Last updated: November 11, 2010
This section is only applicable to the lab application.
You may configure the test set to ignore or reject an Activate PDP Context Request from the UE. You can choose what value is sent in the SM Cause information element of the Activate PDP Context Reject message using the Activate PDP Context Reject SM Cause setting. Use this function in parallel with Protocol Logging to verify that the UE behaves in a manner conforming to the standards for this situation and for each associated SM Cause value.
When
Activate PDP Context Reject State
is
On
, you may specify what value is sent in the SM Cause information element using the
Activate PDP Context Reject SM Cause
setting. From the front panel, you may choose from the valid causes specified in 3GPP TS 24.008 10.5.6.6.
If you select
Custom Value
from the front panel, a value of 0 is sent to the UE.
The
CALL:SERVice:GPRS:REJect:CAUSe
command allows you to send any value between 0 and 255 to the UE, even those not mapped to a cause in the standard. If you send a value other than those listed in the above table via the GPIB command, the front panel setting displays
CUSTOM
.
Ladder Diagram: UE Initiated GPRS Service, Activate PDP Context Reject