Activate PDP Context Reject

Last updated: January 16, 2009

This section is only applicable to the lab application.

You may configure the test set to simulate a network rejection of an Activate PDP Context Request from the UE by setting Activate PDP Context Reject State to On . You can choose what value is sent in the SM Cause information element of the Activate PDP Context Reject message using the Activate PDP Context Reject SM Cause setting. Use this function in parallel with Protocol Logging to verify that the UE behaves in a manner conforming to the standards for this situation and for each associated SM Cause value.

Activate PDP Context Reject SM Cause

When Activate PDP Context Reject State is On , you may specify what value is sent in the SM Cause information element using the Activate PDP Context Reject SM Cause setting. From the front panel, you may choose from the valid causes specified in 3GPP TS 24.008 10.5.6.6.

Activate PDP Context Reject SM Cause
Cause Value (decimal) Cause Value (bits) Cause
25 00011001 LLC or SNDCP Failure
26 00011010 Insufficient Resources
27 00011011 Missing or Unknown APN
28 00011100 Unknown PDP Address or PDP Type
29 00011101 User Authentication Failed
30 00011110 Activation Rejected By GGSN
31 00011111 Activation Rejected, Unspecified
32 00100000 Service Option Not Supported

33

00100001

Requested Service Opt Not Subscribed

34 00100010 Service Opt Temporarily Out of Order
35 00100011 NSAPI Already Used
36 00100100 Regular Deactivation
37 00100101 QoS Not Accepted
38 00100110 Network Failure
39 00100111 Reactivation Required
40 00101000 Feature Not Supported
41 00101001 Semantic Error in TFT Operation
42 00101010 Syntactical Error in TFT Operation
43 00101011 Unknown PDP Context
44 00101100 Semantic Error in Packet Filter(s)
45 00101101 Syntactical Errors in Packet Filters(s)
46 00101110 PDP Context Without TFT Already Activated
81 01010001 Invalid Transaction Identifier Value
95 01011111 Semantically Incorrect Message
96 01100000 Invalid Mandatory Information
97 01100001 Msg Type Non-existent/Not Implemented
98 01100010 Msg Type Not Compatible With Protocol State
99 01100011 IE Non-existent or Not Implemented
100 01100100 Conditional IE Error

101

01100101

Msg Not Compatible With Protocol State

111 01101111 Protocol Error, Unspecified

If you select Custom Value from the front panel, a value of 0 is sent to the UE.

The CALL:SERVice:GPRS:REJect:CAUSe command allows you to send any value between 0 and 255 to the UE, even those not mapped to a cause in the standard. If you send a value other than those listed in the above table via the GPIB command, the front panel setting displays CUSTOM .