Aide-mémoire des commandes

Assurez-vous de bien comprendre les conventions syntaxiques de langage.

Commandes de mesure

MEASure:CONTinuity?

MEASure:CURRent:{AC|DC}? [{<plage>|AUTO|MIN|MAX|DEF} [,{<résolution>|MIN|MAX|DEF}]]

MEASure:DIODe?

MEASure:{FREQuency|PERiod}? [{<plage>|MIN|MAX|DEF} [,{<résolution>|MIN|MAX|DEF}]]

MEASure:{RESistance|FRESistance}? [{<plage>|AUTO|MIN|MAX|DEF} [,{<résolution>|MIN|MAX|DEF}]]

MEASure:TEMPerature? [{FRTD|RTD|FTH|THER|DEFault} [,{<type> | DEFault} [,1 [,{<résolution>|MIN|MAX|DEF}]]]]

MEASure[:VOLTage]:{AC|DC}? [{<plage>|AUTO|MIN|MAX|DEF} [,{<résolution>|MIN|MAX|DEF}]]

MEASure[:VOLTage][:DC]:RATio? [{<plage>|AUTO|MIN|MAX|DEF} [,{<résolution>|MIN|MAX|DEF}]]

Commandes de configuration des mesures

[SENSe:]FUNCtion[:ON] "<fonction>"
[SENSe:]FUNCtion[:ON]?

Commandes de configuration des tensions alternative et continue et du rapport de tension continue

CONFigure[:VOLTage]:{AC|DC} [{<plage>|AUTO|MIN|MAX|DEF} [,{<résolution>|MIN|MAX|DEF}]]

CONFigure[:VOLTage][:DC]:RATio [{<plage>|AUTO|MIN|MAX|DEF} [,{<résolution>|MIN|MAX|DEF}]]

CONFigure?

[SENSe:]VOLTage[:DC]:IMPedance:AUTO {ON|1|OFF|0}
[SENSe:]VOLTage[:DC]:IMPedance:AUTO?

[SENSe:]VOLTage[:DC]:NPLC {<PLC>|MIN|MAX|DEF}
[SENSe:]VOLTage[:DC]:NPLC? [{MIN|MAX|DEF}]

[SENSe:]VOLTage:{AC|DC}:NULL[:STATe] {ON|1|OFF|0}
[SENSe:]VOLTage:{AC|DC}:NULL[:STATe]?

[SENSe:]VOLTage:{AC|DC}:NULL:VALue {<valeur>|MIN|MAX|DEF}
[SENSe:]VOLTage:{AC|DC}:NULL:VALue? [{MIN|MAX|DEF}]

[SENSe:]VOLTage:{AC|DC}:NULL:VALue:AUTO {ON|1|OFF|0}
[SENSe:]VOLTage:{AC|DC}:NULL:VALue:AUTO?

[SENSe:]VOLTage:{AC|DC}:RANGe:AUTO {OFF|ON|ONCE}
[SENSe:]VOLTage:{AC|DC}:RANGe:AUTO?

[SENSe:]VOLTage:{AC|DC}:RANGe {<plage>|MIN|MAX|DEF}
[SENSe:]VOLTage:{AC|DC}:RANGe? [{MIN|MAX|DEF}]

[SENSe:]VOLTage[:DC]:RESolution {<résolution>|MIN|MAX|DEF}
[SENSe:]VOLTage[:DC]:RESolution? [{MIN|MAX|DEF}]

[SENSe:]VOLTage[:DC]:ZERO:AUTO {OFF|ON|ONCE}
[SENSe:]VOLTage[:DC]:ZERO:AUTO?

[SENSe:]VOLTage:AC:BANDwidth {<filtre>|MIN|MAX|DEF}
[SENSe:]VOLTage:AC:BANDwidth? [{MIN|MAX|DEF}]

Commandes de configuration de la résistance à 2 et 4 fils

CONFigure:{RESistance|FRESistance} [{<plage>|AUTO|MIN|MAX|DEF} [,{<résolution>|MIN|MAX|DEF}]]

CONFigure?

[SENSe:]{RESistance|FRESistance}:NPLC {<PLC>|MIN|MAX|DEF}
[SENSe:]{RESistance|FRESistance}:NPLC? [{MIN|MAX|DEF}]

[SENSe:]{RESistance|FRESistance}:NULL[:STATe] {ON|1|OFF|0}
[SENSe:]{RESistance|FRESistance}:NULL[:STATe]?

[SENSe:]{RESistance|FRESistance}:NULL:VALue {<valeur>|MIN|MAX|DEF}
[SENSe:]{RESistance|FRESistance}:NULL:VALue? [{MIN|MAX|DEF}]

[SENSe:]{RESistance|FRESistance}:NULL:VALue:AUTO {ON|1|OFF|0}
[SENSe:]{RESistance|FRESistance}:NULL:VALue:AUTO?

[SENSe:]{RESistance|FRESistance}:RANGe:AUTO {OFF|ON|ONCE}
[SENSe:]{RESistance|FRESistance}:RANGe:AUTO?

[SENSe:]{RESistance|FRESistance}:RANGe {<plage>|MIN|MAX|DEF}
[SENSe:]{RESistance|FRESistance}:RANGe? [{MIN|MAX|DEF}]

[SENSe:]{RESistance|FRESistance}:RESolution {<résolution>|MIN|MAX|DEF}
[SENSe:]{RESistance|FRESistance}:RESolution? [{MIN|MAX|DEF}]

[SENSe:]RESistance:ZERO:AUTO {OFF|ON|ONCE}
[SENSe:]RESistance:ZERO:AUTO?

Commandes de configuration du courant alternatif et continu

CONFigure:CURRent:{AC|DC} [{<plage>|AUTO|MIN|MAX|DEF} [,{<résolution>|MIN|MAX|DEF}]]

CONFigure?

[SENSe:]CURRent[:DC]:NPLC {<PLC>|MIN|MAX|DEF}
[SENSe:]CURRent[:DC]:NPLC? [{MIN|MAX|DEF}]

[SENSe:]CURRent:{AC|DC}:NULL[:STATe] {ON|1|OFF|0}
[SENSe:]CURRent:{AC|DC}:NULL[:STATe]?

[SENSe:]CURRent:{AC|DC}:NULL:VALue {<valeur>|MIN|MAX|DEF}
[SENSe:]CURRent:{AC|DC}:NULL:VALue? [{MIN|MAX|DEF}]

[SENSe:]CURRent:{AC|DC}:NULL:VALue:AUTO {ON|1|OFF|0}
[SENSe:]CURRent:{AC|DC}:NULL:VALue:AUTO?

[SENSe:]CURRent:{AC|DC}:RANGe:AUTO {OFF|ON|ONCE}
[SENSe:]CURRent:{AC|DC}:RANGe:AUTO?

[SENSe:]CURRent:{AC|DC}:RANGe {<plage>|MIN|MAX|DEF}
[SENSe:]CURRent:{AC|DC}:RANGe? [{MIN|MAX|DEF}]

[SENSe:]CURRent:{AC|DC}:TERMinals {3|10}
[SENSe:]CURRent:{AC|DC}:TERMinals?

[SENSe:]CURRent[:DC]:RESolution {<résolution>|MIN|MAX|DEF}
[SENSe:]CURRent[:DC]:RESolution? [{MIN|MAX|DEF}]

[SENSe:]CURRent[:DC]:ZERO:AUTO {OFF|ON|ONCE}
[SENSe:]CURRent[:DC]:ZERO:AUTO?

[SENSe:]CURRent:AC:BANDwidth {<filtre>|MIN|MAX|DEF}
[SENSe:]CURRent:AC:BANDwidth? [{MIN|MAX|DEF}]

Commandes de configuration de la température

CONFigure:TEMPerature [{FRTD|RTD|FTH|THER|DEFault} [,{<type> | DEFault} [,1 [,{<résolution>|MIN|MAX|DEF}]]]]

CONFigure?

[SENSe:]TEMPerature:NPLC {<PLC>|MIN|MAX|DEF}
[SENSe:]TEMPerature:NPLC? [{MIN|MAX|DEF}]

[SENSe:]TEMPerature:NULL[:STATe] {ON|1|OFF|0}
[SENSe:]TEMPerature:NULL[:STATe]?

[SENSe:]TEMPerature:NULL:VALue {<valeur>|MIN|MAX|DEF}
[SENSe:]TEMPerature:NULL:VALue? [{MIN|MAX|DEF}]

[SENSe:]TEMPerature:NULL:VALue:AUTO {ON|1|OFF|0}
[SENSe:]TEMPerature:NULL:VALue:AUTO?

[SENSe:]TEMPerature:TRANsducer:{THERmistor|FTHermistor}:TYPE
[SENSe:]TEMPerature:TRANsducer:{THERmistor|FTHermistor}:TYPE?

[SENSe:]TEMPerature:TRANsducer:TYPE {FRTD|RTD|FTHermistor|THERmistor}
[SENSe:]TEMPerature:TRANsducer:TYPE?

[SENSe:]TEMPerature:ZERO:AUTO {OFF|ON|ONCE}
[SENSe:]TEMPerature:ZERO:AUTO?

UNIT:TEMPerature {C|F|K}
UNIT:TEMPerature?

Configuration des RTD

[SENSe:]TEMPerature:TRANsducer:{RTD|FRTD}:RESistance[:REFerence] {<référence>|MIN|MAX|DEF}
[SENSe:]TEMPerature:TRANsducer:{RTD|FRTD}:RESistance[:REFerence]? [{MIN|MAX|DEF}]

Commandes de configuration de la fréquence/période

CONFigure:{FREQuency|PERiod} [{<plage>|MIN|MAX|DEF} [,{<résolution>|MIN|MAX|DEF}]]

[SENSe:]{FREQuency|PERiod}:APERture {<secondes>|MIN|MAX|DEF}
[SENSe:]{FREQuency|PERiod}:APERture? [{MIN|MAX|DEF}]

[SENSe:]{FREQuency|PERiod}:NULL[:STATe] {ON|1|OFF|0}
[SENSe:]{FREQuency|PERiod}:NULL[:STATe]?

[SENSe:]{FREQuency|PERiod}:NULL:VALue {<valeur>|MIN|MAX|DEF}
[SENSe:]{FREQuency|PERiod}:NULL:VALue? [{MIN|MAX|DEF}]

[SENSe:]{FREQuency|PERiod}:NULL:VALue:AUTO {ON|1|OFF|0}
[SENSe:]{FREQuency|PERiod}:NULL:VALue:AUTO?

[SENSe:]{FREQuency|PERiod}:RANGe:LOWer {<filtre>|MIN|MAX|DEF}
[SENSe:]{FREQuency|PERiod}:RANGe:LOWer? [{MIN|MAX|DEF}]

[SENSe:]{FREQuency|PERiod}:VOLTage:RANGe:AUTO {OFF|ON|ONCE}
[SENSe:]{FREQuency|PERiod}:VOLTage:RANGe:AUTO?

[SENSe:]{FREQuency|PERiod}:VOLTage:RANGe {<plage>|MIN|MAX|DEF}
[SENSe:]{FREQuency|PERiod}:VOLTage:RANGe? [{MIN|MAX|DEF}]

Commandes de configuration de la continuité et des diodes

CONFigure:CONTinuity

CONFigure:DIODe

Commandes de configuration diverses

ROUTe:TERMinals?

Commandes de déclenchement

*TRG

ABORt

INITiate[:IMMediate]

READ?

SAMPle:COUNt {<nombre>|MIN|MAX|DEF}
SAMPle:COUNt? [{MIN|MAX|DEF}]

TRIGger:COUNt {<nombre>|MIN|MAX|DEF|INFinity}
TRIGger:COUNt? [{MIN|MAX|DEF}]

TRIGger:DELay {<secondes>|MIN|MAX|DEF}
TRIGger:DELay? [{MIN|MAX|DEF}]

TRIGger:DELay:AUTO {ON|1|OFF|0}
TRIGger:DELay:AUTO?

TRIGger:SLOPe {POSitive|NEGative}
TRIGger:SLOPe?

TRIGger:SOURce {IMMediate|EXTernal|BUS}
TRIGger:SOURce?

OUTPut:TRIGger:SLOPe {POSitive|NEGative}
OUTPut:TRIGger:SLOPe?

Commandes (mathématiques) de calcul

Générales

CALCulate:CLEar[:IMMediate]

Histogramme

CALCulate:TRANsform:HISTogram[:STATe] {ON|1|OFF|0}
CALCulate:TRANsform:HISTogram[:STATe]?

CALCulate:TRANsform:HISTogram:ALL?

CALCulate:TRANsform:HISTogram:DATA?

CALCulate:TRANsform:HISTogram:COUNt?

CALCulate:TRANsform:HISTogram:CLEar[:IMMediate]

CALCulate:TRANsform:HISTogram:POINts {10|20|40|100|200|400|MIN|MAX|DEF}, 100 par défaut
CALCulate:TRANsform:HISTogram:POINts? [{MIN|MAX|DEF}]

CALCulate:TRANsform:HISTogram:RANGe:AUTO {ON|1|OFF|0}
CALCulate:TRANsform:HISTogram:RANGe:AUTO?

CALCulate:TRANsform:HISTogram:RANGe:{LOWer|UPPer} {<valeur>|MIN|MAX|DEF}
CALCulate:TRANsform:HISTogram:RANGe:{LOWer|UPPer}? [{MIN|MAX|DEF}]

Tests de limites

CALCulate:LIMit[:STATe] {ON|1|OFF|0}
CALCulate:LIMit[:STATe]?

CALCulate:LIMit:CLEar[:IMMediate]

CALCulate:LIMit:{LOWer|UPPer}[:DATA] {<valeur>|MIN|MAX|DEF}
CALCulate:LIMit:{LOWer|UPPer}[:DATA]? [{MIN|MAX|DEF}]

Mise à l'échelle

CALCulate:SCALe:FUNCtion {DB|DBM}
CALCulate:SCALe:FUNCtion?

CALCulate:SCALe[:STATe] {ON|1|OFF|0}
CALCulate:SCALe[:STATe]?

CALCulate:SCALe:DB:REFerence {<référence>|MIN|MAX|DEF}
CALCulate:SCALe:DB:REFerence? [{MIN|MAX}]

CALCulate:SCALe:DBM:REFerence {<référence>|MIN|MAX|DEF}
CALCulate:SCALe:DBM:REFerence? [{MIN|MAX}]

CALCulate:SCALe:REFerence:AUTO {ON|1|OFF|0}
CALCulate:SCALe:REFerence:AUTO?

Statistiques

CALCulate:AVERage[:STATe] {ON|1|OFF|0}
CALCulate:AVERage[:STATe]?

CALCulate:AVERage:ALL?

CALCulate:AVERage:AVERage?

CALCulate:AVERage:MAXimum?

CALCulate:AVERage:MINimum?

CALCulate:AVERage:PTPeak?

CALCulate:AVERage:SDEViation?

CALCulate:AVERage:COUNt?

CALCulate:AVERage:CLEar[:IMMediate]

Commandes de mémoire de mesures

FETCh?

R? [<lectures_max>]

DATA:LAST?

DATA:POINts:EVENt:THReshold <nombre>
DATA:POINts:EVENt:THReshold?

DATA:POINts?

DATA:REMove? <nombre_lectures> [,WAIT]

Commandes d'étalonnage

CALibration:ADC?

CALibration[:ALL]?

CALibration:COUNt?

CALibration:SECure:CODE <nouveau_code>

CALibration:SECure:STATe {ON|1|OFF|0} [, <code>]
CALibration:SECure:STATe?

CALibration:STORe

CALibration:STRing "<chaîne>"
CALibration:STRing?

CALibration:VALue <valeur>
CALibration:VALue?

Commandes de stockage d'états

*LRN?

*RCL {0|1|2|3|4}

*SAV {0|1|2|3|4}

MMEMory:LOAD:STATe <fichier>

MMEMory:STORe:STATe <fichier>

MMEMory:STATe:RECall:AUTO {ON|1|OFF|0}
MMEMory:STATe:RECall:AUTO?

MMEMory:STATe:RECall:SELect <fichier>
MMEMory:STATe:RECall:SELect?

MMEMory:STATe:VALid? <fichier>

Commandes du périphérique de stockage de masse

MMEMory:CATalog[:ALL]? [<dossier>[<spéc_fichier>]]

MMEMory:CDIRectory <dossier>
MMEMory:CDIRectory?

MMEMory:COPY <fichier 1>, <fichier 2>

MMEMory:DELete {<fichier>|<spéc_fichier>}

MMEMory:DOWNload:DATA <bloc_binaire>

MMEMory:DOWNload:FNAMe <fichier>
MMEMory:DOWNload:FNAMe?

MMEMory:MOVE <fichier 1>, <fichier 2>

MMEMory:LOAD:PREFerences <fichier>

MMEMory:LOAD:STATe <fichier>

MMEMory:MDIRectory <dossier>

MMEMory:RDIRectory <dossier>

MMEMory:STORe:DATA RDG_STORE, <fichier>

MMEMory:STORe:PREFerences <fichier>

MMEMory:STORe:STATe <fichier>

MMEMory:UPLoad? <fichier>

Commandes IEEE-488

*CLS

*ESE <valeur_activation>
*ESE?

*ESR?

*IDN?

*LRN?

*OPC

*OPC?

*OPT?

*PSC {0|1}
*PSC?

*RCL {0|1|2|3|4}

*RST

*SAV {0|1|2|3|4}

*SRE <valeur_activation>
*SRE?

*STB?

*TRG

*TST?

*WAI

Commandes système

*IDN?

*RST

*TST?

DISPlay[:STATe] {ON|1|OFF|0}
DISPlay[:STATe]?

DISPlay:TEXT:CLEar

DISPlay:TEXT[:DATA] "<chaîne>"
DISPlay:TEXT[:DATA]?

DISPlay:VIEW {NUMeric|HISTogram|TCHart|METer}
DISPlay:VIEW?

HCOPy:SDUMp:DATA?

HCOPy:SDUMp:DATA:FORMat {PNG|BMP}
HCOPy:SDUMp:DATA:FORMat?

LXI:IDENtify[:STATe] {ON|1|OFF|0}
LXI:IDENtify[:STATe]?

LXI:MDNS:ENABle {ON|1|OFF|0}
LXI:MDNS:ENABle?

LXI:MDNS:HNAMe[:RESolved]?

LXI:MDNS:SNAMe:DESired "<nom>"
LXI:MDNS:SNAMe:DESired?

LXI:MDNS:SNAMe[:RESolved]?

LXI:RESet

LXI:RESTart

SYSTem:BEEPer[:IMMediate]

SYSTem:BEEPer:STATe {ON|1|OFF|0}
SYSTem:BEEPer:STATe?

SYSTem:CLICk:STATe {ON|1|OFF|0}
SYSTem:CLICk:STATe?

SYSTem:DATE <année>, <mois>, <jour>
SYSTem:DATE?

SYSTem:ERRor[:NEXT]?

SYSTem:HELP?

SYSTem:IDENtify {DEFault|HP34401A}
SYSTem:IDENtify?

SYSTem:LABel "<chaîne>"
SYSTem:LABel?

SYSTem:PRESet

SYSTem:SECurity:COUNt?

SYSTem:SECurity:IMMediate

SYSTem:TEMPerature?

SYSTem:TIME <heure>, <minute>, <seconde>
SYSTem:TIME?

SYSTem:USB:HOST:ENABle {ON|1|OFF|0}
SYSTem:USB:HOST:ENABle?

SYSTem:VERSion?

SYSTem:WMESsage "<chaîne>"
SYSTem:WMESsage?

TEST:ALL?

Commandes de verrouillage des interfaces

SYSTem:LOCK:NAME?

SYSTem:LOCK:OWNer?

SYSTem:LOCK:RELease

SYSTem:LOCK:REQuest?

Commandes de gestion des licences

SYSTem:LICense:CATalog?

SYSTem:LICense:DELete "<nom_option>"

SYSTem:LICense:DELete:ALL

SYSTem:LICense:DESCription? "<nom_option>"

SYSTem:LICense:ERRor:COUNt?

SYSTem:LICense:ERRor?

SYSTem:LICense:INSTall [{<dossier>|<fichier>}]
SYSTem:LICense:INSTall? "<nom_option>"

Commandes de configuration des interfaces

SYSTem:COMMunicate:ENABle {ON|1|OFF|0}, {GPIB|USB|LAN|SOCKets|TELNet|VXI11|WEB|USBMtp|USBHost}
SYSTem:COMMunicate:ENABle? {GPIB|USB|LAN|SOCKets|TELNet|VXI11|WEB|USBMtp|USBHost}

SYSTem:COMMunicate:GPIB:ADDRess <adresse>
SYSTem:COMMunicate:GPIB:ADDRess?

SYSTem:COMMunicate:LAN:CONTrol?

SYSTem:COMMunicate:LAN:DHCP {ON|1|OFF|0}
SYSTem:COMMunicate:LAN:DHCP?

SYSTem:COMMunicate:LAN:DNS[{1|2}] "<adresse>"
SYSTem:COMMunicate:LAN:DNS[{1|2}]? [{CURRent|STATic}]

SYSTem:COMMunicate:LAN:DOMain?

SYSTem:COMMunicate:LAN:GATeway "<adresse>"
SYSTem:COMMunicate:LAN:GATeway? [{CURRent|STATic}]

SYSTem:COMMunicate:LAN:HOSTname "<nom>"
SYSTem:COMMunicate:LAN:HOSTname? [{CURRent|STATic}]

SYSTem:COMMunicate:LAN:IPADdress "<adresse>"
SYSTem:COMMunicate:LAN:IPADdress? [{CURRent|STATic}]

SYSTem:COMMunicate:LAN:MAC?

SYSTem:COMMunicate:LAN:SMASk "<masque>"
SYSTem:COMMunicate:LAN:SMASk? [{CURRent|STATic}]

SYSTem:COMMunicate:LAN:TELNet:PROMpt "<chaîne>"
SYSTem:COMMunicate:LAN:TELNet:PROMpt?

SYSTem:COMMunicate:LAN:TELNet:WMESsage "<chaîne>"
SYSTem:COMMunicate:LAN:TELNet:WMESsage?

SYSTem:COMMunicate:LAN:UPDate

SYSTem:COMMunicate:LAN:WINS[{1|2}] "<adresse>"
SYSTem:COMMunicate:LAN:WINS[{1|2}]? [{CURRent|STATic}]

SYSTem:USB:HOST:ENABle {ON|1|OFF|0}
SYSTem:USB:HOST:ENABle?

Commandes du système d'état

*CLS

*ESE <valeur_activation>
*ESE?

*ESR?

*PSC {0|1}
*PSC?

*SRE <valeur_activation>
*SRE?

*STB?

STATus:OPERation:CONDition?

STATus:OPERation:ENABle <valeur_activation>
STATus:OPERation:ENABle?

STATus:OPERation[:EVENt]?

STATus:PRESet

STATus:QUEStionable:CONDition?

STATus:QUEStionable:ENABle <valeur_activation>
STATus:QUEStionable:ENABle?

STATus:QUEStionable[:EVENt]?