results.
-
Phase discontinuity measurement enhancements (see
Phase Discontinuity Measurement Description
).
-
New 18 up and 18 down settings for
Power Control Pattern
.
-
New peak EVM results (via remote access only). Previously only rms EVM results were available.
Other Features
-
Previously, the downlink HARQ0 trigger occurred every time data was transmitted by HARQ process 0 (which is every 12 ms when on an FRC). The downlink HARQ0 trigger is now only transmitted when the HARQ0 process is aligned with the 10 ms system frame clock (which is every 60 ms when on an FRC). See
Trigger Output Setup
.
-
New
Thermal Power Null Adjustment
.
_____________________________________________________________________________________________________
A.08.31 Release - January 2006
A downloadable version of the Online User's Guide (CHM Help File) that is specific to this release is available at:
http://www.home.agilent.com/upload/cmc_upload/All/E1963A_A0820_E6703C_C03_Ref_Guide.chm
NOTE: To properly view the CHM Help File, you must save it to your desktop. For Windows XP, you must also then right-click on the file and select Properties>>Unblock.
Call Processing
The settable ranges for
CALL:CHANnel
and
CALL:UPLink:CHANnel
have changed. Some channels are no longer available. See the Requirements information at
CALL:CHANnel
and
CALL:UPLink:CHANnel:CHANnel
for more information.
-
Support for
HSDPA in Active Cell Operating Mode
(HSDPA
RB Test Mode
). (An additional feature license is required to enable this functionality in a licensed test application. See www.agilent.com/find/8960upgrades for more information.)
-
GMM State
is now available in the test application (previously it was only available in the lab application).
-
New
Default DPCH Offset (DOFF)
parameter.
-
New AMR RABs: 4.75k, 5.15k, 5.9k, 6.7k, 7.4k, 7.95k, and 10.2k (see
AMR Setup
).
-
New
PCR Activation Time
parameter.
-
New
RB Test Mode PCR Loopback Messaging State
parameter.
-
New
Asymmetric RMC Loopback Messaging
parameter.
-
New
Wait for RLC Ack of Handover From UTRAN
parameter.
-
The underlying architecture of the
External Device Connection
feature (used to establish a
Video Call
) has changed at this release. This implementation is not compatible with prior revisions of the
External Device Connection
. To establish an
External Device Connection
between two test sets, the test sets must have compatible firmware (see www.agilent.com/find/8960upgrades for more information). Note, an additional feature license is required to enable this functionality in a licensed test application.
-
Changed the formula used for calculating
Initial DPCCH TX Power
.
Transmitter Measurements
-
Dynamic Power Analysis: Dynamic range has been expanded to 35 dB (40 dB when
RRC Filter
=
On
).
Receiver Measurements
-
Loopback BER:
Confidence Level
(1-F) is now fixed to 99.8% and
Bad DUT Factor
(M) is fixed to 1.5. These parameters are being fixed because 3GPP TS 34.121 Table F.6.1.8 specifies an F of 0.2% and Bad DUT Factor of 1.5 for all Receiver and Performance Characteristics tests in 34.121 sections 6 and 7 (except for the fail limit for 6.5, Blocking Characteristics). Also, the 34.121 early pass/early fail formulas are based on the parameter D, which is mapped to F in 3GPP TS 34.901 Table 6-1 for only a small set of values of F and M (including F=0.2% and M=1.5).
_____________________________________________________________________________________________________
A.08.09 Release - August 2005
A downloadable version of the Online User's Guide (CHM Help File) that is specific to this release is available at:
http://www.home.agilent.com/upload/cmc_upload/All/E1963A_A08_E6703C_C02_Ref_Guide.chm
NOTE: To properly view the CHM Help File, you must save it to your desktop. For Windows XP, you must also then right-click on the file and select Properties>>Unblock.
Call Processing
-
Support for HSDPA in FDD test operating mode (see
HSDPA in FDD Test Operating Mode
). (An additional feature license is required to enable this functionality in a licensed test application. See www.agilent.com/find/8960upgrades for more information.)
-
Support for Bands IV and V:
-
New
DL Channel
and
Uplink Channel
ranges.
Transmitter Measurements
-
Inner loop power measurement enhancements:
-
Dynamic power analysis measurement enhancements:
-
Channel power measurement enhancements:
-
Adjacent channel leakage ratio measurement enhancements:
-
Spectrum emission mask measurement enhancements:
Receiver Measurements
-
New
HSDPA Block Error Ratio
measurement - see
HSDPA Block Error Ratio Measurement Description
. (An additional feature license is required to enable this functionality in a licensed test application. See www.agilent.com/find/8960upgrades for more information.)
Other Features
-
Downlink subframe 0 (HARQ 0) trigger available at rear panel (see
Trigger Output Setup
). (An additional feature license is required to enable this functionality in a licensed test application. See www.agilent.com/find/8960upgrades for more information.)
_____________________________________________________________________________________________________
A.07.25 Release - May 2005
A downloadable version of the Online User's Guide (CHM Help File) that is specific to this release is available at:
http://www.home.agilent.com/upload/cmc_upload/All/E1963A_A07_E6703C_C02_Ref_Guide.chm
NOTE: To properly view the CHM Help File, you must save it to your desktop. For Windows XP, you must also then right-click on the file and select Properties>>Unblock.
Other Features
_____________________________________________________________________________________________________
A.06.17 Release - January 2005
A downloadable version of the Online User's Guide (CHM Help File) that is specific to this release is available at:
http://www.home.agilent.com/upload/cmc_upload/All/E1963A_A06_E6703C_C01_Ref_Guide.chm
NOTE: To properly view the CHM Help File, you must save it to your desktop. For Windows XP, you must also then right-click on the file and select Properties>>Unblock.
Other Features
_____________________________________________________________________________________________________
A.05.33 Release - July 2004
Resolved Known Issues
-
Assert if partial preset is initiated while call status is
Releasing
.
-
Assert if UE initiates a release while the call status is
Setup
during a UE-initiated AMR voice call.
-
Test set-originated AMR voice call is dropped by UE if user does not answer the alert quickly enough.
-
Incorrect downlink CRC and DTCH block size configuration when
Uplink DTCH RMC CRC Presence
is set to
Used for Data
.
-
Test set does not send Open UE Test Loop message during release of RB test mode call.
-
Hard handover fails due to missing IE (related to Timing Indication) in Phys Chan Reconfig message.
-
AMR voice call origination fails due to incorrect extraction of security algorithm capability parameters.
_____________________________________________________________________________________________________
A.04.10 Release - July 2003
A downloadable version of the Online User's Guide (CHM Help File) that is specific to this release is available at:
http://www.home.agilent.com/upload/cmc_upload/All/E1963A_A04_E6703A_A02_Ref_Guide.chm
NOTE: To properly view the CHM Help File, you must save it to your desktop. For Windows XP, you must also then right-click on the file and select Properties>>Unblock.
Transmitter Measurements
-
Loopback BER enhancements:
-
PRACH Transmit On/Off Power enhancements:
Other Features
_____________________________________________________________________________________________________
A.03.20 Release - February 2003
The reference guide for this release is available at the following web location. Note, this is a 12.9 MB .pdf file.
http://cp.literature.agilent.com/litweb/pdf/1000-1864.pdf
This firmware release provides you with improved call processing from the previous release, three new measurements (Inner Loop Power, PRACH Transmit On/Off Power, and IQ Tuning), and enhancements to the Spectrum Emission Mask and Occupied Bandwidth measurements. The newly added Spectrum Monitor instrument provides additional transmitter measurement functionality. Also, save/recall function is available in this release. By working with the E1968A test application, this revision allows to make an inter-system handoff from W-CDMA to GSM.
Other Features
_____________________________________________________________________________________________________
A.02.35 Release - August 2002
This firmware release provides you with improved call processing from the previous release.
Measurements
-
Timing error is now returned in chips instead of seconds for the Waveform Quality and Code Domain measurements.
_____________________________________________________________________________________________________
A.02.20 Release - May 2002
The reference guide for this release is available at the following web location. Note, this is an 8.8 MB .pdf file.
http://cp.literature.agilent.com/litweb/pdf/1000-1844.pdf
This firmware release provides you with call processing, including base station originate, base station release, and closed loop power control, an additional reference measurement channel, 64k RMC, three new measurements, Spectrum Emission Mask, Occupied Bandwidth, and Code Domain Power, and enhancements to the Waveform Quality and Channel Power measurements. Also, a GPIB help mode exists in this firmware. This revision works with the E1985A fast switching test application.
Call Processing
-
Network initiated origination
This allows you to originate a call from the test set. See
CALL:ORIGinate
.
-
Network initiated release.
This allows you to end a call from the test set. See
CALL:END
.
-
Closed loop power control
For more information, refer to
Uplink Closed Loop Power Control Parameters and UE Target Power
.
-
Support for a 64k Reference Measurement Channel (RMC) has been added in this release. Refer to
CALL:DPCHannel:TYPe
for more information.
-
Hard handoff capability is available in this release. Only handoffs to new downlink and uplink channels are supported. It is not possible to switch between the 12.2k and 64k RMC while on a call. A new command has been added to initiate the handoff. (See
CALL:HANDoff
.)
-
UE reported information
This command allows you to query the test set for information the UE has sent about its identification, power class, etc. For more information, refer to
CALL:MS:REPorted
.
-
Cell parameters that can be configured include the following:
-
New downlink signal parameters that can be configured:
-
Uplink signal parameters that can be configured:
Other
-
Help Mode
This release enables the
HELP
key on the test set's front panel. When in help mode, the test set provides GPIB syntax assistance. For more information, refer to
Help Mode
.
-
This release gives you the first revision of the W-CDMA Test Application that can be used with the E1985A GSM_136/AMPS_GPRS fast switching test application. This release when used with the E1985A GSM_AMPS/136_GPRS_WCDMA fast switching test application allows you to switch quickly between GSM, AMPS/136, GPRS, and W-CDMA formats.
When writing program code for use with the E1985A, there are several parameters which require the format identifier, :WCDMA, to be appended. For details on these commands, refer to the user documentation for the GSM_AMPS/136_GPRS_WCDMA fast switching test application.
-
Measurements have to be recalibrated when you switch to the E1963A W-CDMA Test Application from the E1962B CDMA2000 Test Application of release revisions B.05 or lower.
_____________________________________________________________________________________________________
A.01.08 Release - November 2001 (Initial Test Application Release)
The reference guide for this release is available at the following web location. Note, this is a 6.5 MB .pdf file.
http://cp.literature.agilent.com/litweb/pdf/1000-1802.pdf
Call Processing
This release of the W-CDMA test application does not provide call processing. Therefore, call processing operations, such as base station origination (paging) and registration, are not available to establish a connection between the test set and the user equipment (UE).
A frequency division duplex (FDD) test mode is available to provide a downlink signal that a properly configured UE can synchronize to in order to transmit a corresponding uplink signal. The test set can then demodulate the uplink signal and make waveform quality and loopback bit error ratio measurements. See
FDD Test Operating Mode
for a description of this feature.
Transmitter Measurements
-
Thermal Power. This is an unfiltered, broad-banded power measurement that uses a thermal detector to measure the total power of all signals present at the test set's RF IN/OUT connector down to -10 dBm. Because of its high accuracy, this is the preferred power measurement for the
Maximum Output Power
test (3GPP TS 34.121, section 5.2, v3.2.0) to verify that the UE is transmitting at the correct level when transmitting at its highest output level. See
Thermal Power Measurement Description
.
-
Channel Power. This is a filtered power measurement that can be used to measure high level and low level signals within a 3.84 MHz bandwidth. This measurement is used in the
Transmit Off Power
test (3GPP TS 34.121, section 5.5.1, v3.2.0). It can also be used for calibrating mobile TX power. These tests require specific power levels to be measured within the 3.84 MHz channel bandwidth. See
Channel Power Measurement Description
.
-
Adjacent Channel Leakage Ratio. Power is measured within a 3.84 MHz bandwidth at +/-5 MHz and +/-10 MHz offsets from the center frequency. The measurement results can be displayed in either numeric and graphical formats. This measurement is defined in 3GPP TS 34.121, section 5.10, v3.2.0,
Adjacent Channel Leakage Power Ratio (ACLR)
, which verifies that the mobile station is not transmitting too much power outside of its 3.84 MHz channel bandwidth, which could interfere with other frequency channels. See
Adjacent Channel Leakage Ratio (ACLR) Measurement Description
.
-
Waveform Quality. This measurement returns the composite error vector magnitude (EVM), frequency error, origin offset, phase error, and magnitude error of the received signal. This measurement is used for the
Error Vector Magnitude (EVM)
test in 3GPP TS 34.121, section 5.13.1, and for the
Frequency Error
test in 3GPP TS 34.121, section 5.3, v3.2.0. These measurements verify the accuracy of the transmitter's modulation circuitry and RF source. For this FDD test mode release, this measurement can only be performed on a 12.2 kbps reference measurement channel (RMC) that is synchronized to the downlink signal from the test set. See
Waveform Quality Measurement Description
.
Receiver Measurements
-
Loopback bit error ratio (BER). This measurement uses the UE in loopback mode 1 to test the sensitivity of its receiver. The receiver sensitivity test is described in 3GPP TS 34.121, section 6.2,
v3.2.0, Reference Sensitivity Level
. When using the test set's FDD Test operating mode, the user must configure the UE in the loopback mode 1 to perform this measurement; no provision is made to send messages over the downlink signal to the UE to configure it. See
Loopback Bit Error Ratio (BER) Measurement Description
.
Other Features
Base Station Emulation in FDD Test Operating Mode
Base station emulation for this release is limited to sending a configurable downlink signal that the UE can synchronize to in order to transmit a corresponding uplink signal. The downlink does not send any commands to the UE to configure it for testing. All control of the UE must be provided by the user.
Downlink signal parameters that can be configured include the following settings:
-
Downlink channel codes:
-
Primary Scrambling Code
-
PICH Channelization Code
-
DPCH 12.2 RMC Channelization Code
-
Downlink channel levels:
-
FDD Test CPICH Level
-
FDD Test P-CCPCH/SCH Level
-
FDD Test PICH Level
-
FDD Test DPCH Level
-
Orthogonal Channel Noise Simulator - OCNS is automatically turned on and off, and the level set, as the downlink channel levels are changed.
-
Additive White Gaussian Noise (AWGN)
-
Downlink Transport Format Combination Indicator (TFCI)
-
Downlink channel
-
Downlink DTCH data type
-
Downlink PICH data pattern
Power control bit patterns can also be configured on the downlink. This allows you to vary the value being sent for the uplink closed loop power control data, and to send step up and step down power control sequences.
CW Operating Mode
CW operating mode provides an unmodulated RF generator signal with an adjustable level from -10 dBm to -127 dBm.
|
|